
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
I I n n s s t t r r u u c c t t i i o o n n M M a a n n u u a a l l Automatic Wrist Blood Pressure Monitor M M o o d d e e l l N N o o . . H H L L 1 1 5 5 8 8 H H D D 1 Table of Contents Medical Disclaimer.......................................................................................03 Intended Use...............................................................................................03 About Blood Pressure.................................................................................04 Measurement Method........................................................................06 Accuracy........................................................................................................ 06 Precautions....................................................................................................07 Device Overview...........................................................................................09 Symbol Definitions.....................................................................................11 Features.......................................................................................................12 Installing Batteries.....................................................................................16 Applying the Cuff........................................................................................17 Positioning Guide.........................................................................................18 Measurement Procedure..........................................................................19 Bluetooth Transmission..............................................................................21 Memory Function........................................................................................22 Storage and Maintenance.........................................................................23 Troubleshooting...........................................................................................24 Warranty & Recalibration............................................................................25 Specifications..............................................................................................26 Note..............................................................................................................28 Appendix........................................................................................................29 Blood Pressure Diary.................................................................................31 2 Medical Disclaimer This manual and product are not meant as a substitute for advice provided by your doctor. You are not to use the information contained herein, or this product for diagnosing or treating a health problem or prescribing any medication. If you have or suspect that you have a medical problem, promptly consult your healthcare provider. Intended Use This device uses the oscillometric method to automatically measure systolic and diastolic blood pressure as well as heart rate. The measurement position is at human being’s wrist. All values can be read out in one LCD panel. The device is designed for home use and recommended for use by adults aged 18 years and older with wrist circumference ranging 135 ~ 195 mm (approx. 5.3 ~ 7.7 inch). 3 About Blood Pressure 1. What is blood pressure? Blood pressure is the measurement of the force of blood pushing against the walls of the arteries. Arterial blood pressure is constantly fluctuating during the course of the cardiac cycle. The highest pressure in the cycle is called the systolic blood pressure, and represents the pressure in the artery when the heart is beating. The lowest pressure is the diastolic blood pressure, and represents the pressure in the artery when the heart is at rest. Both the systolic and the diastolic pressure are necessary for a physician to evaluate the status of a patient's blood pressure. Many factors such as physical activity, anxiety or the time of day, can influence your blood pressure. Blood pressure is typically low in the mornings and increases from the afternoon to the evening. It is on average lower in the summer and higher in the winter. 2. Why is it useful to measure blood pressure at home? Having one's blood pressure measured by a doctor in a hospital or a clinic, is often associated with a phenomenon called “White Coat Hypertension” where the patient becomes nervous or anxious, thus raising his blood pressure. There are also numerous other factors that might cause your blood pressure to be raised at a specific time of day. This is why medical practitioners recommend home monitoring as it is important to get readings of blood pressure during different times of the day to really get an idea of your real blood pressure. Medical practitioners generally recommend the “Rule of 3”, where you are encouraged to take your blood pressure three times in a row (at 3 ~ 5 minute interval), three times a day for three days. After three days you can average all the results and this will give you an accurate idea of what your blood pressure really is. 4 About Blood Pressure A. WHO blood pressure classifications: Standards for assessment of high or low blood pressure without regard to age, have been established by the World Health Organization (WHO), as shown in the chart. However this chart is not exact for classification of blood pressure and it's intended to be used as a guide in understanding non-invasive blood pressure measurements. Please consult with your physician for proper diagnosis. B. Variations in blood pressure: Individual blood pressures vary greatly both on a daily and a seasonal basis. These variations are even more pronounced in hyper tense patients. Normally the blood pressure rises while at work and is at its lowest during sleeping period. (hyper tense: means a person who has high blood pressure symptom.) The graph below illustrated the variations in blood pressure over a whole day with measurem…
Text truncated - open the document above for the full version.
Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD EUT External Photos Figure 1 General Appearance (Front and Side View) Figure 2 General Appearance (Back and Side View)
Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD EUT External Photos Figure 1 General Appearance (Front and Side View) Figure 2 General Appearance (Back and Side View)
Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD FCC ID Label Location z Label Placement Location z FCC ID Label Format FCC ID Label Placement Location
Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD FCC ID Label Location z Label Placement Location z FCC ID Label Format FCC ID Label Placement Location
Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD EUT Internal Photos Figure 3 Internal View (Removed Battery Cover) Figure 4 Internal View (Removed Cover, LCD Panel/Front View) Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD Figure 5 Internal View (Removed LCD Panel, LCD Panel/Back View) Figure 6 Internal View (Main Board, Front View) Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD Figure 7 Internal View (Main Board, Back View) Figure 8 Internal View (BLE Module, Front View) Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD Figure 9 Internal View (BLE Module, Back View) Figure 10 Internal View
Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD EUT Internal Photos Figure 3 Internal View (Removed Battery Cover) Figure 4 Internal View (Removed Cover, LCD Panel/Front View) Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD Figure 5 Internal View (Removed LCD Panel, LCD Panel/Back View) Figure 6 Internal View (Main Board, Front View) Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD Figure 7 Internal View (Main Board, Back View) Figure 8 Internal View (BLE Module, Front View) Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor FCC ID. : 2ABTAHNL15HD Figure 9 Internal View (BLE Module, Back View) Figure 10 Internal View
Maximum Permissive Exposure FCC ID: 2ABTAHNL15HD Product Name: Automatic Wrist Blood Pressure Monitor Model No: HL158HD We hereby that HL158HD is satisfying with SAR exclusion requirement for This application FCC ID: 2ABTAHNL15HD has the most closely distance from antenna to user is 26 mm and the max output power presented as following table. Max Output Power(dBm) Max Output Power(W) Exclusion threshold Level Calculation note1 Exclusion threshold Requirement 6.394 6.394 0.062 ≤ 3.0 Note 1: Pursuant to KDB 447498 D01 v05r02 that following equation is implemented to determine a threshold level. Equation: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 Thus exclusion threshold is (2.514 mW/26 mm)*√2.402=0.062 < 3.0. Sincerely Yours, ____________________________________ Mr. Ben Cheng Manager AUDIX Technology Corporation 26 mm
Maximum Permissive Exposure FCC ID: 2ABTAHNL15HD Product Name: Automatic Wrist Blood Pressure Monitor Model No: HL158HD We hereby that HL158HD is satisfying with SAR exclusion requirement for This application FCC ID: 2ABTAHNL15HD has the most closely distance from antenna to user is 26 mm and the max output power presented as following table. Max Output Power(dBm) Max Output Power(W) Exclusion threshold Level Calculation note1 Exclusion threshold Requirement 6.394 6.394 0.062 ≤ 3.0 Note 1: Pursuant to KDB 447498 D01 v05r02 that following equation is implemented to determine a threshold level. Equation: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 Thus exclusion threshold is (2.514 mW/26 mm)*√2.402=0.062 < 3.0. Sincerely Yours, ____________________________________ Mr. Ben Cheng Manager AUDIX Technology Corporation 26 mm
FCC ID: 2ABTAHNL15HD Page 1 of 51 AUDIX Technology Corporation Report No. EM-F150003 APPLICATION FOR CERTIFICATION On Behalf of Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor Model No.: HL158HD FCC ID: 2ABTAHNL15HD Prepared for : Health & Life Co., Ltd. 9F, No.186, Jian Yi Road, Zhonghe District, New Taipei City, Taiwan Prepared by : AUDIX Technology Corporation EMC Department No. 53-11, Dingfu, Linkou Dist., New Taipei City 244, Taiwan Tel : (02) 2609-9301, 2609-2133 Fax: (02) 2609-9303 File Number : C1M1412156 Report Number : EM-F150003 Date of Test : 2014. 12. 16 ~ 31 Date of Report : 2015. 01. 05 FCC ID: 2ABTAHNL15HD Page 2 of 51 AUDIX Technology Corporation Report No. EM-F150003 TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION ..............................................................................................4 1. DESCRIPTION OF REVISION HISTORY ........................................................................... 5 2. GENERAL INFORMATION .................................................................................................. 6 2.1. Description of Device (EUT) ........................................................................................................... 6 2.2. Description of Test Facility ............................................................................................................. 7 2.3. Measurement Uncertainty ................................................................................................................ 7 3. CONDUCTED EMISSION MEASUREMENT ..................................................................... 8 4. RADIATED EMISSION MEASUREMENT ......................................................................... 9 4.1. Test Equipment ................................................................................................................................ 9 4.2. Test Setup ........................................................................................................................................ 9 4.3. Radiated Emission Limits (§15.209) ............................................................................................. 11 4.4. Operating Condition of EUT ......................................................................................................... 11 4.5. Test Procedure ............................................................................................................................... 12 4.6. Test Results .................................................................................................................................... 13 5. DUTY CYCLE CORRECTION FACTOR .......................................................................... 25 5.1. Test Equipment .............................................................................................................................. 25 5.2. Test Setup ...................................................................................................................................... 25 5.3. Test Results .................................................................................................................................... 25 6. 6dB BANDWIDTH MEASUREMENT ................................................................................ 27 6.1. Test Equipment .............................................................................................................................. 27 6.2. Block Diagram of Test Setup......................................................................................................... 27 6.3. Specification Limits [§15.247(a)(2)] ............................................................................................. 27 6.4. Operating Condition of EUT ......................................................................................................... 27 6.5. Test Procedure ............................................................................................................................... 27 6.6. Test Results .................................................................................................................................... 28 7. MAXIMUM PEAK OUTPUT POWER MEASUREMENT .............................................. 31 7.1. Test Equipment .............................................................................................................................. 31 7.2. Block Diagram of Test Setup......................................................................................................... 31 7.3. Specification Limits [§15.247(b)-(3)] ............................................................................................ 31 7.4. Operating Condition of EUT ......................................................................................................... 31 7.5. Test Procedure ............................................................................................................................... 31 7.6. Test Results .................................................................................................................................... 31 8. EMISSION LIMITATIONS MEASUREMENT ................................................................. 34 8.1. Test Equipment .............................................................................................................................. 34 8.2. Block Diagram of Test Setup......................................................................................................... 34 8.3. Specification Limits (§15.247(c)) .................................................................................................. 34 8.4. Operating Condition of EUT ......................................................................................................... 34 8.5. Test Procedure ............................................................................................................................... 34 8.6. Te…
Text truncated - open the document above for the full version.
FCC ID: 2ABTAHNL15HD Page 1 of 51 AUDIX Technology Corporation Report No. EM-F150003 APPLICATION FOR CERTIFICATION On Behalf of Health & Life Co., Ltd. Automatic Wrist Blood Pressure Monitor Model No.: HL158HD FCC ID: 2ABTAHNL15HD Prepared for : Health & Life Co., Ltd. 9F, No.186, Jian Yi Road, Zhonghe District, New Taipei City, Taiwan Prepared by : AUDIX Technology Corporation EMC Department No. 53-11, Dingfu, Linkou Dist., New Taipei City 244, Taiwan Tel : (02) 2609-9301, 2609-2133 Fax: (02) 2609-9303 File Number : C1M1412156 Report Number : EM-F150003 Date of Test : 2014. 12. 16 ~ 31 Date of Report : 2015. 01. 05 FCC ID: 2ABTAHNL15HD Page 2 of 51 AUDIX Technology Corporation Report No. EM-F150003 TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION ..............................................................................................4 1. DESCRIPTION OF REVISION HISTORY ........................................................................... 5 2. GENERAL INFORMATION .................................................................................................. 6 2.1. Description of Device (EUT) ........................................................................................................... 6 2.2. Description of Test Facility ............................................................................................................. 7 2.3. Measurement Uncertainty ................................................................................................................ 7 3. CONDUCTED EMISSION MEASUREMENT ..................................................................... 8 4. RADIATED EMISSION MEASUREMENT ......................................................................... 9 4.1. Test Equipment ................................................................................................................................ 9 4.2. Test Setup ........................................................................................................................................ 9 4.3. Radiated Emission Limits (§15.209) ............................................................................................. 11 4.4. Operating Condition of EUT ......................................................................................................... 11 4.5. Test Procedure ............................................................................................................................... 12 4.6. Test Results .................................................................................................................................... 13 5. DUTY CYCLE CORRECTION FACTOR .......................................................................... 25 5.1. Test Equipment .............................................................................................................................. 25 5.2. Test Setup ...................................................................................................................................... 25 5.3. Test Results .................................................................................................................................... 25 6. 6dB BANDWIDTH MEASUREMENT ................................................................................ 27 6.1. Test Equipment .............................................................................................................................. 27 6.2. Block Diagram of Test Setup......................................................................................................... 27 6.3. Specification Limits [§15.247(a)(2)] ............................................................................................. 27 6.4. Operating Condition of EUT ......................................................................................................... 27 6.5. Test Procedure ............................................................................................................................... 27 6.6. Test Results .................................................................................................................................... 28 7. MAXIMUM PEAK OUTPUT POWER MEASUREMENT .............................................. 31 7.1. Test Equipment .............................................................................................................................. 31 7.2. Block Diagram of Test Setup......................................................................................................... 31 7.3. Specification Limits [§15.247(b)-(3)] ............................................................................................ 31 7.4. Operating Condition of EUT ......................................................................................................... 31 7.5. Test Procedure ............................................................................................................................... 31 7.6. Test Results .................................................................................................................................... 31 8. EMISSION LIMITATIONS MEASUREMENT ................................................................. 34 8.1. Test Equipment .............................................................................................................................. 34 8.2. Block Diagram of Test Setup......................................................................................................... 34 8.3. Specification Limits (§15.247(c)) .................................................................................................. 34 8.4. Operating Condition of EUT ......................................................................................................... 34 8.5. Test Procedure ............................................................................................................................... 34 8.6. Te…
Text truncated - open the document above for the full version.
FCC ID: 2ABTAHNL15HD Page 50 of 51 AUDIX Technology Corporation Report No. EM-F150003 12. PHOTOGRAPHS 12.1. Photos of Radiated Measurement at Semi-Anechoic Chamber 12.1.1.Frequency Range 30MHz~1GHz 12.1.2.Frequency Range Above 1GHz FCC ID: 2ABTAHNL15HD Page 51 of 51 AUDIX Technology Corporation Report No. EM-F150003 12.2. Photo of Section RF Conducted Measurement
FCC ID: 2ABTAHNL15HD Page 50 of 51 AUDIX Technology Corporation Report No. EM-F150003 12. PHOTOGRAPHS 12.1. Photos of Radiated Measurement at Semi-Anechoic Chamber 12.1.1.Frequency Range 30MHz~1GHz 12.1.2.Frequency Range Above 1GHz FCC ID: 2ABTAHNL15HD Page 51 of 51 AUDIX Technology Corporation Report No. EM-F150003 12.2. Photo of Section RF Conducted Measurement
No. 53-11, Dingfu, Linkou Dist., · New Taipei City · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 4.40 mW |

Automatic Upper Arm Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Automatic Upper Arm Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Automatic Upper Arm Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Automatic Upper Arm Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Automatic Wrist Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System