Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
88.8 mm 60.8 mm 35 mm JOYSTICK EN 60669 -1 / EN 60669 - 2-1 12.B2.8.230.0000 U N 110...230 V AC (50/60 Hz) / DC U min - U max 88 V - 253 V (AC / DC) P 2.8 VA (50 Hz) / 0.9 W 2 CO (DPDT) 16 A 250 V AC AC1 4000 VA AC15 (230 V AC) 750 VA (230 V) 2000 W (230 V) 750 W CFL-LED (230 V) 400 W (–20...+50)°C IP20 Utility Model - IB12B2VXX - 07/25 - Finder S.p.A. con unico socio - 10040 ALMESE (TO) - ITALY 12.B2 - Operating Control, Independently mounted - Panel mounting, Type 1 Action - Pollution Degree 2, Impulse Voltage 4000 V - Terminals nominal torque: 0.8 Nm - The battery can be replaced only by the manufacturer or competent personnel - The device can be installed and configured only by the installer or a qualified installer FULL MANUAL WEB FCC ID: 2A97G-12001 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance voids the user’s authority to operate this equipment. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help RF EXPOSURE This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This device should be installed and operated with a minimum distance of 20 cm between the radiator and your body.
UL International (UK) Ltd ULID-018088 issue 3 04/15/2025 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: CFR 47 §2.911 (d)(5) Attestation Applicant: Finder S.p.A. FCC ID: 2A97G-12001 Model number/name: 12B282300000 To whom it may concern 1.The applicant certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2.The applicant certifies that, the device does not have cybersecurity and / or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, identified on the Covered List installed on the device, nor will it be installed by the applicant anytime after certification. 3.The applicant certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Sincer ely yours, Name: Rocco Didio Job Title: Certifications manager con unico socio
con unico socio
con unico socio
UL International (UK) Ltd ULID-006026 issue 4 .0 04/15/2025 Telecommunication Certification Body UL International (UK) Ltd Units 1-4, Horizon Wade Road, Kingsland Business Park Basingstoke, Hampshire RG24 8AH United Kingdom Subject: Authorisation Letter Applicant: Finder S.p.A. con unico socio FCC ID: 2A97G-12001 Model number/name: 12B282300000 To whom it may concern The applicant hereby authorises UL International (UK) Ltd. to act as the TCB for the above application to the FCC. The applicant certifies that they are not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. The applicant also acknowledges that the FCC operates a certification scheme that makes some documentation (information) accessible to the public in accordance with FCC KDB publication 726920 D01. This is information that is generally known to the public. Yours faithfully, Rocco Didio, Certifications manager
07/29/2025 Telecommunication Certification Body UL International (UK) Ltd Units 1-4, Horizon Wade Road, Kingsland Business Park Basingstoke, Hampshire RG24 8AH United Kingdom Subject: Permanent Confidentiality Request Applicant: Finder S.p.A. con unico socio FCC ID: 2A97G-12001 Model number/name: 12B282300000 To whom it may concern Pursuant to Sections 0.457(d) and 0.459 of CFR 47, the applicant requests that the following information, provided to support the FCC application for the above device be held permanently confidential: Schematics Block Diagrams Operational Description The above material contains trade secrets not customarily released to public that are judged to have the potential to cause detriment to the applicant and provide unjustified benefits to its competitors. This information should not be available for public disclosure for an indefinite period of time. Yours faithfully Rocco Didio, Certifications manager
RXXX 2000 W 750 W 16A 250V IND. CONT. EQ. E526095 -20 ... +50°C 12A 110/230V AC FCC ID: 2A97G-12001 Laser Printing 12B2 series Specifica Tecnica /Technical Data UT112BMAR Emissione LO : S.Marhoum Livello di revisione nr. DATA REVISIONE CLASSIFICAZIONE DOCUMENTO PAG. NR. Approvazione UT : R.Didio Draft 15 .04 .2025Uso Interno 1/1 Copyright © 2024 Finder S.p.A. con unico socio – Documento ad uso interno. Tu tti i diritti sono riservati. Nessuna parte di questa pubblicazione può essere riprodotta o trasmessa senza il permesso di Finder S.p.A. Le informazioni sono riservate e non possono essere diffuse o comunicate a terzi senza il permesso di Finder S.p.A.
RF Exposure Analysis – Routine Evaluation Exemption Applicant: Finder S.p.A. con unico socio FCC ID: 2A97G-12001 Model number/name: 12B282300000 The above device operates in the 2402-2480 MHz frequency band (Bluetooth LE). The following FCC Rule Parts are applicable: Part 2.1093 – Radiofrequency radiation exposure evaluation: portable devices Part 1.1307(b)(3)(i)(A) - Blanket RF exposure exemption (i) Part 1.1307(b)(3)(i)(C) - MPE test exemption (ii) Part 1.1307(b)(3)(i)(B) - SAR test exemption (iii) For the above device: Transmitter frequency range = 2402-2480 MHz Maximum time-averaged Power = -5.0 dBm = 0.316 mW (including tune-up tolerance) Evaluation From Part 1.1307, RF exposure exemption applies if the maximum transmitted power is less than the maximum of the following three criteria: i) No more than 1 mw Blanket exemption. P TH = 0.001 W – §1.1307(b)(3)(i)(A) ii) determination of exemption under the MPE-based §1.1307(b)(3)(i)(C), if i) not met iii) determination of exemption under the SAR-based §1.1307(b)(3)(i)(B) if both i) and ii) are not met; Conclusion: The source-based, time-averaged power of 0.316 mW is no more than 1 mW and therefore the above device is exempt from routine evaluation in accordance with §1.1307(b)(3)(i)(A). Certification Body UL International (UK) Ltd
Test Report No. 25-4791433404-2-1-0-RAD-A Page 1 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 RF TEST REPORT Test Report No: 25-4791433404-2-1-0-RAD-A UL Project No: 4791433404 Date of issue: 2025-12-16 Total number of pages: 99 Applicant: Finder S.p.A. con unico socio Via Drubiaglio, 14 10040 Almese (TO) – Italy Contact’s person: Rocco Didio ([email protected]) Testing Laboratory: UL International Italia S.r.l. Via delle Industrie, 6 (Sede A) 20061 Carugate (MI) – Italy Testing location: UL International Italia S.r.l. Via delle Industrie, 6 20061 Carugate (MI) – Italy Test specification: Regulations: FCC/ISED Standards: FCC Parts 15.207 & 15.209(a) & 15.247 RSS-247 Issue 3:2023 RSS-Gen Issue 5:2021 Non-standard test method: N/A Scope of testing: Wireless - New testing TRF No.: TRF_Accredia_FCC/ISED-FT_rev 0 Test Report Form(s) Originator: UL International Italia S.r.l. Master TRF 2017-07 Compiled by: (name, function, signature) Andrea Giovanni Galbiati Laboratory Engineer Approved by: (name, function, signature) Francesco Casati Operations Leader General disclaimer: The test results presented in this test report relate only to the object tested, not selected by UL International Italia S.r.l.. This report shall not be reproduced, except in full, without the written approval of the issuing Testing Laboratory. This document contains data (of information) using color and if printed, should be printed in color to retain legibility and the information represented by the color. Declination of responsibility: Data provided by the customer are clearly identified with (*). UL International Italia S.r.l. cannot be considered responsible for this information, for any other document sent by the Applicant/Manufacturer and for any difference between the software version present in the tested sample and that present in the object intended for final sale. In some cases, the software in the tested sample is in a version dedicated exclusively to the test, and therefore does not represent the software installed in the final version of the product. Test Report No. 25-4791433404-2-1-0-RAD-A Page 2 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Test Item Description: Annual astro time switch with Bluetooth Trade Mark: (*) Finder Manufacturer: (*) Finder S.p.A. con unico socio Via Drubiaglio, 14 10040 Almese (TO) – Italy Model Name or Numer / HVIN: (*) 12B282300000 PMN: (*) No information available FCC ID: (*) 2A97G-12001 ISED Canada Certification number: (*) No information available Ratings: (*) IN: 110-230 V AC/DC (2.8 VA/0.9 W) OUT: 16 A, 250 Vac (2 x CO contacts) Testing: Date of receipt of test item: 2025-02-24 UL Sample Tag No.: 7479954 7479102 Status of sample upon receipt: ☒ New and operational ☐ Reconditioned ☐ Damaged Date(s) of performance of tests: 2025-02-24 to 2025-03-27 Name and address of factory(ies): (*) Finder S.p.A. con unico socio Via Drubiaglio, 14 10040 Almese (TO) – Italy General remarks: A cross ☒ in a rectangular shape means that this option is applied. ☒ Indicates that the listed condition, standard or equipment is applicable for this report. ☐ Indicates that the listed condition, standard or equipment is not applicable for this report. Throughout this report a ☐ comma / ☒ point is used as decimal separator. Where not otherwise specified or communicated in writing, statements of conformity (e.g. Pass/Fail) are established according to the following decision rule: considering that the applied test standards take measurement uncertainty into account, acceptance limit equals the tolerance limit (simple acceptance). This leads to a maximum 50% of false accept or false reject when the measured value equals the tolerance limit. See ILAC- G8:09/2019 for further details. General product information: (*) Configurable Time switch with 2 output relays. Multifunction. Test Report No. 25-4791433404-2-1-0-RAD-A Page 3 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Document history Test Report No. Reason for change Date of issue 25-4791433404-2-1-0-RAD-A Original release 2025-12-16 NOTE: New test report issue cancels and replaces the previous one. Test Report No. 25-4791433404-2-1-0-RAD-A Page 4 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Laboratory Accreditation FCC Accredited Test Firm Accreditation MRA Designation Number Expiration Date Ministero delle Sviluppo Economico- Direzione Generale Pianificazione e Gestione dello Spettro Radioelettrico Scope: Unintentional Radiators - FCC Part 15 Subpart B Industrial, Scientific, and Medical Equipment - FCC Part 18 Intentional Radiators - FCC Part 15 Subpart C US-EU IT0010 04-02-2027 ISED Wireless Device Testing Laboratory Company Number CAB Identifier Scope/Recognition Date Expiration Date UL INTERNATIONAL ITALIA S.R.L. IT0008 RSS-GEN (2023-10-06) RSS-247 (2023-10-06) RECOGNIZED UNTIL: 2027-09-30 ACCREDIA ISO/IEC 17025:2017 Expires: 2025-06-16 Test Report No. 25-4791433404-2-1-0-RAD-A Page 5 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Table of Contents Laboratory Accreditation .................................................................................................................................... 4 1 Test Item Description ................................................................................................................................. 6 1.1 Additional Information of EUT Radio Function(s) (*) ............................................................................ 8 2 Verdict summary section ..................................................................................…
Text truncated - open the document above for the full version.
Test Report No. 25-4791433404-2-1-0-RAD-A Page 60 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 ☐ The emissions are below the measurement system noise floor or 20 dB or more below the limit ☒ Final measurements for emissions that are above -20 dB from the applicable limits are shown below (at least 6 worst frequencies): Final Measurement Table Frequency Measure Peak (dBμV/m) Measure QPeak (dBμV/m) Limit QPeak (dBμV/m) Margin QPeak (dB) Max height (m) Max angle (°) Polarization RBW (Hz) Meas.Time (s) Comments Correction (dB) 49.05 MHz 23.41 13 40 -27 2.24 260.2 Horizontal 120 k 5 Pass 20.09 162.57 MHz 21.82 12.65 43.52 -30.87 1.32 233.9 Horizontal 120 k 5 Pass 20.27 487.68 MHz 26.45 17.55 46.02 -28.47 2.81 310.9 Horizontal 120 k 5 Pass 25.08 797.25 MHz 33.54 23.76 46.02 -22.26 3.63 46.6 Horizontal 120 k 5 Pass 30.63 953.82 MHz 34.43 25.31 46.02 -20.71 2.19 73.7 Horizontal 120 k 5 Pass 32.4 30.06 MHz 29.58 22.31 40 -17.69 1.05 100 Vertical 120 k 5 Pass 18.43 45.09 MHz 34.95 27.54 40 -12.46 1.05 16.5 Vertical 120 k 5 Pass 19.93 48.93 MHz 29.04 20.26 40 -19.74 1.05 19.6 Vertical 120 k 5 Pass 20.09 54.42 MHz 27.5 18.71 40 -21.29 1.05 190.9 Vertical 120 k 5 Pass 19.93 59.46 MHz 30.61 23.85 40 -16.15 1.02 256.6 Vertical 120 k 5 Pass 19.49 62.4 MHz 28.27 20.48 40 -19.52 1.07 339.1 Vertical 120 k 5 Pass 19.13 Test Report No. 25-4791433404-2-1-0-RAD-A Page 61 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Operating mode .......................... : 4 Verdict ......................................... : Pass Instrument settings ..................... : Start Frequency: 30 MHz; Stop Frequency: 1 GHz; Step: 30 kHz; Sweep Time: 20 ms/Step; RF Attenuation: Auto; RBW: 120 kHz; VBW: Auto; Preamplifier: ON; Preselector: ON Instrument settings ..................... : Start Frequency: 30 MHz; Stop Frequency: 1 GHz; Step: 30 kHz; Sweep Time: 20 ms/Step; RF Attenuation: Auto; RBW: 120 kHz; VBW: Auto; Preamplifier: ON; Preselector: ON Test Report No. 25-4791433404-2-1-0-RAD-A Page 62 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 ☐ The emissions are below the measurement system noise floor or 20 dB or more below the limit ☒ Final measurements for emissions that are above -20 dB from the applicable limits are shown below (at least 6 worst frequencies): Final Measurement Table Frequency Measure Peak (dBμV/m) Measure QPeak (dBμV/m) Limit QPeak (dBμV/m) Margin QPeak (dB) Max height (m) Max angle (°) Polarization RBW (Hz) Meas.Time (s) Comments Correction (dB) 31.26 MHz 21.83 12.66 40 -27.34 1.27 318.7 Horizontal 120 k 5 Pass 18.42 164.52 MHz 22.55 12.3 43.52 -31.22 2.15 21 Horizontal 120 k 5 Pass 20.19 469.11 MHz 26.94 17.39 46.02 -28.63 3.18 152.8 Horizontal 120 k 5 Pass 25.07 534.51 MHz 28.75 19.22 46.02 -26.8 2.21 73.6 Horizontal 120 k 5 Pass 26.24 947.13 MHz 34.94 25.25 46.02 -20.77 2.82 33.4 Horizontal 120 k 5 Pass 32.27 997.89 MHz 34.8 25.32 53.98 -28.66 2.82 284.2 Horizontal 120 k 5 Pass 32.48 30.24 MHz 30.63 23.54 40 -16.46 1.03 345.4 Vertical 120 k 5 Pass 18.43 45 MHz 34.98 26.97 40 -13.03 1.23 238 Vertical 120 k 5 Pass 19.93 49.08 MHz 29.06 19.48 40 -20.52 1.44 359.4 Vertical 120 k 5 Pass 20.09 54.24 MHz 27.2 18.58 40 -21.42 1.23 170.7 Vertical 120 k 5 Pass 19.95 59.79 MHz 29.57 22.8 40 -17.2 1.6 22.9 Vertical 120 k 5 Pass 19.46 62.43 MHz 28.53 21 40 -19 1.13 316.3 Vertical 120 k 5 Pass 19.12 Test Report No. 25-4791433404-2-1-0-RAD-A Page 63 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Operating mode .......................... : 1 Polarization ................................. : Horizontal Verdict ......................................... : Pass Instrument settings ..................... : Start Frequency: 1 GHz; Stop Frequency: 4 GHz; Step: 250 kHz; Sweep Time: 20 ms/Step; RF Attenuation: Auto; RBW: 1 MHz; VBW: Auto; Preamplifier: ON; Preselector: ON Instrument settings ..................... : Start Frequency: 4 GHz; Stop Frequency: 18 GHz; Step: 250 kHz; Sweep Time: 5 ms/Step; RF Attenuation: Auto; RBW: 1 MHz; VBW: Auto; Preamplifier: OFF; Preselector: ON ☐ The emissions are below the measurement system noise floor or 20 dB or more below the limit ☒ Final measurements for emissions that are above -20 dB from the applicable limits are shown below (at least 6 worst frequencies): Final Measurement Table Frequency Measure Peak (dBμV/m) Limit Peak (dBμV/m) Margin Peak (dB) Measure CAvg (dBμV/m) Limit Avg (dBμV/m) Margin Avg (dB) Height (m) Angle (°) Polarization RBW (Hz) Meas.Time (s) Comments Correction (dB) 3.948 GHz 52.86 74 -21.14 37.86 54 -16.14 1.67 52.7 Horizontal 1 M 5 Pass 39.43 3.995 GHz 53.09 74 -20.91 38.08 54 -15.92 1.89 40.1 Horizontal 1 M 5 Pass 39.49 4.804 GHz 40.65 74 -33.35 29.59 54 -24.41 2.18 35.4 Horizontal 1 M 5 Pass 8.82 7.206 GHz 48.6 74 -25.4 42.84 54 -11.16 1.51 34.7 Horizontal MHz 5 Pass 13.53 Test Report No. 25-4791433404-2-1-0-RAD-A Page 64 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Operating mode .......................... : 1 Polarization ................................. : Vertical Verdict ......................................... : Pass Instrument settings ..................... : Start Frequency: 1 GHz; Stop Frequency: 4 GHz; Step: 250 kHz; Sweep Time: 20 ms/Step; RF Attenuation: Auto; RBW: 1 MHz; VBW: Auto; Preamplifier: ON; Preselector: ON Instrument settings ..................... : Start Frequency: 4 GHz; Stop Frequency: 18 GHz; Step: 250 kHz; Sweep Time: 5 ms/Step; RF Attenuation: Auto; RBW: 1 MHz; VBW: Auto; Preamplifier: OFF; Preselector: ON ☐ The emissions are below the measurement system noise floor or 20 dB or more below the limit…
Text truncated - open the document above for the full version.
Test Report No. 25-4791433404-2-1-0-RAD-A Page 77 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Channel Max peak of in-band emission (dBm) Frequency of max peak at the band edge (MHz) Peak of carrier (dB) Delta (dB) Margin (dB) polarizati on Result Bottom 50.03 2400 84.58 34.55 >20 dB Horizontal Pass Bottom 50.23 2400 90.41 40.18 >20 dB Vertical Pass NOTE: 20 dB margin applied because conducted output power was measured using Peak detector. Test Report No. 25-4791433404-2-1-0-RAD-A Page 78 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Operating mode .......................... : 1 Verdict ......................................... : Pass Instrument settings ..................... : Start Frequency: 2.31 GHz; Stop Frequency: 2.39 GHz; Step: 250 kHz; Sweep Time: 500 ms/Step; RF Attenuation: Auto; RBW: 1 MHz; VBW: Auto; Preamplifier: ON; Preselector: ON Instrument settings ..................... : Start Frequency: 2.31 GHz; Stop Frequency: 2.39 GHz; Step: 250 kHz; Sweep Time: 500 ms/Step; RF Attenuation: Auto; RBW: 1 MHz; VBW: Auto; Preamplifier: ON; Preselector: ON ☒ The emissions are below the measurement system noise floor or 20 dB or more below the limit ☐ Final measurements for emissions that are above -20 dB from the applicable limits are shown below (at least 6 worst frequencies): Test Report No. 25-4791433404-2-1-0-RAD-A Page 79 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Operating mode .......................... : 4 Verdict ......................................... : Pass Instrument settings ..................... : Start Frequency: 2.4835 GHz; Stop Frequency: 2.5 GHz; Step: 250 kHz; Sweep Time: 500 ms/Step; RF Attenuation: Auto; RBW: 1 MHz; VBW: Auto; Preamplifier: ON; Preselector: ON Instrument settings ..................... : Start Frequency: 2.4835 GHz; Stop Frequency: 2.5 GHz; Step: 250 kHz; Sweep Time: 500 ms/Step; RF Attenuation: Auto; RBW: 1 MHz; VBW: Auto; Preamplifier: ON; Preselector: ON ☒ The emissions are below the measurement system noise floor or 20 dB or more below the limit ☐ Final measurements for emissions that are above -20 dB from the applicable limits are shown below (at least 6 worst frequencies): Test Report No. 25-4791433404-2-1-0-RAD-A Page 80 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 6.9 AC power-line conducted emission Tested by: Borghesi Matteo Test date: 2025-03-27 Test location (stand): Area 11: SR2 (RF emission) Ambient temperature: 23 °C Relative humidity: 45 % Atmospheric pressure: 1002 mbar Test set-up description: ☒ Table top equipment set-up (vertical conducting plane located 40 cm to the rear of the EUT; EUT raised 80 cm above the reference ground plane) ☐ Floor standing equipment set-up (placed directly on the reference ground plane) ☐ Floor standing equipment set-up (placed on insulating material up to 12 mm, above the reference ground plane) ☐ Other: FCC Reference: Part 15.207 ISED Canada Reference: RSS-Gen 8.8 Test Method Used ANSI C63.10 Section 6.2 / FCC KDB 174176 and notes below Used mains voltage/frequency: 120 V, 60 Hz 240 V, 60 Hz Supplementary information: Preliminary measurements were performed at both 50 Hz and 60 Hz supply frequencies. There was no change to the observed emissions Test Report No. 25-4791433404-2-1-0-RAD-A Page 81 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Results Operating mode .......................... : 1 Port / terminal ............................. : Mains IN Used mains voltage/frequency ... : 120 V, 60 Hz Verdict ......................................... : Pass Instrument settings ..................... : Start Frequency: 150 kHz; Stop Frequency: 30 MHz; Step: 2.25 kHz; Sweep Time: 1 s/Step; RF Attenuation: Auto; 10 dB min attenuation: ON; RBW: 9 kHz; Preamplifier: OFF; Preselector: ON Instrument settings ..................... : Start Frequency: 150 kHz; Stop Frequency: 30 MHz; Step: 2.25 kHz; Sweep Time: 1 s/Step; RF Attenuation: Auto; 10 dB min attenuation: ON; RBW: 9 kHz; Preamplifier: OFF; Preselector: ON Test Report No. 25-4791433404-2-1-0-RAD-A Page 82 of 99 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 ☐ The emissions are below the measurement system noise floor or 20 dB or more below the limit ☒ Final measurements for emissions that are above -20 dB from the applicable limits are shown below (at least 6 worst frequencies): Final Measurement Table Frequency Measure QPeak (dBμV) Limit QPeak (dBμV) Margin QPeak (dB) Measure CAvg (dBμV) Limit Avg (dBμV) Margin Avg (dB) RBW (Hz) Meas.Time (s) Comments Correction (dB) 523.5 kHz 48.62 56 -7.38 42.38 46 -3.62 9 kHz 5 Pass 10.23 525.75 kHz 49.01 56 -6.99 42.17 46 -3.83 9 kHz 5 Pass 10.23 550.5 kHz 50.58 56 -5.42 37.83 46 -8.17 9 kHz 5 Pass 10.23 577.5 kHz 50.86 56 -5.14 44.36 46 -1.64 9 kHz 5 Pass 10.23 629.25 kHz 46.69 56 -9.31 40.24 46 -5.76 9 kHz 5 Pass 10.24 1.518 MHz 48 56 -8 39.1 46 -6.9 9 kHz 5 Pass 10.25 1.52 MHz 46.87 56 -9.13 39.84 46 -6.16 9 kHz 5 Pass 10.25 1.57 MHz 50.43 56 -5.57 39.57 46 -6.43 9 kHz 5 Pass 10.25 1.572 MHz 49.36 56 -6.64 40.77 46 -5.23 9 kHz 5 Pass 10.25 1.626 MHz 48.79 56 -7.21 41.25 46 -4.75 9 kHz 5 Pass 10.25 548.25 kHz 39.06 56 -16.94 21.53 46 -24.47 9 kHz 5 Pass 10.23 577.5 kHz 39.89 56 -16.11 28.46 46 -17.54 9 kHz 5 Pass 10.23 1.518 MHz 42.01 56 -13.99 29.72 46 -16.28 9 kHz 5 Pass 10.25 1.568 MHz 44.54 56 -11.46 29.73 46 -16.27 9 kHz 5 Pass 10.25 1.572 MHz 43.2 56 -12.8 32.83 46 -13.17 9 kHz 5 Pass 10.25 1.624 MHz 43.51 56 -12.49 35.15 46 -10.85 9 kHz 5 Pass 10.25 1.626 MHz 43.32 56 -12.68 35.09 46 -10…
Text truncated - open the document above for the full version.
Test Report No. 25-4791433404-8-1-0-RAD-A Page 1 of 31 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 RF TEST REPORT Test Report No: 25-4791433404-8-1-0-RAD-A UL Project No: 4791433404 Date of issue: 2025-12-03 Total number of pages: 31 Applicant: Finder S.p.A. con unico socio Via Drubiaglio, 14 10040 Almese (TO) – Italy Contact’s person: Rocco Didio ([email protected]) Testing Laboratory: UL International Italia S.r.l. Via delle Industrie, 6 20061 Carugate (MI) – Italy Testing location: UL International Italia S.r.l. Via delle Industrie, 6 20061 Carugate (MI) – Italy Test specification: Regulations: FCC Standards: FCC 47 CFR - Part 15 Subpart C 1989 (Antenna Gain Measurement) TRF No.: Base Radiation Pattern FCC_rev 00 Test Report Form(s) Originator: UL International Italia S.r.l. Master TRF 2025-09 Tested by: (name, function, signature) Casati Francesco Operations Leader Approved by: (name, function, signature) Riva Piergiorgio Senior Engineering Associate General disclaimer: The test results presented in this test report relate only to the object tested, as received and not selected by UL. All technical records will be maintained by the Laboratory for minimum 10 years. This report shall not be reproduced, except in full, without the written approval of the issuing Testing Laboratory. This document contains data (of information) using color and if printed, should be printed in color to retain legibility and the information represented by the color. Declination of responsibility: Data provided by the customer are clearly identified with (*). UL International Italia S.r.l. cannot be considered responsible for this information, for any other document sent by the Applicant/Manufacturer and for any difference between the software version present in the tested sample and that present in the object intended for final sale. In some cases, the software in the tested sample is in a version dedicated exclusively to the test, and therefore does not represent the software installed in the final version of the product. Test Report No. 25-4791433404-8-1-0-RAD-A Page 2 of 31 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 This page has been left intentionally blank. Test Report No. 25-4791433404-8-1-0-RAD-A Page 3 of 31 UL INTERNATIONAL ITALIA S.r.l. - Via delle Industrie, 1 - 20061 Carugate (MI) – Italy - T: +39 02 92526500 - W: www.ul.com 00999 Test Item Description: Annual astro time switch with Bluetooth Trade Mark: (*) Finder Manufacturer: (*) Finder S.p.A. con unico socio Via Drubiaglio, 14 10040 Almese (TO) – Italy Model/Type reference: (*) 12B282300000 FCC ID: (*) 2A97G-12001 Ratings: (*) IN: 110-230 V AC/DC (2.8 VA/0.9 W) OUT: 16 A, 250 Vac (2 x CO contacts) Testing: Type of equipment considered in the present document: ☐ Non-radio product ☒ Combined equipment (non-radio product with radio function) ☐ Radio product ☐ Ancillary equipment Date of receipt of test item: 2025-09-11 UL Sample Tag No.: 8885603 (conducted sample) 8804389 (radiated sample) Status of sample upon receipt: ☐ New and operational ☒ Reconditioned ☐ Damaged ☐ Unknown Date(s) of performance of tests: 2025-09-11 Name and address of factory(ies): (*) Finder S.p.A. con unico socio Via Drubiaglio, 14 10040 Almese (TO) – Italy General remarks: A cross ☒ in a rectangular shape means that this option is applied. ☒ Indicates that the listed condition, standard or equipment is applicable for this report. ☐ Indicates that the listed condition, standard or equipment is not applicable for this report. Throughout this report a ☐ comma / ☒ point is used as decimal separator. Where not otherwise specified or communicated in writing, statements of conformity (e.g. Pass/Fail) are established according to the following decision rule: • considering that the applied test standards take measurement uncertainty into account, acceptance limit equals the tolerance limit (simple acceptance). This leads to a maximum 50% of false accept or false reject when the measured value equals the tolerance limit. See ILAC-G8:09/2019 for further details. General product information: (*) Configurable Time switch with 2 output relays. Multifunc…
Text truncated - open the document above for the full version.
4191 CAPITAL VIEW DR · SUWANEE, Georgia, 30024 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 300.00 µW |

8A series
Equipment Class
DTS - Digital Transmission System