FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Carewell Electric Technology (Zhongshan) Co., Ltd./
  3. 2AAZPFAN61T4S

2AAZPFAN61T4SREMOTE CONTROL

Carewell Electric Technology (Zhongshan) Co., Ltd.
REMOTE CONTROL - FCC ID 2AAZPFAN61T4S - Carewell Electric Technology (Zhongshan) Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 16, 2015
Application Purpose
Original Equipment
Date of Application
Jul 16, 2015
Equipment Note
REMOTE CONTROL
Frequency Range
315.00000000 - 315.00000000
Company
Carewell Electric Technology (Zhongshan) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Remote controller GENERAL INFORMATION This remote controller is designed to separately control your ceiling fan speed and light brightness. There are four buttons (HI, MED, LOW, OFF) to control the speed of the fan and off. The light dimmer button will control the light brightness dimmer and off. The blue indicator on the transmitter will light when one of the six buttons is pressed. INSTRUCTION OF INSTALLATION AND OPERATION 2.INSTALLING RECEIVER IN CEILING FAN A. Safety precautions: WARNING: HIGH VOLTAGE! Disconnect power by removing fuse or switching off circuit breaker. Do not use with solid state fans. Electrical wire must meet all local and national electrical code requirements. Supply for fan must be 110/120 volt, 60Hz. Maximum fan motor amps: 1.0, Maximum light watts: 190 incandescent or ballast. Otherwise power can cause serious injury or death. B. Installing receiver in fan: a. Remove power from the circuit. b. Remove ceiling fan canopy from the mounting bracket. c. Disconnect existing wiring between ceiling fan and Supply in electrical junction box. d. Make connections as follows, using the wire nuts supplied: Use wire connecting nuts supplied with the fan (FIG.3) FROM POWER SOURCE AC 110~120 VOLT 60Hz 3.5AMPS. CONNECT TO Green fan wire ....Bare supply wire Red or Black receiver wire(AC IN L) ....Black supply wire White receiver wire(AC IN N) ....White supply wire White receiver wire(TO MOTOR N) ....White fan wire Black receiver wire(TO MOTOR L) ....Black fan wire Blue receiver wire(FOR LIGHT) ....Blue light wire CAUTION: Ceiling Angle Shall Not Exceed 30 Degrees, For Mounting Controller, Model AC8.3.T ACN ACL ANT COM FAN LIGHT TRANSMITTER INPUT OUTPUT RECEIVER WHITE A C L A C N INPUT OUTPUT RED BLUE ANT CANOPY BLUE B L A C K WHITE WHITE B L A C K Use wire connecting nuts supplied with the remote controller. WIRE NUT R E C E I V E R RECEIVER CANOPY (FIG.4) ANTENNA PUT AT OUTSIDE OF CANOPY BOX CAN GET MORE OPERATION DISTANCE LIGHT MUST BE KEPT AT THE ON POSITION FAN MUST BE KEPT AT THE HIGH SPEED 1.SETTING THE CODES This unit has 16 different code combinations. To set the codes, perform the following steps: A. Setting the codes on the transmitter: a. Remove battery cover. Press firmly on the arrow and slide battery cover off. b. Slide code switches to your choice of up or down position. (Factory setting is all up. Do not use this position. Use a Small screwdriver or ball point pen to slide firmly up or down (Figure 1)). B. Setting the codes on the receiver: The Learn Key must be pressed with in 30 seconds, after pressing the Power button. If not, please press the Power button to restart. Keep pressing the button learn key in excess of 3 second it becomes a LEARN status. The receiver can remember the last codes status .The light flash two times. LEARN LIGHT ON/OFF If other fans or supply wires are different color, have this unit installed by qualified licensed electrician. e. Push all connected wires up into junction box. f. Lay the brown antenna wire on top of the receiver, and put the receiver into the mounting bracket. g. Reinstall the canopy on the mounting bracket. h. Restore power. 3. OPERATING TRANSMITTER: A. Install 12 volt battery(not included). (To prevent damage to transmitter, remove the battery if not used for a long time). B. Store the transmitter away from excessive heat or humidity. C. This remote control unit is equipped with 16 code combinations. In order to prevent possible interference from or to other remote units such as garage door openers, car alarm or security system. If you find that your fan and light kit go on and off without using your remote control, simply change the code combination in your transmitter and receiver. D. Operating the buttons on the panel of the transmitter. key -for fan speed 1,2,3,4. key-for fan speed 4,3,2,1. REV key-for fan rev. OFF key-for fan off. LIGHT/DIMMER key-for light brightness and off. LIGHT/DELAY key-for light after 3 minutes delay off. The light function is controlled by pressing the LIGHT/DIMMER key down to increase or decrease light. Tap key quickly to turn light off or on. Keep pressing the button in excess of 0.7 second and it becomes a dimmer, the light varies cyclically in 0.8 second. The receiver can remember the last status of the light brightness when the light was switched, so that it can resume to adjust the light brightness. YOUR REMOTE NOW HAS FULL CONTROL OF THE FAN AND LIGHT. OPERATION DISTANCE 20 FEET TRANSMITTER Optional Wall Mounting for Transmitter Holder Place in accessible area of your home, and screw the transmitter holder into wall using the two screws provided, slide hand unit into holder. 4. TROUBLE SHOOTING GUIDE 1. Fails to operate a. Power to receiver ? b. Receiver wired correctly ? c. Fan manual speed control in highest position ? d. Light kit switch turned on ? e. Good battery in the transmitter ? f. Code set at exact same positions in both transmitter and receiver ? 2. Won't operate at distance If transmitter operates fan/light kit when up close, but not at 20 feet away. Try placing the brown antenna wire higher, up through ceiling/outside the junction box. NOTICE ! Your ceiling fan and light kit assembly must meet the following requirements: 1. Do not use with solid state fans. 2. Electrical rating: 120v 60Hz 3.5A MAX. Motor amps: 1.0 MAX. Light watts: 190-(incandescent or ballast) WARNING TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH A WALL CONTROL/SWITCH. NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT. MODEL: FAN61T-4S LR03 1.5V AAA LR03 1.5V AAA FCC Statement: 1.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference. (2)This device must accept any interference received, including interference that may cause undes…

Text truncated - open the document above for the full version.

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 5.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (obsolete) 2.0 3.0 Jan-31-2012 Updated letter information (obsolete) 3.0 4.0 May-23-2014 Added FCC ID field (current) 4.0 5.0 Sept 16 2014 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 5.0 Carewell Electric Technology (Zhongshan) Co., Ltd. 2015-07-13 To: SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Product Certification Representative Authorization Letter We, Carewell Electric Technology (Zhongshan) Co., Ltd. hereby authorize SIEMIC, Inc. to act as a Certification Body for certifying for the following project(s): Product Description: REMOTE CONTROL Model name: FAN61T-4S FCC ID: 2AAZPFAN61T4S Sincerely, Client’s signature : Allen XU Client’s name / title:Manager Contact information / address :+86-760-88582800 (Torch Development Zone, No.2, Ouya Road, Zhongshan, Guangdong,China )

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 4.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (current) 3.0 4.0 March-26-2015 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 4.0 Carewell Electric Technology (Zhongshan) Co., Ltd. 2015-07-13 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2AAZPFAN61T4S We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature : Allen XU Client’s name / title:Manager Contact information / address :+86-760-88582800 (Torch Development Zone, No.2, Ouya Road, Zhongshan, Guangdong,China )

Internal Photos

Antenna

Test Report

Report No.: ATE20151430 Page 1 of 28 FCC ID: 2AAZPFAN61T4S ACCURATE TECHNOLOGY CO., LTD APPLICATION CERTIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: FAN61T-4S FCC ID: 2AAZPFAN61T4S Prepared for : Carewell Electric Technology (Zhongshan) Co., Ltd. Address : Torch Development Zone, No.2, Ouya Road, Zhongshan, Guangdong, China Prepared by : ACCURATE TECHNOLOGY CO., LTD Address : F1, Bldg. A, Changyuan New Material Port, Keyuan Rd. Science & Industry Park, Nanshan, Shenzhen, Guangdong P.R. China Tel: (0755) 26503290 Fax: (0755) 26503396 Report Number : ATE20151430 Date of Test : Jul 01-08,2015 Date of Report : Jul 09,2015 Report No.: ATE20151430 Page 2 of 28 FCC ID: 2AAZPFAN61T4S ACCURATE TECHNOLOGY CO., LTD TABLE OF CONTENTS Description Page Test Report Certification 1. GENERAL INFORMATION .......................................................................................................... 4 1.1. Description of Device (EUT)....................................................................................................................4 1.2. Description of Test Facility ......................................................................................................................5 1.3. Measurement Uncertainty.........................................................................................................................5 2. MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 6 3. SUMMARY OF TEST RESULTS................................................................................................... 7 4. THE FIELD STRENGTH OF RADIATION EMISSION ............................................................ 8 4.1. Block Diagram of Test Setup....................................................................................................................8 4.2. The Field Strength of Radiation Emission Measurement Limits..............................................................9 4.3. Configuration of EUT on Measurement ...................................................................................................9 4.4. Operating Condition of EUT ....................................................................................................................9 4.5. Test Procedure ........................................................................................................................................10 4.6. The Field Strength of Radiation Emission Measurement Results ..........................................................11 5. 20DB OCCUPIED BANDWIDTH ................................................................................................ 13 5.1. Block Diagram of Test Setup..................................................................................................................13 5.2. The Bandwidth of Emission Limit According To FCC Part 15 Section 15.231(c) ................................13 5.3. EUT Configuration on Measurement .....................................................................................................14 5.4. Operating Condition of EUT ..................................................................................................................14 5.5. Test Procedure ........................................................................................................................................14 5.6. Measurement Result ...............................................................................................................................14 6. RELEASE TIME MEASUREMENT............................................................................................ 15 6.1. Block Diagram of Test Setup..................................................................................................................15 6.2. Release Time Measurement According To FCC Part 15 Section 15.231(a) ..........................................15 6.3. EUT Configuration on Measurement .....................................................................................................16 6.4. Operating Condition of EUT ..................................................................................................................16 6.5. Test Procedure ........................................................................................................................................16 6.6. Measurement Result ...............................................................................................................................16 7. AVERAGE FACTOR MEASUREMENT .................................................................................... 17 7.1. Block Diagram of Test Setup..................................................................................................................17 7.2. Average factor Measurement according to ANSI C63.10-2013.............................................................17 7.3. EUT Configuration on Measurement .....................................................................................................18 7.4. Operating Condition of EUT ..................................................................................................................18 7.5. Test Procedure ........................................................................................................................................18 7.6. Measurement Result ...............................................................................................................................18 8. ANTENNA REQUIREMENT........................................................................................................ 19 8.1. The Requirement ....................................................................................................................................19 8.2. Antenna Construction ....................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

ALLEN XU(Manager)
[email protected]+86-760-88582800Fax: +86-760-85215432

Test Firm

Accurate Technology Co., Ltd.Sean Liu
[email protected]86-755-26503291Fax: 86-755-26503396

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231315 MHz - 315 MHz-
Confidentiality
Long Term

Other Applications from Carewell Electric Technology (Zhongshan) Co., Ltd.

2AAZPCT0311YB

DC power ceiling fan remote control

Jan 20, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
REMOTE CONTROL - FCC ID 2AAZPHD3T - Carewell Electric Technology (Zhongshan) Co., Ltd.
2AAZPHD3T

REMOTE CONTROL

Apr 27, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
REMOTE CONTROL - FCC ID 2AAZPDC7 - Carewell Electric Technology (Zhongshan) Co., Ltd.
2AAZPDC7

REMOTE CONTROL

Nov 10, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
REMOTE CONTROL - FCC ID 2AAZPFAN55T - Carewell Electric Technology (Zhongshan) Co., Ltd.
2AAZPFAN55T

REMOTE CONTROL

Jan 27, 2016

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
REMOTE CONTROL - FCC ID 2AAZPFAN61T4SP - Carewell Electric Technology (Zhongshan) Co., Ltd.
2AAZPFAN61T4SP

REMOTE CONTROL

Sep 27, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter