FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ACOEM/
  3. 2AC3Z-EGL1102

2AC3Z-EGL1102RADIO FREQUENCY SENSOR

ACOEM
RADIO FREQUENCY SENSOR - FCC ID 2AC3Z-EGL1102 - ACOEM
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 11, 2015
Application Purpose
Original Equipment
Date of Application
Mar 10, 2015
Equipment Note
RADIO FREQUENCY SENSOR
Frequency Range
2405.00000000 - 2475.00000000
Company
ACOEM
Country
France

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

EAGLE USER MANUAL ADAPTER LA COUVERTURE A EAGLE EAGLE Safety Instruction-Instructions de sécurité www.acoemgroup.com [email protected] Copyright © 2014 - 01dB-Metravib SAS This document is the property of 01dB-Metravib SAS. Any dissemination, copying or publicising of this document, in whole or in part, is prohibited without the owner’s written authorisation Document reference : NOTXXXX –_December 2014_A(MXX_NOT_16_A) Name : EAGLE Safety instruction EAGLE USER MANUAL Table of contents Chapter 1 Safety instructions 3 1. Symbols for sensors, expander and gateway .............................................................................................................................. 3 2. Sensors and expanders ............................................................................................................................................................... 4 2.1. Identification ............................................................................................................................................................................ 4 2.2. Installation / disassembly ........................................................................................................................................................ 4 2.3. Hazardous environments ........................................................................................................................................................ 5 2.4. Primary cell ............................................................................................................................................................................. 6 2.5. Storage ................................................................................................................................................................................... 6 2.6. Transportation......................................................................................................................................................................... 6 3. Gateway ....................................................................................................................................................................................... 7 3.1. Identification ............................................................................................................................................................................ 7 3.2. Installation / disassembly ........................................................................................................................................................ 7 3.3. Hazardous environments ........................................................................................................................................................ 7 3.4. Connections ............................................................................................................................................................................ 7 3.5. Storage ................................................................................................................................................................................... 7 4. Power over Ethernet .................................................................................................................................................................... 8 5. General ........................................................................................................................................................................................ 8 5.1. Devices integrity ..................................................................................................................................................................... 8 5.2. Operating environment ........................................................................................................................................................... 8 5.3. Maintenance, service and modifications................................................................................................................................. 8 5.4. Certifications data ................................................................................................................................................................... 8 5.5. FCC and IC ............................................................................................................................................................................. 9 5.6. Dismantling / recycling .......................................................................................................................................................... 10 6. ANNEX: Summary of marking meaning for hazardous areas ................................................................................................... 10 Chapter 2 Instructions de sécurité 11 1. Symboles sur les capteurs, répéteur et gateway ....................................................................................................................... 11 2. Capteurs et répéteur. ................................................................................................................................................................. 12 2.1. Identification .......................................................................................................................................................................... 12 2.2. Installation / démontage ....................................................................................................................................................... 12 2.3. Atmosphère explosives ........................................................................................................................................................ 13 2.4. Pile ................................................................................................................................................................................…

Text truncated - open the document above for the full version.

Users Manual

EAGLE USER MANUAL ADAPTER LA COUVERTURE A EAGLE EAGLE User Manual www.acoemgroup.com [email protected] Copyright © 2014 - 01dB-Metravib SAS This document is the property of 01dB-Metravib SAS. Any dissemination, copying or publicising of this document, in whole or in part, is prohibited without the owner’s written authorisation Document reference : MXX_NOT_13_D_DOCXXXX – December 2014D Name : EAGLE User manual EAGLE USER MANUAL Table of contents Chapter 1 Presentation 7 1. Introduction .................................................................................................................................................................................. 8 1. General presentation ................................................................................................................................................................... 8 1.1. Eagle devices ......................................................................................................................................................................... 8 1.2. Eagle network ......................................................................................................................................................................... 9 1.3. Radio communication ........................................................................................................................................................... 10 1.4. Eagle accessories................................................................................................................................................................. 11 Chapter 2 Installation guide 14 1. Site survey ................................................................................................................................................................................. 15 1.1. Site Planning ......................................................................................................................................................................... 15 1.2. Field test ............................................................................................................................................................................... 16 2. Installation prerequisites ............................................................................................................................................................ 17 2.1. Safety .................................................................................................................................................................................... 17 2.2. Site survey ............................................................................................................................................................................ 17 2.3. Fastening support ................................................................................................................................................................. 17 2.4. Network and power ............................................................................................................................................................... 17 3. Gateway installation ................................................................................................................................................................... 18 3.1. Location ................................................................................................................................................................................ 18 3.2. Mount .................................................................................................................................................................................... 19 3.3. Connection to the gateway ................................................................................................................................................... 20 3.4. Connection to the PoE .......................................................................................................................................................... 21 3.5. Sizes ..................................................................................................................................................................................... 22 4. Sensors installation .................................................................................................................................................................... 23 4.1. Sensor Location .................................................................................................................................................................... 23 4.2. Mounting information for sensors ......................................................................................................................................... 23 5. Expander installation .................................................................................................................................................................. 30 5.1. Expander location ................................................................................................................................................................. 30 5.2. Expander mounting............................................................................................................................................................... 30 6. Battery replacement (sensors / expander) ................................................................................................................................. 33 7. Protections ................................................................................................................................................................................. 34 7.1. Fall protection ........................................................................................................................................................…

Text truncated - open the document above for the full version.

Users Manual

Page 1/2 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE USER MANUAL (FCC STATEMENT) FCCID: 2AC3Z-EGL1102 This is a copy of the page where the FCC statement is included: MXX_NOT_16_RevA_NOTXXXX 2014-11-28 D - EAGLESafety InstructionsGB FR Page 2/2 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE

External Photos

Page 1/3 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE EXTERNAL PHOTOS OF EQUIPMENT FCCID: 2AC3Z-EGL1102 Page 2/3 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE Page 3/3 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE

ID Label/Location Info

Page 1/4 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE PRODUCT LABELING FCCID: 2AC3Z-EGL1102 Page 2/4 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE Page 3/4 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE Page 4/4 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE

Internal Photos

Page 1/5 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE INTERNAL PHOTOS OF EQUIPMENT FCCID: 2AC3Z-EGL1102 Page 2/5 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE Page 3/5 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE Page 4/5 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE Page 5/5 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE

Operational Description

LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE GENERAL INFORMATION FCCID: 2AC3Z-EGL1102 1.1. Product description LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE 1.2. Tested System Details Power supply: During all the tests, EUT is supplied by V nom : 3.6VDC For measurement with different voltage, it will be presented in test method. Name Type Rating Reference / Sn Comments Battery  AC  DC  Battery 3.6VDC Inputs/outputs - Cable: Access Type Length used (m) Declared <3m Shielded Under test Comments None Auxiliary equipment used during test: Type Reference Sn Comments Laptop DELL Precision 8P3J5S1 - ITE power supply PW180KB4800N01 - - GATEWAY - EAGLE- 0009B3 Used in “Remote” mode Equipment information: Type: ZIGBEE Frequency band: [2400 – 2483.5] MHz Sub-band REC7003: Annex 3 (a) Spectrum Modulation:  DSSS Number of Channel: 16 Spacing channel: 5MHz Channel bandwidth: 2MHz Transmit chains:  1  2  3  4  Single antenna  Symmetrical  Asymmetrical Gain 1: 3dBi Gain 2: dBi Gain 3: dBi Gain 4: dBi Beam forming gain:  Yes: dB  No Receiver chains  1  2  3  4 Type of equipment:  Stand-alone  Plug-in  Combined Ad-Hoc mode:  Yes  No Adaptivity mode:  Yes (Load Based)  Off mode  No Clear Channel Assessment Time: None q value for Load Based Equipment: None Duty cycle:  Continuous duty  Intermittent duty  Continuous operation Equipment type:  Production model  Prototype Module reference: AT86RF233-ZU Temperature range: Tmin:  -20°C  0°C  °C Tnom: 20°C Tmax:  35°C  55°C  85°C Test source voltage:  AC:  DC:  Battery: 3.6VDC / Lithium-Ion LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE CHANNEL PLAN Channel Frequency (MHz) Cmin: 11 2405 12 2410 13 2415 14 2420 15 2425 16 2430 17 2435 Cmid: 18 2440 19 2445 20 2450 21 2455 22 2460 23 2465 24 2470 Cmax: 25 2475 26* 2480 *Not used by the provider. DATA RATE Data Rate (Mbps) Modulation Type Worst Case Modulation 0.25 O-QPSK  The EUT is set in the following modes during tests with simulator / software (Unknown): The command is send by Gateway in “Remote” mode. - Permanent emission with modulation on a fixed channel in the data rate that produced the highest power - Permanent reception - The power is set at 3dBm 1.3. Test Methodology Both conducted and radiated testing were performed according to the procedures in ANSI C63.4-2003, FCC Part 15 Subpart C. Radiated testing was performed at an antenna to EUT distance of 10 meters. During testing, all equipment’s and cables were moved relative to each other in order to identify the worst case set-up. 1.4. Test facility Tests have been performed from October 13th to 21th, 2014. This test facility has been fully described in a report and accepted by FCC as compliant with the radiated and AC line conducted test site criteria in ANSI C63.4-2003 in a letter dated March 25 th , 2008 (registration number 94821). This test facility has also been accredited by COFRAC (French accreditation authority for European Union test lab accreditation organization) according to NF EN ISO/IEC 17025, accreditation number 1-1633 as compliant with test site criteria and competence in 47 CFR Part 15/ANSI C63.4 and EN55022/CISPR22 norms for 89/336/EEC European EMC Directive application. All pertinent data for this test facility remains unchanged.

RF Exposure Info

LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE FCCID: 2AC3Z-EGL1102 Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Prediction Frequency MHz Conducted Output Power dBm Max Antenna Gain dBi Distance cm Power Density mW/cm2 Limit mW/cm2 24050.793200.00051.00 244013200.00051.00 24750.663200.00051.00 Conclusion: Therefore our device complies with FCC’s RF radiation exposure limits for general population without SAR evaluation with at least 20cm separation from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Test Report

This document shall not be reproduced, except in full, without the written approval of the LCIE. This document contains results related only to the item tested. It does not imply the conformity of the whole production to the item tested .Unless otherwise specified; the decision of conformity takes into account the uncertainty of measures. This document does not anticipate any certification decision. TEST REPORT N°: 770941-A1-R2-E JDE : 661007 Subject Electromagnetic compatibility and Radio spectrum Matters (ERM) tests according to standards: FCC CFR 47 Part 15, Subpart B et C RSS-210 Issue 8 Issued to ACOEM 200 Chemin des Ormeaux 69578 LIMONEST - FRANCE Apparatus under test  Product MXX Captor  Trade mark ACOEM  Manufacturer ACOEM  Model EGL1102000 – EGL1103000 – EGL1104000  Model under test EGL1103000  Serial number EAGLE- 00099F & EAGLE- 000989  FCCID 2AC3Z-EGL1102  ICID 12336A-EGL1102 Test date From October 13 hd to 21 st , 2014 Test location Moirans Test performed by Anthony MERLIN / Gaëtan DESCHAMPS Composition of document 31 pages Modification of the last version None Document issued on December 22 th , 2014 Written by : Approved by : Anthony MERLIN Jacques LORQUIN Tests operator Technical manager TEST REPORT N°770941-A1-R2-E Page 2/31 SUMMARY 1. TEST PROGRAM ............................................................................................................................... 3 2. SYSTEM TEST CONFIGURATION ..................................................................................................... 4 3. RADIATED EMISSION DATA ............................................................................................................. 8 4. BANDWIDTH (15.247) ...................................................................................................................... 12 5. MAXIMUM PEAK OUTPUT POWER (15.247) .................................................................................. 15 6. POWER SPECTRAL DENSITY (15.247) .......................................................................................... 18 7. BAND EDGE MEASUREMENT (15.247) .......................................................................................... 21 8. OCCUPIED BANDWIDTH ................................................................................................................. 25 9. ANNEX 1 (GRAPHS < 1GHZ) ........................................................................................................... 27 10. UNCERTAINTIES CHART ................................................................................................................ 31 TEST REPORT N°770941-A1-R2-E Page 3/31 1. TEST PROGRAM Standard: - FCC Part 15, Subpart C 15.247 - ANSI C63.4 (2003) - RSS-210 Issue 8 – Dec 2010 - RSS-Gen Issue 3 – Dec 2010 EMISSION TEST LIMITS RESULTS Limits for conducted disturbance at mains ports 150kHz-30MHz Frequency Quasi-peak value (dBμV) Average value (dBμV)  PASS  FAIL  NA  NP 150-500kHz 66 to 56 56 to 46 0.5-5MHz 56 46 5-30MHz 60 50 Radiated emissions 9kHz-30MHz CFR 47 §15.209 (a) CFR 47 §15.247 (d) RSS-210 §A8.5 Measure at 300m 9kHz-490kHz : 67.6dBμV/m /F(kHz) Measure at 30m 490kHz-1.705MHz : 87.6dBμV/m /F(kHz) 1.705MHz-30MHz : 29.5 dBμV/m  PASS  FAIL  NA  NP Radiated emissions 30MHz-25GHz* CFR 47 §15.209 (a) CFR 47 §15.247 (d) RSS-210 §A8.5 Highest frequency : (Declaration of provider) Measure at 3m 30MHz-88MHz : 40 dBμV/m 88MHz-216MHz : 43.5 dBμV/m 216MHz-960MHz : 46.0 dBμV/m Above 960MHz : 54.0 dBμV/m  PASS  FAIL  NA  NP Bandwidth 6dB CFR 47 §15.247 (a) (2) RSS-210 §A8.2 At least 500kHz  PASS  FAIL  NA  NP Maximum Peak Output Power CFR 47 §15.247 (b) RSS-210 §A8.4 (4) Limit: 30dBm Conducted or Radiated measurement  PASS  FAIL  NA  NP Band Edge Measurement CFR 47 §15.209 (a) CFR 47 §15.247 (d) RSS-210 §A8.5 Limit: -20dBc or Radiated emissions limits in restricted bands  PASS  FAIL  NA  NP Power spectral Density CFR 47 §15.247 (e) RSS-210 §A8.2 Limit: 8dBm/3kHz  PASS  FAIL  NA  NP Occupied bandwidth RSS-Gen §4.6.1 No limit  PASS  FAIL  NA  NP Receiver Spurious Emission** RSS-Gen §4.10 See RSS-Gen §4.10  PASS  FAIL  NA  NP *§15.33: The highest internal source of a testing device is defined like more the highest frequency generated or used in the testing device or on which the testing device works or agrees. - If the highest frequency of the internal sources of the testing device is lower than 108 MHz, measurement must be only performed until 1GHz. - If the highest frequency of the internal sources of the testing device ranges between 108 MHz and 500 MHz, measurement must be only performed until 2GHz. - If the highest frequency of the internal sources of the testing device ranges between 500 MHz and 1 GHz, measurement must be only performed until 5GHz. If the highest frequency of the internal sources of the testing device is above 1 GHz, measurement must be only performed until 5 times the highest frequency or 40 GHz, while taking smallest of both. TEST REPORT N°770941-A1-R2-E Page 4/31 2. SYSTEM TEST CONFIGURATION 2.1. HARDWARE IDENTIFICATION (EUT AND AUXILIARIES): Equipment under test (EUT): EGL1103000 Serial Number: EAGLE- 00099F Photography of EUT Power supply: During all the tests, EUT is supplied by V nom : 3.6VDC For measurement with different voltage, it will be presented in test method. Name Type Rating Reference / Sn Comments Battery  AC  DC  Battery 3.6VDC TEST REPORT N°770941-A1-R2-E Page 5/31 Inputs/outputs - Cable: Access Type Length used (m) Declared <3m Shielded Under test Comments None Auxiliary equipment used during test: Type Reference Sn Comments Laptop DELL Precision 8P3J5S1 - ITE power supply PW180KB4800N01 - - GATEWAY - EAGLE- 0009B3 Used in “Remote” mode Equipment information: Type: ZIGBEE Frequency band: [2400 – 2483.5] MHz Sub-band REC7003: Annex 3 (a) Spectrum Modulation:  DSSS Number of Channel: 15 Spacing channel: 5MHz Channel bandwidth: 2MHz Transmit chains:  1  2  3 …

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1/1 LCIE Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS-FRANCE CONDUCTED AND RADIATED MEASUREMENT PHOTO FCCID: 2AC3Z-EGL1102 1.1 Radiated emissions Configuration 1 in Axis XY Configuration 1 in Axis Z

Contact Information

Applicant

FABIEN CONDEMINE
[email protected]478663439Fax: 33478663439

Test Firm

LCIE Etablissement Sud-EstAnthony Merlin
[email protected]00-33-4-76-07-36-36Fax: 00-33-4-76-55-90-88

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation and operating instructions for satisfying RF exposure compliance requirements.

Other Applications from ACOEM

Wireless Sensor - FCC ID 2AC3Z-CAC1014000 - ACOEM
2AC3Z-CAC1014000

Wireless Sensor

Aug 27, 2026

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
RADIO FREQUENCY SENSOR - FCC ID 2AC3Z-CAC1005000 - ACOEM
2AC3Z-CAC1005000

RADIO FREQUENCY SENSOR

Mar 11, 2015

Equipment Class

DTS - Digital Transmission System
GATEWAY FOR RADIO FREQUENCY SENSOR - FCC ID 2AC3Z-EGL1101 - ACOEM
2AC3Z-EGL1101

GATEWAY FOR RADIO FREQUENCY SENSOR

Mar 11, 2015

Equipment Class

DTS - Digital Transmission System