Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ComponentCompanyDescriptionPart numberSpecsLink / Document PCBA 3.0Medesto Controls the power to the components using custom written firmware LB100-3000-0ANA• Schematics & BOM uploaded Wall TransformerAdaptor Tech Allows connection of external power supply to provide power to the dispenser LB7800-014-0A (ATS036T- W240U) • Voltage Type: DC • Operating Voltage: 24V • Amp: 1.5A http://www.adaptertech.com.tw/30-Watt- ATS030-Series.html?CID=2_1 • Spec sheet uploaded. LTE AntennaTE ConnectivityAntenna for cellular communicationLB5000-944-0A10W• Spec sheet uploaded SpeakerSheng JiaN/ALB5000-146-0A8Ω/ 2W• Spec sheet uploaded LEDTONGJIA5MM RGB Round LEDLB5000-945-0ACommon Anode / 5V• Spec sheet uploaded NFC CoilMolexReads NFC tags on podLB5000-936-0A13.56MHz• Spec sheet uploaded Rechargeable BatteryDTP Battery used to power PCBA when there is no power supply LB5000-940-0A3.7V / 3000mAh• Spec sheet uploaded PCBA Wall Transformer LED SPEAKER NFC Coil Button Trigger LTE Antenna Rechargeable Battery
MedestoConnect –MET Label September 19 th , 2022 MedestoConnect -MET Label and Location A Precision Digital Pharmacy2 The FCC ID for the device and other components that it contains can be located on the bottom of the device. The MET Label information can be found on Page 7 in the MedestoConnect User Guide FCC ID: 2A8H7-LB300-5000 CONTAINS FCC ID: 2AC72-ESPWROOM32 AND XMR2020BG95M1 FCC TESTING WAS CONDUCTED AFTER ASSEMBLY
[Type here] Connect Description The Medesto Connect is an FDA Class 1 medical device capable of providing audible alerts and reminders for pre-determined medication dosing schedules. The Medesto Connect identifies the medication being managed by the patient through scanning an NFC tag on the outside of the medicine container. The Connect is capable of interacting with IoT devices via Bluetooth to help record a patient’s scheduled activities and usages. The Connect also communicates via Wi-Fi (802.11 bgn) and LTE (Cat M1) to help track and record a patient’s schedule and activities. This device has been tested and found to comply with Part 15 Class B of the FCC Rules. Overview Parameter Min Typ Max Units Certification / Standard Dimensions 4.5 x 4.5 x 2.5 in Power Supply 24 V UL E225703 / RoHS R33154 1.5 A LTE 698-960 1710-2700 MHz FCC ID: XMR2020BG95M1 -2.0 4.0 dBi Wi-Fi (2.4GHz) / Bluetooth (V4.2) 2402 2480 MHz FCC ID: 2AC7Z-ESP32WROOM32E Speaker 8 Ω IEC-60268-5 2 W NFC 13.56 MHz FCC ID: TBD Rechargeable Battery 3.7 V UN38.3 UL62133 3000 mAh
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 FF EE DD CC BB AA Medesto-PCBA3.0-V3.3 PCB1 FD2FD3FD4 FD5 Notes (unless otherwise s pecified): 1. All resistors are 1%. 2. Board operating temperature is 0°C to 50°C. 3. Capacitors and resistors are 0603 unless noted (termination resistors and BGA capacitors are 0402). 4. Text in italic placed on a wire doesn't correspond to net name. It just helps to identify rapidly MCU IO related to this wire. 5. 10 mil PCB Layout clearance for Critical circuit section. Medesto-PCBA3.0-V3.0 FD6 1. Title 2. Block Diagram 3. Power Management 4. Battery Charger 5. MCU 6. Stepper Motor Driver 7. Solenoid Driver 8. Sensor 9.UserInterface 10. SD Card 11. WiFi 12. NFC 13. Audio 14. LTE CAT M1 15. Extension Connector V1.1 Change logs: 1. Change the size of MH5 to D3.81mm for the bracket. 2. Change the C10 to a smaller size capacitor - UCL1V221MNL1GS 3. Change the L2 to a smaller size inductor - NS10155T6R8NNA. 4. Change CN2 to a vertical connector. 5. Change CN17 to a SMD connector. 6. Correct 3.3V Power rail on LTE Page. 7. Change CN9, CN10 to smaller size connector - B4B-PH-K-S(LF)(SN) 8. Change CN13, CN14 to smaller size connector - B2B-PH-K-S(LF)(SN) 9. Removed Testing points from TP40 to TP51, merge the signals into CN17 and change CN17 to 20 PINs connector - 0878325922 10. Change CN18 to smaller size connector - B7B-PH-K-S(LF)(SN) 11. Swap signals on U6 and CN17 for better PCB routing V1.2 Change logs: 1. Change Mounting holes to Non-plated and remove the GND 2. Swapp PIN1 and PIN2 on CN1 3. Change R2 to R3 in design note of U1 V2 Change logs: 1. Change CN13 to Molex 5055680271 2. Correct SCI5 and SCI8 naming. 3. Change U6 to R7FA6M3AH3CFP#AA0 V2.1 Change logs: 1. Change F1 to 0685T2000-01 2. Change U8 to ESP32-WROOM-32E(8MB) 3. DNP U9 4. Change the connector to match serial port (follow ESP-PROG pinout) 5. Remove Jtag test points 6. Add CLI passthrough Tx/Rx test points 7. Add SCI2 tx and rx test points V2.6 Change logs: 1. Changed title bock 2. Updated Silk screen V3.0 Change logs: 1. The programming ports are on bottom 2. Battery connector is flipped 180 V3.2 Change logs: 1. Changes solder mask bridge and Layer Stack as per Fabricator's requirement 2. Update pannel placement and Gerber file V3.3 Change logs: 1. IR sensor current limiting resistor reduced 2. IR sensor collector resistor reduced 3. Cell sensor current limiting resistor reduced 4. Cell sensor collector resistor reduced 3.20 mm MH1 Mounting_Hole_NPTH 3.20 mm MH2 Mounting_Hole_NPTH 3.20 mm MH3 Mounting_Hole_NPTH 3.20 mm MH4 Mounting_Hole_NPTH 3.81 mm MH5 Mounting_Hole_NPTH FD1 G3.5 DispenserLB100-3000-0A - PCBA 3.0ANSI A Perigon Health 360 340 N Main Street Plymouth, MI 48170 This drawing is pro perty of Perigon Health 360 LLC, any distibution or transmission of this do cument requires written permission from Perigon Health 360. Title: Medesto-PCBA3.0-V3.3 Project:Size:Perigon #: Date: 6/21/202212:19:35 PM Page: 115 of Designed By:Approved By: AU , JWJG Four holes (MH1 - 4) for #3 machine screws and washers COFD1 COFD2 COFD3 COFD4 COFD5 COFD6 PIMH101 COMH1 PIMH201 COMH2 PIMH301 COMH3 PIMH401 COMH4 PIMH501 COMH5 COPCB1 PIMH101 PIMH201 PIMH301 PIMH401 PIMH501 1 1 2 2 3 3 4 4 5 5 6 6 DD CC BB AA Perigon Health 360 340 N Main Street Plymouth, MI 48170 This drawing is pro perty of Perigon Health 360 LLC, any distibution or transmission of this do cument requires written permission from Perigon Health 360. Title: Medesto-PCBA3.0-V3.3 Project:Size:Perigon #: Date: 6/21/202212:19:35 PM Page: 215 of Designed By:Approved By: AU , JWJG G3.5 DispenserLB100-3000-0A - PCBA 3.0ANSI A 1 1 2 2 3 3 4 4 5 5 6 6 DD CC BB AA GNDGNDGND 10uF 50V 1210 C1 GNDGND 24V_IN5V_SYS GND 10uF 50V 1210 C2 1uF 50V 1206 C3 GNDGND 24V 100k R4 10k R6 GND Monitor24v 5V 100k R5 GND Monitor5v 100k R7 5V 10uF 16V 0805 C12 GNDGNDGNDGNDGND 3.3V 24V 5V3.3V TP1 Max Current 3A Max Current 1.5A GND TP3TP4 TP6 5V GNDGNDGNDGNDGND LTE_3.3VMax Current 1.5A IN 1 G N D 4 OUT 3 AP7363-33D-13U3 LTE_3.3V TP2 100pF 50V C6 158k R1 GND 22uF 25V 1206 C8 FB 1 EN 2 VIN 3 G N D 4 SW 5 BST 6 AP63301WU-7U1 24V 0.1uF 50V C4 22uF 25V 1206 C9 Jig Test Points VBAT TP5 12 SS210-LTPD1 0.1uF 50V C5 0.1uF 50V C7 0.1uF 50V C14 10uF 16V 0805 C15 10uF 16V 0805 C16 0.1uF 50V C18 10uF 16V 0805 C19 0.1uF 50V C20 0.1uF 50V C21 0.1uF 50V C13 0.1uF 50V C17 i Clearance 742792040 L3 742792040 L4 Monitor24vMonitor5v 30k R3 2.2R R2 1uF 50V C11 S M A J 2 4 C A - 1 3 - F D2 24VDC IN Max Current 1.5A TP53 TP52 6.8uH 4.98A L223 41 ACP3225-501-2P-T000 L1 220uF 35V C10 1 2 B2B-XH-A(LF)(SN) CN1 0685T2000-01 F1 Perigon Health 360 340 N Main Street Plymouth, MI 48170 This drawing is pro perty of Perigon Health 360 LLC, any distibution or transmission of this do cument requires written permission from Perigon Health 360. Title: Power Project:Size:Perigon #: Date: 6/21/202212:19:35 PM Page: 315 of Designed By:Approved By: AU , JWJG G3.5 DispenserLB100-3000-0A - PCBA 3.0ANSI A IN 1 G N D 4 OUT 3 AP7363-33D-13U2 Switching Frequency: 500kHz Vout = 0.8 x (R1/R3 + 1) = 5.013V PIC101 PIC102 COC1 PIC201 PIC202 COC2 PIC301 PIC302 COC3 PIC401 PIC402 COC4 PIC501 PIC502 COC5 PIC601 PIC602 COC6 PIC701 PIC702 COC7 PIC801 PIC802 COC8 PIC901 PIC902 COC9 PIC1001 PIC1002 COC10 PIC1101 PIC1102 COC11 PIC1201 PIC1202 COC12 PIC1301 PIC1302 COC13 PIC1401 PIC1402 COC14 PIC1501 PIC1502 COC15 PIC1601 PIC1602 COC16 PIC1701 PIC1702 COC17 PIC1801 PIC1802 COC18 PIC1901 PIC1902 COC19 PIC2001 PIC2002 COC20 PIC2101 PIC2102 COC21 PICN101 PICN102 COCN1 PID101 PID102 COD1 PID201 PID202 COD2 PIF101 PIF102 COF1 PIL101 PIL102 PIL103 PIL104 COL1 PIL201 PIL202 COL2 PIL301 PIL302 COL3 PIL401 PIL402 COL4 PIR101 PIR102 COR1 PIR201 PIR202 COR2 PIR301 PIR302 COR3 PIR401 PIR402 COR4 PIR501 PIR502 COR5 PIR601 PIR602 COR6 PIR701 PIR702 COR7 PITP101 COTP1 PITP201 COTP2 PITP301 COTP3 PITP401 COTP4 PITP501 COTP5 PITP601 COTP6 PITP5201 COTP52 PITP5301 COTP53 PIU101 PIU102 PIU103 PIU104 PIU105 PIU106 COU1 PIU201 PIU203 PIU204 COU2 PIU301 PIU303 PIU304 COU3…
Text truncated - open the document above for the full version.
