FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. iRevo-ASSA ABLOY Korea/
  3. 2ABFG-IES-D320W-D0

2ABFG-IES-D320W-D0Yale Door Position Sensor

iRevo-ASSA ABLOY Korea
Yale Door Position Sensor - FCC ID 2ABFG-IES-D320W-D0 - iRevo-ASSA ABLOY Korea
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 22, 2022
Application Purpose
Original Equipment
Date of Application
Nov 22, 2022
Equipment Note
Yale Door Position Sensor
Frequency Range
2402.00000000 - 2480.00000000
Company
iRevo-ASSA ABLOY Korea
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Internal SAHARA MANUAL Sahara Manual Internal Alarm Assembly point Emergency exit Emergency number First aid kit Protective equipment Stay home if you have flu symptoms Keep your distance Wash/sanitize hands Safety first 2 Internal 3 Sahara is a dry contact device that is built with Wi-Fi and Bluetooth connections that allow the Yale Access app to send an electric strike to a GDO (Garage door opener) or Gate automation device that is it connected to. As part of its offering, we have also included a wireless DPS that will provide the end user with the correct state of the gate/ garage door. Through the use of both devices, the end user can now control access into the garage or through their gate and also see what state the door is in. Wireless DPS Internal 4 Gate Application. Step one. •Remove Sahara from the box. Step two •Download the Yale Access App. Step 3 •Scan the QR code on the Sahara an wireless DPS device that will take you through the registration process of your device on the Yale Access app and add the device to WiFi. Step 4 •Hardware installation should now take place. The End user will be taken through a step-by-step guide on the Yale access app on how to install their Sahara, wireless DPS and magnet on a generic Gate Automation device (See hardware installation part to the right) Step 5 •End user asked to test whether the device works after Sahara hardware installation is done Step 6 •Now end users can use Sahara to open or close their gate (See example below). Hardware installation. Step one •The end user is asked to power down their Gate Automation device in order to avoid any electric interface and dangerous encounters. Step two •The end user should then take the wires coming out of the ‘NO’ (Normally open), ‘Com1’ ports, and power supply ( 5V/ 24V) of the Sahara and connect these to the relevant ports on a Gate Automation device. (As every automation device has its own port locations, this connection method will be shown to them through a wiring compatibility checker on the app and the website) Step three •Once installed, the end user is asked to power up their Gate Automation device if the LED light on the Sahara turns on then power is now available on the device. Step four •The end user will be asked to power the wireless DPS and then attach it to the gate door and take the magnet that comes with it and attach it to the pillar of the gate which will allow the app to know the state of the gate. Step Five •This is an optional step for end users. If they have a ‘request for exit’ switch inside their garage they can connect this to the rex1 or rex2 ports and so then they can continue to open and close their garage through the switch Wireless DPS Internal 5 Garage Application. Step one. •Remove Sahara from the box. Step two •Download the Yale Access App. Step 3 •Scan the QR code on the Sahara and wireless DPS device that will take you through the registration process of your device on the Yale Access app and add the device to WiFi. Step 4 •Hardware installation should now take place. The End user will be taken through a step-by-step guide on the Yale access app on how to install their Sahara on a generic garage door opener (See hardware installation part to the right) Step 5 •End user asked to test whether the device works after Sahara hardware installation is done Step 6 •Now end users can use Sahara to open or close their garage door. (See example below). Hardware installation. Step one •The end user asked to power down their Garage door opener in order to avoid any electric interface and dangerous encounters. Step two •The end user should connect the wires from the ‘NO’ (Normally open), ‘Com1’ ports, and power supply ( 5V/ 24V) of the Sahara and connect these to the relevant ports on a garage door opener. (As every automation device has its own port locations, this connection method will be shown to them through a wiring compatibility checker on the app and the website) Step three •Once installed, the end user is asked to power up their garage door opener and if the LED light on the Sahara turns on then power is now available on the device Step four •The end user will be asked to power the wireless DPS and then attach it to the inside of the garage door allowing the app to know the state of the garage Step five •This is an optional step for end users. If they have a ‘request for exit’ switch inside their garage they can connect this to the rex1 or rex2 ports and so then they can continue to open and close their garage through the switch Wireless DPS Internal FCC-ISED Manual information 6 Attached is PDF with FCC and ISED Information to be added to the Manual. Internal FCC Warning 7 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipmen…

Text truncated - open the document above for the full version.

Cover Letter(s)

iRevo-ASSAABLOYKorea AgentAuthorization Company:iRevo-ASSAABLOYKorea Address:10fofJEIPLATZBldg.,186,Gasandigital1-ro,Geumcheon-gu,SeoulSouth Korea ModelNumber(s):M2 ProductDescription:YaleDoorPositionSensor WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:Nov.17,2022 Name: Title: Company: iRevo-ASSAABLOYKore Soo-Kyung Jang Program Manager a

Cover Letter(s)

iRevo-ASSAABLOYKorea OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2022-11-11 Subject;RequestforConfidentiality FCCID:2ABFG-IES-D320W-D0 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name:Soo-Kyung Jang Title: Program Manager

External Photos

FCCID:2ABFG-IES-D320W-D0 External

ID Label/Location Info

IC

Internal Photos

FCCID:2ABFG-IES-D320W-D0 Internal

RF Exposure Info

TRFNo.FCCRFExposure_R1 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 1 of3 RFExposureEvaluation FCCID:2ABFG-IES-D320W-D0 ApplicableStandard AccordingtoFCCpart2.1093andpart1.1307(b)(3),systemsoperatingundertheprovisionsofthissectionshallbe operatedinamannerthatensurethatthepublicisnotexposedtoradiofrequencyenergylevelinexcessofthe Commission'sguideline KDB447498D04InterimGeneralRFExposureGuidancev01,clause2.1.3SAR-BasedExemption: Amorecomprehensiveexemption,consideringavariablepowerthresholdthatdependsonboththeseparationdistance andpower,isprovidedin1.1307(b)(3)(i)(B).Thisexemptionisapplicabletothefrequencyrangebetween300MHzand6 GHz,withtestseparationdistancesbetween0.5cmand40cm,andforallRFsourcesinfixed,mobile,andportable deviceexposureconditions Accordingly,aRFsourceisconsideredanRFexemptdeviceifitsavailablemaximumtimeaveraged(matched conducted)poweroritseffectiveradiatedpower(ERP),whicheverisgreater,arebelowaspecifiedthreshold. Note:fisinGHz,distheseparationdistance(cm) Table1-ExamplePowerThresholds(mw) TESTRESULT PassedNotApplicable TRFNo.FCCRFExposure_R1 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou,Shajing, Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com Page 2 of3 BLE Test mode Channel Frequenc y (MHz) Max. Measure dPower (dBm) Tune up tolera nce (dBm) Max. Tune up Powe r (dBm) AntennaGainERP Evaluati on distance cm Exempti onLimit (mW) (dBi)(dBd) dBmmw BLE_1M/ 2M 24021.95 ±1 22.460.312.261.68 0.5 2.7 Note: -Thetune-uppowerwasdeclaredbytheapplicant -dBi=dBd+2.15 -Themaximumantennagainis2.46dBi. -TomaintaincompliancewiththeRFexposureguidelines,placetheequipmentlessthan0.5cmfromnearbypersons Result:Compliant --THEEND--

Test Report

Confidential Data Project Name: M2 Update: 2021-01- Author: 杨永成 YangYongCheng 27 Antenna Test Report Index: 1.Overview 2.Revision History 3.Test Item &Equipment 4.Matching Circuit 5.SParameter Test 6.Active Test 7.Conducted EmissionTest 8.Environmental Processing Confidential Data 项目概况 OverView CUSTOMER NAME 华创恒达 PROJECT NAMEM2 ItemsDetails •FREQUENCY2400MHz-2500MHz •PROJECT TYPE •ANTENNA SPACE •FEED & GROUNDPAD •SENSITIVE ELEMENTS •ANTENNA TYPE •PCB •OTHERS Confidential Data 日期(Date) 版本 (Revision) 负责人(Author)更改原因(Description of changes) 历史报告记录 Revision History Confidential Data ListTest ItemEquipment 1.SParameterVSWR, Return LossAgilent VNA 2.Active Test TRP, TISAgilent 8960 RayZone1800 3.Passive TestGain, Efficiency, PatternAgilent E5071C Test Item & Equipment Confidential Data 2021/1/28 天线 ANT Confidential Data VSWR Confidential Data Smith Confidential Data PASSIVE TEST(天线效率及增益) Freq (MHz) Effi (%)Gain(dB) 240046.152.18 241050.852.45 242050.882.40 243051.032.41 244050.302.38 245049.332.28 246050.702.28 247052.052.36 248051.292.46 249051.162.44 250051.132.33 Confidential Data 3D Antenna Radiation Pattern(2450MHz) Confidential Data 2D Antenna Radiation Pattern(2400MHz)

Test Report

Page 1 of 74ReportNo.: KS2210S4651E01 TRF EMC_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TEST REPORT ReportNo. ............................... :KS2210S4651E01 FCCID.....................................:2ABFG-IES-D320W-D0 Applicant..................................:iRevo- ASSAABLOYKorea Address .................................... : 10f of JEI PLATZBldg.,186, Gasandigital1-ro,Geumcheon-gu,SeoulSouth Korea Manufacturer...........................:WuhanYixinTechnologyCo., Ltd Address....................................: Room02, 4/F, building10, Sun city,Gezhouba,No.40,Gaoxin4th Road, East LakeNew TechnologyDevelopmentZone,WuhanCity, Hubei Province,China. ProductName.........................:Yale DoorPositionSensor Trademark ............................... :Yale Model/Typereference ............ :M2 Standard .................................. :47 CFRPart 15.247 Dateof Receipt.......................:November3, 2022 Dateof Test Date....................:November3, 2022to November9, 2022 Dateof issue...........................:November10, 2022 Test result ............................... :Pass Preparedby: ( Printedname+ Signature) Pai Zheng Approvedby: ( Printedname+ Signature)Sky Dong TestingLaboratoryName ... :KSIGN(Guangdong)TestingCo., Ltd. Address....................................: WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrial Park,Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong, China This test reportmay be duplicatedcompletelyfor legaluse with the approvalof the applicant.It shouldnot be reproducedexceptin full, withoutthe writtenapprovalof our laboratory.The clientshouldnot use it to claim productendorsementby KSIGN.The test resultsin the reportonly applyto the testedsample.The test report shall be invalidwithoutall the signaturesof testingengineers,reviewerand approver.Any objectionsmustbe raisedto TSTLMSwithin15 dayssincethe datewhenthe reportis received.It will not be takeninto considerationbeyondthis limit. The test reportmerelycorrespondsto the test sample.The reportis invalidif it is not stampedwith the "TestingSpecialStamp"and the "RidingSeamStamp". Page 2 of 74ReportNo.: KS2210S4651E01 TRF EMC_R1 Add:WestSide of 1/F., BuildingC, ZoneA, FuyuanNew Factory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel: +(86)0755-29852678Fax: +(86)0755-29852397E-mail:[email protected]:www.gdksign.com TABLEOF CONTENTSPage 1. TEST SUMMARY.............................................................................................................................................4 1.1. Test Standards.......................................................................................................................................4 1.2. ReportVersion.......................................................................................................................................4 1.3. Test Description......................................................................................................................................5 1.4. Test Facility.............................................................................................................................................6 1.5. MeasurementUncertainty......................................................................................................................7 2. GENERALINFORMATION..............................................................................................................................8 2.1. GeneralDescriptionOf EUT ..................................................................................................................8 2.2. AccessoryEquipmentInformation.........................................................................................................8 2.3. Descriptionof Test Modes......................................................................................................................8 2.4. MeasurementInstrumentsList ...............................................................................................................9 3. EVALUATIONRESULTS(EVALUATION).....................................................................................................13 3.1. Antennarequirement............................................................................................................................13 3.1.1.E.U.T.Operation:........................................................................................................................13 3.1.2.Test Data:...................................................................................................................................13 4. RADIOSPECTRUMMATTERTEST RESULTS(RF) ...................................................................................14 4.1. OccupiedBandwidth............................................................................................................................14 4.1.1.E.U.T.Operation:........................................................................................................................14 4.1.2.Test SetupDiagram:...................................................................................................................14 4.1.3.Test Data:...................................................................................................................................14 4.2. MaximumConductedOutputPower....................................................................................................15 4.2.1.E.U.T.Operation:........................................................................................................................15 4.2.2.Test SetupDiagram:...................................................................................................................16 4.2.3.T…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2ABFG-IES-D320W-D0 Emissionsinrestrictedfrequencybands(below1GHz) Emissionsinrestrictedfrequencybands(above1GHz)

Contact Information

Applicant

Soo-Kyung Jang
[email protected]+82-2-2107-5741Fax: +82-2-865-3933

Technical Contact

iRevo - ASSA ABLOY Korea

South Korea

Test Firm

KSIGN (Guangdong) Testing Co., Ltd.Neil Wan
[email protected]+(86) 0755-2985 2678

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.57 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from iRevo-ASSA ABLOY Korea

2ABFG-ML55RA

Wireless Communication Systems

Jul 28, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Yale Smart Opener-Garage - FCC ID 2ABFG-YRDC2 - iRevo-ASSA ABLOY Korea
2ABFG-YRDC2

Yale Smart Opener-Garage

Dec 14, 2022

Equipment Class

DTS - Digital Transmission System
Digital Door Lock - FCC ID 2ABFG-YRIZW2USTS2 - iRevo-ASSA ABLOY Korea
2ABFG-YRIZW2USTS2

Digital Door Lock

Aug 27, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Digital Door Lock - FCC ID 2ABFG-YRIZW2USPB2 - iRevo-ASSA ABLOY Korea
2ABFG-YRIZW2USPB2

Digital Door Lock

Aug 25, 2022

Equipment Class

JAB - Part 15 Class B Digital Device
Digital Door Lock - FCC ID 2ABFG-YRD450BLEV1 - iRevo-ASSA ABLOY Korea
2ABFG-YRD450BLEV1

Digital Door Lock

May 01, 2022

Equipment Class

DTS - Digital Transmission System