STANMORE BLUETOOTH - ACTIVE STEREO LOUDSPEAKER QUICK START GUIDE 009. 010. 003. 012. 011. 013. 014. 015. 013.015. 016. 005. 017. 018. 017. 018. STANMORE BLUETOOTH 019. 020. 021.021. 007. 022. 023. 023.
This device complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. The device should be installed and operated with a minimum distance of 20cm between the radiator and your body. This device must not be collocated or operating in conjunction with any other antenna or transmitter.
Full user manual available at: WWW.MARSHALLHEADPHONES.COM
ReferenceNo.:151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong523942,China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email:[email protected] Page1of3ReportVersion1 PHOTOGRAPHS OF THE EUT ReferenceNo.:151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong523942,China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email:[email protected] Page2of3ReportVersion1 ReferenceNo.:151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong523942,China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email:[email protected] Page3of3ReportVersion1
Label location βThe label Screen print to the equipment by permanent adhesiveβ
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version 1 Reference No.: 151112N078 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version 1 Reference No.: 151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Reference No.: 151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Reference No.: 151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Reference No.: 151112N078 ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 6 of 6 Report Version 1 Reference No.: 151112N078
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version 1 Test Report No.: FS151112N078 RF EXPOSURE REPORT Applicant Zound Industries International AB Address Centralplan 15 SE-111 20 Stockholm Sweden Manufacturer or Supplier DONGGUAN TYMPHANY ACOUSTIC TECHNOLOGY CO., LTD Address Tymphany Building, Liuwu Section, Ke-ji Dong Road, Shijie Town, Dongguan City, Guangdong, China 523290 Product Active Loud Speaker Brand Name Model STANMORE Additional Model & Model Difference N/A Date of tests Nov. 12, 2015 ~ Nov. 26, 2015 FCC Part 2 (Section 2.1091) KDB 447498 D01 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Blue Zheng Project Engineer / EMC Department Approved by Chris Chen Assistant Manager / EMC Department Date: Nov. 27, 2015 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version 1 Test Report No.: FS151112N078 Table of Contents RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE LIMIT ..................................................................................... 5 3. MPE CALCULATION FORMULA ..................................................................... 5 4. CLASSIFICATION ........................................................................................... 5 5. ANTENNA GAIN .............................................................................................. 6 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ................... 6 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Test Report No.: FS151112N078 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FS151112N078 Original release Nov. 27, 2015 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Test Report No.: FS151112N078 1. CERTIFICATION FCC ID: 2AAGF-STANMOREBT PRODUCT: Active Loud Speaker BRAND NAME: MODEL NO.: STANMORE ADDITIONAL NO.: N/A TEST SAMPLE: Engineering Sample APPLICANT: Zound Industries International AB STANDARDS: FCC Part 2 (Section 2.1091) KDB 447498 D01 IEEE C95.1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Test Report No.: FS151112N078 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 6 of 6 Report Version 1 Test Report No.: FS151112N078 5. ANTENNA GAIN The antennas provided to the EUT, please refer to the following table: Transmitter Circuit Peak Gain (dBi) Antenna Type Chain 0 2.7 Integral PCB Antenna 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER FREQUENCY BAND (MHz) MAX POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 2412-2462 8.531 2.7 20 0.00394 1.0 --- END ---
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 53 Report Version 1 Test Report No.: RF151112N078-1 TEST REPORT Applicant Zound Industries International AB Address Centralplan 15 SE-111 20 Stockholm Sweden Manufacturer or Supplier DONGGUAN TYMPHANY ACOUSTIC TECHNOLOGY CO., LTD Address Tymphany Building, Liuwu Section, Ke-ji Dong Road, Shijie Town, Dongguan City, Guangdong, China 523290 Product Active Loud Speaker Brand Name Model STANMORE Additional Model & Model Difference N/A Date of tests Nov. 12, 2015 ~ Nov. 26, 2015 the tests have been carried out according to the requirements of the following standards: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Blue Zheng Project Engineer / EMC Department Approved by Chris Chen Assistant Manager / EMC Department Date: Nov. 27, 2015 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 53 Report Version 1 Test Report No.: RF151112N078-1 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 5 1 SUMMARY OF TEST RESULTS ...................................................................................................... 6 2 MEASUREMENT UNCERTAINTY .................................................................................................. 6 3 GENERAL INFORMATION.............................................................................................................. 7 3.1 GENERAL DESCRIPTION OF EUT ........................................................................................... 7 3.2 DESCRIPTION OF TEST MODES ............................................................................................. 7 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 9 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................... 9 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS .......................................................... 11 3.4 DESCRIPTION OF SUPPORT UNITS ..................................................................................... 11 4 TEST TYPES AND RESULTS ....................................................................................................... 12 4.1. CONDUCTED EMISSION MEASUREMENT ........................................................................... 12 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................... 12 4.1.2 TEST INSTRUMENTS ..................................................................................................... 12 4.1.3 TEST PROCEDURES ..................................................................................................... 13 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 13 4.1.5 TEST SETUP ................................................................................................................... 14 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 14 4.1.7 TEST RESULTS............................................................................................................... 15 4.2. RADIATED EMISSION AND BANDEDGE MEASUREMENT .................................................. 17 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ...................... 17 4.2.2 TEST INSTRUMENTS .................................................................................................... 18 4.2.3 TEST PROCEDURES ..................................................................................................... 19 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 20 4.2.5 TEST SETUP .................................................................................................................. 20 4.2.6 EUT OPERATING CONDITIONS ................................................................................... 20 4.2.7 TEST RESULTS .............................................................................................................. 21 4.3. NUMBER OF HOPPING FREQUENCY USED .................................................................β¦
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 37 Report Version 1 Test Report No.: RF151112N078-2 TEST REPORT Applicant Zound Industries International AB Address Centralplan 15 SE-111 20 Stockholm Sweden Manufacturer or Supplier DONGGUAN TYMPHANY ACOUSTIC TECHNOLOGY CO., LTD Address Tymphany Building, Liuwu Section, Ke-ji Dong Road, Shijie Town, Dongguan City, Guangdong, China 523290 Product Active Loud Speaker Brand Name Model STANMORE Additional Model & Model Difference N/A Date of tests Nov. 12, 2015 ~ Nov. 26, 2015 the tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Blue Zheng Project Engineer/ EMC Department Approved by Chris Chen Assistant Manager/ EMC Department Date: Nov. 27, 2015 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 37 Report Version 1 Test Report No.: RF151112N078-2 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY ................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................ 6 3.1 GENERAL DESCRIPTION OF EUT ............................................................................................. 6 3.2 DESCRIPTION OF TEST MODES ............................................................................................... 7 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ............................................................. 7 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .................................. 7 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 10 3.4 DESCRIPTION OF SUPPORT UNITS ....................................................................................... 10 4 TEST TYPES AND RESULTS .......................................................................................................11 4.1 CONDUCTED EMISSION MEASUREMENT .............................................................................. 11 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT .............................................. 11 4.1.2 TEST INSTRUMENTS .................................................................................................... 11 4.1.3 TEST PROCEDURES ................................................................................................... 12 4.1.4 DEVIATION FROM TEST STANDARD.......................................................................... 12 4.1.5 TEST SETUP ................................................................................................................. 13 4.1.6 EUT OPERATING CONDITIONS .................................................................................. 13 4.1.7 TEST RESULTS ............................................................................................................. 14 4.2 RADIATED EMISSION MEASUREMENT .................................................................................. 16 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT ................................................... 16 4.2.2 TEST INSTRUMENTS ................................................................................................... 17 4.2.3 TEST PROCEDURES ................................................................................................... 18 4.2.4 DEVIATION FROM TEST STANDARD.......................................................................... 18 4.2.5 TEST SETUP ................................................................................................................. 19 4.2.6 EUT OPERATING CONDITIONS .................................................................................. 19 4.2.7 TEST RESULTS ............................................................................................................. 20 4.3 6DB BANDWIDTH MEASUREMENT ............................................................β¦
Text truncated - open the document above for the full version.
Reference No.: 151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong523942,China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email:[email protected] Page1of5ReportVersion1 SET-UP FOR CONDUCTED EMISSION TEST Reference No.: 151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong523942,China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email:[email protected] Page2of5ReportVersion1 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz~1GHz > Reference No.: 151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong523942,China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email:[email protected] Page3of5ReportVersion1 Reference No.: 151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong523942,China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email:[email protected] Page4of5ReportVersion1 Frequency Range< Above 1GHz > Reference No.: 151112N078 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong523942,China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email:[email protected] Page5of5ReportVersion1
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 3.61 mW |

True Wireless Headphones
Equipment Class
DTS - Digital Transmission System
Audio Transmitter
Equipment Class
DTS - Digital Transmission System
PORTABLE STEREO LOUDSPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
PORTABLE LOUDSPEAKER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
HEADPHONES
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter