79-15053-00 REV. D4 www.srsmith.com Page 1 of 16 FOR USE WITH POOL AND SPA PRODUCTS WPC-1 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. ETL LISTED Conforms to UL STD 508; Certified to CSA STD C22.2 No. 14 4008814 79-15053-00 REV. D4 www.srsmith.com Page 2 of 16 The WPC-1 consists of the following parts: Item No. Qty. Component part No. Description 1 1 - WPC-1 Enclosure 2 1 94-15087-00 WPC-1 Enclosure Door 3 1 37-15000-00 Relay 4 1 41-15004-08 8 Position Terminal Block 5 1 42-15032-00 Timer 6 1 02-15268-00 Face Plate 7 2 02-15274-00 WPC-1 Mounting Bracket 8 1 41-15003-00 Grounding Bar 9 1 94-15255-00 WPC Receiver 10 6 10-15086-04 Face Plate and Mounting Bracket Screws 11 2 10-15089-06 Terminal Block Mounting Screw 12 2 10-15060-01 Relay Mounting Screw 13 8 10-15089-03 Timer and Receiver Mounting Screws 14 2 A11526 3-Position Toggle Switch 15 1 94-15257-00 WPC Repeater 16 2 10-15089-02 Freeze Device Mounting Screw (Optional equipment) 17 1 20-15013-00 Strain Relief 18 1 17-15005-00 Latch 19 2 10-15089-01 Latch Mounting Screws Accessory Items: FP 1/2 Temperature Freeze Device WE-65 65 ft Repeater Cord Extension Kit DL-HUB Direct Light Hub Connection Kit WPC-12V 12V Transformer for SR Smith Light Streams LED Products 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 16 17 18 19 79-15053-00 REV. D4 www.srsmith.com Page 3 of 16 Basic safety precautions should be observed when operating the WPC-1 product and other associated equipment. 1. A qualified electrician must install the WPC-1 in accordance to the National and Local Electrical Codes. 2. The WPC-1 must not be less then 5 feet (3 meters in Canada) from inside edge of pool. ONLY USE COPPER CONDUCTORS. 3. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors. 4. For the bonding, grounding, installing, and wiring of underwater lights to the WPC-1, refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code. 5. This device should never operate equipment that could cause property damage, bodily injury, or death should it be activated unexpectedly. 6. Never allow children to o perate the WPC-1 unsupervised. IMPORTANT SAFETY INFORMATION ELECTRICAL RATINGS Do not exceed the maximum electrical ratings of the WPC-1. A circuit breaker rated at 20Amps at 120VAC must be installed in the breaker panel to connect to the WPC-1 power input. Circuit 1 and Circuit 2 are each rated for use of up to 8Amps @ 120VAC. The Pump Relay is rated at a maximum of 3HP @ 240VAC. SAVE THESE INSTRUCTIONS! 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by SR Smith, LLC. could void the user's authorit y to operate the equipment. FCC WARNING 79-15053-00 REV. D4 www.srsmith.com Page 4 of 16 WARNING • TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT. • ALL INSTALLATION AND MAINTENANCE WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL PERSONEL ONLY. • VERIFY ALL ELECTRICAL RATINGS BEFORE INSTALLATION IS COMPLETE. FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL LOCAL REGULATORY REQUIREMENTS. WIRING INSTRUCTIONS LOCATION Install the WPC-1 enclosure using the mounting plates included with each enclosure. The WPC- 1 is housed in a Type 3R rainproof enclosure and can be mounted anywhere between the pool equipment and the breaker panel. Power Connections: To wire the WPC-1 use insulated COPPER wire only, 12 gauge minimum. Run a ½” to ¾” conduit from the main breaker panel to the WPC-1. Pull appropriate wires from the main breake r panel to the WPC-1 unit. To make power connections remove 3/8 inches of insulation from wire ends. Insert the bare end of wires under the pressure plate of terminals (Power Input, HOT). Use 1/8- in. flat head screwdriver to tighte n terminal screws firmly (4.4 lb-in minimum). Connect the house common to the Power Inputs NEUTRAL terminal. Connect another HOT wire to the Timeclocks T/C POWER terminal. Connect a house common to the Timeclocks T/C NEUTRAL. Install a 20 Amp circuit breaker in the main breake r panel and connect the HOT wires from the WPC-1. GROUND T/C POWER T/C NEUTRAL 120V INPUT NEUTRAL 120VAC 20AMP CIRCUIT BREAKER 79-15053-00 REV. D4 www.srsmith.com Page 5 of 16 Power Connection with GFCI To wire the WPC-1 with the use of a GFCI, punch out the GFCI knockout on the side of the WPC-1 enclosure. Install an outdoor rated GFCI. Using COPPER wire only, 12 gauge minimum, connect the GFCI from the LOAD side to the HOT terminal o n the POWER INPUT of the WPC-1. Connect the NEUTRAL from the LOAD side of the GFCI to the NEUTRAL terminal from the WPC-1. Connect the GROUND of the GFCI to the EQUIP. GND. bar. Wire the HOT from the GFCI’s LINE side to the 20Amp circuit breaker in the main breaker panel as discussed earlier. Connect the NEUTRAL from the GFCI’s LINE side to the house common. From the GFCI’s LINE side, connect a wire from the HOT to the Timeclocks T/C POWE R terminal. From the NEUTRAL of the LINE side on the GFCI, connect to the T/C NEUTRAL on the terminal block. NOTE: Do not connect the Timecloc k Inputs to the LOAD side of the GFCI. TO NEUTRAL BAR HOT LINE SIDE GROUND T/C NEUTRAL T/C POWER HOT LOAD SIDE NEUTRAL LOAD SIDE GFCI 120VAC 20AMP CIRCUIT BREAKER 79-15053-00 REV. D4 www.srsmith.com Page 6 of 16 Hooking up Lights to Circuit 1 and Circuit 2 To connect a lighting product to the Circuit 1 and Circuit 2 switch, pull wires from the products to the WPC-1 through conduits connected to the bottom of the WPC-1. As illustrated, connec t lights that will be operated by the Circuit 1 Switch to the Circuit 1 terminal. Connect the Neutral to the N…
Text truncated - open the document above for the full version.
Block Diagram RF Transmitter 915MHz Serial data Encoder HT12E Parallel data Serial data RF Receiver 915MHz Serial data Decoder MCU HT48R05A-1 Parallel data
1 1 2 2 3 3 4 4 DD CC BB AA Title NumberRevisionSize A4 Date:2014/12/10Sheet of File:D:\OHGA_P\..\Transmitter Block Diagram.SchDocDrawn By: 1 2 3 4 8 7 6 5 SW1 EAH104E Transmitter Block Diagram RM6000TX024 11 Cruise leng D1 LL4148 D2 LL4148 D3 LL4148 D4 LL4148 GND GND 1 2 3 4 5 JP1 CONNECT BAT 9VDC GND C12 0.1uF R8 1.2M, 1% GND POWER 2 ON/OFF POWER 1 ON/OFF SYNC ON/OFF WIRTRAN / WPC04MWPC1/ WPC2/ PT6000 POWER ON/OFF R7 10K C13 0.1uF VCC VCC Q1 MMBT3904 R9 2K LED1 RED GND VCC C9 47PF R5 56K L3 4.7nH C8 0.5pF Q4 BFR540 C10 9pF R6 330 ohm C7 10pF C6 1.5pF R3 47K R4 2.1k Q2 BFR540 Q3 MMBT3904 R2 22K R1 10K C5 1.5pF C4 1.8pF C11 nc C3 1pF C1 1nF C2 0.1uF L2 12nH L1 5.6nH GND GND GNDGND GND VCC NC 1 A0 2 A1 3 A2 4 A3 5 A4 6 A5 7 A6 8 A7 9 VSS 10 AD8 11 AD9 12 AD10 13 AD11 14 TE 15 OSC2 16 OSC1 17 DUNT 18 VDD 19 NC 20 IC1 HT-12ESOP TP1 TP2 TP3 TP4 D5 LL4148 D6 LL4148 GND ABC D E F Q5 TC0278A 915.00MHz GND 12Button-1 12Button-2 12 Button-3 (3 Buttom)(1 Buttom) Sixteen channel switching 9V battery Bottom input Designator File Name Encoder Serial data Trigger LED Serial data 915MHz saw filter Designator File Name First stage amplifier Serial data ON/OFF The second stage amplifier LC filter ANT 915MHz Serial data output
PO Box 400 | 1017 SW Berg Parkway | Canby, OR 97013 | Toll Free 800.824.4387 | Worldwide 503.266.2231 | Fax 503.266.4334 | www.srsmith.com 11/26/14 Dear Sir/Madam, Re: FCC Agent Authorization Letter We, S.R. Smith LLC, hereby authorize (Michael Gbadebo, P.E.) ITC Engineering Services Inc. - 9959 Calaveras Rd. Sunol, CA - to act as a Certification Body for certifying for the following project(s): Table info for 70-15286-xx Label, FCC logo, Tx LABEL P/N MODEL FCC ID NO. LOCATION 70-15286-05 WPC-1 2ABMM-WPCPT6WIR Centered on upper, back of remote 70-15286-06 WPC-2 2ABMM-WPCPT6WIR Centered on upper, back of remote 70-15286-07 PT-6000 2ABMM-WPCPT6WIR Centered on upper, back of remote 70-15286-08 WIR-TRAN 2ABMM-WPCPT6WIR Centered on upper, back of remote Table info for 70-15287-xx Label, FCC logo, Rx product PART NUMBER MODEL FCC Statement LOCATION 70-15287-05 WPC-1 Only use with WPC-1 Tx Inside door panel, bottom center 70-15287-06 WPC-2 Only use with WPC-2 Tx Inside door panel, bottom center 70-15287-07 PT-6000 Only use with PT-6000 Tx Under cover, top of chassis 70-15287-08 WIR-TRAN Only use with WIR-TRAN Tx Inside door panel, bottom center We affirm that between ITC Engineering Services Inc. and S.R. Smith LLC, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Scot Newport E-mail – [email protected] Scot Newport
External Photos 2- Channel WPC Transmitter 1- Channel WPC Transmitter WPC-1 Relay Controller and Repeater WPC-2 Relay Controller and Repeater WPC-3 Relay Controller and Repeater WPC-4 Relay Controller and Repeater
Label Location
SAMPLE LABEL FCC ID: 2ABMM-WPCPT6WIR
Internal Photos 2-Channel WPC Transmitter 1-Channel WPC Transmitter 2-Channel WPC Transmitter 1-Channel WPC Transmitter WPC- 1, Timer and Remote Control Switches WPC-2, Timer and Remote Control Switches WPC-3, Timers and Remote Switches WPC-4, Timer and Remote Control Switch
Antenna Description and Specs Transmitter Antenna Description : 1. On-board. 2. Size : Length is 80mm, width is 1.5mm, thick is 1oz. 3. Output Impedance : 50Ω 4. Frequency Range : 914.850- 915.150MHz. 5. Material : Copper 6. Antenna Gain : 0 dBm Receiver Antenna Description : 1. On-board. 2. Size : Length is 84mm, width is 1.5mm, thick is 1oz. 3. Output Impedance : 50Ω 4. Frequency Range : 914.850- 915.150MHz. 5. Material : Copper
Product (Each product comes with a matched Tx & Rx) Basic DescriptionSimilaritiesDifferencesFreq. Transmitter board equipped (part number is actually assembly with board, shell, button layout, and labels. -xx refers to the variations of the shell and label configuration. The actual Tx PCB is the same for all transmitters. WPC-1 seriesOutdoor, wall mounted control panel for basic pool pump control through a time clock and two, switched 110VAC lighting circuits. The lighting circuits are configured to be controlled by the RF remote control or on-board manual switches. Base 2-circuit configuration915MHz94-15253-xx WPC-2 seriesOutdoor mounted control panel for basic pool pump control through a time clock and two, switched 110VAC lighting circuits. The lighting circuits are configured to be controlled by the RF remote control or on-board manual switches. Same remote system and switch layout as WPC-1. Larger panel to include a 100A load center + breakers 915MHz94-15253-xx PT-6000Outdoor 'tower' style enclosure to house two, 30W transformers driven by two, 110VAC lighting circuits controlled by RF remote control or on-board manual switches Same RF system and switch layout as WPC-1 and WPC-2 series panels. No pool pump control. Tower style enclosure. 915MHz94-15253-xx WIR-TranOutdoor, wall mounted, Lighting control panel for one switched 110VAC lighting circuit driving one 12VAC transformer. The lighting circuits are configured to be controlled by the RF remote control or on-board manual switch. Own configurationSmaller enclosure and only utilizes channel 1 of 2 channel system. 915MHz 94-15253-xx (Channel 2 circuit is disabled by removing button and triggering circuit pathway from handheld remote. Board is still the same.) Product Table for Use with FCC ID# 2ABMM-WPCPT6WIR Technical Description
NOTES: UNLESS OTHERWISE SPECIFIED. 1. USE MANUFACTURER (LEI CHUANG COMPOUND CO., LTD) COLOR SYSTEM OR EQUIVALENT. 2. COLOR TO BE BLACK OR EQUIVALENT. 3. REMOTE CONTROL TO BE ASSEMBLED BY VENDOR USING STAINLESS STEEL SCREWS. 4. 9V BATTERY TO BE INCLUDED WITH EVERY REMOTE. 5. PCB MUST HAVE CONFORMAL COATING. 6. SECURELY AFFIX LABEL 70-15286-XX FOR APPROPRIATE PRODUCT (SEE CHART), TO ANY FREE SPACE ON REMOTE SURFACE MODEL XXX-X FCC ID: XXX-XXXX 6 6 SAMPLE IMAGE ONLY, SEE DRAWING 70-15286-XX ± ± .XX .XXX TRANSMITTER,WPC USED ON APPLICATION NEXT ASSY APPROVALS N/A DO NOT SCALE DRAWING MATERIAL: FINISH: N/A PURCHASING MGR: V.P. MFG: DIR. ENGR: SAFETY SPECIALIST: Q.C. MGR: UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MM. TOLERANCES ARE: MODIFIED BY: FRACTIONS ± DECIMALS PROJECT ENGR: DRAWN BY: ANGLES ± UL FILE NO.: B SCALE= SIZEDWG NO.: DATES REV. SHEET1 OF 4 THIRD ANGLE PROJECTION REV A RELEASE TO PRODUCTION. DESCRIPTIONZONEECO NO. 463_ DATE 5/18/06 APPROVED BS REVISIONS THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT PRIOR AUTHORIZATION OF S.R. SMITH, INC. A. KIM 09/23/05 94-15253-00 B 1:1 _ _ 1 - K.MARTIN5/12/14 8/1/07 JN 8/23/07 RB 8/23/07 HLS 8/23/07 CV 8/27/07 HS FRO DJ _ _ B 504 _ LOWERED POWER LEVEL OF TRANSMITTER UPDATED FCC ID INFO. 11/25/14BS TRANSMITTER,WPC MODIFIED BY: UL FILE NO.: B SCALE= SIZEDWG NO.:REV. SHEET2 OF 4 94-15253-00 B NTS - K.MARTIN5/12/14 TRANSMITTER,WPC MODIFIED BY: UL FILE NO.: B SCALE= SIZEDWG NO.:REV. SHEET3 OF 4 94-15253-00 B NTS - K.MARTIN5/12/14 ITEMALT.ITEM DESCRIPTIONMFGMFG P/NQTY REF DESIGNATOR 0001 DIP SW., LOW PROFILE ACTUATOR, 4PST TOP 百容EAH104EZ 1 SW1 0002BATTERY., 9V P/N: BS-IC 常利BS-IC1 BAT 0003LED.,3mm RND, BRIGHT RED DIFF,EVERLIGHTEL-204HD 1 LED1 0004 PIN HEADER.,5PIN 1*5 P/N:PHSR05G10 GTKPHSR05G101 JP1 0005 PCB RM6000TX-024 2層板無鉛噴錫1 0006(S)CAP., 0.1UF/50V/X7R/K 0603MURATAGRM188R71H104KA93D3 C12,C13,C2 0006(M)CAP., 0.1UF/50V/X7R/K 0603TDKC1608X7R1H104KT3 C12,C13,C2 0007CAP.1.8PF/50V/COG/C 0603TDKC1608C0G1H1R8CT1 C4 0008(S)CAP., 1000PF/50V/NPO/J 0603MURATAGRM1885C1H102JA01D1 C1 0008(M)CAP., 1000PF/50V/NPO/J 0603TDKC1608COG1H102JT 1 C1 0009(S)RES. 1% 2.1K 0603 ,CHIPPHYCOMP2322 704 62102L1 R4 0009(S)RES. 1% 2.1K 0603 ,CHIPVIKINGCR-03FL7---2K11 R4 0009(M)RES. 1% 2.1K 0603 ,CHIPWALSINWR06X2101FTL1 R4 0009(S)RES. 1% 2.1K 0603 ,CHIPYAGEORC0603FR-O72K1L1 R4 0010(M)CAP. .1PF /50V/NOP/C/0603TDKC1608C0G1H010CT1 C3 0010(S)CAP. .1PF /50V/NOP/C/0603MURATA'GRM1885C1H1R0CA01D1 C3 0011(S)CAP., 47PF/50V/NPO/J 0603MURATAGRM1885C1H470JA01D1 C9 0011(M)CAP., 47PF/50V/NPO/J 0603TDKC1608COG1H470JT1 C9 0012(S)CAP. 1.5PF/50V/NPO/C 0603MURATAGRM1885C1H1R5CA01D2 C5,C6 0012(M)CAP. 1.5PF/50V/NPO/C 0603TDKC1608COG1H1R5C2 C5,C6 0013IC., 20 PIN, P/N:HT12E-2 20SOPHOLTEKHT12E-2 1 IC1 0014(S)RES. 5% 10K 0603,CHIPYAGEORC0603JR-0710KL2 R7,R1 0014(S)RES. 5% 10K 0603,CHIPVIKINGCR-03JL7---10K2 R7,R1 0014(M)RES. 5% 10K 0603,CHIPWALSINWR06X103JTL2 R7,R1 0018(M)RES. 5% 2K 0603 ,CHIPWALSINWR06X202JTL1 R9 0018(S)RES. 5% 2K 0603 ,CHIPYAGEORC0603JR-072KL1 R9 0018(S)RES. 5% 2K 0603 ,CHIPVIKINGCR-03JL7----2K1 R9 0019(M)RES. 1% 1.2M 0603,CHIPWALSINWR06X1204FTL (1 R8 0019(S)RES. 1% 1.2M 0603,CHIPYAGEORC0603FR-071M2L 1 R8 0019(S)RES. 1% 1.2M 0603,CHIPVIKINGCR-03FL7---1M2 1 R8 0020(S)RES. 5% 47K 0603 ,CHIPYAGEORC0603JR-0747KL1 R3 0020(M)RES. 5% 47K 0603 ,CHIPWALSINWR06X473JTL1 R3 0020(S)RES. 5% 47K 0603 ,CHIPVIKINGCR-03JL7---47K1 R3 0021(S)RES. 5% 56K 0603 ,CHIPYAGEORC0603JR-0756KL1 R5 ITEMALT.ITEM DESCRIPTIONMFGMFG P/NQTY REF DESIGNATOR 0021(S)RES. 5% 56K 0603 ,CHIPVIKINGCR-03JL7---56K1 R5 0021(M)RES. 5% 56K 0603 ,CHIPWALSINWR06X563JTL1 R5 0022(S)RES. 5% 330E 0603,CHIPYAGEORC0603JR-07330RL1 R6 0022(M)RES. 5% 330E 0603,CHIPWALSINWR06X331JTL1 R6 0022(S)RES. 5% 330E 0603,CHIPVIKINGCR-03JL7--330R1 R6 0023(S)RES. 5% 22K 0603 ,CHIPYAGEORC0603JR-0722KL1 R2 0023(S)RES. 5% 22K 0603 ,CHIPVIKINGCR-03JL7---22K1 R2 0023(M)RES. 5% 22K 0603 ,CHIPWALSINWR06X223JTL1 R2 0024(M) TRANSISTOR., P/N:MMBT3904-7-F (DIODES) DIDOESMMBT3904-7-F 2 Q1,Q3 0024(S) TRANSISTOR SOT-23 P/N:MMBT3904LT1G (ON) ONMMBT3904LT1G2 Q1,Q3 0024(S) TRANSISTOR., P/N:MMBT3904LT1G (WILLAS) WILLASMMBT3904LT1G2 Q1,Q3 0024(S) TRANSISTOR., P/N:MMBT3904-TP (MICRO) MICRO COMMERCIAL MMBT3904-TP2 Q1,Q3 0025 TRANS NPN 120MA 15V 9GHZ SOT23 NXPBFR540,2152 Q2,Q4 0026(S) DIODE.,75V/500mW, P/N:LL4148 (PANJIT) MI PANJITLL41484 D1-D4 0026(M) DIODE.,75V/500mW, P/N:LL4148 (DACO) DACOLL41484 D1-D4 0026(S) DIODE.,75V/500mW, P/N:LL4148-13 (DIODES) DIODESLL4148-134 D1-D4 0026(S) DIODE.,75V/500mW, P/N:LL4148 (GD) GDLL41484 D1-D4 0026(S) DIODE.,75V/500mW, P/N:LL4148-GS (VISHAY) VISHAYLL4148-GS184 D1-D4 0027IND.,5%,12nH, 0603, CHIP (TDK)TDKMLG1608B12NJ1 L2 0028IND.,0.5%,5.6nH, 0603, CHIP (TDK)TDKMLG1608B5N6D1 L1 0029(S)CAP. 9PF/50V/NPO/C 0603TDKC1608C0G1H090C080AA 1 C10 0029(M)CAP. 9PF/50V/NPO/D 0603TDKC1608C0G1H090D080AA1 C10 0030 SAW Resonator., 915.00 MHz, (TC0278A) TAI SAWW915.00TC0278A1 Q5 0031IND.