Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
BATTERY POWERED PA PA40BAT / PA40BATBT Congratulations on the purchase of your Kustom Battery Powered PA. Kustom PA40BAT and PA40BATBT Models draw on decades of amp design and manufacturing experience at Kustom. These products were built from the ground up to offer world-class tone, useful features and reliable performance. Inside this manual, you’ll find valuable information about your product’s controls and specifications. Being familiar with its features will help you effectively use your system. We wish you many years of enjoyment with your Kustom Battery Powered PA. IMPORTANT SAFETY INSTRUCTIONS Danger Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time. The U.S. Government's Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level exposures: DURATION PER DAY (HOURS) 8 6 4 3 2 1 SOUND LEVEL (dB) 90 93 95 97 100 103 According to OSHA, any exposure in the above permissible limits could result in some hearing loss. Earplugs or protectors in the ear canal or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss. If exposure in excess of the limits as put forth above, to insure against potentially harmful exposure to high sound pressure levels, it is recommended that all persons exposed to equipment capable of inducing high sound pressure levels, such as this amplification system, be protected by hearing protectors while this unit is in operation. THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF NON-INSULATED "DANGEROUS VOLTAGE" WITHIN THE PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS. THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE UNIT. APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS. 1. Read all safety and operating instructions before using this product. 2. All safety and operating instructions should be kept for future reference. 3. Read and understand all warnings listed on the operating instructions. 4. Follow all operating instructions to operate this product. 5. This product should not be used near water, i.e. Bathtub, sink, swimming pool, wet basement, etc. 6. Only use dry cloth to clean this product. 7. Do not block any ventilation openings, It should not be placed flat against a wall or placed in a built-in enclosure that will impede the flow of cooling air. 8. Do not install this product near any heat sources; such as, radiators, heat registers, stove or other apparatus (including heat producing amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety if the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord being walked on or pinched, particularly at Plugs, convenience receptacles and the point where they exit from the apparatus. Do not break the ground pin of the power supply cord. 11. Only use attachments specified by the manufacturer. 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer or sold with the apparatus. When a cart is used, use caution when moving cart/apparatus combination to avoid injury from tip-over. 13. Unplug this apparatus during lightning storms or when unused for long periods of time. 14. Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation ports or any other openings. 15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way; such as, power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped. 16. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 17. When the MAINS plug, or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable. 18. Protective Ground Terminal: The apparatus shall be connected to an AC main socket with a protective earth ground connection. Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan Apparatet må tilkoples jordet stikkontakt Apparaten skall anslutas till jordat uttag Battery Warning: Do not expose to extreme temperatures Keep out of direct sunlight Keep away from Open Flames IMPORTANT SAFETY INSTRUCTIONS FRENCH Danger L‘exposition a des niveaux eleves de bruit peut provoquer une perte permanente de l’audition, Chaque organisme humain reagit differemment quant a la perte de l’audition, mais quasiment tout le monde subit une diminution de I’acuite auditive lors d’une exposition suffisamment longue au bruit intense. Les autorites competentes en reglementation de bruit ont defini les expositions tolerees aux niveaux de bruits: DURATION PER DAY (HOURS) 8 6 4 3 2 1 SOUND LEVEL (dB) 90 93 95 97 100 103 Selon les autorites, toute exposition dans les limites citees ci- dessus,peuvent provoquer certaines pertes d’audition. Des bouchons ou protections dans l’appareil auditif ou sur l’oreille doivent etre portes lors de l’utilisation de ce systeme d’amplification afin de prevenir le risque de perte permanente de l’audition, Dans le cas d’expositions superieures aux limites precitees il est recommande, afin de se premunir contre les …
Text truncated - open the document above for the full version.
BATTERY POWERED PA PW40BAT / PW40BATBT Congratulations on the purchase of your Powerwerks Battery Powered PA. Powerwerks PW40BAT and PW40BATBT Models draw on decades of amp design and manufacturing experience at Powerwerks. These products were built from the ground up to offer world-class tone, useful features and reliable performance. Inside this manual, you’ll find valuable information about your product’s controls and specifications. Being familiar with its features will help you effectively use your system. We wish you many years of enjoyment with your Powerwerks Battery Powered PA. IMPORTANT SAFETY INSTRUCTIONS Danger Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time. The U.S. Government's Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level exposures: DURATION PER DAY (HOURS) 8 6 4 3 2 1 SOUND LEVEL (dB) 90 93 95 97 100 103 According to OSHA, any exposure in the above permissible limits could result in some hearing loss. Earplugs or protectors in the ear canal or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss. If exposure in excess of the limits as put forth above, to insure against potentially harmful exposure to high sound pressure levels, it is recommended that all persons exposed to equipment capable of inducing high sound pressure levels, such as this amplification system, be protected by hearing protectors while this unit is in operation. THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF NON-INSULATED "DANGEROUS VOLTAGE" WITHIN THE PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS. THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE UNIT. APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS. 1. Read all safety and operating instructions before using this product. 2. All safety and operating instructions should be kept for future reference. 3. Read and understand all warnings listed on the operating instructions. 4. Follow all operating instructions to operate this product. 5. This product should not be used near water, i.e. Bathtub, sink, swimming pool, wet basement, etc. 6. Only use dry cloth to clean this product. 7. Do not block any ventilation openings, It should not be placed flat against a wall or placed in a built-in enclosure that will impede the flow of cooling air. 8. Do not install this product near any heat sources; such as, radiators, heat registers, stove or other apparatus (including heat producing amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety if the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord being walked on or pinched, particularly at Plugs, convenience receptacles and the point where they exit from the apparatus. Do not break the ground pin of the power supply cord. 11. Only use attachments specified by the manufacturer. 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer or sold with the apparatus. When a cart is used, use caution when moving cart/apparatus combination to avoid injury from tip-over. 13. Unplug this apparatus during lightning storms or when unused for long periods of time. 14. Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation ports or any other openings. 15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way; such as, power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped. 16. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 17. When the MAINS plug, or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable. 18. Protective Ground Terminal: The apparatus shall be connected to an AC main socket with a protective earth ground connection. Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan Apparatet må tilkoples jordet stikkontakt Apparaten skall anslutas till jordat uttag Battery Warning: Do not expose to extreme temperatures Keep out of direct sunlight Keep away from Open Flames IMPORTANT SAFETY INSTRUCTIONS FRENCH Danger L‘exposition a des niveaux eleves de bruit peut provoquer une perte permanente de l’audition, Chaque organisme humain reagit differemment quant a la perte de l’audition, mais quasiment tout le monde subit une diminution de I’acuite auditive lors d’une exposition suffisamment longue au bruit intense. Les autorites competentes en reglementation de bruit ont defini les expositions tolerees aux niveaux de bruits: DURATION PER DAY (HOURS) 8 6 4 3 2 1 SOUND LEVEL (dB) 90 93 95 97 100 103 Selon les autorites, toute exposition dans les limites citees ci- dessus,peuvent provoquer certaines pertes d’audition. Des bouchons ou protections dans l’appareil auditif ou sur l’oreille doivent etre portes lors de l’utilisation de ce systeme d’amplification afin de prevenir le risque de perte permanente de l’audition, Dans le cas d’expositions superieures aux limites precitees il est recommande, afin de se prem…
Text truncated - open the document above for the full version.
Kustom Musical Amplification INC. 3015 Kustom Drive , Hebron, KY 41048,USA Tel : 001-859- 817-7164 Fax. : 001-859- 817-7199 022311 – 6 Authority to Act as Agent Date: February 10, 2014 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: ______Intertek Test Services Shanghai_____ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b) , to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: ____ October 10, 2014____ By: __________________________ Fred (Signature 1 ) (Print name) Title: Engineering On behalf of: Kustom Musical Amplification INC. (Company Name) Telephone: +01 859-817-7164 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
Kustom Musical Amplification INC. 3015 Kustom Drive , Hebron, KY 41048,USA Tel : 001-859- 817-7164 Fax. : 001-859- 817-7199 022311 – 6 Request for Confidentiality Date: __ February 10, 2014_ Subject: Confidentiality Request for: _____FCC ID: 2AAVGHMG1406A & IC: 11349A-HMG1406A_____ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 2 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary)______ ____ Kustom Musical Amplification INC.____ has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180 ) 3 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By: ________________________ Fred (Signature/Title 4 ) (Print name) 2 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.” 3 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 4 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
FCC ID: 2AAVGHMG1406A IC: 11349A-HMG1406A Page 1 of 3 External Picture FCC ID: 2AAVGHMG1406A IC: 11349A-HMG1406A Page 2 of 3 EUT FCC ID: 2AAVGHMG1406A IC: 11349A-HMG1406A Page 3 of 3
ཐॿ ᴤ᭩অਧ ᮠ䟿 ᐕ㢪ॆ߶ḷ ᢩ߶ ᴤ᭩ḷ䇠 ᰕᵏ ㆮ ᅮᕐ ᄬ㓗ḷ䇠 ޡᕐ 䍘䟿 മࡦ ᧿മ ᑵ䶒 ∄ֻ ᓅമᙫਧ Ṭᔿ˄ǂ˅ ᰕᵏ ㆮ ᰗᓅമᙫਧ ޏ೬ྑௐġ cჼ଼ჼϢԄૅௗĢ cਐүϢӖဟPPϢၭ༘ڇ್Ģ cٝྼၕ5߸PPĢ cଈറζੋྑ࢈ၫcํၶᄩĢ cჾੋഔēഔઝఘখؘԨᆐําӶĢcรᅟ٤Е̟ᄓd ϫॸե͐ +0.1mm PW40BATBT ੋ͐܊ ઝෳζੋଈ۱റӬಾᅫժੋރีࣄઝϢၭ༘ଈറ ᶝᐎḟᯟ亯丣૽ᴹ䲀ޜਨ ޙಁ ಌۢ եැ ܈էนPP ᅫᅘ ࠄۏ ᆙغ PPٞഔಇէPP ჾੋ +1-0
FCC ID: 2AAVGHMG1406A IC: 11349A-HMG1406A Page 1 of 1 Statement of compliance to SAR Equipment : Power Amplifier Type/Model : PW40BATBT, PA40BATBT Applicant : Kustom Musical Amplification INC. 3015 Kustom Drive, Hebron, Kentucky, 41048 USA According to KDB 447498, if [the max output power / min test separation distance]* [f(GHz)] ≤ 3.0, it can follow the test exclusion procedure. As we can see from the test report 131200985SHA-001: The maximum P = 0.08dBm G = 0dBi EIRP = PG = 0.08dBm = 1.019mW The test exclusion limit = [1.019/5]*[2.5] = 0.13 ≤ 3.0 It is found the EIRP of EUT is lower than the test exclusion limit. Therefore, the EUT complies the requirement of 15.247(I) without test. Date of issue: March 06, 2014 Prepared by: Reviewed by: Nemo Li (Project Engineer) Daniel Zhao (Reviewer)
FCC ID: 2AAVGHMG1406A IC: 11349A-HMG1406A Page 1 of 53 EMC TEST REPORT for Intentional Radiator No. 131200985SHA-001 Applicant : Kustom Musical Amplification INC. 3015 Kustom Drive, Hebron, Kentucky, 41048 USA Manufacturer : Hangzhou Samko Electronics Co., Ltd. No. 8, Jiaqi Road, Xianlin Street, Yuhang District, Hangzhou, 311122 China Equipment : Power Amplifier Type/Model : PW40BATBT, PA40BATBT SUMMARY The equipment complies with the requirements according to the following standard(s): 47CFR Part 15 (2013): Radio Frequency Devices ANSI C63.4 (2003): American National Standard for Methods of Measurement of Radio- Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz RSS-210 Issue 8 (December 2010): Low-power Licence-exempt Radiocommunication Devices (All Frequency Bands): Category I Equipment RSS-Gen Issue 3 (December 2010): General Requirements and Information for the Certification of Radiocommunication Equipment Date of issue: March 14, 2014 Prepared by: Reviewed by: Nemo Li (Project Engineer) Daniel Zhao (Reviewer) FCC ID: 2AAVGHMG1406A IC: 11349A-HMG1406A Page 2 of 53 Description of Test Facility Name: Intertek Testing Services Ltd. Shanghai Address: Building No.86, 1198 Qinzhou Road(North), Shanghai 200233, P.R. China FCC Registration Number: 236597 IC Assigned Code: 2042B-1 Name of contact: Steve Li Tel: +86 21 64956565 ext. 214 Fax: +86 21 54262335 ext. 214 FCC ID: 2AAVGHMG1406A IC: 11349A-HMG1406A Page 3 of 53 Content SUMMARY .......................................................................................................................................................... 1 DESCRIPTION OF TEST FACILITY ......................................................................................................................... 2 1. GENERAL INFORMATION ............................................................................................................................ 5 1.1 Applicant Information ..................................................................................................... 5 1.2 Identification of the EUT ................................................................................................ 5 1.3 Technical specification ................................................................................................... 6 1.4 Mode of operation during the test / Test peripherals used .............................................. 6 2. TEST SPECIFICATION .................................................................................................................................. 7 2.1 Instrument list ................................................................................................................. 7 2.2 Test Standard .................................................................................................................. 7 2.3 Test Summary ................................................................................................................. 8 3. 20 DB BANDWIDTH ...................................................................................................................................... 9 3.1 Limit ................................................................................................................................ 9 3.2 Test Configuration .......................................................................................................... 9 3.3 Test Procedure and test setup .......................................................................................... 9 3.4 Test Protocol ................................................................................................................. 10 4. CARRIER FREQUENCY SEPARATION ........................................................................................................ 14 4.1 Limit .............................................................................................................................. 14 4.2 Test Configuration ........................................................................................................ 14 4.3 Test Procedure and test setup ........................................................................................ 14 4.4 Test Protocol ................................................................................................................. 15 5. MAXIMUM PEAK OUTPUT POWER ............................................................................................................. 19 5.1 Test limit ....................................................................................................................... 19 5.2 Test Configuration ........................................................................................................ 19 5.3 Test procedure and test setup ........................................................................................ 19 5.4 Test protocol ................................................................................................................. 20 6. RADIATED SPURIOUS EMISSIONS.............................................................................................................. 24 6.1 Test limit ....................................................................................................................... 24 6.2 Test Configuration ........................................................................................................ 24 6.3 Test procedure and test setup ........................................................................................ 25 6.4 Test protocol ................................................................................................................. 26 7. CONDUCTED SPURIOUS EMISSIONS & BAND EDGE ................................................................................. 30 7.1 Limit .............................................................................................................................. 3…
Text truncated - open the document above for the full version.
FCC ID: 2AAVGHMG1406A IC: 11349A-HMG1406A Page 1 of 2 Test Setup FCC ID: 2AAVGHMG1406A IC: 11349A-HMG1406A Page 2 of 2 30-1000MHz Above 1GHz
Building No.86, 1198 Qinzhou Road(North) · Shanghai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |

Power Amplifier
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
DAWN50BT, PW50BT
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter