FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Henkel Malaysia Sdn Bhd/
  3. 2A95V-AAC-0101

2A95V-AAC-0101Smart Care Gateway

Henkel Malaysia Sdn Bhd
Smart Care Gateway - FCC ID 2A95V-AAC-0101 - Henkel Malaysia Sdn Bhd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 04, 2023
Application Purpose
Original Equipment
Date of Application
Feb 04, 2023
Equipment Note
Smart Care Gateway
Frequency Range
2412.00000000 - 2462.00000000
Company
Henkel Malaysia Sdn Bhd
Country
Malaysia

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ThisusermanualisdevelopedforthecooperationonsmartdiaperprojectwithHenkel Thisusermanualwillintroducehowtouseurinedetectorandindicator.Pleasereadbeforeusing andkeepthisusermanual. 1.Introduction UrineIndicator ItemDescription ④ResetIfindicatorisnotworkingnormally,pleasepresstheresetbutton â‘€CoolingholeCoolinghole â‘„StandStand ⑩SpeakerSpeaker ⑧PowerButtonPoweron/off,adjustbrightness,enterpairingmode,mute ⑹IndicatorWhite:standby;Green:dry.Red:Wetandneedtochange ⑩ChargeJackPleaseusemicro-USBcableforcharging 2.HowtoUse 2.1UrineIndicator 2.1.1Powerbutton Pressthebuttonfor2secondstopoweronthedevice.Thelightwillturnon. When,keeppressingfor3secondsmore,itwillenterpairingmodeforpairingurine detector. 2.1.2Lowbattery UserManualforSmartHygieneTechnologyIndicator ThisusermanualisdevelopedforthecooperationonsmartdiaperprojectwithHenkel Theinternalrechargeablebatterycanonlyworkfor3-5hours.Whenthebatteryexhausted, thedevicewillshutoffautomatically. PluginUSBcablewiththecharger.Itwillchargethebatteryautomatically.Thecable plugged-inallthetimeforinhouseuseisrecommended. 2.1.3Brightness Pressandholdthepowerbuttonwilldimthebrightnesswhilethedeviceisintheworking mode. Tobrightenthebrightnessafterdim,justpressandholdthepowerbuttonagain. 2.1.4Mute(includingwetnessalarm,andsleepposturealarm) Pressthepowerbuttononcetomute,butitwillalarmagainifithappensagain 2.1.5Colorofurineindicator Thecolorwillchangeaccordingtotheamountoftheurine. ThisusermanualisdevelopedforthecooperationonsmartdiaperprojectwithHenkel 4.ProductSpecification ItemUrineIndicator SizeR70*H70mm Weight(batteryincluded)Around80g BatteryLithiumPolymerRechargeable TransmissionBLE4.0:BluetoothLowEnergyWi-Fi Distance15meters10-20meters Frequency2.4GHz2402MHZ-2480MHZ OperatingTemperature 10ÂșC–40ÂșC10ÂșC–40ÂșC StorageTemperature 0ÂșC–50ÂșC0ÂșC–50ÂșC FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the follow ing two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, inc luding interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residentia l installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or televis ion reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technic ian for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be insta lled and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna.

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization <HenkelMalaysiaSdnBhd> Company:HenkelMalaysiaSdnBhd Address:Unit2.01,2.02,Level2,Mercu3,JalanBangsar, KLEcoCity,KualaLumpur,59200,MALAYSIA ProductName:SmartCareGateway ModelNumber:AAC-0101 FCCIdentifier:2A95V-AAC-0101 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:PoonlarpNgernmaneeratDate:2022-12-30 Title:N/A Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 <HenkelMalaysiaSdnBhd> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2022-12-30 Subject:RequestforConfidentiality FCCID:2A95V-AAC-0101 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo BlockDiagram Schematics TestReportNoNo TestSetupPhotosNo User’sManual InternalPhotos PartsList/TuneUp RFExposureInfo OperationalDescription CoverLetter(s)NoNo SDRSoftware/SecurityInfoNo Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name:PoonlarpNgernmaneerat Title:N/A

External Photos

EUTPHOTO(ExternalPhotos) ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

Labelandlabellocation SmartCareGateway FCCID:2A95V-AAC-0101

Internal Photos

EUTPHOTO(InternalPhotos) WIFI ANT BLE ANT ※※※※※ENDOFREPORT※※※※※

RF Exposure Info

FCCID:2A95V-AAC-0101 RFExposureEvaluation Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation BLEmode Mode Outputpower toantenna (dBm) Outputpowerto antenna(mW) PowerDensityat R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result GFSK1.8731.540.0004881.0PASS Remark:antennagain=2.02dBi 2.4GWIFImode Mode Outputpower toantenna (dBm) Outputpowerto antenna(mW) PowerDensityat R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 802.11b 16.21141.790.013238 1.0PASS 802.11g 16.96049.660.015730 1.0PASS 802.11n20 16.86748.610.015396 1.0PASS 802.11gn40 17.02850.440.015978 1.0PASS Remark:antennagain=2.02dBi WiFiandBLEcannottransmitinformationatthesametime

Test Report

ProjectNo.:ZKT-2212059080E Page 1 of 38 FCCTESTREPORT FCCID:2A95V-AAC-0101 ReportNumber. .................................... : ZKT-2212059080E DateofTest ....................................................... : Dec.03,2022toDec.26,2022 Dateofissue ......................................... : Dec.26,2022 Totalnumberofpages..........................39 TestResult..........................................: PASS TestingLaboratory............................: ShenzhenZKTTechnologyCo.,Ltd. Address...............................................: 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname.............................: HenkelMalaysiaSdnBhd Address ............................................... : Unit2.01,2.02,Level2,Mercu3,JalanBangsar, KLEcoCity,KualaLumpur,59200,MALAYSIA Manufacturer'sname ...................... : HenkelMalaysiaSdnBhd Address ............................................... : Unit2.01,2.02,Level2,Mercu3,JalanBangsar, KLEcoCity,KualaLumpur,59200,MALAYSIA Testspecification: Standard................................................: FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10:2013 Testprocedure.....................................: / Non-standardtestmethod ................ :N/A TestReportFormNo. ....................... : TRF-EL-111_V0 TestReportForm(s)Originator ..... : ZKTTesting MasterTRF........................................: Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname ..................................... :SmartCareGateway Trademark ........................................... :HenkelQhesiveSolutions Model/Typereference......................: AAC-0101 Ratings .................................................. : Input:DC5V ProjectNo.:ZKT-2212059080E Page 2 of 38 Testingprocedureandtestinglocation: TestingLaboratory.......................................:ShenzhenZKTTechnologyCo.,Ltd. Address............................................................:1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China TomZou Testedby(name+signature).......................: JacksonFang Reviewer(name+signature) ....................... : LakeXie Approved(name+signature) ....................... : ProjectNo.:ZKT-2212059080E Page 3 of 38 TableofContents Page 1.VERSION5 2.SUMMARYOFTESTRESULTS6 2.1TESTFACILITY7 2.2MEASUREMENTUNCERTAINTY7 3.GENERALINFORMATION8 3.1GENERALDESCRIPTIONOFEUT8 3.2DESCRIPTIONOFTESTMODES9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)9 3.5EQUIPMENTSLISTFORALLTESTITEMS10 4.EMCEMISSIONTEST12 4.1CONDUCTEDEMISSIONMEASUREMENT12 4.1.11POWERLINECONDUCTEDEMISSIONLIMITS12 4.1.2TESTPROCEDURE12 4.1.3DEVIATIONFROMTESTSTANDARD12 4.1.4TESTSETUP13 4.1.5EUTOPERATINGCONDITIONS13 4.1.6TESTRESULTS13 4.2RADIATEDEMISSIONMEASUREMENT14 4.2.1RADIATEDEMISSIONLIMITS16 4.2.2TESTPROCEDURE17 4.2.3DEVIATIONFROMTESTSTANDARD17 4.2.4TESTSETUP17 4.2.5EUTOPERATINGCONDITIONS18 5.RADIATEDBANDEMISSIONMEASUREMENT23 5.1TESTREQUIREMENT:23 5.2TESTPROCEDURE23 5.3DEVIATIONFROMTESTSTANDARD23 5.4TESTSETUP24 5.5EUTOPERATINGCONDITIONS24 5.6TESTRESULT25 6.POWERSPECTRALDENSITYTEST26 6.1APPLIEDPROCEDURES/LIMIT26 6.2TESTPROCEDURE26 6.3DEVIATIONFROMSTANDARD26 6.4TESTSETUP26 ProjectNo.:ZKT-2212059080E Page 4 of 38 TableofContentsPage 6.5EUTOPERATIONCONDITIONS26 6.6TESTRESULTS27 7.CHANNELBANDWIDTH29 7.1APPLIEDPROCEDURES/LIMIT29 7.2TESTPROCEDURE29 7.3DEVIATIONFROMSTANDARD29 7.4TESTSETUP29 7.5EUTOPERATIONCONDITIONS29 7.6TESTRESULTS30 8.PEAKOUTPUTPOWERTEST32 8.1APPLIEDPROCEDURES/LIMIT32 8.2TESTPROCEDURE32 8.3DEVIATIONFROMSTANDARD32 8.4TESTSETUP32 8.5EUTOPERATIONCONDITIONS32 8.6TESTRESULTS33 9.CONDUCTEDBANDEDGEANDSPURIOUSEMISSION34 9.1APPLICABLESTANDARD34 9.2TESTPROCEDURE34 9.3DEVIATIONFROMSTANDARD34 9.4TESTSETUP34 9.5EUTOPERATIONCONDITIONS34 10.ANTENNAREQUIREMENT37 11.TESTSETUPPHOTO38 12.EUTCONSTRUCTIONALDETAILS38 ProjectNo.:ZKT-2212059080E Page 5 of 38 1.VERSION ReportNo.VersionDescriptionApproved ZKT-2212059080ERev.01InitialissueofreportDec.26,2022 ProjectNo.:ZKT-2212059080E Page 6 of 38 2.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: FCCPart15(15.247),SubpartC Standard Section TestItemJudgmentRemark FCCpart15.203/15.247 (c) AntennarequirementPASS FCCpart15.207ACPowerLineConductedEmissionPASS FCCpart15.247(b)(3)ConductedPeakOutputPowerPASS FCCpart15.247(a)(2)ChannelBandwidth&99%OCBPASS FCCpart15.247(e)PowerSpectralDensityPASS FCCpart15.247(d)BandEdgePASS FCCpart15.205/15.209SpuriousEmissionPASS NOTE: (1)“N/A”denotestestisnotapplicableinthisTestReport ProjectNo.:ZKT-2212059080E Page 7 of 38 2.1TESTFACILITY ShenzhenZKTTechnologyCo.,Ltd. Add.:1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrialAvenue,FuhaiStreet,Bao'an District,Shenzhen,China FCCTestFirmRegistrationNumber:692225 DesignationNumber:CN1299 ICRegisteredNo.:27033 2.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U  whereexpendeduncertaintyUisbasedonastandard uncertaintymultipliedbyacoveragefactorofk=2  providingalevelofconfidenceofapproximately95 % 。 No.ItemUncertainty 1 3mcamberRadiatedspurious emission(9KHz-30MHz) U=4.5dB 2 3mcamberRadiatedspurious emission(30MHz-1GHz) U=4.8dB 3 3mchamberRadiatedspurious emission(1GHz-6GHz) U=4.9dB 4 3mchamberRadiatedspurious emission(6GHz-40GHz) U=5.0dB 5ConducteddisturbanceU=3.2dB 6RFBandEdgeU=1.68dB 7RFpowerconductedU=1.86dB 8RFconductedSpuriousEmissionU=2.2dB 9RFOccupiedBandwidthU=1.8dB 10RFPowerSpectralDensityU=1.75dB 11humidityuncertaintyU=5.3% 12Temperatureuncertainty U=0.59 °C ProjectNo.:ZKT-2212059080E Page 8 of 38 3.GENERALINFORMATION 3.1GENERALDESCRIPTIONOFEUT ProductN


Text truncated - open the document above for the full version.

Test Report

ProjectNo.:ZKT-2212059080E-2 Page 1 of 57 FCCTESTREPORT FCCID:2A95V-AAC-0101 ReportNumber...................................:ZKT-2212059080E-2 DateofTest.......................................................:Dec.03,2022toDec.28,2022 Dateofissue.........................................:Dec.28,2022 Totalnumberofpages..........................57 TestResult............................................: PASS TestingLaboratory............................: ShenzhenZKTTechnologyCo.,Ltd. Address ............................................... : 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname ............................. : HenkelMalaysiaSdnBhd Address...............................................: Unit2.01,2.02,Level2,Mercu3,JalanBangsar, KLEcoCity,KualaLumpur,59200,MALAYSIA Manufacturer'sname......................: HenkelMalaysiaSdnBhd Address...............................................: Unit2.01,2.02,Level2,Mercu3,JalanBangsar, KLEcoCity,KualaLumpur,59200,MALAYSIA Testspecification: Standard................................................: FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10:2013 Testprocedure.....................................: / Non-standardtestmethod................:N/A TestReportFormNo. ....................... : TRF-EL-110_V0 TestReportForm(s)Originator ..... : ZKTTesting MasterTRF........................................: Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname.....................................:SmartCareGateway Trademark...........................................:HenkelQhesiveSolutions Model/Typereference.........................: AAC-0101 Ratings..................................................: Input:DC5V ProjectNo.:ZKT-2212059080E-2 Page 2 of 57 Testingprocedureandtestinglocation: TestingLaboratory.......................................:ShenzhenZKTTechnologyCo.,Ltd. Address............................................................:1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China TomZou Testedby(name+signature).......................: JacksonFang Reviewer(name+signature) ....................... : LakeXie Approved(name+signature).......................: ProjectNo.:ZKT-2212059080E-2 Page 3 of 57 TableofContents Page 1.VERSION5 2.SUMMARYOFTESTRESULTS6 2.1TESTFACILITY7 2.2MEASUREMENTUNCERTAINTY7 3.GENERALINFORMATION8 3.1GENERALDESCRIPTIONOFEUT8 3.2DESCRIPTIONOFTESTMODES9 3.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED9 3.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)9 3.5EQUIPMENTSLISTFORALLTESTITEMS11 4.EMCEMISSIONTEST13 4.1CONDUCTEDEMISSIONMEASUREMENT13 4.1.1POWERLINECONDUCTEDEMISSIONLIMITS13 4.1.2TESTPROCEDURE13 4.1.3DEVIATIONFROMTESTSTANDARD13 4.1.4TESTSETUP14 4.1.5EUTOPERATINGCONDITIONS14 4.1.6TESTRESULT15 4.2RADIATEDEMISSIONMEASUREMENT17 4.2.1RADIATEDEMISSIONLIMITS17 4.2.2TESTPROCEDURE17 4.2.3DEVIATIONFROMTESTSTANDARD18 4.2.4TESTSETUP18 4.2.5EUTOPERATINGCONDITIONS19 4.2.6TESTRESULTS19 5.RADIATEDBANDEMISSIONMEASUREMENT30 5.1TESTREQUIREMENT:30 5.2TESTPROCEDURE30 5.3DEVIATIONFROMTESTSTANDARD30 5.4TESTSETUP31 5.5EUTOPERATINGCONDITIONS31 5.6TESTRESULT32 6.POWERSPECTRALDENSITYTEST34 6.1APPLIEDPROCEDURES/LIMIT34 6.2TESTPROCEDURE34 6.3DEVIATIONFROMSTANDARD34 6.4TESTSETUP34 6.5EUTOPERATIONCONDITIONS34 ProjectNo.:ZKT-2212059080E-2 Page 4 of 57 6.6TESTRESULT35 7.CHANNELBANDWIDTH&99%OCCUPYBANDWIDTH43 7.1APPLIEDPROCEDURES/LIMIT43 7.2TESTPROCEDURE43 7.3DEVIATIONFROMSTANDARD43 7.4TESTSETUP43 7.5EUTOPERATIONCONDITIONS43 7.6TESTRESULT44 8.PEAKOUTPUTPOWERTEST47 8.1APPLIEDPROCEDURES/LIMIT47 8.2TESTPROCEDURE47 8.3DEVIATIONFROMSTANDARD47 8.4TESTSETUP47 8.5EUTOPERATIONCONDITIONS47 8.6TESTRESULT48 9.CONDUCTEDBANDEDGEANDSPURIOUSEMISSION49 9.1APPLICABLESTANDARD49 9.2TESTPROCEDURE49 9.3DEVIATIONFROMSTANDARD49 9.4TESTSETUP49 9.5EUTOPERATIONCONDITIONS49 9.6TESTRESULTS49 10.ANTENNAREQUIREMENT56 11.TESTSETUPPHOTO57 12.EUTCONSTRUCTIONALDETAILS57 ProjectNo.:ZKT-2212059080E-2 Page 5 of 57 1.VERSION ReportNo.VersionDescriptionApproved ZKT-2212059080E-2Rev.01InitialissueofreportDec.28,2022 ProjectNo.:ZKT-2212059080E-2 Page 6 of 57 2.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: FCCPart15(15.247),SubpartC Standard Section TestItemResultRemark FCCpart15.203/15.247 (c) AntennarequirementPASS FCCpart15.207ACPowerLineConductedEmissionPASS FCCpart15.247(b)(3)ConductedPeakOutputPowerPASS FCCpart15.247(a)(2)ChannelBandwidth&99%OCBPASS FCCpart15.247(e)PowerSpectralDensityPASS FCCpart15.247(d)BandEdgePASS FCCpart15.205/15.209SpuriousEmissionPASS NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport ProjectNo.:ZKT-2212059080E-2 Page 7 of 57 2.1TESTFACILITY ShenzhenZKTTechnologyCo.,Ltd. Add.:1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrialAvenue,FuhaiStreet,Bao'an District,Shenzhen,China FCCTestFirmRegistrationNumber:692225 DesignationNumber:CN1299 ICRegisteredNo.:27033 CABidentifier:CN0110 2.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U  whereexpendeduncertaintyUisbasedonastandard uncertaintymultipliedbyacoveragefactorofk=2  providingalevelofconfidenceofapproximately95 % 。 No.ItemUncertainty 1ConductedEmissionTest±1.38dB 2RFpowerconducted±0.16dB 3Spuriousemissionsconducted±0.21dB 4Allemissionsradiated(<1G)±4.68dB 5Allemissionsradiated(>1G)±4.89dB 6Temperature±0.5°C 7Humidity±2% ProjectNo.:ZKT-2212059080E-2 Page 8 of 57 3.GENERALINFORMATION 3.1GENERALDESCRIPTIONOFEUT ProductName: SmartCareGateway ModelNo.: AAC-0101 ModelDifferent.: N/A SampleID ZKT-2212059080E Sample(s)Status: Engineersample Channelnumbers:802.11b/802.11g/802.11n(HT20):11 802.11n(HT40):7 Channelseparation:5MHz Modulationtec


Text truncated - open the document above for the full version.

Test Report

TangshanHongJiaTechnologyCo.,Ltd www.tshjdz.com -1- BluetoothantennaofPCBon-board specification V1.0 1、Index ItemContentPageRemark 1Index1 2Specification2 3ReturnLoss2 4RadiationPattern3 DocumentType:PCBAntenna DocumentVersion:V2.0 ReleaseDate:Jan252020 TangshanHongJiaTechnologyCo.,Ltd Telephone:86-18131562111 TangshanHongJiaTechnologyCo.,Ltd www.tshjdz.com -2- 2、Specification ProductNumber:PCBAntenna SamplePhoto: A.ElectricalCharacteristics Frequency2400~2500MHz S.W.R.<=2.0 Gain2.02dBi Efficiency~50% PolarizationLinear Impedance50Ohm B.Material&MechanicalCharacteristics MaterialofRadiatorplatedcopper C.Environmental OperationTemperature -40 °C ~+85 °C StorageTemperature-40°C~+105°C 3、ReturnLoss TangshanHongJiaTechnologyCo.,Ltd www.tshjdz.com -3- 4、RadiationPattern RadiationPatternandGainweredependentonmeasurementboarddesign.Thespecificationofcoilantennawas measuredbasedonthePCBsizeandinstallationpositionasshowninthebelowfigureTestBoard. VerticalHorizontal Y-ZPlane Average Gain=1.19dBi PeakGain=2.02dBi AverageGain=0.71dBi PeakGain=-1.37dBi AverageGain=-8.6dBi X-ZPlane Average Gain=-2.91dBi PeakGain=-3.76dBi AverageGain=-8.72dBi PeakGain=-0.25dBi AverageGain=-4.24dBi TangshanHongJiaTechnologyCo.,Ltd www.tshjdz.com -4- X-YPlane Average Gain=-0.95dBi PeakGain=0.76dBi AverageGain=-5.81dBi PeakGain=1.37dBi AverageGain=-2.67dBi

Test Report

TangshanHongJiaTechnologyCo.,Ltd www.HJSIP.com.cn -1- Wi-FiantennaofPCBon-board specification V1.0 1、Index ItemContentPageRemark 1Index1 2Specification2 3PCBANTDimensional Drawing 2 4ReturnLoss3 5RadiationPattern3 DocumentType:PCBAntenna DocumentVersion:V2.0 ReleaseDate:Jan25  2020 TangshanHongJiaTechnologyCo.,Ltd Telephone:86-18131562111 TangshanHongJiaTechnologyCo.,Ltd www.HJSIP.com.cn -2- 2、Specification ProductNumber:PCBAntenna SamplePhoto: A.ElectricalCharacteristics Frequency2400~2500MHz S.W.R.<=2.0 Gain≈ 2.02dBi Efficiency≈ 50% PolarizationLinear Impedance50Ohm AdmittedPower2W(33dBm) RadiationOmni-directional ConnectorTypePCBlineconnect B.Material&MechanicalCharacteristics MaterialofRadiatorPCBplatedcopper C.Environmental OperationTemperature-40°C~+85°C StorageTemperature-40°C~+105°C 3、PCBANTDimensionalDrawing TangshanHongJiaTechnologyCo.,Ltd www.HJSIP.com.cn -3- 4、ReturnLoss 5、RadiationPattern RadiationPatternandGainweredependentonmeasurementboarddesign.Thespecificationofcoilantennawas measuredbasedonthePCBsizeandinstallationpositionasshowninthebelowfigureTestBoard. VerticalHorizontal TangshanHongJiaTechnologyCo.,Ltd www.HJSIP.com.cn -4- Y-ZPlane Average Gain=1.19dBi PeakGain=2.02dBi AverageGain=0.71dBi PeakGain=-1.37dBi AverageGain=-8.6dBi X-ZPlane Average Gain=-2.91dBi PeakGain=-3.76dBi AverageGain=-8.72dBi PeakGain=-0.25dBi AverageGain=-4.24dBi X-YPlane Average Gain=-0.95dBi PeakGain=0.76dBi AverageGain=-5.81dBi PeakGain=1.37dBi AverageGain=-2.67dBi

Test Setup Photos

EUTTESTPHOTO ※※※※※ENDOFREPORT※※※※※

Contact Information

Applicant

Mr. Poonlarp Ngernmaneerat
[email protected]+66 81 9107309Fax: +66 81 9107309

Technical Contact

Shenzhen ZKT Technology Co., Ltd.Lake xie
[email protected]0086-400 000 9970

Shenzhen · China

Non-Technical Contact

Shenzhen ZKT Technology Co., Ltd.Lake xie
[email protected]0086-400 000 9970

Test Firm

Shenzhen ZKT Technology Co., Ltd.Lake Xie
[email protected]0086-13620010775

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz50.44 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance. The device contains 20MHz and 40MHz bandwidth.

Other Applications from Henkel Malaysia Sdn Bhd

Smart Care Sensor - FCC ID 2A95V-AAC-0101-1 - Henkel Malaysia Sdn Bhd
2A95V-AAC-0101-1

Smart Care Sensor

Feb 04, 2023

Equipment Class

DTS - Digital Transmission System