2A92I-AST-WR234WIRELESS CHARGER

NINGBO ALLSTAR IMPORT&EXPORT CO.,LTD
WIRELESS CHARGER - FCC ID 2A92I-AST-WR234 - NINGBO ALLSTAR IMPORT&EXPORT CO.,LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 09, 2024
Application Purpose
Original Equipment
Date of Application
Jan 09, 2024
Equipment Note
WIRELESS CHARGER
Frequency Range
0.11150000 - 0.20500000
Company
NINGBO ALLSTAR IMPORT&EXPORT CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Redi iWatch USB Charger Instruction Manual SM-2840 AST-WR234 1 x iWatch USB Charger Type-C/USB-A Input: DC 5V/1A Wireless Output(iWatch): 2W(max.) Connect the USB-A Input Port (4) to a USB-A AC adapter or Insert the Type-C tip of a cable into Type-C input port (3); The LED indicator (5) will illuminate RED once the connection is established. Position the iWatch on the designated area of the wireless charging pad (2). The iWatch will automatically secure itself to the pad, triggering the LED to switch to a BLUE light indicating the iWatch is now in the process of charging. 2. 1. 1. 2. 3. 4. 5. • • Silicone Strap WirelessCharging Pad Surface LED Indicator Type-C Input Port USB-A Input Port What’s included: Functions: Instructions: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Warning: approved by the party responsible for compliance could void the user’s authority to operate the equipment. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located for operating in conjunction with any other antenna or transmitter. (1) (2) * tnemetatS erusopxE noitaidaR CCF:tnemetatS CCF WARNING-When using this product, basic precautions should always be followed: Read all the instructions before use. Never store or use this product in temperatures below 32°F(0°C) or above 115°F(45°C). Do not overcharge your iWatch. The unit may become hot under excessive use. Remove your iWatch once it is fully chargecd. Never charge your iWatch for more than 7 hours at a time. To reduce the risk of injury, close supervision is required when the product is used near children. Do not expose the device to moisture. Do not use the device in excess of its output rating. Overload outputs above the Do not use the device if damaged or explosion or risk of injury. Do not disassemble the device. For professional. incorrect reassembly may or temperatures above 104°F may cause explosion. To ensure product safety, ensure that identical replacement parts. Attachments on the back of your device can impede the effectiveness of the wireless charger, and lead to overheating. You must remove attachments from the phone before charging on this device. This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment the interference by one or more of the following measures: Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/ TV technician for help. • 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. SAFETY PRECAUTIONS: Note : C170910 Paper from responsibl e sources Made in China FCC ID: 2A92I-AST-WR234 Name of the Distributor: Bulletline Inc Address of the Distributor: 6301 East 10th Avenue, Suite 110 Hialeah, FL 33013 USA. WWW.PCNA.COM 170x90mm C170910 Paper from responsibl e sources 31.2mm 20mm

Attestation Statements

NINGBOALLSTARIMPORT&EXPORTCO.,LTD 14-3-8,TIANHONGBUILDING,NO.1SHUNYESTREET,LUOTUO STREET,ZHENHAIDISTRICT,NINGBOCITY,ZHEJIANG Tel.:0086-574-86307008Fax:0086-574-86307009 CoveredEquipmentCertificationAttestationLetter 11/30/2023 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA ATTN.:ReviewingEngineer FCCID:2A92I-AST-WR234 NINGBOALLSTARIMPORT&EXPORTCO.,LTDcertifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivingan equipmentauthorizationpursuanttosection2.903oftheFCCrules. Note:Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedby anyoftheentitiesidentifiedonthecurrentCoveredList,theapplicantshould includeanexplanationonwhytheequipmentisnot“covered”equipment. NINGBOALLSTARIMPORT&EXPORTCO.,LTDcertifiesthat,asofthedateofthe filingoftheapplication,theapplicantisnotidentifiedontheCoveredListasanentity producing“covered”equipment. Signed: Printedname:CarrieJin Title:SalesManager CompanyName:NingboAllstarImport&ExportCo.,Ltd Date:2023.11.30

Attestation Statements

NINGBO ALLSTAR IMPORT & EXPORT CO.,LTD 14-3-8,TIANHONG BUILDING,NO.1 SHUNYE STREET,LUOTUO STREET,ZHENHAI DISTRICT,NINGBO CITY,ZHEJIANG Tel.: 0086-574-86307008 Fax: 0086-574-86307009 * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 11/30/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2A92I-AST-WR234 FRN of Grantee: 0033275272 Per section 2.911(d)(7) of the FCC rules, NINGBO ALLSTAR IMPORT & EXPORT CO., LTD certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Stariver Consulting Company FCC Registration Number (FRN): 0033400433 Company Address: 2363 James St #1098 Syracuse, NY 13206, USA Agent Name: Chong He Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed: Signed: Signed: Printed name: Carrie Jin Printed name: Chong He Title: Sales Manager Title: Manager Company Name: Ningbo Allstar Import & Export Co.,Ltd Company Name: Stariver Consulting Company Date: 11/30/2023 Date: 1/10/2024

Cover Letter(s)

January 08, 2024 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China. (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with NINGBO ALLSTAR IMPORT & EXPORT CO., LTD / 14-3-18, TIANHONG BUILDING, NO.1 SHUNYE STREET, LUOTUO STREET, ZHENHAI DISTRICT, NINGBO CITY, ZHEJIANG PROVINCE,315200, CHINA <Signature>: Name:Carrie Jin Title:Sales Manager Company:NINGBO ALLSTAR IMPORT & EXPORT CO., LTD

Cover Letter(s)

January 08, 2024 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2A92I-AST-WR234 Product Name: WIRELESS CHARGER Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name:Carrie Jin Title:Sales Manager Company:NINGBO ALLSTAR IMPORT & EXPORT CO., LTD

ID Label/Location Info

Silking Printing Font: Arial Size: 22.2x41.6mm Color: Black Caution, Strong Magnets Scan for Instructions Item: SM-2840WH Model: AST-WR234 PO: M000036403 Type-C/USB-A Input: DC 5V/1A Wireless Output: 2W (max.) FCC ID: 2A92I-AST-WR234 Bulletline Inc.|Made in China

ID Label/Location Info

Label Location

RF Exposure Info

Rep Date The re This r reprod certifie SHEN conce In the remed 1 R §1 h u po Fre 0.3 3.0 30- 300 150 0.3 1.3 30- 300 150 f = * = No co an No ma be ort No.: TW e: 2023-12- eport refers only report is issued in duced rather in it ed copy there of NZHEN TIMEWAY erning the conten event of the imp dies which may b Requireme .1310: The uman expos ortable devic T equency ra (MHz) 3-3.0 0-30 -300 0-1500 00-100000 3-1.34 34-30 -300 0-1500 00-100000 frequency in = Plane-wave ote 1: Occu nsequence nd can exerc ote 2: Gene ay be expos e fully aware W2312019-H 15 to the sample te n confidence to t ts entirety or in p prepared by the AY TESTING LAB nts of the report. proper use of the be appropriate. ent e criteria lis sure to rad ces which s Table 1 to § ange Elec 614 1842/f 61.4 614 824/f 27.5 n MHz e equivalent upational/co of their em cise control eral popul a sed, or in w e of the pote H ested and does n he client and it w part and it may no SHENZHEN TIM BORATORIES. w e report. The SHE FC R sted in the dio frequenc shall be eva §1.1310(e)( ctric field s (V/m) (i) Limi f (ii) Limits fo power densit ontrolled ex mployment p over their e ation/uncont which perso ential for ex ot apply to the b will be strictly trea ot be used for ad MEWAY TESTIN will not, without th ENZHEN TIMEW C ID: 2A9 F Exposu following ta cy (RF) rad luated acco 1) - Limits trength M its for Occu 1. 4. 0. or General P 1. 2. 0. ty xposure lim provided th exposure. trolled expo ons who are xposure or c bulk. ated as such by t dverting. The clie NG LABORATOR he consent of the WAY TESTING LA 2I-AST-W re Evalua able shall b diation as s ording to the for Maximu Magnetic fi ( A upational/Co .63 .89/f .163 Population/U .63 .19/f .073 its apply in ose person osure limits e exposed a cannot exer the SHENZHEN nt to whom the r RIES. to his custo e client enter into ABORATORIES. R234 tion be used to specified in e provisions um Permis eld strengt A/m) ontrolled Exp Uncontrolled n situations ns are fully apply in s as a conseq cise control TIMEWAY TEST eport is issued m mer. Supplier or any discussion o reserves the righ evaluate th n §1.1307(b s of FCC pa ssible Expo thPower d (mW/ posure *(100) *(900/f 2 ) 1.0 f/300 5 d Exposure *(100) *(180/f 2 ) 0.2 f/1500 1.0 in which pe aware of th ituations in quence of t l over their e Page 1 o TING LABORATO may, however, sh r others persons of corresponden hts to withdraw it he environm b), except art 2.1091 o osure (MPE density /cm 2 ) Av ≤6 <6 <6 <6 <6 <30 <30 <30 <30 <30 ersons are he potential which the their employ exposure. of 5 ORIES.It may no how or send it . o directly concern e ce with any third and to adopt an ment impac in the case f this chapte E) veraging tim (minutes) 6 0 0 0 0 0 exposed a l for exposu general pu yment may ot be r a ed. party y other ct of e of er. me as a ure ublic not Rep Dat The r This be r e or a c conce any t In the other 2 T 3 T a. b. 2. 1 ce pe c. d. port No.: TW e: 2023-12- report refers only report is issued i eproduced rather certified copy the erned. SHENZHE hird party concer e event of the im r remedies which Test setup Test Proced The RF exp E and H-fie 1091-Mobile ntimeters is erson]”). The highe s The EUT w W2312019-H -15 y to the sample te n confidence to t in its entirety or ere of prepared b EN TIMEWAY TE rning the content proper use of the h may be appropr Left 2 0 dures posure test eld measure e conditions s normally m st emission was measure H ested and does n the client and it w in part and it ma by the SHENZHE ESTING LABOR ts of the report. e report. The SH riate. Z 0 cm 20 c Front was perfor ements sho s (“generally maintained level was r e ed accordin not apply to the b will be strictly trea ay not be used fo EN TIMEWAY TE ATORIES. will n o ENZHEN TIMEW Z axis 20 cm EUT cm t 20 c Bo t med in ane uld be made y be used in between the ecorded and ng to the dic bulk. ated as such by or adverting. The ESTING LABORA ot, without the co WAY TESTING L Rear 20 cm 20 m ttom choic cha m e with these n such a wa e RF source d compared ctates of KD the SHENZHEN client to whom t ATORIES. to his onsent of the clie ABORATORIES cm Righ M mber. e devices c ay that a se e's radiating d with limit. DB 680106 TIMEWAY TEST he report is issue customer. Suppli ent enter into any .reserves the righ ht M-0812 Prob onsidered t paration di s g structure(s D01 Wireles Page 2 TING LABORAT ed may, however ier or others pers y discussion of co hts to withdraw i be to meet the stance of at s) and [the ss Power T of 5 ORIES.It may no r, show or send i sons directly orrespondence w t and to adopt an § t least 20 nearest Transfer v04 ot t . with ny 4. Repo Date The re This re reprod certifie SHEN conce In the remed 4 E 1. 2. (e. 3.A loa tra clie co 4. (i. e exp 5. 20 de M P me axe dir an di s de be sh a co m a rad de th e 6.F str me ab th e po th e to st r be th r at ort No.: TW e: 2023-12- eport refers only eport is issued in duced rather in it ed copy there of NZHEN TIMEWAY rning the conten event of the imp dies which may b Equipment The power The output g., coil) is l e A client devi ad is placed ansmitter (i.e ent device e ntact) Only § 2 . 10 e., this provi posure con The E-field cm surrou n monstrated PE limit, per easurement es of the de ection of th d for three stance from cay is obs e used for te all be opera mpliance sc aximum field diating struc sign can sim eir nominal For systems ructure, the et when the sorbing ma e radiating s wer at the s e design allo be powered ructures are tested as w ree RF coils 15 W: in thi W2312019-H 15 to the sample te n confidence to th s entirety or in pa prepared by the Y TESTING LAB ts of the report. proper use of the be appropriate. t Approval Req u transfer fre power from ess than or ice providin d in physical e., the surfa enclosures 091-Mobile ision does n ditions). and H-field nding the de d to be less r KDB 4474 ts shall be t evice, with o e estimated points per a the emitter erved. Symm est reduction ated in docu cenarios (i.e …

Text truncated - open the document above for the full version.

Test Report

Report No.: TW2312019E Applicant: NINGBO ALLSTAR IMPORT & EXPORT CO., LTD Product: WIRELESS CHARGER Model No.: AST-WR234 Trademark: N/A Test Standards: FCC Part 15 Subpart C Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 Subpart C, for the evaluation of electromagnetic compatibility Approved By Terry Tang Manager Dated: December 15, 2023 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No: TW2312019E Page 2 of 29 Date: 2023-12-15 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 CAB identifier: CN0033 Report No: TW2312019E Page 3 of 29 Date: 2023-12-15 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details............................................................................................... 4 1.3 Description of EUT ........................................................................................... 4 1.4 Submitted Sample.............................................................................................. 5 1.5 Test Duration.................................................................................................... 5 1.6 Test Uncertainty................................................................................................. 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................ 7 5.0 Power Line Conducted Emission Test................................................................... 8 5.1 Schematics of the Test........................................................................................ 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT.................................................................................... 8 5.4 EUT Operating Condition.................................................................................... 9 5.5 Conducted Emission Limit................................................................................... 9 5.6 Test Result...................................................................................................... 9 6.0 Radiated Emission test...................................................................................... 12 6.1 Test Method and Test Procedure............................................................................ 12 6.2 Configuration of the EUT..................................…

Text truncated - open the document above for the full version.

Test Report

Fine Page 1 of 3 承 認 書 SPECIFICATION FOR APPROVAL 客 戶: CUSTOMER: 客 戶 料 號: CUST P/N: 松 岛 料 號: FINE P/N: 苹果手表发射线圈6.5uH 0.08*24P*12Ts软磁片 産 品 型 號: DESC: 日 期: DATE: 2023/11/17 版 本: Version: A.0 擬制 PREPARED BY 審核 CHECKED BY 批准 APPROVED BY 客戶承認 CUSTOMER APPROVE 黄燕铭 宁元安 黄锦华 深圳市松岛科技有限公司 工廠地址:东莞市东坑镇骏发三路123号三甲高新技术产业园2栋8楼 TEL:13728755750 FAX:0755-84526500 E-mail:[email protected] Fine Page 2 of 3 版本變更履歷 Version Change History 版本 Rev. 變 更 前 Before Change 變 更 後 After Change 更 改 日 期 Change Date 批 准 Approved By A.0 新发行 ---- 2018/03/09 黄锦华 Fine Page 3 of 3 SPECIFICATION 産 品 型 號: DESC 15*21.5-6.5uH-10MM-25C 版本 Rev:A.0 客戶CUST: XXX 客户料号CUST P/N: 一、尺寸DIMENSION:(mm) 二、原理图SCHEMATIC DIAGRAM: A 25±1 B 23.6±0.5 C 21.5±0.5 D 15±0.3 E 7.7±0.05 F 3±2 H 10±2 注: 1.交叉出线; 2.出线位置缠mm(ref)宽度高 温胶纸Ts; 3.线圈贴圆形软磁片两端带 缺口,磁片尺寸25±1mm,内孔 7.7mm,厚度为2.8±0.2mm。 4.装7.5*2.2mm,N52磁铁, 线圈面贴背胶 三、绕线参数Winding Specification: 序号 NO. 端子 TERMINAL 线径 WIRE 圈数 Turns 绕线方向 Winding Direction 1 S F 漆包线0.08*24P 12Ts CCW 四、电气特性ELECTRICAL CHARACTERISTICS: 温度TEMPERATURE:25±10°C, 湿度RELATIVE HUMIDITY:65±20% 序号 NO. 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TEST FREQUENCY 测试仪器 TEST EQUIPMENTS 1 IND. S-F 3.8uH ±10%单独线圈 1KHz/0.3V LCZ METER 1062B 2 IND. S-F 6.5uH ±10%单独线圈 1KHz/0.3V LCZ METER 1062B 3 DCR S-F ≤125mΩ 1KHz/0.3V LCZ METER 502B 4 Q S-F ≥25 1KHz/0.3V LCZ METER 502B 擬制/日期PREPARED BY/DATE 審核/日期CHECKED BY/DATE 黄燕铭2023/11/17 黄锦华2023/11/15

Test Setup Photos

Conducted Emission Test Setup: Radiated Emission Test Setup:

Contact Information

Applicant

Carrie Jin(Sales Manager)
[email protected]0574-86307000Fax: 0574-83607007

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from NINGBO ALLSTAR IMPORT&EXPORT CO.,LTD

WIRELESS POWER BANK - FCC ID 2A92I-AST-WR388 - NINGBO ALLSTAR IMPORT&EXPORT CO.,LTD
2A92I-AST-WR388

WIRELESS POWER BANK

Jul 07, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
WIRELESS POWER BANK - FCC ID 2A92I-AST-WR410 - NINGBO ALLSTAR IMPORT&EXPORT CO.,LTD
2A92I-AST-WR410

WIRELESS POWER BANK

Jun 16, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2A92I-AST-WR326

Phone Grip 5000 mAh MagClick Wireless Powerbank with Camera Shutter

Dec 01, 2025

Equipment Class

DTS - Digital Transmission System
2A92I-AST-WR318

IPWR 10000 MagClick Powerbank and iWatch Charger

Nov 28, 2025

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
4000 mAh MagClick Wireless Power Bank with Watch Charger - FCC ID 2A92I-AST-WR246CC - NINGBO ALLSTAR IMPORT&EXPORT CO.,LTD
2A92I-AST-WR246CC

4000 mAh MagClick Wireless Power Bank with Watch Charger

Nov 22, 2025