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 FF EE DD CC BB AA Medesto-PCBA3.0-V3.3 PCB1 FD2FD3FD4 FD5 Notes (unless otherwise s pecified): 1. All resistors are 1%. 2. Board operating temperature is 0°C to 50°C. 3. Capacitors and resistors are 0603 unless noted (termination resistors and BGA capacitors are 0402). 4. Text in italic placed on a wire doesn't correspond to net name. It just helps to identify rapidly MCU IO related to this wire. 5. 10 mil PCB Layout clearance for Critical circuit section. Medesto-PCBA3.0-V3.0 FD6 1. Title 2. Block Diagram 3. Power Management 4. Battery Charger 5. MCU 6. Stepper Motor Driver 7. Solenoid Driver 8. Sensor 9.UserInterface 10. SD Card 11. WiFi 12. NFC 13. Audio 14. LTE CAT M1 15. Extension Connector V1.1 Change logs: 1. Change the size of MH5 to D3.81mm for the bracket. 2. Change the C10 to a smaller size capacitor - UCL1V221MNL1GS 3. Change the L2 to a smaller size inductor - NS10155T6R8NNA. 4. Change CN2 to a vertical connector. 5. Change CN17 to a SMD connector. 6. Correct 3.3V Power rail on LTE Page. 7. Change CN9, CN10 to smaller size connector - B4B-PH-K-S(LF)(SN) 8. Change CN13, CN14 to smaller size connector - B2B-PH-K-S(LF)(SN) 9. Removed Testing points from TP40 to TP51, merge the signals into CN17 and change CN17 to 20 PINs connector - 0878325922 10. Change CN18 to smaller size connector - B7B-PH-K-S(LF)(SN) 11. Swap signals on U6 and CN17 for better PCB routing V1.2 Change logs: 1. Change Mounting holes to Non-plated and remove the GND 2. Swapp PIN1 and PIN2 on CN1 3. Change R2 to R3 in design note of U1 V2 Change logs: 1. Change CN13 to Molex 5055680271 2. Correct SCI5 and SCI8 naming. 3. Change U6 to R7FA6M3AH3CFP#AA0 V2.1 Change logs: 1. Change F1 to 0685T2000-01 2. Change U8 to ESP32-WROOM-32E(8MB) 3. DNP U9 4. Change the connector to match serial port (follow ESP-PROG pinout) 5. Remove Jtag test points 6. Add CLI passthrough Tx/Rx test points 7. Add SCI2 tx and rx test points V2.6 Change logs: 1. Changed title bock 2. Updated Silk screen V3.0 Change logs: 1. The programming ports are on bottom 2. Battery connector is flipped 180 V3.2 Change logs: 1. Changes solder mask bridge and Layer Stack as per Fabricator's requirement 2. Update pannel placement and Gerber file V3.3 Change logs: 1. IR sensor current limiting resistor reduced 2. IR sensor collector resistor reduced 3. Cell sensor current limiting resistor reduced 4. Cell sensor collector resistor reduced 3.20 mm MH1 Mounting_Hole_NPTH 3.20 mm MH2 Mounting_Hole_NPTH 3.20 mm MH3 Mounting_Hole_NPTH 3.20 mm MH4 Mounting_Hole_NPTH 3.81 mm MH5 Mounting_Hole_NPTH FD1 G3.5 DispenserLB100-3000-0A - PCBA 3.0ANSI A Perigon Health 360 340 N Main Street Plymouth, MI 48170 This drawing is pro perty of Perigon Health 360 LLC, any distibution or transmission of this do cument requires written permission from Perigon Health 360. Title: Medesto-PCBA3.0-V3.3 Project:Size:Perigon #: Date: 6/21/202212:19:35 PM Page: 115 of Designed By:Approved By: AU , JWJG Four holes (MH1 - 4) for #3 machine screws and washers COFD1 COFD2 COFD3 COFD4 COFD5 COFD6 PIMH101 COMH1 PIMH201 COMH2 PIMH301 COMH3 PIMH401 COMH4 PIMH501 COMH5 COPCB1 PIMH101 PIMH201 PIMH301 PIMH401 PIMH501 1 1 2 2 3 3 4 4 5 5 6 6 DD CC BB AA Perigon Health 360 340 N Main Street Plymouth, MI 48170 This drawing is pro perty of Perigon Health 360 LLC, any distibution or transmission of this do cument requires written permission from Perigon Health 360. Title: Medesto-PCBA3.0-V3.3 Project:Size:Perigon #: Date: 6/21/202212:19:35 PM Page: 215 of Designed By:Approved By: AU , JWJG G3.5 DispenserLB100-3000-0A - PCBA 3.0ANSI A 1 1 2 2 3 3 4 4 5 5 6 6 DD CC BB AA GNDGNDGND 10uF 50V 1210 C1 GNDGND 24V_IN5V_SYS GND 10uF 50V 1210 C2 1uF 50V 1206 C3 GNDGND 24V 100k R4 10k R6 GND Monitor24v 5V 100k R5 GND Monitor5v 100k R7 5V 10uF 16V 0805 C12 GNDGNDGNDGNDGND 3.3V 24V 5V3.3V TP1 Max Current 3A Max Current 1.5A GND TP3TP4 TP6 5V GNDGNDGNDGNDGND LTE_3.3VMax Current 1.5A IN 1 G N D 4 OUT 3 AP7363-33D-13U3 LTE_3.3V TP2 100pF 50V C6 158k R1 GND 22uF 25V 1206 C8 FB 1 EN 2 VIN 3 G N D 4 SW 5 BST 6 AP63301WU-7U1 24V 0.1uF 50V C4 22uF 25V 1206 C9 Jig Test Points VBAT TP5 12 SS210-LTPD1 0.1uF 50V C5 0.1uF 50V C7 0.1uF 50V C14 10uF 16V 0805 C15 10uF 16V 0805 C16 0.1uF 50V C18 10uF 16V 0805 C19 0.1uF 50V C20 0.1uF 50V C21 0.1uF 50V C13 0.1uF 50V C17 i Clearance 742792040 L3 742792040 L4 Monitor24vMonitor5v 30k R3 2.2R R2 1uF 50V C11 S M A J 2 4 C A - 1 3 - F D2 24VDC IN Max Current 1.5A TP53 TP52 6.8uH 4.98A L223 41 ACP3225-501-2P-T000 L1 220uF 35V C10 1 2 B2B-XH-A(LF)(SN) CN1 0685T2000-01 F1 Perigon Health 360 340 N Main Street Plymouth, MI 48170 This drawing is pro perty of Perigon Health 360 LLC, any distibution or transmission of this do cument requires written permission from Perigon Health 360. Title: Power Project:Size:Perigon #: Date: 6/21/202212:19:35 PM Page: 315 of Designed By:Approved By: AU , JWJG G3.5 DispenserLB100-3000-0A - PCBA 3.0ANSI A IN 1 G N D 4 OUT 3 AP7363-33D-13U2 Switching Frequency: 500kHz Vout = 0.8 x (R1/R3 + 1) = 5.013V PIC101 PIC102 COC1 PIC201 PIC202 COC2 PIC301 PIC302 COC3 PIC401 PIC402 COC4 PIC501 PIC502 COC5 PIC601 PIC602 COC6 PIC701 PIC702 COC7 PIC801 PIC802 COC8 PIC901 PIC902 COC9 PIC1001 PIC1002 COC10 PIC1101 PIC1102 COC11 PIC1201 PIC1202 COC12 PIC1301 PIC1302 COC13 PIC1401 PIC1402 COC14 PIC1501 PIC1502 COC15 PIC1601 PIC1602 COC16 PIC1701 PIC1702 COC17 PIC1801 PIC1802 COC18 PIC1901 PIC1902 COC19 PIC2001 PIC2002 COC20 PIC2101 PIC2102 COC21 PICN101 PICN102 COCN1 PID101 PID102 COD1 PID201 PID202 COD2 PIF101 PIF102 COF1 PIL101 PIL102 PIL103 PIL104 COL1 PIL201 PIL202 COL2 PIL301 PIL302 COL3 PIL401 PIL402 COL4 PIR101 PIR102 COR1 PIR201 PIR202 COR2 PIR301 PIR302 COR3 PIR401 PIR402 COR4 PIR501 PIR502 COR5 PIR601 PIR602 COR6 PIR701 PIR702 COR7 PITP101 COTP1 PITP201 COTP2 PITP301 COTP3 PITP401 COTP4 PITP501 COTP5 PITP601 COTP6 PITP5201 COTP52 PITP5301 COTP53 PIU101 PIU102 PIU103 PIU104 PIU105 PIU106 COU1 PIU201 PIU203 PIU204 COU2 PIU301 PIU303 PIU304 COU3…
Text truncated - open the document above for the full version.
Conducted Emissions Frequency Stability (Internal Chamber View) Frequency Stability (External Chamber View) Radiated Emissions Below 30MHz Radiated Emissions Above 30MHz
340 N Main St., Suite 300 · Plymouth, Michigan · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |

Solid medication / supplement dispenser
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter