Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 03, 2022
Application Purpose
Original Equipment
Date of Application
Aug 03, 2022
Equipment Note
CLAMP MULTIMETER
Frequency Range
2402.00000000 - 2480.00000000
Company
ZhuHai JiDa HuaPu Instrument Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

6000 COUNTS WITH APP DC/AC TRUE-RMS CLAMP MULTIMETER OPERATION MANUAL 1. Overview The auto range clamp multimeter is a portable and stable performance. Using 6000 counts digit LCD monitor with character 16mm high. With overall circuitry design centering on large-scale IC A/D converters in conjunction and over-load protection circuit, the meters give excellent performance and exquisite making as a handy utility instrument. The meter can be connected with mobile phone by Bluetooth, and display on phone by APP, you can remote monitoring the measurement condition, the distance control is 10~15m. The meters can be used to measure DC & AC voltage, DC & AC current, resistance, capacitor, frequency, duty cycle, temperature, Non Contact AC Volt age (NCV) detection, positive diode volt age fall and audibl e continuity. 2. Panel Layout 1. Clamp jaws: Opens 26mm to enclose conductor. 2. NCV detection area (bottom). 3. Lamp light: Press the “HOLD” key over 2 seconds to lig ht the lamp light, it will light up too when the built-in buzzer sounds. 4. Jaw-opening handle: Opens and closes the jaws. 5. Rotary Switch: Use this switch to select functions and ranges. 6.HOLD key: Press the “HOLD” key to lock display value, and the “DH” sign will appear on the display, press it again to exit. Press “HOLD” key more than 2 seconds, the back lig ht and the lamp lig ht will light up, press it more than 2 se conds again, the back light and the lamp lig ht will light off. 7.SEL key: This key work on the " " range, press the key to choose resistance, continuity, diode or capacitance test, on the volt age or current range, change to DC or AC, on the range, change to or test°C °C. 8.MAX/MIN key: Press the “MAX/MIN” key to lock MAX or MIN value, and the “MAX” or “MIN” sign will appear on the display, press it over 2 seconds to exit. 9.REL Key: Press the “REL” key, the meter enters relativ e measuring mode, “△ ” is displayed on the LCD and the present reading becomes the reference value and displayed on the display. Relative measurement REL△=measurement value-Reference value. Press it again to exit. 10.Hz/Duty Key: On “ACV/ACA” or “Hz” range, press the “Hz%” key, you can choose the Frequency or Duty Cycle measurement. 11. LCD display: 6000 counts digit, full function symbol display. 12. COM: COM and Temperature “-” Input Jack 13.V Hz: V///Hz/T+ Input Jack 3. Safety Information 3-1 The meter is designed according to IEC-1010 concerning electronic measuring instruments with an over-voltage category 600V (CAT II) and polluti on 2. 3-2 Foll ow all safety and operating instructions to ensure that the meter is used safely and is kept in good operating condition. 3-3 safety symbols: Important safety informati on, refer to the operatin g manual. Dangerous voltage may be presence. Double insulation (protection Class II) 4. Special Cautions for Opera tion 4-1 The meters can be safe only according to standard procedures when used in conjunctions with the suppli ed test leads. To replace damaged test leads with only the same model or same electric specifications. 4-2 To avid risk of electri c shock, do not use the meters before the cover is in place. 4-3 The range switch should be right positi on for the testing. 4-4 To avoid electri c shock and damaging the instruments, the input signals are forbidden to exceed the specified limits. 4-5 When measuring TV set or switched power, attention should be paid to the possible pulses that may bring destruction to the circ uit. 4-6 Range switc h position is forbidden to be changed at random during measurement. 4-7 Take caution against shock in the course of measuring volt age higher than DC 60V & AC 30V. 4-8 Before opening the cover of the battery cabinet to replace batteries. disconnect the test leads from any external circ uit , set the selector switc h to "OFF" position. 4-9 Keep the fingers after the protectio n ring when m easuring through the instrument lead. 4-10 Keep the fingers after the protectio n ring when measuri ng through the clamp. 4-11 After operation is finished, set function switc h at OFF to save battery power. 4-12 If the meter is without usage for long time, take out battery to avoid damage by battery leakage. 5. GENERAL SPECIFICATIONS 5-1 Max Voltage between input terminal and Earth Ground: CAT II 600V or CAT III 300V 5-2 Over-range Indication: display “OL” for the significant digit. 5-3 Automatic display of negative polarity “-” . 5-4 Low Battery Indication: “ ” displayed. 5-5 Max LCD display: 6000 counts digit. 5-6 Auto range control 5-7 Clamp opening size: 26mm. 5-8 Power supply: 1.5V×2 “AAA” R03P battery 5-9 Operati ng Temp.: 0 to 40 (relative humidity <85%)°C °C 5-10 Storage Temp.:-10 to 50 (relative humidity <85%)°C °C 5-11 Guaranteed precision Temp.: 23±5 (relativ e humidity <70%)°C 5-12 Dimension: 207(H)×75(W)×37(D)mm. 5-13 Weight: Approx. 280g (including battery). 6. Testing Specifi cations Accuracy is specified for a period of year after cali bration and at 18 to 28°C °C (64 to 82) wi th relative humidity to 70%.°C °C 6-1 DC Voltage Range ResolutionAccuracy 600mV 0.1mV 6V1mV 60V10mV ±(0.5% of rdg + 2 digits) 600V 100mV ±(0.8% of rdg + 2 digits) -- Impedance: 10MΩ, More than 100MΩ on 600mV range -- Overload protection: 600V DC or AC rms 6-2 AC Voltage (T rue RMS) Range ResolutionAccuracy 6V1mV 60V10mV ±(1.0% of rdg + 3 digits) 600V 100mV ±(1.5% of rdg + 3 digits) -- Impedance: 10MΩ -- Overload protection: 600V DC or AC rms -- Frequency Range: 40 to 2kHz 6-3 DC Current Range ResolutionAccuracy 60A 10mA ±(2.5% of rdg + 10 digits) 400A 100mA ±(3.0% of rdg + 10 digits) -- Overload protection: 400A DC or AC rms 6-4 AC Current (T rue RMS) Range ResolutionAccuracy 60A 10mA ±(2.5% of rdg + 10 digits) 400A 100mA ±(3.0% of rdg + 10 digits) -- Overload protection: 400A DC or AC rms -- Frequency Range: 40 to 100Hz 6-5 Resistance Range ResolutionAccuracy 600Ω0.1Ω ±(1.0% of rdg + 3 digits) 6kΩ1Ω 60kΩ10Ω 600kΩ 100Ω 6MΩ1kΩ ±(1.0% of rdg + 2 digits) 60MΩ 10kΩ ±(1.5% of rdg + 3 d…

Text truncated - open the document above for the full version.

External Photos

Page 1 of 4 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8

ID Label/Location Info

Page 1 of 1 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L1.5cm x 1.0cm) Label Location CLAMP MULTIMETER Model: HP-7200-APP FCC ID: 2A7T4-HP-7200-APP

Internal Photos

Page 1 of 4 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Antenna

RF Exposure Info

Page 1 of 3 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziw ei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: w [email protected] | Web: w w w.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2A7T4-HP-7200-APP Product name : CLAMP MULTIMETER Test Model : HP-7200-APP Power Supply : DC 3V by 2*AAA battery Hardware Version : / Software Version : / Bluetooth : 2402MHz ~ 2480MHz Channel Number : 40 channels for Bluetooth V4.2 (DTS) Channel Spacing : 2MHz for Bluetooth V4.2(DTS) Modulation Type : GFSK for Bluetooth V4.2 (DTS) Bluetooth Version : V4.2 Antenna Type : PCB Antenna Antenna Gain : 0dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm Page 2 of 3 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziw ei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: w [email protected] | Web: w w w.lcs-cert.com Scan code to check authenticity and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Results <BT LE> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.97 19 2440 1.06 39 2480 1.14 Page 3 of 3 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziw ei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: w [email protected] | Web: w w w.lcs-cert.com Scan code to check authenticity 5. Manufacturing Tolerance <BT LE> GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 1.0 1.0 Tolerance ±(dB) 1.0 1.0 1.0 6. Evaluation Results 6.1 Standalone Evaluation Band/Mode f (GHz) Antenna Distance (mm) RF output power SAR Test Exclusion Thres…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BLE (Conducted Measurement) Product Name: CLAMP MULTIMETER Test Model: HP-7200-APP Environmental Conditions Temperature: 23.5 C Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Nick Peng Supervised by: Ling Zhu Page 2 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 6dB Bandwidth Condition Mode Frequency (MHz) Antenna 6 dB Bandwidth (MHz) Limit 6 dB Bandwidth (MHz) Verdict NVNT BLE 1M 2402 Ant1 0.673 >=0.5 Pass NVNT BLE 1M 2440 Ant1 0.661 >=0.5 Pass NVNT BLE 1M 2480 Ant1 0.697 >=0.5 Pass Page 3 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs 6dB Bandwidth NVNT BLE 1M 2402MHz Ant1 6dB Bandwidth NVNT BLE 1M 2440MHz Ant1 Page 4 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 6dB Bandwidth NVNT BLE 1M 2480MHz Ant1 Page 5 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402 Ant1 0.97 30 Pass NVNT BLE 1M 2440 Ant1 1.06 30 Pass NVNT BLE 1M 2480 Ant1 1.14 30 Pass Page 6 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 1M 2402MHz Ant1 Power NVNT BLE 1M 2440MHz Ant1 Page 7 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 1M 2480MHz Ant1 Page 8 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Duty Factor (dB) Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 1M 2402 Ant1 -7.8 0 -7.8 8 Pass NVNT BLE 1M 2440 Ant1 -8.78 0 -8.78 8 Pass NVNT BLE 1M 2480 Ant1 -8.3 0 -8.3 8 Pass Page 9 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 1M 2402MHz Ant1 PSD NVNT BLE 1M 2440MHz Ant1 Page 10 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT BLE 1M 2480MHz Ant1 Page 11 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT BLE 1M 2402 Ant1 -57.35 -20 Pass NVNT BLE 1M 2480 Ant1 -57.98 -20 Pass Page 12 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Band Edge NVNT BLE 1M 2402MHz Ant1 Ref Band Edge NVNT BLE 1M 2402MHz Ant1 Emission Page 13 of 23 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101,…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 31 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For ZhuHai JiDa HuaPu Instrument Co.,Ltd CLAMP MULTIMETER Test Model: HP-7200-APP Prepared for : ZhuHai JiDa HuaPu Instrument Co.,Ltd Address : 3/F, Build 4, Qinghua Science Park Building, No.101 Universitiy Road, Tangjiawan Village, Zhuhai, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : June 29, 2022 Number of tested samples : 2 Sample No. : A061722121-1, A061722121-2 Serial number : Prototype Date of Test : June 29, 2022 ~ July 08, 2022 Date of Report : July 08, 2022 Page 2 of 31 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA061722121EA Date of Issue .................................. : July 08, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : ZhuHai JiDa HuaPu Instrument Co.,Ltd Address .......................................... : 3/F, Build 4, Qinghua Science Park Building, No.101 Universitiy Road, Tangjiawan Village, Zhuhai, China Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No.................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : CLAMP MULTIMETER Trade Mark ..................................... : N/A Test Model ...................................... : HP-7200-APP Ratings ........................................... : DC 9V by 6F22 Battery Result ............................................ : Positive Compiled by: Supervised by: Approved by: Li Huan/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 31 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Model............................... : HP-7200-APP EUT......................................... : CLAMP MULTIMETER Applicant............................... : ZhuHai JiDa HuaPu Instrument Co.,Ltd Address.................................. : 3/F, Build 4, Qinghua Science Park Building, No.101 Universitiy Road, Tangjiawan Village, Zhuhai, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : ZhuHai JiDa HuaPu Instrument Co.,Ltd Address................................... : 3/F, Build 4, Qinghua Science Park Building, No.101 Universitiy Road, Tangjiawan Village, Zhuhai, China Telephone............................... : / Fax.......................................... : / Factory................................... : / Address................................... : / Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA061722121EA July 08, 2022 Date of issue Page 4 of 31 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 July 08, 2022 Initial Issue --- Page 5 of 31 FCC ID: 2A7T4-HP-7200-APP Report No.: LCSA061722121EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS 1. GEN…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 FCC ID: 2A7T4-HP-7200-APP Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2

Contact Information

Applicant

Wei Bai
[email protected]86-756-3374032Fax: 86-756-3374032

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.30 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from ZhuHai JiDa HuaPu Instrument Co.,Ltd

Humidity meter - FCC ID 2A7T4HP-930A - ZhuHai JiDa HuaPu Instrument Co.,Ltd
2A7T4HP-930A

Humidity meter

Sep 24, 2023

Equipment Class

DTS - Digital Transmission System
Anemometer - FCC ID 2A7T4-HP-866B-APP - ZhuHai JiDa HuaPu Instrument Co.,Ltd
2A7T4-HP-866B-APP

Anemometer

Aug 03, 2022

Equipment Class

DTS - Digital Transmission System
CLAMP MULTIMETER - FCC ID 2A7T4-HP-570C-APP - ZhuHai JiDa HuaPu Instrument Co.,Ltd
2A7T4-HP-570C-APP

CLAMP MULTIMETER

Aug 03, 2022

Equipment Class

DTS - Digital Transmission System
Non contact infrared thermometer - FCC ID 2A7T4-HP-1500-APP - ZhuHai JiDa HuaPu Instrument Co.,Ltd
2A7T4-HP-1500-APP

Non contact infrared thermometer

Aug 03, 2022

Equipment Class

DTS - Digital Transmission System