Differences Declaration To whom concern, We company SEVEN LIKE CO., LIMITED hereby declares: The product models WS08, WS10, WS13, WS14, WS15, WS16 are identical in the same PCB layout, interior structure and electrical circuits, The differences are appearance color and model name for commercial purpose. Authorized signature: Date: 2020-07-28
Test model number: WS08
ºC/ºF 19.1mm 19.1mm
Test model number: WS08
FCC ID: 2ACD3-WS08 RF Exposure Evaluation According to KDB 447498 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison Here, For BT Max Power(dBm) Max Power(mW) Frequency(MHz) Min. distance(mm) Calc. thresholds limit -2.504 0.56 2440 5 0.175 3.0 So a SAR test is not required
Global United Technology Services Co., Ltd. Report No.: GTS202007000139F01 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 31 Test Report (Bluetooth) Applicant: SEVEN LIKE CO., LIMITED Address of Applicant: RM3128, Nanguang Jiejia Bldg., Futian District, Shenzhen, Guangdong, P.R.C. Manufacturer/Factory: SEVEN LIKE CO., LIMITED Address of Manufacturer/Factory: RM3128, Nanguang Jiejia Bldg., Futian District, Shenzhen, Guangdong, P.R.C. Equipment Under Test (EUT) Product Name: Smart Hygrometer Model No.: WS08, WS10, WS13, WS14, WS15, WS16 FCC ID: 2ACD3-WS08 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: July 15, 2020 Date of Test: July 15-20, 2020 Date of report issued: July 20, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202007000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 31 2 Version Version No. Date Description 00 July 20, 2020 Original Prepared By: Date: July 20, 2020 Project Engineer Check By: Date: July 20, 2020 Reviewer Report No.: GTS202007000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 31 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED OUTPUT POWER ........................................................................................................... 11 7.3 CHANNEL BANDWIDTH ...................................................................................................................... 13 7.4 POWER SPECTRAL DENSITY ............................................................................................................. 15 7.5 BAND EDGES .................................................................................................................................... 17 7.5.1 Conducted Emission Method ..................................................................................................... 17 7.5.2 Radiated Emission Method ........................................................................................................ 18 7.6 SPURIOUS EMISSION ......................................................................................................................... 21 7.6.1 Conducted Emission Method ..................................................................................................... 21 7.6.2 Radiated Emission Method ........................................................................................................ 23 8 TEST SETUP PHOTO ............................................................................................................................ 31 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 31 Report No.: GTS202007000139F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102…
Text truncated - open the document above for the full version.
Test model number: WS08 Radiated Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 560.00 µW |

Wireless Bluetooth Thermometer
Equipment Class
DTS - Digital Transmission System
Wireless Bluetooth Thermometer
Equipment Class
DTS - Digital Transmission System