FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Adyen N.V./
  3. 2A7UQ-SFO1

2A7UQ-SFO1SFO1

Adyen N.V.

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Sep 29, 2024
Application Purpose
Original Equipment
Date of Application
Sep 29, 2024
Equipment Note
SFO1
Frequency Range
5745.00000000 - 5825.00000000
Company
Adyen N.V.
Country
Netherlands

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Adyen N.V. Simon Carmiggeltstraat 6-50 Amsterdam N-Holland 1011 DJ Netherlands Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-9-12 To whom it may concern: We, Adyen N.V., hereby certify that the equipment for which authorization is sought (FCC ID: 2A7UQ- SFO1) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Roelant Prins Adyen N.V. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii)-U, V03 Docusign Envelope ID: 14538C49-8164-4527-89C6-9E85A06B419D

Attestation Statements

Adyen N.V. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 9/18/2024 U.S. Agent Designation Adyen N.V. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2A7UQ-SFO1): Adyen Services Inc. acknowledges their obligation to accept service of process on behalf of Adyen N.V.. Adyen N.V. with the FRN 0032641516 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Roelant Prins CCO Adyen Services Inc. Name and company of U.S. agent:Adyen Services Inc. Physical U.S. address of agent:274 Brannan Street Suite 600 San Francisco, CA 94107 United States FRN of U.S. agent:0033528993 Email address of U.S. agent: [email protected] 48_[model] US_Agent_2.911(d)(7)-U, V05 Docusign Envelope ID: DD3742C6-37B7-4A06-956F-F2EB80E06889

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-9-12> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: For the product stated above, we request that the following information be held confidential; The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. FCC IDModel name 2A7UQ-SFO1SFO1 Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos180Days Internal Photos180Days Block Diagram Schematics Test Setup Photos180Days User’s Manual180Days Parts List Tune Up Operational Descriptions Docusign Envelope ID: 14538C49-8164-4527-89C6-9E85A06B419D If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Roelant Prins/ Company: Adyen N.V. Address: Simon Carmiggeltstraat 6-50 Amsterdam N-Holland 1011 DJ Netherlands Phone: +31 643275646 Fax: +31 643275646 E-Mail: [email protected] Docusign Envelope ID: 14538C49-8164-4527-89C6-9E85A06B419D

Cover Letter(s)

Adyen N.V. Simon Carmiggeltstraat 6-50 Amsterdam N-Holland 1011 DJ Netherlands Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-9-12 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2A7UQ-SFO1 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Roelant Prins/ Company: Adyen N.V. Address: Simon Carmiggeltstraat 6-50 Amsterdam N-Holland 1011 DJ Netherlands Phone: +31 643275646 Fax: +31 643275646 E-Mail: [email protected] Docusign Envelope ID: 14538C49-8164-4527-89C6-9E85A06B419D

Cover Letter(s)

UNII Device Declaration Letter To whom it may concern: We have declared below featured for FCC equipment authorization, Device FCC ID: 2A7UQ-SFO1 (1)DFS Device: Master Client with Radar detection capability N/A Client without radar detection capability, (2)Active / Passive Scanning , adhoc mode access point capability (3)Country code selection ability Yes No If yes, pls explain how it was implemented: (4)Meet 15.202 requirement Yes No pls check below : A master device is defined as a device operating in a mode in which it has the capability to transmit without receiving an enabling signal. In this mode it is able to select a channel and initiate a network by sending enabling signals to other devices A client device is defined as a device operating in a mode in which the transmissions of the device are under control of the master. A device in client mode is not able to initiate a network. (5)For client devices that have software configuration control to operate in different modes (active scanning in some and passive scanning in others) in different bands (devices with multiple equipment classes or those that operate on non-DFS frequencies) or modular devices which configure the modes of operations through software, the application must provide software and operations description on how the software and / or hardware is implemented to ensure that proper operations modes cannot be modified by end user or an installer. Apply Does not apply (If apply, pls help to provide explanation on it was implement, and how software was controlled) Should you have any questions or comments regarding this matter, please have my best attention. Frequency Band (MHz) Active Scanning (the device can transmit a probe (beacon)) passive scanning (where the device is can listen only with no probes) Ad Hoc Mode capability Access point capability 5180-5240 Yes No Yes No Yes No Yes No 5190-5230 Yes No Yes No Yes No Yes No 5210-5210 Yes No Yes No Yes No Yes No 5260-5320 Yes No Yes No Yes No Yes No 5270-5310 Yes No Yes No Yes No Yes No 5290-5290 Yes No Yes No Yes No Yes No 5500-5700 Yes No Yes No Yes No Yes No 5510-5690 Yes No Yes No Yes No Yes No 5530-5610 Yes No Yes No Yes No Yes No 5745-5825 Yes No Yes No Yes No Yes No 5755-5795 Yes No Yes No Yes No Yes No 5775-5775 Yes No Yes No Yes No Yes No Docusign Envelope ID: 14538C49-8164-4527-89C6-9E85A06B419D Sincerely, {新申请人签名} (Signed) Name/ Title: Roelant Prins/ Company:Adyen N.V. Address:Simon Carmiggeltstraat 6-50 Amsterdam N-Holland 1011 DJ Netherlands Phone:+31 643275646 Fax:+31 643275646 E-Mail:[email protected] Docusign Envelope ID: 14538C49-8164-4527-89C6-9E85A06B419D

ID Label/Location Info

Page 1 of 1 FCC ID:2A7UQ-SFO1 IC: 30044-SFO1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION Note:The font is silk-screened on the product Label Location

RF Exposure Info

Page 1 of 10 FCC ID:2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A Detailed System Check Results 1. System Performance Check System Performance Check 750 MHz Head System Performance Check 835 MHz Head System Performance Check 1750 MHz Head System Performance Check 1900 MHz Head System Performance Check 2450 MHz Head System Performance Check 2600 MHz Head System Performance Check 5250 MHz Head System Performance Check 5600 MHz Head System Performance Check 5750 MHz Head Page 2 of 10 FCC ID:2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/15 Test Laboratory: LCS-SAR Lab System Check_750Mhz DUT: D750V3; Type: D750V3; Serial: 1191 Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1 Medium parameters used: f = 750 MHz; σ = 0.908 S/m; ε r = 42.179; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(9.66, 9.66, 9.66); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: SAM v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (5x18x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.08 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 54.23 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 3.65 W/kg SAR(1 g) = 2.26 W/kg; SAR(10 g) = 1.44 W/kg Maximum value of SAR (measured) = 3.19 W/kg 0 dB = 3.19 W/kg = 5.04 dBW/kg Page 3 of 10 FCC ID:2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/16 Test Laboratory: LCS-SAR Lab System Check_835Mhz DUT: D835V2; Type: D835V2; Serial: 4d124 Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.905 S/m; ε r = 41.768; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(9.26, 9.26, 9.26); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: SAM v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (5x18x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.15 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 54.23 V/m; Power Drift = -0.11 dB Peak SAR (extrapolated) = 3.65 W/kg SAR(1 g) = 2.47 W/kg; SAR(10 g) = 1.65 W/kg Maximum value of SAR (measured) = 3.19 W/kg 0 dB = 3.19 W/kg = 5.04 dBW/kg Page 4 of 10 FCC ID:2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/17 Test Laboratory: LCS-SAR Lab System Check_1750Mhz DUT: D1750V2; Type: D1750V2; Serial: 1035 Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1750 MHz; σ = 1.388 S/m; ε r = 41.205; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(8.16, 8.16, 8.16); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: SAM v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 11.6 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 82.77 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 16.7 W/kg SAR(1 g) = 9.04 W/kg; SAR(10 g) = 4.77 W/kg Maximum value of SAR (measured) = 12.9 W/kg 0 dB = 12.9 W/kg = 11.11 dBW/kg Page 5 of 10 FCC ID:2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/7/18 Test Laboratory: LCS-SAR Lab System Check_1900Mhz DUT: D1900V2; Type: D1900V2; Serial: 5d055 Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1900 MHz; σ = 1.437 S/m; ε r = 41.171; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.85, 7.85, 7.85); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: SAM v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 12.5 W/kg Configuration/Unnamed procedure/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, …

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 15 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B Detailed Test Results 1. LTE LTE Band 7 for Body LTE Band 12 for Body LTE Band 13 for Body LTE Band 14 for Body LTE Band 25 for Body LTE Band 26 for Body LTE Band 41 for Body LTE Band 66 for Body LTE Band 71 for Body 2. WIFI WIFI 2.4GHz for Body WIFI 5.2GHz for Body WIFI 5.3GHz for Body WIFI 5.5GHz for Body WIFI 5.8GHz for Body Date: 2024/07/22 Test Laboratory: LCS-SAR Lab LTE B7 20M QPSK 1RB49 21100CH Rear side 0mm DUT: SFO1; Type: SFO1; Serial: A240603189-1 Communication System: UID 0, LTE-FDD (0); Frequency: 2510 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2510 MHz; σ = 1.967 S/m; ε r = 39.087; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.42, 7.42, 7.42); Calibrated: 2023/11/23;  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/ Rear side 0mm /Area Scan (12x12x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.809 W/kg Configuration/ Rear side 0mm /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 2.842 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 1.45 W/kg SAR(1 g) = 0.684 W/kg; SAR(10 g) = 0.291 W/kg Maximum value of SAR (measured) = 0.835 W/kg Page 3 of 15 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/07/15 Test Laboratory: LCS-SAR Lab LTE B12 10M QPSK 1RB49 23095CH Rear side 0mm DUT: SFO1; Type: SFO1; Serial: A240603189-1 Communication System: UID 0, LTE-FDD (0); Frequency: 707.5 MHz;Duty Cycle: 1:1 Medium parameters used (interpolated): f = 707.5 MHz; σ = 0.899 S/m; ε r = 42.105; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(9.66, 9.66, 9.66); Calibrated: 2023/11/23;  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/ Rear side 0mm /Area Scan (10x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.536 W/kg Configuration/ Rear side 0mm /Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 7.379 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 1.23 W/kg SAR(1 g) = 0.456 W/kg; SAR(10 g) = 0.237 W/kg Maximum value of SAR (measured) = 0.538 W/kg Date: 2024/07/15 Test Laboratory: LCS-SAR Lab LTE B13 10M QPSK 1RB24 23230CH Rear side 0mm DUT: SFO1; Type: SFO1; Serial: A240603189-1 Communication System: UID 0, LTE-FDD (0); Frequency: 782 MHz;Duty Cycle: 1:1 Medium parameters used: f = 782 MHz; σ = 0.912 S/m; ε r = 42.193; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(9.66, 9.66, 9.66); Calibrated: 2023/11/23;  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/ Rear side 0mm /Area Scan (10x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.455 W/kg Configuration/ Rear side 0mm /Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 7.470 V/m; Power Drift = -0.19 dB Peak SAR (extrapolated) = 0.836 W/kg SAR(1 g) = 0.372 W/kg; SAR(10 g) = 0.182 W/kg Maximum value of SAR (measured) = 0.458 W/kg Page 5 of 15 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/07/15 Test Laboratory: LCS-SAR Lab LTE B14 10M QPSK 1RB0 23330CH Rear side 0mm DUT: SFO1; Type: SFO1; Serial: A240603189-1 Communication System: UID 0, LTE-FDD (0); Frequency: 793 MHz;Duty Cycle: 1:1 Medium parameters used: f = 793 MHz; σ = 0.909 S/m; ε r = 42.274; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(9.66, 9.66, 9.66); Calibrated: 2023/11/23;  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/ Rear side 0mm /Area Scan (10x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.435 W/kg Configuration/ Rear side 0mm /Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 7.484 V/m; Power Drift = 0.19 dB Peak SAR (extrapolated) = 0.962 W/kg SAR(1 g) = 0.365 W/kg; SAR(10 g) = 0.149 W/kg Maximum value of SAR (measured) = 0.439 W/kg Date: 2024/07/18 Test Laboratory: LCS-SAR Lab LTE B25 20M QPSK 1RB49 26590CH Rear side 0mm DUT: SFO1; Type: SFO1; Serial: A240603189-1 Communication System: UID 0, LTE-FDD (0); Frequency: 1905 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1905 MHz; σ = 1.429 S/m; ε r = 40.592; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.85, 7.85, 7.85); Calibrated: 2023/11/23;  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix C Calibration certificate 1. Dipole D750V3-SN 1191(2023-06-15) D835V2-SN 4d124(2023-10-24) D1750V2-SN 1035(2023-06-12) D1900V2-SN 5d055 (2023-10-20) D2450V2-SN 808(2023-10-23) D2600V2-SN 1071(2023-06-20) D5GHzV2-SN 1046(2023-10-23) 2. DAE DAE3-SN 373(2024-1-3) 3. Probe EX3DV4-SN 3805(2023-11-23) Page 2 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 3 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 4 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 6 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 7 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 9 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 10 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 12 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 13 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 14 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 15 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 16 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: webmas…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 36 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 37 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 38 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 39 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 40 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 41 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 42 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 43 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 44 of 58 FCC ID: 2A7UQ-SFO1 Report No.: LCSA06124086EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Building A and 301 Building C, Juji Industrial Park, Yabianxueziwei Shajing Street, Baoan District, Shenzhen, 518000, P.R.C. Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 45 of 58 FCC ID: 2A7UQ-SFO1 Report No.:…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Roelant Prins
[email protected]31621161626Fax: 31621161626

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.83 GHz20.80 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is average conducted. This device supports 802.11a, 802.11n and 802.11ac with a 20 MHz, 40 MHz and 80 MHz bandwidth mode. For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used at a minimum distance of 0 mm from the body. The highest reported SAR for body-worn use conditions is 0.67 W/kg.

Other Applications from Adyen N.V.

Payment Terminal - FCC ID 2A7UQ-NYC1 - Adyen N.V.
2A7UQ-NYC1

Payment Terminal

Jan 08, 2023

Equipment Class

DTS - Digital Transmission System