FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Eques Technology Co., Limited/
  3. 2AA47-A30

2AA47-A30EQUES Smart peephole Viewer

Eques Technology Co., Limited
EQUES Smart peephole Viewer - FCC ID 2AA47-A30 - Eques Technology Co., Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 16, 2023
Application Purpose
Original Equipment
Date of Application
May 16, 2023
Equipment Note
EQUES Smart peephole Viewer
Frequency Range
2412.00000000 - 2462.00000000
Company
Eques Technology Co., Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Attestation Statements

C5266091_X24_Ed.1 1/1 Eques Technology Co., Limited “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Eques Technology Co., Limited Grantee code: 2AA47 FCC ID: 2AA47-A30 Contact Name: Jinsong Zhang Address: Room205-210,building A,No.4200 HUMIN Road,Minhang District Shanghai Telephone No: 86-21-54389062 Fax No: 86-21-54389065 Email: [email protected] [Eques Technology Co., Limited] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. [Eques Technology Co., Limited] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. Date: 2023/05/12 Applicant’s Name: Jinsong Zhang Title: Manager 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist

Attestation Statements

EquesTechnologyCo., Limited ProductSimilarityDeclaration Product name: EQUES Smart peephole Viewer Model name: EQUES-A30,EQUES-A31, EQUES-A32,EQUES-T3 FCC ID:2AA47-A30 We (Eques Technology Co., Limited) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only difference is the model name and appearance color. Signature: Name: Jinsong Zhang Title: Manager Date: 2023-05-11 Company Name: Eques Technology Co., Limited Address: Room205-210,building A,No.4200 HUMIN Road,Minhang District Shangha

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Eques Technology Co., Limited Company: Eques Technology Co., Limited Address: Room205-210,building A,No.4200 HUMIN Road,Minhang District Shanghai Product Name: EQUES Smart peephole Viewer Model Number: EQUES-A30, EQUES-A31,EQUES-A32,EQUES-T3 FCC Identifier: 2AA47-A30 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Jinsong Zhang Date: 2023.05.12 Title: Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Eques Technology Co., Limited Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2023-05.12 Subject: Request for Confidentiality FCC ID: 2AA47-A30 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Jinsong Zhang Title: Manager 2023.05.12

External Photos

Page1of3ReportNo.:FCS202304107 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202304107 Photo3 Photo4 Page3of3ReportNo.:FCS202304107 Photo5 Photo6

ID Label/Location Info

LabelandLabelLocation FCCID:2AA47-A30

Internal Photos

Page1of4ReportNo.:FCS202304107 Internalphotos Photo1 Photo2 Page2of4ReportNo.:FCS202304107 Photo3 Photo4 Page3of4ReportNo.:FCS202304107 Photo5 Photo6 FPCAntenna Page4of4ReportNo.:FCS202304107 Photo7

RF Exposure Info

Page1of2ReportNo.:FCS202301034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com FCCRFExposure EUTDescription:EQUESSmartpeepholeViewer ModelNo.:EQUES-A30 FCCID:2AA47-A30 Equipmenttype:Stationaryequipment Testproceduresaccordingtothetechnicalstandards:KDB447498D01V06andFCC2.1091. 1.Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactof humanexposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) F=frequencyinMHz Formula:Pd=(Pout*G)/(4*π*r 2 ) Where: Pd=powerdensityinmW/cm 2 , Pout=outputpowertoantennainmW; G=gainofantennainlinearscale, π=3.14; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantennaandthetotal powerinputtotheantenna,throughthecalculation,wewillknowthedistancerwheretheMPE limitisreached. 2.TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleand Page2of2ReportNo.:FCS202301034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com highestchannelindividually. 3.TestResultofRFExposureEvaluation Modulation Channel Freq. (MHz) Conduct edpower (dBm) Max tune-up power (mW) Antenna Gain (dBi) Antenna gainnumeric Evaluation result (mW/cm2) Power density Limits (mW/cm2) 802.11b 24129.979.931.511.4160.0027981 243710.0310.071.511.4160.0028381 24629.368.631.511.4160.0024321 802.11g 241210.2110.501.511.4160.0029591 24379.378.651.511.4160.0024371 24629.108.131.511.4160.0022911 802.11n 241210.9812.531.511.4160.003531 3 1 24379.989.961.511.4160.0028071 246210.1510.351.511.4160.0029171 Conclusion:themaxresult:0.003531≤1.0compliancewithFCC'sRFExposure.

Test Report

SunnywayTechnology(China)Co.,Ltd. WiFi SH19367IA67 Tel:+86-021-64842326(shanghai) +86-0755-82504258(shenzhen) Fax:+86-021-64842328 ShanghaiR&Dcenter:Room302,building65,No.421,HongCaoRoad,CaohejingDevelopmentZone,Shanghai. ShenzhenR&DCenter:Room405,4thFloor,JinkeBuilding,No.8QiongyuRoad,Nanshan SunnywayTechnology(china)ltd.CompanyAntennaSpecification 1.PROJECTPICTURES 2.TESTFIXTURE 3.MATCHINGCIRCUIT 4.S11TEST 4.0S11testmethod 4.1 S11parameter 4.2 parameterimages 4.2.1Returnloss 4.2.2V.S.W.R 5. 5.0testequipment 5.1activedata 6. Groundhandling 7.MASSPRODUCTIONANTENNASPEC 8.RadiationPattern: SunnywayTechnology(china)ltd.CompanyAntennaSpecification 1. PROJECTPICTURES projectpicturesshownbelow: PS: Toensurethattheantennashipmentquality,thefinalmobilephoneClientsvalidatedtheantenna’s performance,shouldbekeptinourcompanyforatleastayeartime,facilitatesolvingantennaamount duringabnormalsituation, 2TESTFIXTURE Purpose:Totestantennapassiveparametersasaccuratelyaspossible。 methods:thefixtureistousea50ohmcoaxialcable,oneendisconnectedtothepadafterthe antenna‘smatchingcircuit(thefrontoftheantennaswitch),andtheotherendisconnectedto theSMAconnector. SunnywayTechnology(china)ltd.CompanyAntennaSpecification 3.MATCHINGCIRCUIT Mainantenna Value N/A 0欧姆 N/A 4.S11test 4.0S11testmethodinstructions Testequipment:LNA(E5062A) Testmethod:Witha50ohmCABLE,CABLEexportfrominstrumenttestingport,Afterthecalibration withcalibrationKey,connectedtotheSMAconnector,RecordsthereturnlossandVSWRofthe relatedfrequencypoints. Testschematicdiagramisasfollows: SunnywayTechnology(china)ltd.CompanyAntennaSpecification Testschematicdiagram 4.1S11parameter FRq(MHZ) 2.42.5 Returnloss 2.031.77 4.2 MainantennaS11: SunnywayTechnology(china)ltd.CompanyAntennaSpecification 5 Testequipment Testsystem:chamber Testenvironment:thetemperatureof22°C+3°C,humidityof50%plusorminus15% Testequipment:totestpassivestatus,useLNAAgilentE5062Ctotest activestatus,use CMW500 Passiveefficiencyisasfollows: Freq EffiEffi (MHz)(%)(dB) 240048.97 -3.1 241049.03 -3.1 SunnywayTechnology(china)ltd.CompanyAntennaSpecification 242049.41 -3.06 243049.72 -3.03 2440 50.01 -3.01 245050.28 -2.99 24605122-291 247050.49-2.97 248050.43 -2.97 249049.42 -3.06 250049.04 -3.09 Directionalandapplemap 16.58 16.43 16.77 -78.59 6.Groundhandling SunnywayTechnology(china)ltd.CompanyAntennaSpecification 7.MassproductionantennaSpec DuringMassproduction ,totestVSWRasproductionteststandard Accordingtothedifferenceoftheprojectitself,thefollowingspecification: Frequence SPEC,MassProduction VSWR(MPperformance)<VSWR(Verify performance)+0.5 SunnywayTechnology(china)ltd.CompanyAntennaSpecification 8.RadiationPattern:

Test Report

FCCTestReport ReportNo: FC S202304107W0 1 Issuedfor Applicant: EquesTechnologyCo., Limited Address: Room205-210,building A,No.4200 HUMIN Road,Minhang District Shanghai ProductName: EQUESSmartpeepholeViewer BrandName: N/A ModelName: EQUES-A30 SeriesModel: EQUES-A31,EQUES-A32,EQUES-T3 FCCID: 2AA47-A30 IssuedBy: Flux ComplianceServiceLaboratory Add:Room105 FloorBao hao TechnologyBuilding1 NO.15Gongye WestRoadHi-Tech Industrial,Songshanlake Dongguan Tel: 769-27280901Fax:769-27280901http://www.FCS-lab.com Page 2 of 53ReportNo.: FCS202304107W01 Flux ComplianceServiceLaboratory Room105 FloorBao hao TechnologyBuilding1 NO.15Gongye WestRoadHi-TechIndustrial,Songshanlake Dongguan Tel: 769-27280901Fax:769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’s Name......................:EquesTechnologyCo., Limited Address......................................: Room205-210,building A,No.4200 HUMIN Road,Minhang District Shanghai Manufacture'sName................:EquesTechnologyCo., Limited Address ...................................... : Room205-210,building A,No.4200 HUMIN Road,Minhang District Shanghai ProductDescription ProductName ........................... :EQUESSmartpeepholeViewer ModelName .............................. :N/A BrandName.............................:EQUES-A30 SeriesModel..............................:EQUES-A31,EQUES-A32,EQUES-T3 Test Standards..........................:FCC Part15.247 Test Procedure..........................:ANSIC63.10-2013 This devicedescribedabovehas beentestedby Flux ComplianceServiceLaboratory, the test resultsshowthat the equipmentundertest (EUT)is in compliancewith the FCC requirements. And it is applicableonly to the testedsampleidentifiedin the report. This reportshallnot be reproducedexceptin full, withoutthe writtenapprovalof Flux Compliance ServiceLaboratory, thi s documentmaybe alteredor revisedby FluxComplianceService Laboratory, personalonly,and shall be notedin the revisionof the document.. Dateof Test..................................: Date(s) of performanceof tests . :Apr 14 , 202 3 ~ Apr 18 , 202 3 Dateof Issue ................................. :Apr 18 , 202 3 Test Result....................................:Pass Testedby: (ScottShen ) Reviewedby: (DukeQian ) Approvedby: (Jack Wang) Page 3 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY....................................................................................7 2.GENERALINFORMATION......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT.........................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS................11 2.4EQUIPMENTSLIST.........................................................................................................12 3.6DBBANDWIDTH..................................................................................................................13 3.1Limit......................................................................................................................................13 3.2TestProcedure.....................................................................................................................13 3.3Testsetup.............................................................................................................................13 3.4Testresults...........................................................................................................................14 4CONDUCTEDOUTPUTPOWER............................................................................................18 4.1limit...................................................................................................................................18 4.2testprocedure..................................................................................................................18 4.3TESTSETUP...................................................................................................................18 4.5testresults........................................................................................................................18 5.POWERSPECTRALDENSITY..............................................................................................19 5.1LIMIT................................................................................................................................19 5.2TESTPROCEDURE........................................................................................................19 5.3TESTSETUP.................................................................................................................19 5.4TESTRESULTS..............................................................................................................20 5.5originaltestdata...............................................................................................................21 6.Bandedgeandspurious(conducted).................................................................................26 6.1LIMIT................................................................................................................................26 6.2TESTPROCEDURE........................................................................................................26 6.3TESTSETUP...................................................................................................................26 6.5TESTRESUL…

Text truncated - open the document above for the full version.

Test Report

Page 41 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com (30MHz-1000MHz) Temperature:24.7°CRelativeHumidity:61% TestVoltage:DC3.8VPhase:Horizontal TestMode:802.11b(worst) No.FrequencyReadingCorrectResultLimitMarginRemark (MHz)(dBuV)Factor(dB/m)(dBuV/m)(dBuV/m)(dB) 1 98.832469.35-32.3037.0543.50-6.45 QP 2 125.886368.27-32.2736.0043.50-7.50 QP 3 197.892568.82-32.2036.6243.50-6.88 QP 4 351.708070.96-32.0538.9146.00-7.09 QP 5 451.135071.47-31.9539.5246.00-6.48 QP 6 649.659471.36-31.7039.6646.00-6.34 QP Note:1.Margin=Result(Result=Reading+Factor)–Limit 2.IfPeakResultcomplieswithQPlimit,QPResultisdeemedtocomplywithQPlimit. 3.Testsetup:RBW:120kHz,VBW:300kHz,Sweeptime:auto. Page 42 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com Temperature:22.7 °C RelativeHumidity:61% TestVoltage:DC3.8VPhase:Vertical TestMode:802.11b(worst) No.FrequencyReadingCorrectResultLimitMarginRemark (MHz)(dBuV)Factor(dB/m)(dBuV/m)(dBuV/m)(dB) 1 89.904659.55-32.2827.2743.50-16.23 QP 2 143.829169.27-32.2637.0143.50-6.49 QP 3 243.377170.52-32.1638.3646.00-7.64 QP 4 351.708071.99-32.0539.9446.00-6.06 QP 5 584.789470.79-31.7939.0046.00-7.00 QP 6 848.056170.50-31.4539.0546.00-6.95 QP Note:1.Margin=Result(Result=Reading+Factor)–Limit 2.IfPeakResultcomplieswithQPlimit,QPResultisdeemedtocomplywithQPlimit. 3.Testsetup:RBW:120kHz,VBW:300kHz,Sweeptime:auto. Page 43 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com (1GHz~25GHz)RestrictedbandandSpuriousemissionRequirements 802.11b(Worst)-Low Page 44 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11b(Worst)-Middle Page 45 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11b(Worst)-High 1.Notes : emissionsareattenuated20dBbelowthelimits,soitdoesnotrecord. Remark: 1.Factor=AntennaFactor+CableLoss–Pre-amplifier. 2.Scanwith802.11b,802.11g,802.11n(HT-20),theworstcase is802.11b.EmissionLevel=Reading+FactorMargin=Limit-EmissionLeve 3.Thefrequencyemissionofpeakpointsthatdidnotshowabovetheformsareatleast20dBbelowthelimit,the frequencyemissionismainlyfromtheenvironmentnoise Page 46 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11blowCH 802.11bHighCH Page 47 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11gLowCH 802.11gHighCH Page 48 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 802.11N20LowCH 802.11N20HighCH Page 49 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 8CONDUCTEDEMISSIONTEST 8.1.1POWERLINECONDUCTEDEMISSIONLIMITS Operatingfrequencyband.IncasetheemissionfallwithintherestrictedbandspecifiedonPart 207(a)limitinthetablebelowhastobefollowed. FREQUENCY(MHz) ConductedEmissionlimit(dBuV) Quasi-peakAverage 0.15-0.566-56*56-46* 0.50-5.056.0046.00 5.0-30.060.0050.00 Note: (1)Thetighterlimitappliesatthebandedges. (2)Thelimitof"*"markedbandmeansthelimitationdecreaseslinearlywiththe logarithmofthefrequencyintherange. Thefollowingtableisthesettingofthereceiver ReceiverParametersSetting Attenuation10dB StartFrequency0.15MHz StopFrequency30MHz IFBandwidth9kHz Page 50 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 8.1.2TESTPROCEDURE a. TheEUTwas0.8metersfromthehorizontalgroundplaneand0.4metersfromthevertical groundplanewithEUTbeingconnectedtothepowermainsthroughalineimpedance stabilizationnetwork(LISN).AllothersupportequipmentspoweredfromadditionalLISN(s). TheLISNprovide50Ohm/50uHofcouplingimpedanceforthemeasuringinstrument. b. Interconnectingcablesthathangcloserthan40cmtothegroundplaneshallbefoldedback andforthinthecenterformingabundle30to40cmlong. c. I/Ocablesthatarenotconnectedtoaperipheralshallbebundledinthecenter.Theendofthe cablemaybeterminated,ifrequired,usingthecorrectterminatingimpedance.Theoverall lengthshallnotexceed1m. d. LISNatleast80cmfromnearestpartofEUTchassis. e. Fortheactualtestconfiguration,pleaserefertotherelatedItem–EUTTestPhotos. 8.1.3TESTSETUP Note: 1.Support units were connected to second LISN. 2.Both of LISNs (AMN) are 80 cm from EUT and at least 80 cm from other units and other metal planes support. units. Vertical Reference Ground Plane 40cm 80cm Test Receiver Horizontal Reference Ground Plane EUT LISN Page 51 of53ReportNo.:FCS202304107W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.FCS-lab.com 8.1.4TESTRESULT Temperature:22.1°CRelativeHumidity:56% TestVoltage:DC5Vbyadapter Phase:L TestMode:802.11b(worst) No.FrequencyReadingC…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of2ReportNo.:FCS202304107 Blow1GHzforradiatedemissiontestsetup Above1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202304107 Conductedemissiontestsetup

Contact Information

Applicant

Jinsong Zhang(manager)
[email protected]+86-21-54389062Fax: +86-21-54389065

Technical Contact

Flux Compliance Service LaboratoryAndy yue
[email protected]86-769-27280901

Dongguan · China

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz12.53 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Eques Technology Co., Limited

EQUES Smart peephole Viewer - FCC ID 2AA47-S31 - Eques Technology Co., Limited
2AA47-S31

EQUES Smart peephole Viewer

May 16, 2023

Equipment Class

DTS - Digital Transmission System
Smart Camera - FCC ID 2AA47-R20 - Eques Technology Co., Limited
2AA47-R20

Smart Camera

Nov 15, 2014

Equipment Class

DTS - Digital Transmission System
Smart Camera - FCC ID 2AA47-C01 - Eques Technology Co., Limited
2AA47-C01

Smart Camera

Nov 18, 2013

Equipment Class

DTS - Digital Transmission System