GPSRealtimetracker SOScommunicator Important.pleaseread Thistrackerwasdesignedforpeople securityandpositioning,thecompany assumenoliabilityorresponsibilityforany behaviorsviolateotherindividual’sprivacy. AllGPShavesomepositionerror,the referencepositionsindicatedbythisproduct areforyoureferenceonly,mayalsohave errors. Theremaybedelayscausedbytelecom carrieratcertaincircumstance.Ourcompany isexemptionfromliabilitytosecurityofperson andproperty. MainFunction GSMquad-bandnetwork,GPSlocation TrackingviaInternet/iphoneapp/Android app/wechat/SMS ClickforSOS Clickforcall 2waycommunication Hand-freefortalk Quietcare Lowbatteryalert ChangeSIMalert Accessories: 1*host 1*charger 1*USBcable 1*usermanual Productspecification GSMnetwork:850/900/1800/1900MHz GPRSstandard:Class12,TCP/IP GPSlocatingtime: 30secwithcoldboot(opensky) 29secwithwarmboot(opensky) 5secwithhotboot(opensky) GPSPositioningaccuracy:10-15m Workingptemerature:-20°C~+70°C Workinghumidity:5%~95%RH Hostsize:40x34x14mm Hostweight:27g ProductView ItemFunctionItemFunction 1Reboothole2Powerkey 3USBchargerhole4Key1 5GSMlight6SOSkey 7GPSlight8Key2 9SIMCardslot10microphone 11speaker12Hangropehole Photosareforreferenceonly,pleaseinkindprevail. Prepareforwork PleasechooseGSMnetwork-basedMicro-SIM cardfortheproduct.Andpleasenote: a.Pleasebesurethetrackeristurnoffbefore insertortakeouttheMicro-SIM. b.PleasebesuretheGPRSandCalleridhas beenactivated Poweron/off PleaseinserttheMicro-SIMcardintothecardslot asdirected. PressthePOWERkeyfor3sec,thenthetracker willringandlighton. Indicatorlightshow CloreBlueYellow functionGPSstatusGSMstatus SlowflashSearchingGPSSearchingGSM FastflashGPSlocatedGSMready Dark GPSsleeppingor notlocated GSMsleepingor noGSMsignal Platformtracking Pleasevisitwww.gps123.org,usetheIDnumber logintheplatform,passwordis123456,youcan trackingthetrackerandplaybackhistory. pleaseaskyouragenttogettheplatformuser accountformorefunctionasgeo-fence,system setting,etc.. FunctionsettingviaSMS Allcommanduseinlowercaselettersandending by#. Forsafetyreason,therearepasswordforsetting masternumber.Thefactorypasswordis123456. Commandforsettingmasternumber: password,sos1,phonenumber# Forexample:123456,sos1,18028758770# Thetrackerwillreply:18028758770hasbeensetfor themasternumbersuccessfully. Switchlanguage,settingbymasternumber Sendlag,1#changethelanguageto Chinese.(default) Sendlag,2#changethelanguagetoEnglish. Sendlag,3#changethelanguagetoFrench SetSOSnumber: CommandforsettingSOSnumberbymaster number: sos2,number,sos3,number,sos4,number,sos5,n umber# Forexample: sos2,13600000000,sos3,1370000000,sos4,138000 0000,sos5,1390000000#. Trackerreply:Emergencycontactnumber2,3,4,5 hasbeensetsuccessfully. CommandforsettingSOSnumberbyothernumber. sos2(3/4/5),number# Forexample:sos2,13600000000# Trackerreply:Emergencycontactnumber2has beensetsuccessfully. CommandforemptymasterandSOSnumberby master:reset#,thetrackerreplay:Thedevicewill beresettofactorydefault. MakecallandSOShelp Clickkey1willcallmasternumber. Clickkey2willcallSOS2number. PressKeySfor5secwillmakesoshelpcall.Then alloftheSOSnumberwillreceiveSMSas:SOS! Linktomycurrentlocation:http://......andthe trackerwillcallallSOSnumber2timesinturn. Answerincomingcall: push-to-talk Pressanykeyanswerincomingcallwhenthe trackerisringing. Presspowerkeytorefuseincomingcall. auto-answer(hands-free):sendcommandmt#by master,thenthetrackerwillauto-answerincoming callwithallSOSnumber,thecallercanlistenand talkwithtrackerowner. silentmonitoring:sendcommandjy#bymaster, thenthetrackerwillauto-answerincomingandkeep speakersilentwithallSOSnumber,thecallercan listenthesoundaroundthetracker. Checkfunction Checktheposition Commandbymasternumber:dw# Trackerreplythecurrentposition. Checktrackersettingandsituation: senddsp#bymaster, trackerwillreply:IDI:6401010011,GSMsignal: strong;GPSsignal:valid;Batterylife:80%; Operatingmode:push-to-talk;tracking:ON. Otherfunction Settingintervalofthepositiondataupload Commandbymaster:tim,digital# Foxexample:tim,20# Thatmeansthetrackerper20minutesuploading onetimepositiondata.(factorydefaultis10minutes) Turnon/turnoffdataupload Commandforturnondatauploadbymaster:gon# (factorydefault) Commandforturnoffdatauploadby master:goff#,inthisstate,itwillreturnmaplink whencheckpositionbydw#. Turnon/turnoffindicatorlight Cammandforturnonindicatorlightby master:lon#(factorydefault) Cammandforturnoffindicatorlightbymaster:loff# Changepassword Commandforchangepassword: password,t,newpassword# Forexample:123456,t,456789# Thetrackerreply:Yourpasswordhasbeen successfullychangedto456789.Pleasekeepit confidential. SettingAPNdata Thetrackerhavepre-programedallmostAPN,if needaddAPNintothetracker,commandforAPN settingbymaster: apn,<apn>,user<user>,pd,<password>,plmn,<pl mn># Forexample:apn,cmnet# Replyinformationforsuccessfulsetting:OK. Alertfunction Lowbatteryalert:Whenthebatteryislowthan 10%,thetrackerwillsendSMS:Lessthan10%of batteryisleft.Pleasechargethedevice immediately. ChangeSIMalert:whentheSIMwaschangedthe trackerwillsendSMS:Alert:SIMcardhasbeen changed. Remark Thetrackerwillbootautomaticallywhenitwas charging. Pleaseputthetrackerinnetworksignalbetter positionwhenuse. Thenewmachinesneedtoberechargedfor3-4 hoursbeforeuseinordertoachievethebest results,pleaseuseourdistributechargeravoid damagetothehost. Standbytime: 1)50hourswithper10minuploaddata onetime. 2)350hourswithneveruploaddata. (dependingonthelocalnetworksignal) Thanks! CommandforSMSsetting CommandFunction password,t,pa ssword Changethepassword,factorydefaultis 123456. password,sos1 ,number# Setmasternumber sos2(3,4,5), number# Setsos2number aj# Setpushtoanswerincomingcall(factory default) mt#Auto-answerandhandfreeincomingcall jy#Silencemonitoring dw#Checktheposition lag,1# ChangethelanguagetoChinese(factory default) lag,2#ChangethelanguagetoEnglish lag,3#ChangethelauguagetoRussian. tim,digital# Settingintervalofthepositiondata upload.(factorydefaultis10mins) gon# Turnonthetrackingfunction(factory default…
Text truncated - open the document above for the full version.
Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS EUT View 1 EUT View 2 Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 EUT View 3 EUT View 4 Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 EUT View 5 EUT View 6 Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 EUT View 7
Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 EXHIBIT 1 - PRODUCT LABELING Proposed FCC ID Label Format FCC ID: 2ABEYRF-V16 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Specifications: Text is Black in color and justified. Labels are printed in indelible ink on permanent adhesive silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Proposed Label Location on EUT FCC ID Label Location
Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 EXHIBIT 1 - PRODUCT LABELING Proposed FCC ID Label Format FCC ID: 2ABEYRF-V16 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Specifications: Text is Black in color and justified. Labels are printed in indelible ink on permanent adhesive silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. Proposed Label Location on EUT FCC ID Label Location
Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 EXHIBIT 3 - EUT INTERNAL PHOTOGRAPHS EUT Housing and Board View 1 EUT Housing and Board View 2 GSM Antenna Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 Solder Board-Component View 1 Solder Board-Component View 2 Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 Solder Board-Component View 3 Solder Board-Component View 4
Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 Report No.: STR13118314H Page 1 of 77 SAR Report FCC SAR Measurement and Test Report For Shenzhen Ruifenghuizhi Technology Co., Ltd. Room, 607B, East Block, NanFang Building, Futian District, Shenzhen, China. FCC ID: 2ABEYRF-V16 FCC Rules: FCC 47 CFR Part 2 (2.1093) ANSI/IEEE C95.1-1992 IEEE 1528-2003 FCC OET Bulletin 65C (Edition 01-01) Product Description: Mini GPS & SOS Communicator Tested Model: RF-V16 Report No.: STR13118314H Max. SAR Values: Body: 0.3106W/kg(1g) Tested Date: 2013-12-03 to 2013-12-05 Issued Date: 2013-12-06 Tested By: Silin Chen / Engineer Reviewed By: Lahm Peng / EMC Manager Approved & Authorized By: Jandy so / PSQ Manager Prepared By: Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao'an District, Shenzhen, P.R.C.(518101) Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen SEM. Test Technology Co., Ltd. Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 Report No.: STR13118314H Page 2 of 77 SAR Report TABLE OF CONTENTS 1. General Information ................................................................................................................................................... 3 1.1 Product Description for Equipment Under Test (EUT) ......................................................................................... 3 1.2 Test Standards .................................................................................................................................................... 4 1.3 Test Methodology ................................................................................................................................................ 4 1.4 Test Facility ......................................................................................................................................................... 4 2. Summary of Test Results .......................................................................................................................................... 5 3. Specific Absorption Rate (SAR) ................................................................................................................................ 6 3.1 Introduction .......................................................................................................................................................... 6 3.2 SAR Definition ..................................................................................................................................................... 6 4. SAR Measurement System ........................................................................................................................................ 7 4.1 The Measurement System .................................................................................................................................. 7 4.2 Probe ................................................................................................................................................................... 7 4.3 Probe Calibration Process ................................................................................................................................... 9 4.4 Phantom ............................................................................................................................................................ 10 4.5 Device Holder .................................................................................................................................................... 10 4.6 Test Equipment List ........................................................................................................................................... 11 5. Tissue Simulating Liquids ....................................................................................................................................... 12 5.1 Composition of Tissue Simulating Liquid ........................................................................................................... 12 5.2 Tissue Dielectric Parameters for Head and Body Phantoms ............................................................................. 13 5.3 Tissue Calibration Result ................................................................................................................................... 14 6. SAR Measurement Evaluation ................................................................................................................................ 15 6.1 Purpose of System Performance Check ............................................................................................................ 15 6.2 System Setup .................................................................................................................................................... 15 6.3 Validation Results .............................................................................................................................................. 16 7. EUT Testing Position ............................................................................................................................................... 17 7.1 Body Worn Position ........................................................................................................................................... 17 7.2 EUT Antenna Position ....................................................................................................................................... 17 7.3 EUT Testing Position ......................................................................................................................................... 18 8. SAR Measurement Procedures ...........................................................................................…
Text truncated - open the document above for the full version.
Ref : ACR.88.1.13.SATU.A Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao'an District, Shenzhen, P.R.C. (518101), CHINA SATIMO COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: SN 09/13 EP168 Calibrated at SATIMO US 2105 Barrett Park Dr. - Kennesaw, GA 30144 03/21/2013 Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed in SATIMO USA using the CALISAR / CALIBAIR test bench, for use with a SATIMO COMOSAR system only. All calibration results are traceable to national metrology institutions. COMOSAR E-Field Probe Calibration Report COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.88.1.13.SATU.A Page: 2/10 This document shall not be reproduced, except in full or in part, without the written approval of SATIMO. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of SATIMO. Name Function Date Signature Prepared by : Jérôme LUC Product Manager 3/28/2013 Checked by : Jérôme LUC Product Manager 3/28/2013 Approved by : Kim RUTKOWSKI Quality Manager 3/28/2013 Customer Name Distribution : Shenzhen SEM.Test Technology Co., Ltd. Issue Date Modifications A 3/28/2013 Initial release COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.88.1.13.SATU.A Page: 3/10 This document shall not be reproduced, except in full or in part, without the written approval of SATIMO. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of SATIMO. TABLE OF CONTENTS 1 Device Under Test ................................................................................................. 4 2 Product Description ................................................................................................ 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ............................................................................................. 4 3.1 Linearity ________________________________________________________________ 4 3.2 Sensitivity _______________________________________________________________ 5 3.3 Lower Detection Limit _____________________________________________________ 5 3.4 Isotropy _________________________________________________________________ 5 3.5 Boundary Effect __________________________________________________________ 5 4 Measurement Uncertainty ...................................................................................... 5 5 Calibration Measurement Results ........................................................................... 6 5.1 Sensitivity in air __________________________________________________________ 6 5.2 Linearity ________________________________________________________________ 7 5.3 Sensitivity in liquid ________________________________________________________ 7 5.4 Isotropy _________________________________________________________________ 8 6 List of Equipment ................................................................................................ 10 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.88.1.13.SATU.A Page: 4/10 This document shall not be reproduced, except in full or in part, without the written approval of SATIMO. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of SATIMO. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer Satimo Model SSE5 Serial Number SN 09/13 EP168 Product Condition (new / used) new Frequency Range of Probe 0.7 GHz-3GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.225 M Dipole 2: R2=0.235 M Dipole 3: R3=0.229 M A yearly calibration interval is recommended. 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION Satimo’s COMOSAR E field Probes are built in accordance to the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards. Figure 1 – Satimo COMOSAR Dosimetric E field Dipole Probe Length 330 mm Length of Individual Dipoles 4.5 mm Maximum external diameter 8 mm Probe Tip External Diameter 5 mm Distance between dipoles / probe extremity 2.7 mm 3 MEASUREMENT METHOD The IEEE 1528, OET 65 Bulletin C, CENELEC EN50361 and CEI/IEC 62209 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their affect. All calibrations / measurements performed meet the fore mentioned standards. 3.1 LINEARITY The evaluation of the linearity was done in free space using the waveguide, performing a power sweep to cover the SAR range 0.01W/kg to 100W/kg. COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.88.1.13.SATU.A Page: 5/10 This document shall not be reproduced, except in full or in part, without the written approval of SATIMO. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of SATIMO. 3.2 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards. 3.3 LOWER DETECTION LIMIT The lower detection limit was assessed using the same measurement set up as used for the linearity measurement. The required lower detection limit is 10 mW/kg. 3.4 ISOTROPY The axial isotropy was evaluated by exposing the probe to a reference wave from a standard dipole with the dipole mounted under the flat phantom in the test configuration suggested for system validations and checks. The probe was rotated along its main axis from 0 - 360 degrees in 15 degree steps. The hemispherical isotropy is determined by inserting the probe in a thin plastic box filled with tissue-equivalent liquid, with…
Text truncated - open the document above for the full version.
Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118314I-1 PAGE 1 OF 68 FCC PART 22H&24E FCC Part 22H & 24E Measurement and Test Report For Shenzhen Ruifenghuizhi Technology Co., Ltd. Room 607B, East Block, NanFang Building, Futian District, Shenzhen, China. FCC ID: 2ABEYRF-V16 FCC Rules: FCC Part 22H, FCC Part 24E Product Description: Mini GPS & SOS Communicator Tested Model: RF-V16 Report No.: STR13118314I-1 Tested Date: 2013-11-27 to 2013-12-09 Issued Date: 2013-12-11 Tested By: Susan Su / Engineer Reviewed By: Lahm Peng / EMC Manager Approved & Authorized By: Jandy so / PSQ Manager Prepared By: Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao'an District, Shenzhen, P.R.C (518101) Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen SEM.Test Technology Co., Ltd. Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118314I-1 PAGE 2 OF 68 FCC PART 22H&24E TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ............................................................................... 3 1.2 TEST STANDARDS ................................................................................................................................................... 4 1.3 TEST METHODOLOGY ............................................................................................................................................. 5 1.4 TEST FACILITY ....................................................................................................................................................... 5 1.5 EUT SETUP AND TEST MODE ................................................................................................................................. 5 2. SUMMARY OF TEST RESULTS ........................................................................................................................... 7 3. RF EXPOSURE ......................................................................................................................................................... 8 3.1 STANDARD APPLICABLE ......................................................................................................................................... 8 3.2 TEST RESULT.......................................................................................................................................................... 8 4. RF OUTPUT POWER .............................................................................................................................................. 9 4.1 STANDARD APPLICABLE ......................................................................................................................................... 9 4.2 TEST EQUIPMENT LIST AND DETAILS ..................................................................................................................... 9 4.3 TEST PROCEDURE ................................................................................................................................................... 9 4.4 ENVIRONMENTAL CONDITIONS ............................................................................................................................ 10 4.5 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 10 5. EMISSION BANDWIDTH ..................................................................................................................................... 13 5.1 STANDARD APPLICABLE ....................................................................................................................................... 13 5.2 TEST EQUIPMENT LIST AND DETAILS ................................................................................................................... 13 5.3 TEST PROCEDURE ................................................................................................................................................. 13 5.4 ENVIRONMENTAL CONDITIONS ............................................................................................................................ 13 5.5 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 14 6. OUT OF BAND EMISSIONS AT ANTENNA TERMINAL ............................................................................... 21 6.1 STANDARD APPLICABLE ....................................................................................................................................... 21 6.2 TEST EQUIPMENT LIST AND DETAILS ................................................................................................................... 21 6.3 TEST PROCEDURE ................................................................................................................................................. 21 6.4 ENVIRONMENTAL CONDITIONS ............................................................................................................................ 21 6.5 SUMMARY OF TEST RESULTS/PLOTS .................................................................................................................... 22 7. SPURIOUS RADIATED EMISSIONS .................................................................................................................. 38 7.1 MEASUREMENT UNCERTAINTY ............................................................................................................................ 38 7.2 STANDARD APPLICABLE .............................................…
Text truncated - open the document above for the full version.
Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 EXHIBIT 4 - TEST SETUP PHOTOGRAPHS Radio Test Setup Radio Test Setup (Below 30MHz) Shenzhen Ruifenghuizhi Technology Co., Ltd. Model: RF-V16 REPORT NO.: STR13118313I FCC PART 22 & 24 Radio Test Setup (30MHz to 1GHz) Radio Test Setup (Above 1GHz)
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 24E | 1.85 GHz - 1.91 GHz | 521.00 mW | 259KGXW | 0.037 ppm |

Real time tracker & alarm
Equipment Class
PCT - PCS Licensed Transmitter worn on body