Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
REMOTE CONTROL OF BATTERY PUMP KIT OPERTATION INSTRUCITONS Note: Before starting of installation please read this leaflet and keep it carefully. 1. OVERVIEW The remote control of battery pump kit is designed for fountain use. 2. MAIN PARAMETER 1) Model: B164-RC 2) Ratings: Battery 4.5V 3) Adapter Input: AC 120V/60Hz ; Output: DC 7V 4) Operating frequency: 433.77 MHz by ASK Modulation 3. ASSEMBLY 1) Unpack all components carefully. 2) Used the remote control to turn on/off or timer the fountain. 3) Lower battery, please used the adaptor to recharges the battery unit. 4. CAUTIONS 1) DANGER: Do not store battery in an airtight container as it may cause an explosion. 2) WARNING: When using electric devices, basic safety precautions should always be followed to reduce the risk of fire, electric shock and personal injury, including the following FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: Modifications to this product will void the user’s authority to operate this equipment.
FCC ID: 2ABMJ-TX opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3131210-01156-EF Page 1 of 2 1 External Photos of the EUT External view-1 External view-2 External view-3 FCC ID: 2ABMJ-TX opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3131210-01156-EF Page 2 of 2 External view-4 External view-5 External view-6
FCC ID: 2ABMJ-TX Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3131210-01156-EF Page 1 of 1 LABEL PHOTOGRAPHS Label Location
FCC ID: 2ABMJ-TX opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3131210-01156-EF Page 1 of 2 1 Internal Photos of the EUT Internal view-1 PCB view-1 FCC ID: 2ABMJ-TX opyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3131210-01156-EF Page 2 of 2 PCB view-2 Oscillator view
CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC ID TEST REPORT TEST REPORT NUMBER : CGZ3131210-01156-EF CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China FCC ID: 2ABMJ-TX Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3131210-01156-EF Page 1 of 29 TEST REPORT For FCC ID Report Reference No. ..................... CGZ3131210-01156-EF Date of issue......................................17 December 2013 Testing Laboratory Name ...............CENTRE OF TESTING SERVICE CO., LTD. Address.............................................. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Testing location/ procedure ............... Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s name .............................Yeiser Research & Development, LLC Address..............................................9338 Bond Avenue,El Cajon,CA 92021 USA Test specification ............................ Standard ............................................ 47 CFR PART 15 OCT, 2012 , ANSI C63.4-2009 Test Report Form No. .....................CTSEMC-1.0 TRF Originator ...................................CENTRE OF TESTING SERVICE CO., LTD. Master TRF........................................Dated 2009-01 CENTRE OF TESTING SERVICE CO., LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the CENTRE OF TESTING SERVICE CO., LTD is acknowledged as copyright owner and source of the material. CENTRE OF TESTING SERVICE CO., LTD takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ....................:Remote control of battery pump kit Trade Mark ......................................./ Manufacturer...................................../ Model/Type reference....................... B164-RC Ratings.............................................. Battery 4.5V Operating Frequency.........................433.77 MHz Result ................................................ PASSED Compiled by: Supervised by: Approved by: Kate zhang / Fileadministrators Duke yang / Technique principal Vincent yao / Manager FCC ID: 2ABMJ-TX Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3131210-01156-EF Page 2 of 29 FCC ID -- T E S T R E P O R T Test Report No. : CGZ3131210-01156-EF 17 December 2013 Date of issue Type / Model............................ B164-RC EUT.......................................... Remote control of battery pump kit Applicant........................... Yeiser Research & Development, LLC Address.................................... 9338 Bond Avenue,El Cajon,CA 92021 USA Telephone................................ + 619 449 2392 Fax........................................... + 619 449 3506 Contact..................................... Richard Henderson Manufacturer...................... / Address.................................... / Telephone................................ / Fax........................................... / Contact..................................... / Factory ............................ / Address.................................... / Telephone................................ / Fax........................................... / Contact..................................... / Test Result according to the standards on page 3:PASSED The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. FCC ID: 2ABMJ-TX Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3131210-01156-EF Page 3 of 29 TABLE OF CONTENTS Description Page 1. TEST STANDARDS.......................................................................................................................................5 2. SUMMARY ....................................................................................................................................................5 2.1 GENERAL REMARKS .......................................................................................................................................5 2.2 FINAL ASSESSMENT........................................................................................................................................5 3. EQUIPMENT UNDER TEST..........................................................................................................................6 3.1 POWER SUPPLY SYSTEM UTILISED..........................................................................................................................6 3.2 SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT).............................................…
Text truncated - open the document above for the full version.
FCC ID: 2ABMJ-TX Copyright of this report is owned by Centre of Testing Service and may not be reproduced other than in full except with the written approval of the issuing Company. CENTRE OF TESTING SERVICE CO., LTD. A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, China Tel:+86-20-85543113 (32 lines) Fax:+86-20-38780406 Complaint line:+86-20-85533471 E-mail:[email protected] See Reverse For Terms And Conditions of Service Report No.: CGZ3131210-01156-EF Page 1 of 1 TEST PHOTOGRAPHS 1. Photos of TX Radiated Emission Test (In Anechoic Chamber) Below 30MHz Below 1GHz Above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.77 MHz - 433.77 MHz | - |

Remote control battery pump kit
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Remote Control of battery pump kit
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Bluetooth Music Fountain
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Remote Control Receiver of Battery Pump Kit
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter