Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
[Cover] [Brand LOGO] Emay Plus [产品名称] Emay Plus ZERO-FAT 塑身仪 Emay Plus ZERO-FAT 塑身儀 Emay Plus ZERO-FAT Body Slim [产品型号] EP-601 [Icon or Photo] User Manual Please read this user manual carefully before use and keep it properly for future reference. Contents Safety Precautions.......................................................................................... Product Introduction································································································································· Product Structure........................................................................................................................... Product Specification........................................................................................................................ How to Use.............................................................................................................................. Cleaning, Maintenance and Storage.......................................................................................... Causes and Troubleshooting......................................................................................................... Product Warranty.............................................................................................................................. Safety Precautions Please read and follow the safety precautions carefully before use. Improper operation might pose a risk to personal safety and property damage. Do not use the product for other purposes other than as directed. 【DANGER】 1.Do not use the product on the head, eye area, laryngeal prominence or area of chest and back area near to the heart. 2.Stop using the product immediately if you feel any discomfort, and consult your physician for guidance. 3.The product is not intended for use by persons: a)Under 14 years old; b)Pregnant, lactating and menstrual women; c)Have reduced physical, sensory or mental capabilities; d)Feeling unwell or undergoing medical treatment; e)Have or are undergoing medical electronic equipment (eg, cardiac pacemaker, artificial heart-lung or implantable medical devices); f)Have or are undergoing wearable medical electronic device (eg, ECG scanner); g)Have chronic diseases, heart disease, cancer and tumor etc; h)Have low immunity caused by immunosuppressive diseases, or taking drugs of immunodepressants; i)Have hypersensitive skin, contact dermatitis or skin disease; j)Light sensitive or taking prescription medicine of isoflavones; k)Have undergone surgical operation, laser minimally invasive operation, cuticle removal on the treatment area for the last 3 months. * Please consult your health care physician directly before using the product if you are not sure of the conditions. 4.The electrode plate on the middle part of main unit will generate heating during working. Be careful to use the product if you are not sensitive to heat. Do not stay on the same treatment area for too long to avoid scald. 5.Do not treat the same area for too long when using BURN mode. Make sure the treatment head is in close contact with your skin and moves slowly to avoid scald. 6.Do not use the product while driving or while concentrating on work. 7.Do not disassemble, repair or modify this product. Improper handling might lead to fire, electric shock, injury or product malfunction. Unauthorized disassembly or modification may result in exclusion from the warranty. 【WARNING】 1.The product is for personal care only, not medical device. Do not use the product for other medical purposes. 2.Do not use the product in conjunction with other medical devices. 3.Do not rinse the product in water while using. 4.Remove metal jewelry (eg. necklaces, rings, watches, earrings) before using the product to avoid possible strong electric shock from contact between metal part of jewelry and electrode of the main unit. 5.Do not look at LED light for a long time to avoid eye injury. 6.Do not use the product on below area: a)Area with plastic surgery; b)Injured and not fully healed area like abrasion, scratch and scald; c)Area of skin inflammation caused by abscess, rash and sunburn; d)Area of erythema caused by itching or physical stimulation; e)Area with implanted metal, silicone, introducer in body, face and mouth; f)Area with tattoo or artistic make-up. 7.The product can be used by person aged from 14 years and above, and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the product in a safe way and understand the hazards involved. Children shall not play with the product. Cleaning and user maintenance shall not be made by children without supervision. 8.Do not remove the built-in rechargeable battery. Do not charge or use the product with high temperature. Follow local government laws and regulations for proper disposal of battery. Please recycle battery if possible. Do not heat battery or device containing battery into fire. 9.The product should be charged with an approved safety isolation adapter with the output capacity of DC 5.0V/2.0A and complied with IEC/EN 60335-1. 10.Make sure your hands are dry before touching the plug of USB charging cable or power adapter to avoid electric shock. 11.Do not place any object on the surface of USB cable during charging to avoid malfunction or fire. Please switch off immediately and remove USB plug if any failure occurs to avoid electric shock or fire. 12.Make sure USB plug or power adapter is inserted properly to avoid possible electric shock and fire. 【CAUTION】 1.Keep the product out of reach of children and pets while using. 2.Start from low intensity level for initial use, and increase intensity level gradually if you are accustomed to the product. 3.Keep the product away from heat source, open flame nor place it in a room with high temperature. Do not expose the product to the sun or rain. 4.Do not use the product close …
Text truncated - open the document above for the full version.
EMAY GLOBAL LIMITED Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 9/26/2023 U.S. Agent Designation EMAY GLOBAL LIMITED acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2A8QU-EP601): Name and company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of EMAY GLOBAL LIMITED. EMAY GLOBAL LIMITED with the FRN 0032898512 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. S incerely, Signature Lucas Au Operation Director EMAY GLOBAL LIMITED Signature Tim Payne Manager FCC US Agent, LLC 48_[model] US_Agent_2.911(d)(7)-U, V05
Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: EMAY GLOBAL LIMITED Address: 1/F., Centre 600, 82 King Lam Street Cheung Sha Wan., Kowloon, Hong Kong, China Phone: +852-23120982 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-09-26 Name / Title: Lucas Au / Operation Director Company: EMAY GLOBAL LIMITED Address: 1/F., Centre 600, 82 King Lam Street Cheung Sha Wan., Kowloon, Hong Kong, China Phone: +852-23120982 Fax: +852-23120982 E-Mail: [email protected]
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2A8QU-EP601 EP-601 We, applicant Company Name: EMAY GLOBAL LIMITED Address: 1/F., Centre 600, 82 King Lam Street Cheung Sha Wan., Kowloon, Hong Kong, China Phone: +852-23120982 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-09-26 Name / Title: Lucas Au / Operation Director Company: EMAY GLOBAL LIMITED Address: 1/F., Centre 600, 82 King Lam Street Cheung Sha Wan., Kowloon, Hong Kong, China Phone: +852-23120982 Fax: +852-23120982 E-Mail: [email protected]
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2A8QU-EP601 EP-601 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-09-26 Name / Title: Lucas Au / Operation Director Company: EMAY GLOBAL LIMITED Address: 1/F., Centre 600, 82 King Lam Street Cheung Sha Wan., Kowloon, Hong Kong, China Phone: +852-23120982 Fax: +852-23120982 E-Mail: [email protected]
Page 1 of 4 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8
Page 1 of 1 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L: 2.0cm x W: 2.0cm) Label Location
Page 1 of 6 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 6 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 6 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 6 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Antenna Page 5 of 6 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 6 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12
Page 1 of 3 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information FCC ID : 2A8QU-EP601 Product name : Emay Plus ZERO-FAT Body Slim Test Model : EP-601 Power Supply : Input: DC 5V, 2A Battery: DC 7.4V, 1000mAh Hardware Version : Version 1.0 Software Version : Version 1.0 Bluetooth : 2402MHz ~ 2480MHz Channel Number : 40 channels for Bluetooth V5.1 (DTS) Channel Spacing : 2MHz for Bluetooth V5.1(DTS) Modulation Type : GFSK for Bluetooth V5.1 (DTS) Bluetooth Version : V5.1 Antenna Type : PCB Antenna Antenna Gain : -0.58dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below Page 2 of 3 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Page 3 of 3 FCC ID:2A8QU-EP601 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. Conducted Power Results <BT LE> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 -0.25 19 2440 0.04 39 2480 0.06 5. Manufacturing Tolerance <BT LE> GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 6. Evaluation Results 6.1 Standalone Evaluation Band/Mode f (GHz) Antenna Distance (mm) RF output power SAR Test Exclus…
Text truncated - open the document above for the full version.
Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Center Frequency Horizontal Vertical 2400MHz 2400MHz 2500MHz 2400MHz 2400MHz 2500MHz -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dB Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 27.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (m m ) Address Kexing Road, Xiangzhou District, Zhuhai, China No. 333 Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.
Page 1 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BLE (Conducted Measurement) Product Name: Emay Plus ZERO-FAT Body Slim Test Model: EP-601 Environmental Conditions Temperature: 23.8 C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Nick Peng Supervised by: Kay Hu Page 2 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT BLE 2402 Ant 0.692 0.5 Pass NVNT BLE 2440 Ant 0.686 0.5 Pass NVNT BLE 2480 Ant 0.714 0.5 Pass Page 3 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT BLE 2402MHz Ant -6dB Bandwidth NVNT BLE 2440MHz Ant Page 4 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT BLE 2480MHz Ant Page 5 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT BLE 2402 Ant -0.25 30 Pass NVNT BLE 2440 Ant 0.04 30 Pass NVNT BLE 2480 Ant 0.06 30 Pass Page 6 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT BLE 2402MHz Ant Power NVNT BLE 2440MHz Ant Page 7 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT BLE 2480MHz Ant Page 8 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 2402 Ant -15.49 8 Pass NVNT BLE 2440 Ant -16.32 8 Pass NVNT BLE 2480 Ant -15.23 8 Pass Page 9 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT BLE 2402MHz Ant PSD NVNT BLE 2440MHz Ant Page 10 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT BLE 2480MHz Ant Page 11 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.4 Band Edge Condition Mode Frequency (MHz) Antenna Max Value (dBc) Limit (dBc) Verdict NVNT BLE 2402 Ant -56.82 -20 Pass NVNT BLE 2480 Ant -57.65 -20 Pass Page 12 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Band Edge NVNT BLE 2402MHz Ant Ref Band Edge NVNT BLE 2402MHz Ant Emission Page 13 of 23 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Band Edge N…
Text truncated - open the document above for the full version.
Page 1 of 34 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Emay Global Limited Emay Plus ZERO-FAT Body Slim Test Model: EP-601 Prepared for : Emay Global Limited Address : 1st Floor, Centre 600, 82 King Lam Street, Cheung Sha Wan, Kowloon, Hong Kong Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : September 15, 2023 Number of tested samples : 2 Sample No. : A09143021-1, A09143021-2 Serial number : Prototype Date of Test : September 15, 2023 ~ September 21, 2023 Date of Report : September 21, 2023 Page 2 of 34 FCC ID:2A8QU-EP601 Report No.: LCSA09143021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA09143021EA Date of Issue ................................... : September 21, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : Emay Global Limited Address ........................................... : 1st Floor, Centre 600, 82 King Lam Street, Cheung Sha Wan, Kowloon, Hong Kong Test Specification Standard ...............…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |

Emay Plus Dual Lifting Face Slimmer
Equipment Class
DTS - Digital Transmission System