±0.3nH,4.7nH, 0603, CHIPTDKMLG1608B4N7S1 L3 0032CAP., 10PF/50V/NPO/C, 0603TDKC1608COG1H100CT1 C7 0033CAP. 0.5PF/50V/NPO/C 0603TDKC1608COG1H0R5C1 C8 TRANSMITTER,WPC MODIFIED BY: UL FILE NO.: B SCALE= SIZEDWG NO.:REV. SHEET4 OF 4 94-15253-00 B NTS K.MARTIN5/12/14
NOTES: UNLESS OTHERWISE SPECIFIED. 1. USE MANUFACTURER (LEI CHUANG COMPOUND CO., LTD) COLOR SYSTEM OR EQUIVALENT. 2. COLOR TO BE YELLOW 91202 OR EQUIVALENT. 3. REMOTE CONTROL TO BE ASSEMBLED BY VENDOR USING STAINLESS STEEL SCREWS. 4. 9V BATTERY TO BE INCLUDED WITH EVERY REMOTE. 5. PCB MUST HAVE CONFORMAL COATING. 6. SECURELY AFFIX LABEL 70-15286-08 TO ANY FREE SPACE ON REMOTE SURFACE. MODEL WIR-TRAN FCC ID: 2ABMM-WIRTRANT 6 6 SAMPLE IMAGE ONLY, SEE DRAWING 70-15286-XX ± ± .XX .XXX TRANSMITTER, 915 MHZ, 1-CIRCUIT USED ON APPLICATION NEXT ASSY APPROVALS N/A DO NOT SCALE DRAWING MATERIAL: FINISH: N/A PURCHASING MGR: V.P. MFG: DIR. ENGR: SAFETY SPECIALIST: Q.C. MGR: UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MM. TOLERANCES ARE: MODIFIED BY: FRACTIONS ± DECIMALS PROJECT ENGR: DRAWN BY: ANGLES ± UL FILE NO.: B SCALE= SIZEDWG NO.: DATES REV. SHEET1 OF 4 THIRD ANGLE PROJECTION REV A RELEASE TO PRODUCTION DESCRIPTIONZONEECO NO. 463 _ DATE 5/7/14 APPROVED BS REVISIONS THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT PRIOR AUTHORIZATION OF S.R. SMITH, INC. A. KIM 09/23/05 94-15254-00 B NTS _ _ 1 - K.MARTIN5/7/14 8/01/07 JN 8/23/07 RB 8/23/07 HLS 8/23/07 CV 8/27/07 HS FOR DJ _ _ BS11/25/14 LOWERED POWER LEVEL OF TRANSMITTER UPDATED FCC ID INFO. _ 504B TRANSMITTER, 915 MHZ, 1-CIRCUIT MODIFIED BY: UL FILE NO.: B SCALE= SIZEDWG NO.:REV. SHEET2 OF 4 94-15254-00 B 1:1 - H.STAMPER7/12/07 TRANSMITTER, 915 MHZ, 1-CIRCUIT MODIFIED BY: UL FILE NO.: B SCALE= SIZEDWG NO.:REV. SHEET3 OF 4 94-15254-00 B NTS - K.MARTIN5/7/14 ITEMITEM DESCRIPTIONALT.MFGMFG P/NQTYREF DESIGNATOR 0024 TRANSISTOR., P/N:MMBT3904-7- F (DIODES) (M)DIDOESMMBT3904-7-F 2 Q1,Q3 0024 TRANSISTOR SOT-23 P/N:MMBT3904LT1G (ON) (S)ONMMBT3904LT1G2 Q1,Q3 0024 TRANSISTOR., P/N:MMBT3904LT1G (WILLAS) (S)WILLASMMBT3904LT1G2 Q1,Q3 0024 TRANSISTOR., P/N:MMBT3904-TP (MICRO) (S) MICRO COMMERCIAL MMBT3904-TP2 Q1,Q3 0025 TRANS NPN 120MA 15V 9GHZ SOT23 NXPBFR540,2152 Q2,Q4 0026 DIODE.,75V/500mW, P/N:LL4148 (PANJIT) MI (S)PANJITLL41484 D1-D4 0026 DIODE.,75V/500mW, P/N:LL4148 (DACO) (M)DACOLL41484 D1-D4 0026 DIODE.,75V/500mW, P/N:LL4148-13 (DIODES) (S)DIODESLL4148-134 D1-D4 0026 DIODE.,75V/500mW, P/N:LL4148 (GD) (S)GDLL41484 D1-D4 0026 DIODE.,75V/500mW, P/N:LL4148-GS (VISHAY) (S)VISHAYLL4148-GS184 D1-D4 0027IND.,5%,12nH, 0603, CHIP (TDK)TDKMLG1608B12NJ1 L2 0028 IND.,0.5%,5.6nH, 0603, CHIP (TDK) TDKMLG1608B5N6D1 L1 0029CAP. 9PF/50V/NPO/C 0603(S)TDK C1608C0G1H090C 080AA 1 C10 0029CAP. 9PF/50V/NPO/D 0603(M)TDK C1608C0G1H090D 080AA 1 C10 0030 SAW Resonator., 915.00 MHz, (TC0278A) TAI SAWW915.00TC0278A1 Q5 0031IND.±0.3nH,4.7nH, 0603, CHIPTDKMLG1608B4N7S1 L3 0032CAP., 10PF/50V/NPO/C, 0603TDK C1608COG1H100C T 1 C7 0033CAP. 0.5PF/50V/NPO/C 0603TDKC1608COG1H0R5C1 C8 ITEMALT.ITEM DESCRIPTIONMFGMFG P/NQTY REF DESIGNATO R 0001 DIP SW., LOW PROFILE ACTUATOR, 4PST TOP 百容EAH104EZ 1 SW1 0002BATTERY., 9V P/N: BS-IC 常利BS-IC1 BAT 0003LED.,3mm RND, BRIGHT RED DIFF, EVERLIGH T EL-204HD 1 LED1 0004PIN HEADER.,5PIN 1*5 P/N:PHSR05G10GTKPHSR05G101 JP1 0005 PCB RM6000TX-024 2層板無鉛噴錫1 0006(S)CAP., 0.1UF/50V/X7R/K 0603MURATAGRM188R71H104KA93D3 C12,C13,C2 0006(M)CAP., 0.1UF/50V/X7R/K 0603TDKC1608X7R1H104KT3 C12,C13,C2 0007CAP.1.8PF/50V/COG/C 0603TDKC1608C0G1H1R8CT1 C4 0008(S)CAP., 1000PF/50V/NPO/J 0603MURATAGRM1885C1H102JA01D1 C1 0008(M)CAP., 1000PF/50V/NPO/J 0603TDKC1608COG1H102JT 1 C1 0009(S)RES. 1% 2.1K 0603 ,CHIP PHYCOM P 2322 704 62102L1 R4 0009(S)RES. 1% 2.1K 0603 ,CHIPVIKINGCR-03FL7---2K11 R4 0009(M)RES. 1% 2.1K 0603 ,CHIPWALSINWR06X2101FTL1 R4 0009(S)RES. 1% 2.1K 0603 ,CHIPYAGEORC0603FR-O72K1L1 R4 0010(M)CAP. .1PF /50V/NOP/C/0603TDKC1608C0G1H010CT1 C3 0010(S)CAP. .1PF /50V/NOP/C/0603MURATA' GRM1885C1H1R0CA01 D 1 C3 0011(S)CAP., 47PF/50V/NPO/J 0603MURATAGRM1885C1H470JA01D1 C9 0011(M)CAP., 47PF/50V/NPO/J 0603TDKC1608COG1H470JT1 C9 0012(S)CAP. 1.5PF/50V/NPO/C 0603MURATA GRM1885C1H1R5CA01 D 2 C5,C6 0012(M)CAP. 1.5PF/50V/NPO/C 0603TDKC1608COG1H1R5C2 C5,C6 0013IC., 20 PIN, P/N:HT12E-2 20SOPHOLTEKHT12E-2 1 IC1 0014(S)RES. 5% 10K 0603,CHIPYAGEORC0603JR-0710KL2 R7,R1 0014(S)RES. 5% 10K 0603,CHIPVIKINGCR-03JL7---10K2 R7,R1 0014(M)RES. 5% 10K 0603,CHIPWALSINWR06X103JTL2 R7,R1 0018(M)RES. 5% 2K 0603 ,CHIPWALSINWR06X202JTL1 R9 0018(S)RES. 5% 2K 0603 ,CHIPYAGEORC0603JR-072KL1 R9 0018(S)RES. 5% 2K 0603 ,CHIPVIKINGCR-03JL7----2K1 R9 0019(M)RES. 1% 1.2M 0603,CHIPWALSINWR06X1204FTL (1 R8 0019(S)RES. 1% 1.2M 0603,CHIPYAGEORC0603FR-071M2L 1 R8 0019(S)RES. 1% 1.2M 0603,CHIPVIKINGCR-03FL7---1M2 1 R8 0020(S)RES. 5% 47K 0603 ,CHIPYAGEORC0603JR-0747KL1 R3 0020(M)RES. 5% 47K 0603 ,CHIPWALSINWR06X473JTL1 R3 0020(S)RES. 5% 47K 0603 ,CHIPVIKINGCR-03JL7---47K1 R3 0021(S)RES. 5% 56K 0603 ,CHIPYAGEORC0603JR-0756KL1 R5 0021(S)RES. 5% 56K 0603 ,CHIPVIKINGCR-03JL7---56K1 R5 0021(M)RES. 5% 56K 0603 ,CHIPWALSINWR06X563JTL1 R5 0022(S)RES. 5% 330E 0603,CHIPYAGEORC0603JR-07330RL1 R6 0022(M)RES. 5% 330E 0603,CHIPWALSINWR06X331JTL1 R6 0022(S)RES. 5% 330E 0603,CHIPVIKINGCR-03JL7--330R1 R6 0023(S)RES. 5% 22K 0603 ,CHIPYAGEORC0603JR-0722KL1 R2 0023(S)RES. 5% 22K 0603 ,CHIPVIKINGCR-03JL7---22K1 R2 0023(M)RES. 5% 22K 0603 ,CHIPWALSINWR06X223JTL1 R2 TRANSMITTER, 915 MHZ, 1-CIRCUIT MODIFIED BY: UL FILE NO.: B SCALE= SIZEDWG NO.:REV. SHEET4 OF 4 94-15254-00 B NTS K.MARTIN5/7/14
1 1 2 2 3 3 4 4 DD CC BB AA Title NumberRevisionSize A4 Date:2014/9/4Sheet of File:D:\OHGA_P\..\RM6000TX-024-RF IN PCB.SchDocDrawn By: 1 2 3 4 8 7 6 5 SW1 EAH104E WIRTRAN & WPC1/WPC2/PT6000 - 915MHz RM6000TX024 11 Cruise leng D1 LL4148 D2 LL4148 D3 LL4148 D4 LL4148 GND GND 1 2 3 4 5 JP1 CONNECT BAT 9VDC GND C12 0.1uF R8 1.2M, 1% GND POWER 2 POWER 1 SYNC ON/OFF NO USE PT6000 WPC04M NO USE NO USE NO USE POWER ON/OFF R7 10K C13 0.1uF VCC VCC GNDDATAVCCANT 1 ANT Q1 MMBT3904 R9 2K LED1 RED GND VCC C9 47PF R5 56K L3 4.7nH C8 0.5pF Q4 BFR540 C10 9pF R6 330 ohm C7 10pF C6 3.3pF R3 47K R4 330 ohm Q2 BFR540 Q3 MMBT3904 R2 22K R1 10K C5 1.5pF C4 1.8pF C11 nc C3 1pF C1 1nF C2 10nF L2 12nH L1 5.6nH GND GND GNDGND GND 1 2 3 4 JP2 CON4 GND GND DATA VCC ANT VCC DATA DATA NC 1 A0 2 A1 3 A2 4 A3 5 A4 6 A5 7 A6 8 A7 9 VSS 10 AD8 11 AD9 12 AD10 13 AD11 14 TE 15 OSC2 16 OSC1 17 DUNT 18 VDD 19 NC 20 IC1 HT-12ESOP TP1 TP2 TP3 TP4 D5 LL4148 D6 LL4148 GND R10 nc PCB ANT ABC D E F Q5 TC0278A 915.00MHz GND 4 3 2 1
Test Report issued under the responsibility of: ITC ENGINEERING SERVICES, INC. FCC Part 15.249 Test Report Report Reference No. ............... : 20141009-01-WPC-RF Date of Issue ................................ : December 17, 2014 Total Number of Pages ................ : 15 Testing Laboratory .................... : ITC Engineering Services, Inc. Address ........................................ : 9959 Calaveras Road, Box 543, Sunol CA 94586 Applicant’s Name ..................... : S.R. Smith Address ........................................ : 1017 SW Berg Parkway, Canby, OR 97013 Contact ........................................ : Mr. Jonathan Quon Phone ........................................... : 925-463-5520 Test Specification Standard ....... : FCC Part 15.209; and, FCC Part 15.249 Test Procedure............................. : Emissions Judgment ..................................... : Complies as Tested Manufacturer Logo ...................... : Manufacturer............................... : S.R. Smith Model/Type Reference ................ : Wireless Controller Tx for use with: WPC-1, WPC-2, PT-6000, & WIR-TRAN Input Voltage Rating .................... : 9Vdc ISO/IEC 17025:2005 Accredited Laboratory Applicant: S.R. Smith Report Number: 20141009-01-WPC-RF Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: [email protected] Web: www.itcemc.com Page 2 of 15 Product: Wireless Pool Controller Tx, for Models: WPC-1, WPC-2, PT-6000, WIR-TRAN Table of Contents TABLE OF CONTENTS ............................................................................................................................................................................... 2 TABLE OF FIGURES .................................................................................................................................................................................. 2 1 DOCUMENTATION ......................................................................................................................................................... 3 1.1 G ENERAL INFORMATION .......................................................................................................................................................................... 3 1.2 S UMMARY OF TEST ................................................................................................................................................................................. 3 1.2.1 Emissions Test Methods: ........................................................................................................................................................ 3 1.3 DECLARATION/DISCLAIMER ...................................................................................................................................................................... 4 1.4 EUT PORTS AND CONNECTORS ................................................................................................................................................................. 4 1.5 EUT DESCRIPTION .................................................................................................................................................................................. 4 1.6 L IST OF PERIPHERALS USED DURING TEST .................................................................................................................................................... 4 1.7 G ENERAL TEST REMARKS ......................................................................................................................................................................... 4 1.7.1 The requirements according to the technical regulations are: ............................................................................................... 5 1.7.2 Administrative and Environmental Details ............................................................................................................................. 5 1.7.3 Test Equipment ....................................................................................................................................................................... 5 1.8 SPURIOUS AND CARRIER RADIATED EMISSIONS PER 47CFR15.249 FROM TRANSMITTER ....................................................................................... 5 1.8.1 Test Description ...................................................................................................................................................................... 5 1.8.2 Test Data ................................................................................................................................................................................ 6 1.8.3 Test Setup Photos ................................................................................................................................................................... 9 1.9 O PERATING FREQUENCY PER 47CFR15.249C ............................................................................................................................................ 10 1.9.1 Test Description .................................................................................................................................................................... 10 1.9.2 Administrative and Environmental Details ........................................................................................................................... 10 1.9.3 Test Data .............................................................................................................................................................................. 10 2 EUT TECHNICAL SPECIFICATION ................................................................................................................................... 11 2.1.1 EUT Photos .....................................................................................…
Text truncated - open the document above for the full version.
Test Setup Photos Radiated Emissions Setup, 30-200 MHz Radiated Emissions Setup, 200-1000 MHz Radiated Emissions Setup, 1GHz - 10GHz Operating Frequency per 47CFR15.249c Test Setup WPC Conducted Emissions Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 914.85 MHz - 915.15 MHz | - |

Control Box
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
RF Remoter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter