FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Ā© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TCL Communication Ltd./
  3. 2ACCJH195

2ACCJH195GSM/UMTS/LTE/NR Mobile phone

TCL Communication Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 15, 2026
Application Purpose
Original Equipment
Equipment Note
GSM/UMTS/LTE/NR Mobile phone
Frequency Range
2402.00000000 - 2480.00000000
Company
TCL Communication Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Test Report

` Report No.: SUCR251000105501 Page: 171 of 171 - End of the Appendix -

RF Exposure Info

0 dB = 0.0467 W/kg = -13.31 dBW/kg Date: 2025/11/24 Test Laboratory: SGS-SAR Lab T807M LTE Band 38 20M QPSK 1RB0 38000CH Left cheek DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, LTE-TDD BW 20MHz (0); Frequency: 2595 MHz;Duty Cycle: 1:1.58 Medium: HSL2600;Medium parameters used: f = 2595 MHz; σ = 2.01 S/m; ε r = 38.997; ρ = 1000 kg/m 3 Phantom section: Left Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(7.85, 7.85, 7.85); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Head/Area Scan (10x17x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.0437 W/kg Configuration/Head/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 0.0590 W/kg SAR(1 g) = 0.031 W/kg; SAR(10 g) = 0.016 W/kg Smallest distance from peaks to all points 3 dB below = 8.6 mm Ratio of SAR at M2 to SAR at M1 = 54.1% Maximum value of SAR (measured) = 0.0467 W/kg 0 dB = 1.03 W/kg = 0.13 dBW/kg Date: 2025/11/24 Test Laboratory: SGS-SAR Lab T807M LTE Band 38 20M QPSK 1RB0 38000CH Back side 10mm DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, LTE-TDD BW 20MHz (0); Frequency: 2595 MHz;Duty Cycle: 1:1.58 Medium: HSL2600;Medium parameters used: f = 2595 MHz; σ = 2.01 S/m; ε r = 38.997; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(7.85, 7.85, 7.85); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Body/Area Scan (10x17x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.817 W/kg Configuration/Body/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 1.319 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 1.29 W/kg SAR(1 g) = 0.602 W/kg; SAR(10 g) = 0.261 W/kg Smallest distance from peaks to all points 3 dB below = 7.2 mm Ratio of SAR at M2 to SAR at M1 = 47.4% Maximum value of SAR (measured) = 1.03 W/kg 0 dB = 1.45 W/kg = 1.61 dBW/kg Date: 2025/11/24 Test Laboratory: SGS-SAR Lab T807M LTE Band 41 PC2 20M QPSK 1RB0 40620CH Right cheek DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, LTE-TDD BW 20MHz (0); Frequency: 2593 MHz;Duty Cycle: 1:2.31 Medium: HSL2600;Medium parameters used: f = 2593 MHz; σ = 1.995 S/m; ε r = 38.947; ρ = 1000 kg/m 3 Phantom section: Right Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(7.85, 7.85, 7.85); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Head/Area Scan (10x15x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 1.20 W/kg Configuration/Head/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.564 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 1.96 W/kg SAR(1 g) = 0.843 W/kg; SAR(10 g) = 0.380 W/kg Smallest distance from peaks to all points 3 dB below = 8.1 mm Ratio of SAR at M2 to SAR at M1 = 44.8% Maximum value of SAR (measured) = 1.45 W/kg 0 dB = 1.25 W/kg = 0.97 dBW/kg Date: 2025/11/24 Test Laboratory: SGS-SAR Lab T807M LTE Band 41 PC2 20M QPSK 1RB0 40620CH Back side 10mm DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, LTE-TDD BW 20MHz (0); Frequency: 2593 MHz;Duty Cycle: 1:2.31 Medium: HSL2600;Medium parameters used: f = 2593 MHz; σ = 1.995 S/m; ε r = 38.947; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(7.85, 7.85, 7.85); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Body/Area Scan (10x17x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 1.19 W/kg Configuration/Body/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.019 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.52 W/kg SAR(1 g) = 0.821 W/kg; SAR(10 g) = 0.375 W/kg Smallest distance from peaks to all points 3 dB below = 10.3 mm Ratio of SAR at M2 to SAR at M1 = 50.9% Maximum value of SAR (measured) = 1.25 W/kg 0 dB = 1.11 W/kg = 0.45 dBW/kg Date: 2025/11/26 Test Laboratory: SGS-SAR Lab T807M LTE Band 42 20M QPSK 1RB0 42590CH Right cheek DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, LTE-TDD BW 20MHz (0); Frequency: 3500 MHz;Duty Cycle: 1:1.58 Medium: HSL3500;Medium parameters used: f = 3500 MHz; σ = 2.964 S/m; ε r = 38.453; ρ = 1000 kg/m 3 Phantom section: Right Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(7.23, 7.23, 7.23); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Head/Area Scan (11x19x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 1.06 W/kg Configuration/Head/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm Reference Value = 3.014 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 1.61 W/kg SAR(1 g) = 0.605 W/kg; SAR(10 g) = 0.231 W/kg Smallest distance from peaks to all points 3 dB below = 5.6 mm Ratio of SAR at M2 to SAR at M1 = 78.7% Maximum value of SAR (measured) = 1.11 W/kg 0 dB = 0.932 W/kg = -0.31 dBW/kg Date: 2025/11/26 Test Laboratory: SGS-SAR Lab T80…

Text truncated - open the document above for the full version.

RF Exposure Info

` Appendix B Detailed Test Results 1. GSM GSM850 GSM1900 2. WCDMA WCDMA Band II WCDMA Band IV WCDMA Band V 3. LTE LTE Band 7 LTE Band 12 LTE Band 13 LTE Band 14 LTE Band 25 LTE Band 26 LTE Band 30 LTE Band 38 LTE Band 41 LTE Band 42 LTE Band 48 LTE Band 66 LTE Band 71 4. NR 5G NR n7 5G NR n12 5G NR n14 5G NR n25 5G NR n26 5G NR n30 5G NR n41 5G NR n48 5G NR n66 5G NR n70 5G NR n71 5G NR n77 5. WIFI WIFI 2.4G WIFI 5G WIFI 6E 6. Bluetooth 7. NFC 8. PD Report No.: SUCR251100114801 Page: 1 of 95 0 dB = 0.175 W/kg = -7.57 dBW/kg Date: 2025/11/14 Test Laboratory: SGS-SAR Lab T807M GSM850 GPRS 4TS 190CH Right cheek DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, GPRS/EGPRS Mode(4up) Communication System (0); Frequency: 836.6 MHz;Duty Cycle: 1:2.075 Medium: HSL835;Medium parameters used: f = 837 MHz; σ = 0.924 S/m; ε r = 42.308; ρ = 1000 kg/m 3 Phantom section: Right Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(10.34, 10.34, 10.34); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Head/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.173 W/kg Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.144 V/m; Power Drift = -0.14 dB Peak SAR (extrapolated) = 0.184 W/kg SAR(1 g) = 0.128 W/kg; SAR(10 g) = 0.094 W/kg Smallest distance from peaks to all points 3 dB below = 10.1 mm Ratio of SAR at M2 to SAR at M1 = 78% Maximum value of SAR (measured) = 0.175 W/kg 0 dB = 0.445 W/kg = -3.52 dBW/kg Date: 2025/11/14 Test Laboratory: SGS-SAR Lab T807M GSM850 GPRS 4TS 190CH Back side 10mm DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, GPRS/EGPRS Mode(4up) Communication System (0); Frequency: 836.6 MHz;Duty Cycle: 1:2.075 Medium: HSL835;Medium parameters used: f = 837 MHz; σ = 0.924 S/m; ε r = 42.308; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(10.34, 10.34, 10.34); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Body/Area Scan (9x14x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.439 W/kg Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 9.359 V/m; Power Drift = -0.16 dB Peak SAR (extrapolated) = 0.534 W/kg SAR(1 g) = 0.402 W/kg; SAR(10 g) = 0.261 W/kg Smallest distance from peaks to all points 3 dB below = 11.3 mm Ratio of SAR at M2 to SAR at M1 = 57.3% Maximum value of SAR (measured) = 0.445 W/kg 0 dB = 0.700 W/kg = -1.55 dBW/kg Date: 2025/11/16 Test Laboratory: SGS-SAR Lab T807M GSM1900 GPRS 4TS 661CH Right cheek DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, GPRS/EGPRS Mode(4up) Communication System (0); Frequency: 1880 MHz;Duty Cycle: 1:2.075 Medium: HSL1950;Medium parameters used: f = 1880 MHz; σ = 1.387 S/m; ε r = 40.834; ρ = 1000 kg/m 3 Phantom section: Right Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(8.6, 8.6, 8.6); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Head/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.649 W/kg Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 12.51 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 0.837 W/kg SAR(1 g) = 0.486 W/kg; SAR(10 g) = 0.271 W/kg Smallest distance from peaks to all points 3 dB below = 12.2 mm Ratio of SAR at M2 to SAR at M1 = 60.1% Maximum value of SAR (measured) = 0.700 W/kg 0 dB = 0.572 W/kg = -2.43 dBW/kg Date: 2025/11/16 Test Laboratory: SGS-SAR Lab T807M GSM1900 GPRS 4TS 661CH Back side 10mm DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, GPRS/EGPRS Mode(4up) Communication System (0); Frequency: 1880 MHz;Duty Cycle: 1:2.075 Medium: HSL1950;Medium parameters used: f = 1880 MHz; σ = 1.387 S/m; ε r = 40.834; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(8.6, 8.6, 8.6); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Configuration/Body/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.556 W/kg Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 9.687 V/m; Power Drift = 0.17 dB Peak SAR (extrapolated) = 0.611 W/kg SAR(1 g) = 0.459 W/kg; SAR(10 g) = 0.188 W/kg Smallest distance from peaks to all points 3 dB below = 11.3 mm Ratio of SAR at M2 to SAR at M1 = 55.4% Maximum value of SAR (measured) = 0.572 W/kg 0 dB = 1.06 W/kg = 0.25 dBW/kg Date: 2025/11/16 Test Laboratory: SGS-SAR Lab T807M GSM1900 GPRS 4TS 661CH 10mm DUT: T807M; Type: Smart phone; Serial: 016765000001156 Communication System: UID 0, GPRS/EGPRS Mode(2up) Communication System (0); Frequency: 1880 MHz;Duty Cycle: 1:4.15 Medium: HSL1950;Medium parameters used: f = 1880 MHz; σ = 1.387 S/m; ε r = 40.834; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(8.6, 8.6, 8.6); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Confi…

Text truncated - open the document above for the full version.

RF Exposure Info

` Appendix A Detailed System Check Results 1. System Performance Check System Performance Check 13 MHz Head System Performance Check 750 MHz Head System Performance Check 835 MHz Head System Performance Check 1750 MHz Head System Performance Check 1950 MHz Head System Performance Check 2300 MHz Head System Performance Check 2450 MHz Head System Performance Check 2600 MHz Head System Performance Check 3500 MHz Head System Performance Check 3700 MHz Head System Performance Check 3900 MHz Head System Performance Check 5250 MHz Head System Performance Check 5600 MHz Head System Performance Check 5750 MHz Head System Performance Check 6500 MHz Head System Performance Check 10GHz Report No.: SUCR251100114801 Page: 1 of 18 Date: 2025-11-25Test Laboratory: SGS-SAR Lab System Performance Check 13MHz Communication System: CLA13; Frequency: 13.000 Medium: HSL. Medium parameters used: f= 13.000 MHz; σ= 0.767 S/m; ε r = 55.5 DASY8 Configuration: - Probe: EX3DV4 - SN7735; ConvF(13.68, 13.51, 13.73); Calibrated: 2025-01-29 - Sensor-Surface: 1.4 mm - Electronics: DAE4ip Sn1826; Calibrated: 2025-02-17 - Phantom: ELI V8.0 (20deg probe tilt); Serial: 2217 - Measurement Software: cDASY8 V16.4.0.5005 Area Scan (120.0 mm x 210.0 mm): Measurement Grid: 15.0 mm x 15.0 mm SAR (1g) = 0.102 W/kg; SAR (10g) = 0.084 W/kg; Zoom Scan (30.0 mm x 30.0 mm x 30.0 mm): Measurement Grid: 6.0 mm x 6.0 mm x 1.5 mm Power Drift = -0.01 dB SAR (1g) = 0.101 W/kg; SAR (10g) = 0.063 W/kg; M2/M1 [%]75.1 Dist 3dB Peak [mm]16.1 0 dB = 3.03 W/kg = 4.81 dBW/kg Date: 2025/11/20 Test Laboratory: SGS-SAR Lab System Performance Check 750 MHz Head DUT: D750V3; Type: Dipole; Serial: 1214 Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1 Medium: HSL750;Medium parameters used: f = 750 MHz; σ = 0.91 S/m; ε r = 42.706; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(10.76, 10.76, 10.76); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Body/d=15mm, Pin=250mW/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.76 W/kg Body/d=15mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 44.31 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 3.48 W/kg SAR(1 g) = 2.18 W/kg; SAR(10 g) = 1.45 W/kg Smallest distance from peaks to all points 3 dB below = 16.7 mm Ratio of SAR at M2 to SAR at M1 = 63.1% Maximum value of SAR (measured) = 3.03 W/kg 0 dB = 3.26 W/kg = 5.13 dBW/kg Date: 2025/11/14 Test Laboratory: SGS-SAR Lab System Performance Check 835 MHz Head DUT: D835V2; Type: Dipole; Serial: 4d161 Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1 Medium: HSL835;Medium parameters used: f = 835 MHz; σ = 0.921 S/m; ε r = 42.378; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(10.34, 10.34, 10.34); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Body/d=15mm, Pin=250mW/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.13 W/kg Body/d=15mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 54.26 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 3.92 W/kg SAR(1 g) = 2.46 W/kg; SAR(10 g) = 1.65 W/kg Smallest distance from peaks to all points 3 dB below = 17.6 mm Ratio of SAR at M2 to SAR at M1 = 65.4% Maximum value of SAR (measured) = 3.26 W/kg 0 dB = 15.6 W/kg = 11.93 dBW/kg Date: 2025/11/18 Test Laboratory: SGS-SAR Lab System Performance Check 1750 MHz Head DUT: D1750V2; Type: Dipole; Serial: 1105 Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1 Medium: HSL1750;Medium parameters used: f = 1750 MHz; σ = 1.4 S/m; ε r = 40.939; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(8.95, 8.95, 8.95); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Body/d=10mm, Pin=250mW/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 12.1 W/kg Body/d=10mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 88.73 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 18.3 W/kg SAR(1 g) = 9.5 W/kg; SAR(10 g) = 5.01 W/kg Smallest distance from peaks to all points 3 dB below = 9.6 mm Ratio of SAR at M2 to SAR at M1 = 53.5% Maximum value of SAR (measured) = 15.6 W/kg 0 dB = 14.7 W/kg = 11.67 dBW/kg Date: 2025/11/16 Test Laboratory: SGS-SAR Lab System Performance Check 1950 MHz Head DUT: D1950V3; Type: Dipole; Serial: 1218 Communication System: UID 0, CW (0); Frequency: 1950 MHz;Duty Cycle: 1:1 Medium: HSL1950;Medium parameters used: f = 1950 MHz; σ = 1.421 S/m; ε r = 40.622; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY 5 Configuration: • Probe: EX3DV4 - SN7767; ConvF(8.6, 8.6, 8.6); Calibrated: 2024/12/31 • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1245; Calibrated: 2025/09/08 • Phantom: SAM 1; Type: SAM; Serial: 1609 • DASY52 52.10.4(1527); SEMCAD X 14.6.14(7483) Body/d=10mm, Pin=250mW/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 12.1 W/kg Body/d=10mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 80.47 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 17.5 W/kg SAR(1 g) = 10.5 W/kg; SAR(10 g) = 5.51 W/kg Smallest distance from peaks to all points 3 dB below = 9.6 mm Ratio of SAR at M2 to S…

Text truncated - open the document above for the full version.

Test Report

DipoleCD3500V3_3300MHz_SN1024 HeadLiquid Dateof Measurement Return Loss(dB) Ī”% Impedance (Ω) ΔΩ Impedance imaginary (jΩ) Ī”jĪ© 2023/10/24 18.6/63.2/-1.2/ 2024/10/2318.31.61%63.10.1-1.360.16 2025/10/2218.4-0.55%63.3-0.2-1.28-0.08 DipoleCD3500V3_3400MHz_SN1024 HeadLiquid Dateof Measurement Return Loss(dB) Ī”% Impedance (Ω) ΔΩ Impedance imaginary ( jĪ© ) Ī”jĪ© 2023/10/2424.8/54.2/-4.2/ 2024/10/2324.60.81%54.10.1-4.30.1 2025/10/22 24.7-0.41%53.90.2-4.1-0.2 DipoleCD3500V3_3500MHz_SN1024 HeadLiquid Dateof Measurement Return Loss(dB) Ī”% Impedance (Ω) ΔΩ Impedance imaginary (jΩ) Ī”jĪ© 2023/10/2425.6/53.8/-3.9/ 2024/10/23 25.8-0.78%53.9-0.1-3.8-0.1 2025/10/2225.41.55%53.70.2-3.7-0.1 DipoleCD3500V3_3600MHz_SN1024 HeadLiquid Dateof Measurement Return Loss(dB) Ī”% Impedance (Ω) ΔΩ Impedance imaginary (jΩ) Ī”jĪ© 2023/10/24 23.7/50/-6.5/ 2024/10/2323.41.27%49.80.2-6.60.1 2025/10/2223.6-0.85%50.1-0.3-6.4-0.2 DipoleCD3500V3_3700MHz_SN1024 HeadLiquid Dateof Measurement Return Loss(dB) Ī”% Impedance (Ω) ΔΩ Impedance imaginary ( jĪ© ) Ī”jĪ© 2023/10/2423.5/44/-1.8/ 2024/10/23 23.30.85%43.80.2-1.90.1 2025/10/2223.20.43%43.70.1-1.7-0.2 ` Report No.: SUCR251000105502 Page: 48 of 48 - End of the Appendix -

Test Report

` Report No.: SUCR251000105502 Page: 1 of 48 Appendix C Calibration certificate 1.Dipole CD835V3-SN1052 CD1880V3-SN1044 CD2600V3-SN1021 CD3500V3-SN1024 2.DAE DAE4-SN1740 3.Probe EF3DV3-SN4051 4.Dipole Extend

Test Report

` Report No.: SUCR251000105502 Page: 1 of 7 Appendix B Detailed Test Results 1.GSM GSM850 ANT2 for E-Field Emission GSM1900 ANT0 for E-Field Emission 2.LTE LTE Band 41 PC2 ANT7 for E-Field Emission 3.5G NR FR1 n41 PC2&1.5 ANT3 for E-Field Emission FR1 n41 PC2&1.5 ANT7 for E-Field Emission FR1 n77 PC2 ANT4 for E-Field Emission RF Interference Potential Test Report Measurement performed on November 26, 2025 at 13:52 Device Under Test Manufacturer Model Dimensions[mm ] 146.2 X 71.8 X 7.5 Speaker Position [mm ] 144.3 Hardware Setup Probe Name EF3DV3 - SN4051 Probe Calibration Date September 25, 2025 DAE Name DAE4 Sn1740 DAE Calibration Date February 17, 2025 Communication Systems Band Name Band 41, E-UTR矿DD Communication Systems Name LTE-TDD (SC-FDMA, 1 RB, 20 MHz, QPSK ) Channel 41490 Frequen cy [MHz ] 2680.0 Grid Setting s Extent X [mm ] 50.0 Extent Y [mm ] 50.0 StepX [mm ] 10.0 StepY [mm ] 10.0 Distance [mm ] 15.0 Results Emax [dB(V/m ) ] 31.08 Eavg50x50 max [dB(V/m ) ] 28.24 MIF [dB ] -1.44 RFail [dB(V/m ) ] 26.62 Interpolated E-field (d80f/m)) 0 02 00' - ] äø€ äŗ” 二 0 001 002 -003 -002 -001 001 002 003 Y[m RF Interference Potential Test Report Measurement performed on November 26, 2025 at 15:20 Device Under Test Manufacturer Model Dimensions[mm ] 146.2 X 71.8 X 7.5 Hardware Setup Probe Name EF3DV3 - SN4051 Probe Calibration Date September 25, 2025 DAE Name DAE4 Sn1740 Communication Systems Band Name Band n41 Grid Settings Extent X [mm ] 50.0 Results Emax [dB(V/m ) ] 36.78 Communication Systems Name 5G NR (DFT-s-OFDM, 1 RB, 100 MHz, QPSK, 30 kHz ) Extent Y [mm ] 50.0 StepX [mm ] 10.0 Eavg50x50 max [dB(V/m ) ] 33.26 Channel 518598 StepY [mm ] 10.0 MIF [dB] -1.64 Speaker Position [mm ] 144.3 DAE Calibration Date February 17, 2025 Frequen cy [MHz ] 2592.99 Distance [mm ] 15.0 RFail [dB(V/ m ) ] 31.62 ` Report No.: SUCR251000105502 Page: 7 of 7 - End of the Appendix -

Test Report

` AppendixA DetailedSystemCheckResults 1. System Check Results System Performance Check 835 MHz System Performance Check 1880 MHz System Performance Check 2600 MHz System Performance Check 3500 MHz Report No.: SUCR251000105502 Page: 1 of 6 ` Report No.: SUCR251000105502 Page: 6 of 6 - End of the Appendix -

Test Report

` Report No.: SUCR251000105502 Page: 1 of 31 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-755) 8307 1443, or email: [email protected] RF-Emission Test Report Application No.: SUCR2510001055WM Applicant: TCL Communication Ltd. Address of Applicant: 5/F, Building 22E, 22 Science Park East Avenue, Hong Kong Science Park, Shatin, NT, Hong Kong Manufacturer: TCL Communication Ltd. Address of Manufacturer: 5/F, Building 22E, 22 Science Park East Avenue, Hong Kong Science Park, Shatin, NT, Hong Kong EUT Description: GSM/UMTS/LTE/NR Mobile phone Model No: T807M FCC ID: 2ACCJH195 Standards: ANSI C63.19-2019 CFR 47 FCC Part 20 Date of Receipt: 2025-10-29 Date of Test: 2025-11-25 to 2025-11-26 Date of Issue: 2025-12-06 Test Result: PASS * * In the configuration tested, the EUT detailed in this report complied with the standards specified above. ` Report No.: SUCR251000105502 Page: 2 of 31 Revision Record Version Description Date Remark 01 Original 2025-12-06 / Authorized for issue by: Alger Du/ Project Engineer Leon Liu/ Reviewer ` Report No.: SUCR251000105502 Page: 3 of 31 TEST SUMMARY Frequency Band HAC RF Emission Test result* Result s GSM 850 E-Field dB(V/m) 29.00 PASS PCS 1900 E-Field dB(V/m) 33.59 PASS WCDMA Band II E-Field dB(V/m) / PASS WCDMA Band IV E-Field dB(V/m) / PASS WCDMA Band V E-Field dB(V/m) / PASS LTE band 2 E-Field dB(V/m) / PASS LTE band 4 E-Field dB(V/m) / PASS LTE band 5 E-Field dB(V/m) / PASS LTE band 7 E-Field dB(V/m) / PASS LTE band 12 E-Field dB(V/m) / PASS LTE band 13 E-Field dB(V/m) / PASS LTE band 14 E-Field dB(V/m) / PASS LTE band 17 E-Field dB(V/m) / PASS LTE band 25 E-Field dB(V/m) / PASS LTE band 26 E-Field dB(V/m) / PASS LTE band 30 E-Field dB(V/m) / PASS LTE band 38 E-Field dB(V/m) / PASS LTE band 41 E-Field dB(V/m) 26.62 PASS LTE band 42 E-Field dB(V/m) / PASS LTE band 48 E-Field dB(V/m) / PASS LTE band 66 E-Field dB(V/m) / PASS LTE band 71 E-Field dB(V/m) / PASS FR1 n2 E-Field dB(V/m) / PASS FR1 n5 E-Field dB(V/m) / PASS FR1 n7 E-Field dB(V/m) / PASS FR1 n12 E-Field dB(V/m) / PASS FR1 n14 E-Field dB(V/m) / PASS FR1 n25 E-Field dB(V/m) / PASS FR1 n26 E-Field dB(V/m) / PASS FR1 n30 E-Field dB(V/m) / PASS FR1 n38 E-Field dB(V/m) / PASS FR1 n41 E-Field dB(V/m) 31.62 PASS FR1 n48 E-Field dB(V/m) / PASS FR1 n66 E-Field dB(V/m) / PASS FR1 n70 E-Field dB(V/m) / PASS FR1 n71 E-Field dB(V/m) / PASS FR1 n77 E-Field dB(V/m) 28.74 PASS FR1 n78 E-Field dB(V/m) / PASS WLAN2.4GHz E-Field dB(V/m) / PASS WLAN5GHz E-Field dB(V/m) / PASS WLAN6GHz E-Field dB(V/m) / PASS HAC Results: PASS Note: 1) This portable wireless equipment has been shown to be hearing-aid compatible under the above rated category, specified in ANSI/IEEE Std.C63.19-2019 and had been tested in accordance with the specified measurement procedures, Hear-Aid Compatibility is based on the assumption that all production units will be designed electrically identical to the device tested in this report. Test results reported herein relate only to the item(s) tested and are for North American Bands only. 2) *- HAC RF Emission Test for low power exemption according to ANSI C63.19-2019 and HAC RF Emission rating is PASS. ` Report No.: SUCR251000105502 Page: 4 of 31 CONTENTS 1 General Information .............................................................................................................. 5 1.1 Introduction ...................................................................................................................... 5 1.2 Test Location ................................................................................................................... 6 1.3 Test Facility ..................................................................................................................... 6 1.4 General Description of EUT ............................................................................................. 7 1.4.1 DUT Antenna Locations ............................................................................................... 9 1.4.2 List of air interfaces/frequency bands......................................................................... 10 1.5 Test Specification .......................................................................................................... 12 1.6 ANSI C63.19-2019 limits ............................................................................................... 12 2 Environmental Conditions .................................................................................................. 13 3 HAC (T Coil) Measurement System .................................................................................... 14 3.1 Measurement System Diagr…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 8 Appendix A Volume Control Test Data and Graph for Report No.: SUES251000220971 Page 2 of 8 The DUT shall have at least one volume control setting that will produce a conversational gain of ≄ 6. Verdict: Pass. 1.1 For codecs with bit rate, check the bit rate with the worst conversational gain Codec Codec Bitrate (kbps) Conv. Gain(dB) GSM850 WCDMA B2 LTE B41 NR n77 802.11b 2N 8N 2N 8N 2N 8N 2N 8N 2N 8N AMR-NB 4.75 14.51 19.19 14.41 18.63 13.26 17.88 13.60 18.13 14.21 16.97 5.15 14.71 19.24 14.47 18.65 13.31 18.02 13.65 18.31 14.25 17.11 5.9 14.73 19.41 14.53 18.78 13.32 18.05 13.67 18.34 14.43 17.26 6.7 15.23 19.42 14.63 18.87 13.49 18.09 13.72 18.37 14.49 17.75 7.4 15.25 19.57 14.64 19.17 13.55 18.13 13.86 18.51 14.89 18.51 7.95 15.28 19.72 14.65 19.19 13.72 18.26 13.94 18.57 14.94 18.60 10.2 15.34 19.77 14.79 19.27 13.85 18.48 14.03 18.59 14.96 18.77 12.2 15.42 19.97 14.83 19.43 13.87 18.52 14.28 18.61 14.99 19.68 AMR-WB 6.6 N/A 8.25 12.96 7.71 12.12 8.69 12.85 8.20 12.20 8.85 8.31 13.01 7.73 12.13 8.70 12.86 8.31 12.22 12.65 8.36 13.02 7.76 12.15 8.71 12.88 8.35 12.26 14.25 8.50 13.19 7.78 12.18 8.74 12.91 8.38 12.34 15.85 8.60 13.23 7.81 12.21 8.77 12.99 8.52 12.38 18.25 8.84 13.27 7.83 12.25 8.78 13.08 8.54 12.45 19.85 8.91 13.33 7.84 12.27 8.84 13.09 8.68 12.57 23.05 8.92 13.36 7.85 12.29 8.86 13.11 8.86 12.62 23.85 8.98 13.45 7.87 12.41 8.90 13.15 8.87 12.63 EVS-NB 5.9 N/A 14.29 19.20 14.19 18.90 13.99 19.01 7.2 14.30 19.24 14.26 19.17 14.18 19.09 8 14.34 19.38 14.41 19.28 14.20 19.20 9.6 14.43 19.45 14.44 19.35 14.21 19.52 13.2 14.45 19.63 14.52 19.39 14.40 19.53 16.4 14.51 19.68 14.61 19.44 14.48 19.54 24.4 14.79 19.77 14.77 19.45 14.51 19.62 EVS-WB 5.9 8.12 13.29 8.36 12.90 8.26 12.96 7.2 8.13 13.35 8.41 12.93 8.32 13.01 8 8.63 13.40 8.42 12.98 8.40 13.08 9.6 8.67 13.47 8.46 13.00 8.46 13.17 13.2 8.78 13.57 8.53 13.08 8.65 13.23 16.4 8.86 13.63 8.55 13.15 8.72 13.34 24.4 8.99 13.67 8.56 13.16 8.84 13.46 EVS-SWB 9.6 10.94 14.58 10.66 14.34 10.92 14.83 13.2 11.04 14.68 10.71 14.52 10.99 15.06 16.4 10.99 14.86 10.68 14.92 11.24 15.08 24.4 10.97 15.04 10.70 14.95 11.32 15.09 Page 3 of 8 1.2 For codecs with bit rate, tested only bit rate with the worst conversational gain Air Interface Band Limit (dB) Conv. Gain(dB) FR V1 FR V2 HR V1 AMR NB (4.75kbps) 2N 8N 2N 8N 2N 8N 2N 8N GSM 85…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ting Wang
[email protected]Fax: +8675536612000-81722

Technical Contact

TCT Mobile (US) Inc.Yao Dai
[email protected]

189 Technology Drive Ā· Irvine, 92618 Ā· United States

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd. ShKeny Xu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
215C2.41 GHz - 2.46 GHz95.30 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum combined conducted output power. SAR compliance for body-worn operating configurations is limited to or belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 1.0 cm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product-specific (wireless router) and simultaneous transmission exposure conditions are 0.31 W/kg, 0.37 W/kg, 0.37 W/kg and 1.58 W/kg, respectively. This device supports 20 and 40 MHz bandwidth modes. HAC-2019. Conversational gain values of 7.71 dB (2N with hearing aid) and 12.12 dB (8N without hearing aid). Certification under Waiver (DA 23-914).