FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Appion Inc./
  3. 2ABH9-WS130

2ABH9-WS130PRECISION SCALE

Appion Inc.
PRECISION SCALE - FCC ID 2ABH9-WS130 - Appion Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 07, 2024
Application Purpose
Original Equipment
Date of Application
Oct 07, 2024
Equipment Note
PRECISION SCALE
Frequency Range
2402.00000000 - 2480.00000000
Company
Appion Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PATENT INFO AT APPIONTOOLS.COM - © 2024 APPION INC. ALL RIGHTS RESERVED TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT. WS130 OPERATION MANUAL © 2024 APPION INC. ALL RIGHTS RESERVED 2 Table of Contents Introduction....................................................................................................................3 Warnings and Safety Information.......................................................................4 Refrigerant Storage Container Safety..............................................................5 Scale Components......................................................................................................7 General Functions.......................................................................................................8 Using the WS130......................................................................................................12 Appion Central™ Bluetooth® Operation.........................................................13 Calibrate Scale............................................................................................................14 Appion Central™ App..............................................................................................16 Refrigerant Recovery Tips.....................................................................................17 General Maintenance and Care.........................................................................21 Specifications.......................................................................................................22 Regulatory Information...........................................................................................24 Warranty Information...............................................................................................26 QR Code Index...........................................................................................................28 Contact........................................................................................................................29 WS130 OPERATION MANUAL © 2024 APPION INC. ALL RIGHTS RESERVED 3 Introduction Thank you for choosing the WS130 Precision Scale, where portability meets precision. This compact, lightweight measurement tool packs a powerful punch and is designed for the HVAC-R technician on the go. Its durable construction and wide measurement range make it perfect for a variety of systems. With its robust build and seamless integration with the Appion Central™ app, the WS130 is designed to simplify your workflow without sacrificing reliability. Ideal for smaller systems and tight spaces, the WS130 boasts a generous measurement range for its size. Effortlessly manage refrigerant charges and track usage directly through the Appion Central™ app, where real-time readings pair with advanced features like data logging and recovery cylinder management. Experience freedom and precision with the WS130 – your essential companion for efficient HVAC-R servicing. WS130 OPERATION MANUAL © 2024 APPION INC. ALL RIGHTS RESERVED 4 Warnings and Safety Information • Never store the measuring instrument together with solvents. • Operate the measuring instrument only within the parameters specified in this manual. • Do not expose the measuring instruments or equipment to temperatures outside of the stated operating temperatures. • Use only specified batteries (AA Batteries). • Do not use leaky or damaged batteries. • Batteries must only be changed in a non-hazardous area. • Battery operating temperatures may vary by manufacturer. The batteries supplied with this unit are for storage and operating temperatures between 32°F - 104°F (0°C - 40°C). • Dispose of batteries in accordance with any applicable local law and regulations. • Do not dispose of the product or battery in a fire or heat above 212°F (100°C). • Remove batteries before storing the device for long periods of time. • Always ground recovery cylinders to a known good ground to avoid static buildup in the recovery cylinder. WS130 OPERATION MANUAL © 2024 APPION INC. ALL RIGHTS RESERVED 5 Refrigerant Storage Container Safety What Can Happen: Refrigerant storage containers may vent or explode when the working pressure of the container is exceeded. How To Prevent It: Refrigerant storage containers are designed with different working pressures. Verify that the rating of the storage cylinder is appropriate for the refrigerant being recovered. For R-410A, 4BA400 and 4BW400 are appropriate ratings for refrigerant storage containers. What Can Happen: “80% Shut Off Switches,” also known as Tank Overfill Sensors and Overfill Protection Devices, may fail to prevent overfilling of the storage cylinder leading to venting or explosion. These sensors only cut power to the recovery machine, and do not stop the flow of refrigerant, which may continue due to a siphon, or due to temperature-induced migration. How To Prevent It: Do not rely on these switches to prevent overfilling. Only a refrigerant scale can provide an active and accurate measurement of the amount of refrigerant in the storage container. Do not rely on these switches to stop the flow of refrigerant into the container. Only the valves on the recovery machine and on the cylinder can stop the flow of refrigerant into the container. WS130 OPERATION MANUAL © 2024 APPION INC. ALL RIGHTS RESERVED 6 Refrigerant Storage Container Safety (cont.) What Can Happen: Refrigerant expands when heated (Diagram 1), and storage containers may vent or explode when filled over 80% capacity. How To Prevent It: A refrigerant scale must be used to monitor the amount of refrigerant in the storage container. Be sure to close the valves on the storage container when it has reached 80% capacity. Filled to 80% Capacity Filled to 90% Capacity Diagram 1: Overfilled storage containers may explode due to liquid refrigerant expanding when heated. Transportation of refrigerant storage cy…

Text truncated - open the document above for the full version.

Attestation Statements

Grantee also Agent for Service of Process_FCC_Attestation Statements_Kiwa Page 1 of 2 RF_754_02 15-02-2023 Appion Inc. 2800 South Tejon Street Englewood, CO 80110 USA U.S. Agent Designation for Service of Process (Applicant is Both Grantee and U.S. Agent) TO: Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTENTION: FCC Certification – Section 2.911(d)(7) Information This letter is to confirm that the Applicant will also serve as the U.S. Agent for Service of Process as required by 47 CFR 2.911(d)(7). The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The Applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information changes. Applicant & Agent Company name: Appion Inc. FRN: 0023199409 Contact person name: Robert Morris Agent name: Appion Inc. Street address: 2800 South Tejon Street Englewood, ZIP/City/State CO 80110 USA Telephone number: (303) 937-1580 Email address: [email protected] Signature Contact person*: Date: Robert Morris 2024/09/18 Signature Agent*: Date: 2024/09/18 Note *Must be signed by both the applicant, and agent on behalf

Attestation Statements

Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_02 15-02-2023 Appion Inc. 2800 South Tejon Street Englewood, CO 80110 USA Certification Application Attestation Statements <Company name> Appion Inc. 2800 South Tejon Street Englewood, CO 80110 USA Subject: FCC ID: <2ABH9-WS130> To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) [Appion Inc.] certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) [Appion Inc.] (“the applicant”) certifies that, as of the date of the filing of this application, the applicant ☐ - is / ☒- is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 2024/09/18 City: Englewood Name (2) : Robert Morris Function: Product Designer Telephone number: (303) 937-1580 Email address: [email protected] Signature: Revision Record Sheet: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK”

Cover Letter(s)

RF_160_05 Declaration of Authorisation Date of issue 02-01-2023 (O n manufacturer’s company letter heading) Declaration of Authorization We Name: Address: City: Country: Appion Inc. 2800 South Tejon Street Englewood, CO 80110 USA Dec lare that: Nam e Representative of agent: Chieh Tseng Agent Company name: Worldwide Testing Services (Taiwan) Co., Ltd Address: 6F., No. 58, Lane 188, Ruey Kuang Road, Neihu district, City: Taipei 114, Country Taiwan is authorized to apply for Certification of the following product(s): Product description: PRECISION SCALE Type designation: WS130 Trademark: APPION Validity/ expiry date on our behal f. Date: 2024/09/18 Ci ty: Englewood Nam e: Robert Morris Functi on: Product Designer Si gnature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

Cover Letter(s)

FCC, Request for non-disclosure Date: 02- 01-2022 RF_501, Issue 10 Company Name: Appion Inc. Address : 2800 South Tejon Street Englewood, City:CO 80110 Country:USA To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: 2ABH9-WS130 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: ☐ Bill(s) of Material ☒ B lo c k D ia g ra m s ☒ Operational Description ☒ Schem atic D iagram s ☐ Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): ☐ Internal Photos ☐ U ser’s M anual ☐ Test Set-up Photos ☐ External Photos Justification: Date: 2024/09/18 Name and signature of applicant: Robert Morris Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period

External Photos

Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 18 External Photos Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 18 Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 18 Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 18 Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 18 Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 18

ID Label/Location Info

D C B A 4321 D C B A 4321 APPION WS130 LABEL ManufacturerAppion Inc.

Internal Photos

Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 8 of 18 Internal Photos Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 9 of 18 Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 10 of 18 Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 11 of 18 Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 12 of 18 Registration number: W6M22408-23653-FCC FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 13 of 18

RF Exposure Info

of Applicant: Appion Inc. Address: 2800 South Tejon Street Englewood, CO 80110 USA Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22408-23653-EE 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] FCC RF Exposure Exemption report for PRECISION SCALE Model No.: WS130 FCC ID: 2ABH9-WS130 Registration number: W6M22408-23653-EE FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 8 TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................................................... 2 1.1 NOTES ...................................................................................................................................................................... 2 1.2 TESTING LABORATORY ............................................................................................................................................. 3 1.2.1 Location .............................................................................................................................................................. 3 1.2.2 Details of accreditation status ............................................................................................................................ 3 1.3 DETAILS OF APPROVAL HOLDER ............................................................................................................................... 3 1.4 APPLICATION DETAILS .............................................................................................................................................. 4 1.5 GENERAL INFORMATION OF TEST ITEM ..................................................................................................................... 4 1.6 TEST STANDARDS ..................................................................................................................................................... 4 2 TECHNICAL TEST ........................................................................................................................................................ 5 2.1 SUMMARY OF TEST RESULTS ..................................................................................................................................... 5 2.2 TEST ENVIRONMENT ................................................................................................................................................. 5 2.3 TEST EQUIPMENT LIST .............................................................................................................................................. 5 3 RF EXPOSURE TEST EXEMPTIONS ........................................................................................................................ 6 4 EXEMPTION CALCULATION.................................................................................................................................... 8 Registration number: W6M22408-23653-EE FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 8 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: September 18, 2024 Rick Chen Date WTS-Lab. Name Signature Technical responsibility for area of testing: September 18, 2024 Kevin Wang Date WTS Name Signature Registration number: W6M22408-23653-EE FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 8 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) Xizhi Lab No. 99, Sec. 1, Balian Rd., Xizhi Dist., New Taipei City 221032, Taiwan (R.O.C.) Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114 , Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. Name: ./. Accredited no.: ./. Street: ./. Town: ./. Country: ./. 1.3 Details of approval holder Name: Appion Inc. Street: 2800 South Tejon Street City: Englewood, CO 80110 Country: USA Manufacturer: (if applicable) Name: ./. Street: ./. Town: ./. Country: ./. Registration number: W6M22408-23653-EE FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Page 4 of 8 1.4 Application details Date of receipt of test item: August 13, 2024 Date of test: from August 14, 2024 to September 18, 2024 1.5 General information of Test item Type of test item: PRECISION SCALE Model …

Text truncated - open the document above for the full version.

Test Report

EL BLE ECTRICA Antenna Frequen Gain : -3 Beaco AL SPEC a Type : P ncy : 2.4-2 3dBi (Mea on emi (5634 CIFICATIO PCB(Printed 2.5GHz an Simulat ission 44 BM ONS d Circuit B tion Resul n modu 7161) Board) ts) ule anttenna ME ECHANIC Size W x CAL SPE x L x H CIFICAT : 12.00 TIONS X 6.40 xx1.0 mm

Test Report

of Applicant: Appion Inc. Address: 2800 South Tejon Street Englewood, CO 80110 USA Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22408-23653-C-1 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] 47 CFR PART 15 SUBPART C TEST REPORT for PRECISION SCALE Model No.: WS130 FCC ID: 2ABH9-WS130 Registration number: W6M22408-23653-C-1 FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 23 TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................................................... 2 1.1 NOTES ...................................................................................................................................................................... 2 1.2 TESTING LABORATORY ............................................................................................................................................. 3 1.2.1 Location .............................................................................................................................................................. 3 1.2.2 Details of accreditation status ............................................................................................................................ 3 1.3 APPLICATION DETAILS .............................................................................................................................................. 3 1.4 GENERAL INFORMATION OF TEST ITEM ..................................................................................................................... 4 1.5 DUTY CYCLE AND FACTOR ........................................................................................................................................ 4 1.6 TEST STANDARDS ..................................................................................................................................................... 5 2 TEST CONFIGURATION ............................................................................................................................................. 6 2.1 TEST ENVIRONMENT ................................................................................................................................................. 6 2.2 MEASUREMENT UNCERTAINTY ................................................................................................................................. 6 2.3 TEST EQUIPMENT LIST .............................................................................................................................................. 7 3 TEST RESULTS (ENCLOSURE) ................................................................................................................................. 8 3.1 PEAK OUTPUT POWER (TRANSMITTER) ..................................................................................................................... 9 3.2 SPURIOUS EMISSIONS RADIATED – TRANSMITTER OPERATING ............................................................................... 12 3.3 EMISSIONS IN NONRESTRICTED FREQUENCY BANDS ................................................................................................ 14 3.4 MINIMUM 6 DB BANDWIDTH .................................................................................................................................. 16 3.5 PEAK POWER SPECTRAL DENSITY .......................................................................................................................... 19 3.6 POWER LINE CONDUCTED EMISSION ...................................................................................................................... 22 Appendix: Diagrams Registration number: W6M22408-23653-C-1 FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 23 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: September 18, 2024 Rick Chen Date WTS-Lab. Name Signature Technical responsibility for area of testing: September 18, 2024 Kevin Wang Date WTS Name Signature Registration number: W6M22408-23653-C-1 FCC ID: 2ABH9-WS130 Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 23 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) Xizhi Lab No. 99, Sec. 1, Balian Rd., Xizhi Dist., New Taipei City 221032, Taiwan (R.O.C.) Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114 , Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed t…

Text truncated - open the document above for the full version.

Test Report

Operator: Temperature:24.8 °C File :3Data :#2Date: 2024/8/20 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Kai Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:49.8 % Time: 下午 03:36:16 Condition : EUT : M/N: Note : TX 2480MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22408-23653 Test Mode : Polarization: Horizontal Distance: 3m 4.5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *4960.00050.8845.6174.00-23.12peak5.27150183 7440.00045.5933.4374.00-28.41peak12.161501 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.8 °C File :3Data :#7Date: 2024/8/20 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Kai Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:49.8 % Time: 下午 03:39:00 Condition : EUT : M/N: Note : TX 2480MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22408-23653 Test Mode : Polarization: Vertical Distance: 3m 4.5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *4960.00051.6346.3674.00-22.37peak5.27150195 7440.00044.3032.1474.00-29.70peak12.161501 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.8 °C File :3Data :#3Date: 2024/8/20 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Kai Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:49.8 % Time: 下午 03:37:05 Condition : EUT : M/N: Note : TX 2480MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22408-23653 Test Mode : Polarization: Horizontal Distance: 3m 4.5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment 9920.00045.2731.7474.00-28.73peak13.53150159 *12400.00050.3032.6874.00-23.70peak17.62150234 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.8 °C File :3Data :#8Date: 2024/8/20 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Kai Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:49.8 % Time: 下午 03:39:42 Condition : EUT : M/N: Note : TX 2480MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22408-23653 Test Mode : Polarization: Vertical Distance: 3m 4.5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment 9920.00045.4831.9574.00-28.52peak13.531503 *12400.00050.3732.7574.00-23.63peak17.62150268 *:Maximum data x:Over limit !:over margin Operator: Temperature:24.8 °C File :3Data :#4Date: 2024/8/20 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Kai Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:49.8 % Time: 下午 03:37:21 Condition : EUT : M/N: Note : TX 2480MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22408-23653 Test Mode : Polarization: Horizontal Distance: 3m 4.5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *:Maximum data x:Over limit !:over margin Operator: Temperature:24.8 °C File :3Data :#9Date: 2024/8/20 Radiated Emission Measurement Address:No.99,Sec.1,Balian Rd.,Xizhi Dist.,New Taipei City Kai Tel:+886-2-2646-1508 Fax:+886-2-2646-1533 Humidity:49.8 % Time: 下午 03:39:58 Condition : EUT : M/N: Note : TX 2480MHz FCC_part 15 RE-Class C_Above 1GHz_PK W6M22408-23653 Test Mode : Polarization: Vertical Distance: 3m 4.5 Vd.c. Power : Mk. Frequency (MHz) Reading (dBuV) Corr. factor (dB/m) Result (dBuV/m) Limit (dBuV/m) Margin (dB) Ant.Pos (cm) Tab.Pos (deg.) Detector Site : 966A Chamber Comment *:Maximum data x:Over limit !:over margin Opera…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Robert Morris(Product Designer)
[email protected](303) 937-1580Fax: (303) 937-1599

Technical Contact

Worldwide Testing Services (Taiwan) Co., Ltd.Kevin Wang
[email protected]+886266068877

6F., No.58, Lane 188, Ruey Kuand Rd., · Taiwan

Non-Technical Contact

Worldwide Testing Services (Taiwan) Co., Ltd.Chieh Tseng
[email protected]+886266068877

Test Firm

Worldwide Testing Services (Taiwan) Co., Ltd.Rex Kao
[email protected]886-2-6606-8877Fax: 886-2-6606-8879

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz400.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted.

Other Applications from Appion Inc.

Refrigeration Scale - FCC ID 2ABH9-WS260 - Appion Inc.
2ABH9-WS260

Refrigeration Scale

Jan 10, 2024

Equipment Class

DTS - Digital Transmission System
Relative Humidity Temperature Gauge - FCC ID 2ABH9-RHT100 - Appion Inc.
2ABH9-RHT100

Relative Humidity Temperature Gauge

Feb 20, 2023

Equipment Class

DTS - Digital Transmission System
VACUUM GAUGE WITH BLUETOOTH - FCC ID 2ABH9-AV760 - Appion Inc.
2ABH9-AV760

VACUUM GAUGE WITH BLUETOOTH

Jan 17, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
PRESSURE GAUGE WITH BLUETOOTH - FCC ID 2ABH9-MSD1PG - Appion Inc.
2ABH9-MSD1PG

PRESSURE GAUGE WITH BLUETOOTH

Jan 17, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter