Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Eaton ® LifeSense ® Wireless System Quick Setup Guide 2EATON LifeSense Wireless System Quick Setup Guide E-HOOV-II002-E August 2014 LifeSense Wireless System Quick Setup Guide Each LifeSense kit contains: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user is cautioned these devices are intentional radiators and changes or modifications not expressly approved by the party responsible for compliance will void the user’s authority to operate the equipment. Per RSS-Gen, Section 7.1.3, This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Suivant la section 7.1.3 du RSS-Gen, Cet appareil est conforme avec la norme RSS d'Industrie Canada exempt de licence. Son fonctionnement est soumis aux deux conditions suivantes: (1) ce dispositif ne doit pas causer d'interférences, et (2) cet appareil doit accepter toutes les interférences, y compris celles pouvant causer un mauvais fonctionnement de l'appareil. • LifeSense hose assembly (1-100) o Sensor assembly (one per hose assembly) - FCC ID 2AABYS01; IC: 12063A-S01 o Protective sleeve (one per hose assembly) • Wireless gateway/hose diagnostic unit (1) - FCC ID 2AABYG01; IC: 12063A-G01 o Power cord (1) o Programming cable (1–sold separately) o WIFI antenna (1) o Sensor antenna (1) o Sensor Key Fob (2) Table of Contents Part Listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 - 4 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Hose Assembly Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Wireless Gateway (HDU) Configuration/ Configuring a New Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 - 12 Configuring Ethernet Connection . . . . . . . . . . . . . . . . . . . . . . . .13 - 15 Configuring WIFI Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 - 18 Associating a Sensor with the Wireless Gateway (HDU) . . . . . . . . . . 19 Sensor Status and Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 LifeSense Setup Information Form . . . . . . . . . . . . . . . . . . . . . . . . . .21 - 22 IMPORTANT: Before you begin the installation of your LifeSense system read through the safety instructions in this guide. For more detailed instructions on installing your system please refer to the complete LifeSense Assembly, Installation and Service Manual (E-HOOV-TI001-E2) available on Eaton's literature library (http://hydliterature.eaton.com/ literature/). Hard copies of the catalog are available through Workflow One (WFO), using the Customer Connect portal, Distributor Resources, Literature. If you are unable to access the literature ordering site please contact WFO by calling 800-625-9100 or e-mailing [email protected] and WFO will walk you through the process. 3EATON LifeSense Wireless System Quick Setup Guide E-HOOV-II002-E August 2014 Part Listing 8 10 11 11 12 7 9 1 2 3 3 4 5 Sensor Type 2 (-16) Sensor Type 1 (-08 and -12) 2 4 6 GATEWAY CONNECTOR POWER CORD POWER CONNECTOR SETUP CABLE PC CONNECTOR CABLE 1 CABLE 2 13 4EATON LifeSense Wireless System Quick Setup Guide E-HOOV-II002-E August 2014 Item No.Qty. Req'd.DescriptionPart NumberMaterial 16NutFF91117C-33-01Stainless Steel 21Upper Shell Assembly, -08 SizeFF92117SU-08-01*Black Nylon 6-6 1Upper Shell Assembly, -12 SizeFF92117SU-12-01*Black Nylon 6-6 1Upper Shell Assembly, -16 SizeFF92117SU-16-01*Black Nylon 6-6 32Gasket, -08 SizeFF92117C-36*Black Santoprene 111-45 2Gasket, -12 SizeFF92117C-70*Black Santoprene 111-45 41Shell- Lower Half, -08 SizeFF92117C-48*Black Nylon 6-6 1Shell- Lower Half, -12 SizeFF92117C-57*Black Nylon 6-6 1Shell- Lower Half, -16 SizeFF92117C-63-01*Black Nylon 6-6/Overmold Gasket 56Panhead Machine Screw, -08 & -12 SizeFF91117C-68-01Stainless Steel 66Thread Rolling Screw, -16 SizeFF91117C-71-01Stainless Steel 71Heat-Shrink Tubing For -08FF91117PS-08-01Polyolefin 1Heat-Shrink Tubing For -12FF91117PS-12-01Polyolefin 1Heat-Shrink Tubing For -16FF91117PS-16-01Polyolefin 81Wireless Gateway/HDU AssemblyFF92117-01-- 91Power CableFF92117C-140-02-- 101Window Mount Sensor Antenna, 433Mhz FF92117C-151-02*-- 112Key FobFF92117KF-01-- 121Window Mount Antenna, WIFI FF92117C-152-02*-- 131Programming/Configuration CableFF92117C-140-01-- *Part not sold separately. Part Listing 5EATON LifeSense Wireless System Quick Setup Guide E-HOOV-II002-E August 2014 Safety Instructions The Eaton LifeSense system utilizes unique hose and fittings (U.S. Patent No. 7,555,936 and 8,183,872). Only the specified LifeSense hose and fittings can be used in this system. DO NOT use other Eaton hose and hose fittings (e.g., Aeroquip, Weatherhead, or SEL), or hose and hose fittings supplied by another manufacturer with this system. Eaton hereby disclaims any obligation or liability (including incidental and consequential damages) arising from breach of contract, warranty, or tort (under negligence of strict liability theories) should other Eaton hose and hose fittings, or hose and hose fittings supplied by another manufacturer be used interchangeably with this system, or in the event that production, assembly, or installation instructions for each specified component of Eaton LifeSense are not followed. WARNING Failure to follow process and product instructions and limitations could lead to premature hose assembly fai…
Text truncated - open the document above for the full version.
WTD 13.4.9 FCC Compliance Opinion SPCD0020 Information about the Applicant Grantee (Company Name) Eaton Aeroquip FCC Contact Person Benjamin Hoxie Address 1225 West Main Street City, State, Zip Van Wert, OH 43537 Job Number SPCD0020 Model FF92117SP-08, FF92117SP-12, FF92117SP-16 FCC ID 2AABYS01 Agent Approval Type Original Equipment Class DSR Remote Control/Security Device Transmitter Rule Part 15.231 Overview The Wireless Hose Sensor family of products, models FF92117SP-08, FF92117SP-12, and FF92117SP-16, are heavy industrial hydraulic hose sensors used to send status messages to a Wireless Hose Gateway. Confidentiality requested for allowed files. Request is properly addressed and referenced. Recommendation All items have been resolved and completed to my satisfaction; therefore I recommend this application for approval. Signature Dave Tolman, TCB Committee 10/14/2014
External Photos: LED Indicator Sensor Contacts FF92117SP-08 Installed on a size 8
External Photos: Indication LED Sensor Contacts
Eaton Aeroquip LLC 1225 West Main Street Van Wert, Ohio 45891, U.S.A. Grantee Code No. 2AABY Page 1 of 3 ______________________________________________________________________________________________________________________________ Subject: LABEL & LOCATION (FCC ID) FCC ID- 2AABYS01 Laser Engraved into Sensor Cover Model – FF92117SP-08 Model –FF92117SP-12 Eaton Aeroquip LLC 1225 West Main Street Van Wert, Ohio 45891, U.S.A. Grantee Code No. 2AABY Page 2 of 3 ______________________________________________________________________________________________________________________________ Subject: LABEL & LOCATION (FCC ID) Model –FF92117SP-16 Ultrasonically welded to the top of the Hose Sensor Eaton Aeroquip LLC 1225 West Main Street Van Wert, Ohio 45891, U.S.A. Grantee Code No. 2AABY Page 3 of 3 ______________________________________________________________________________________________________________________________ Subject: LABEL & LOCATION (FCC ID) Installed on a Hydraulic Hose
Internal Photos: Assembly inside the Enclosure: Top Enclosure: LED Pipe Antenna soldered to Sensor PCB 3.6V Battery 3.6 Volt Sensor battery: Sensor Antenna Antenna connections that are soldered to the Sensor header Foam Spacer PCB Sensor PCB Battery Connector Antenna Connectors Sensor Contact Connections Indication LED Transceiver Section Tracking number
Eaton Hydraulics, Inc. 7945 Wallace Road Eden Prairie, MN 55344 Page 1 of 4 ___________________________________________________________________________________________________________________________________ Subject: Wireless Sensor antenna Info ___________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________________________________________________ Notice to persons receiving this drawing and/or technical information. EATON Corporation claims proprietary rights in the information disclosed hereon. This document is issued in confidence and is not to be reproduced or used to manufacture anything shown hereon without the written permission of the EATON Corporation. Antenna Schematic Fab Drawing Eaton Hydraulics, Inc. 7945 Wallace Road Eden Prairie, MN 55344 Page 2 of 4 ___________________________________________________________________________________________________________________________________ Subject: Wireless Sensor antenna Info ___________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________________________________________________ Notice to persons receiving this drawing and/or technical information. EATON Corporation claims proprietary rights in the information disclosed hereon. This document is issued in confidence and is not to be reproduced or used to manufacture anything shown hereon without the written permission of the EATON Corporation. Antenna Assembly: Eaton Hydraulics, Inc. 7945 Wallace Road Eden Prairie, MN 55344 Page 3 of 4 ___________________________________________________________________________________________________________________________________ Subject: Wireless Sensor antenna Info ___________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________________________________________________ Notice to persons receiving this drawing and/or technical information. EATON Corporation claims proprietary rights in the information disclosed hereon. This document is issued in confidence and is not to be reproduced or used to manufacture anything shown hereon without the written permission of the EATON Corporation. Sensor Assembly and Antenna Mount: Eaton Hydraulics, Inc. 7945 Wallace Road Eden Prairie, MN 55344 Page 4 of 4 ___________________________________________________________________________________________________________________________________ Subject: Wireless Sensor antenna Info ___________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________________________________________________ Notice to persons receiving this drawing and/or technical information. EATON Corporation claims proprietary rights in the information disclosed hereon. This document is issued in confidence and is not to be reproduced or used to manufacture anything shown hereon without the written permission of the EATON Corporation. Antenna Installed in Sensor The effective gain of the assembled antenna is -6.23dBi
Spectrum Design Solutions LifeSense Hose Sensor FCC 15.231:2013 / FCC.231:2014 Report #: SPCD0020 Report Prepared By Northwest EMC Inc. NORTHWEST EMC – (888) 364-2378 – www.nwemc.com California – Minnesota – Oregon – New York – Washington WTD 12.5.23 CERTIFICATE OF TEST Last Date of Test: September 8, 2014 Spectrum Design Solutions Model: LifeSense Hose Sensor Emissions Test Description Specification Test Method Pass/Fail Duty Cycle FCC 15.231:2013 ANSI C63.10:2009 Pass Occupied Bandwidth FCC 15.231:2013 ANSI C63.10:2009 Pass Field Strength of Fundamental FCC 15.231:2014 ANSI C63.10:2009 Pass Spurious Radiated Emissions FCC 15.231:2014 ANSI C63.10:2009 Pass Deviations From Test Standards None Approved By: Tim O'Shea, Operations Manager NVLAP Lab Code: 200881-0 This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. Product compliance is the responsibility of the client, therefore the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. This Report may only be duplicated in its entirety. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. REV 2012.08.02 REVISION HISTORY Revision Number Description Date Page Number 00 None Barometric Pressure The recorded barometric pressure has been normalized to sea level. REV 2012.05.24 ACCREDITATIONS AND AUTHORIZATIONS United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC Guide 65 as a product certifier. This allows Northwest EMC to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada IC - Recognized by Industry Canada as a Certification Body (CB). Certification chambers and Open Area Test Sites are filed with IC. European Union European Commission – Validated by the European Commission as a Conformity Assessment Body (CAB) under the EMC directive and as a Notified Body under the R&TTE Directive. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea KCC / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Hong Kong OFTA – Recognized by OFTA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. Russia GOST – Accredited by Certinform VNIINMASH, CERTINFO, SAMTES, and Federal CHEC to perform EMC and Hygienic testing for Information Technology products to GOST standards. SCOPE For details on the Scopes of our Accreditations, please visit: http://www.nwemc.com/accreditations/ REV 2013.03.8 MEASUREMENT UNCERTAINTY Measurement Uncertainty When a measurement is made, the result will be different from the true or theoretically correct value. The difference is the result of tolerances in the measurement system that cannot be completely eliminated. To the extent that technology allows us, it has been our aim to minimize this error. Measurement uncertainty is a statistical expression of measurement error qualified by a probability distribution. A measurement uncertainty estimation has been performed for each test per our internal quality document WP 342. The estimation is used to compare the measured result with its "true" or theoretically correct value. The expanded measurement uncertainty (K=2) for each test is listed below. Our measurement data meets or exceeds the measurement uncertainty requirements of the applicable specification; therefore, the test data can be compared directly to the specification limit to determine compliance. The calculations for estimating measurement uncertainty are based upon ETSI TR 100 028 (or CISPR 16-4-1 as applicable), and are available upon request. The following table represents the Measurement Uncertainty (MU) budgets for each of the tests that may be contained in this report. Test + MU - MU Frequency Accuracy (Hz) 0.12 -0.01 Amplitude Accuracy (dB) 0.49 -0.49 Conducted Power (dB) 0.41 -0.41 Radiated Power via Substitution (dB) 0.69 -0.68 Temperature (degrees C) 0.81 -0.81 Humidity (% RH) 2.89 -2.89 Field Strength (dB) 3.80 -3.80 AC Powerline Conducted Emissions (dB) 2.94 -2.94 REV 2013.06.28 FACILITIES Oregon Labs EV01-12 22975 NW Evergreen Pkwy Hillsboro, OR 97124 (503) 844-4066 California Labs OC01-13 41 Tesla Irvine, CA 92618 (949) 861-8918 New York Labs NY01-04 4939 Jordan Rd. Elbridge, NY 13060 (315) 685-0796 Minnesota Labs MN01-08 9349 W Broadway Ave. Brooklyn Park, MN 55445 (763) 425-2281 Washington Labs NC01-05,SU02,SU07 19201 120 th Ave. NE Bothell, WA 98011 (425) 984-6600 VCCI A-0108 A-0029 A-0109 A-0110 Industry Canada 2834D-1, 2834D-2 2834B-1, 2834B-2, 2834B-3 2834E-1 2834C-1 NVLAP NVLAP Lab Code: 200630-0 NVLAP Lab Code: 200676-0 NVLAP Lab Code: 200761-0 NVLAP Lab Code: 200881-0 NVLAP Lab Code: 200629-0 WTD 12.5.23 PRODUCT DESCRIPTION Client and Equipment Under Test (EUT) Information Company Name: Eaton Corporation Address: 7945 Wallace Road City, State, Zip: Eden Prairie, MN 55344 Test Requested By: John Capesius Model: LifeSense Hose Sensor First Date of Test: October 31, 2013 Last Date of Test: September 8, 2014 Receipt Date of Samples: October 31, 2013 Equipment Design Stage: Production Equipment Condition: No Damage Information Provided by the Party Requesting the Test Functional Description of the EUT (Equipment…
Text truncated - open the document above for the full version.
Duty Cycle XMit 2013.08.15 NORTHWEST Duty Cycle EMC DC 001.JPG Duty Cycle Report No. SPCD00201/9 Occupied Bandwidth XMit 2013.08.15 NORTHWEST Occupied Bandwidth EMC DC 001.JPG Occupied Bandwidth Report No. SPCD00202/9 photo FF 001.jpg FF 002.jpg Field Strength of Fundamental PSA-ESCI 2012.12.14 Report No. SPCD00203/9 photo FF 003.jpg FF 004.jpg Field Strength of Fundamental PSA-ESCI 2012.12.14 Report No. SPCD00204/9 photo FF 001.jpg FF 002.jpg Spurious Radiated Emissions PSA-ESCI 2012.12.14 Report No. SPCD00205/9 photo FF 003.jpg FF 004.jpg Spurious Radiated Emissions PSA-ESCI 2012.12.14 Report No. SPCD00206/9 WTD.2013.06.13, PSA-ESCI 2012.12.14, EmiR5 2013.08.26 VERIFICATION OF DIGITAL DEVICE <1GHz Report No. SPCD00207/9 photo FF 001.jpg FF 002.jpg VERIFICATION OF DIGITAL DEVICE >1GHz PSA-ESCI 2012.12.14 Report No. SPCD00208/9 photo FF 003.jpg FF 004.jpg VERIFICATION OF DIGITAL DEVICE >1GHz PSA-ESCI 2012.12.14 Report No. SPCD00209/9
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

FF92117-01
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver