Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ST User guide English User guide i ENGLISH Contents Welcome ........................................................................................................................................... 1 Indications for use ...................................................................................................................... 1 Contraindications ........................................................................................................................ 1 Adverse effects .......................................................................................................................... 2 Software functionality and device data ............................................................................................ 3 About your device ............................................................................................................................. 5 Setting up your device ...................................................................................................................... 6 Performing a functional check .......................................................................................................... 8 Navigating the touch screen ............................................................................................................. 9 Additional features ................................................................................................................... 10 Connecting your AirCurve 11 device and smart device .......................................................... 11 Starting/Stopping therapy .............................................................................................................. 12 About the heated tubing ................................................................................................................. 13 Therapy data ................................................................................................................................... 14 Cleaning and caring for the device ................................................................................................. 16 Disassembling .......................................................................................................................... 17 Cleaning .................................................................................................................................... 17 Checking ................................................................................................................................... 18 Replacing the air filter .............................................................................................................. 18 Reassembling ........................................................................................................................... 18 Traveling ......................................................................................................................................... 19 Traveling by plane..................................................................................................................... 19 Troubleshooting.............................................................................................................................. 20 General warnings ............................................................................................................................ 22 Technical specifications .................................................................................................................. 23 Symbols .......................................................................................................................................... 29 Servicing ......................................................................................................................................... 30 Limited warranty ............................................................................................................................. 30 Further information......................................................................................................................... 31 ii Quick setup view Components 1. HumidAir™ tub 2. AirCurve™ 11 device 3. Device identification plaque (eg, AirCurve 11 VAuto, AirCurve 11 VPAP ST, AirCurve 11 S, AirCurve 11 ASV) 4. Power Supply unit 5. ClimateLineAir™ 11 tubing 6. Mask English 1 Welcome The AirCurve 11 VAuto, AirCurve 11 S and AirCurve 11 ST devices are bi-level positive airway pressure devices. The AirCurve 11 ASV is a positive airway pressure devices that belong to the adaptive servo- ventilator category. WARNING • Read this entire guide before using the device. • This device is not suitable for ventilator-dependent patients. • Before putting patients on ASV, each patient should be assessed for heart failure. In case of signs and symptoms of heart failure an objective assessment of LVEF should be performed. CAUTION In the US, Federal law restricts this device to sale by or on the order of a physician. Indications for use AirCurve 11 VAuto The AirCurve 11 VAuto system is indicated for the treatment of Obstructive Sleep Apnea (OSA) in patients weighing more than 66 lb/ 30 kg. The AirCurve 11 VAuto S system is intended for use in the hospital and home. AirCurve 11 S The AirCurve 11 S system is indicated for the treatment of Obstructive Sleep Apnea (OSA) in patients weighing more than 66 lb/ 30 kg. The AirCurve 11 VAuto S system is intended for use in the hospital and home. AirCurve 11 ST The AirCurve 11 ST system is indicated for the treatment of Obstructive Sleep Apnea (OSA) in patients weighing more than 66 lb/ 30 kg. The AirCurve 11 ST system is intended for use in the hospital and home. AirCurve 11 ASV The AirCurve 11 ASV system i s indicated for the treatment of Obstructive Sleep Apnea (OSA) in patients weighing more than 66 lb/ 30 kg. ASV and ASVAuto modes are also indicated for the treatment of central and/or mixed apneas, or …
Text truncated - open the document above for the full version.
ResMed Pty Ltd 1 Elizabeth Macarthur Drive, Bella Vista NSW 2153, Australia T +61 2 8884 1000 E [email protected] ResMed.com Date: 18 May 2022 DECLARATION OF EQUIVALENCE This document declares that the following designated products are equivalent to the unit under test 39428. For USA: Model Name / Product Code Marketing Name 39491 AIRCURVE 11 ASV USA 39492 AIRCURVE 11 S USA 39493 AIRCURVE 11 ST USA 39494 AIRCURVE 11 VAUTO USA For Canada: Model Name / Product Code Marketing Name 39495 AIRCURVE 11 VAUTO CAN 39496 AIRCURVE 11 S CAN 39497 AIRCURVE 11 ST CAN 39498 AIRCURVE 11 ASV CAN For USA & Canada: Model Name / Product Code Marketing Name 51400 AIRCURVE 11 ST NORTH AMERICA All the above stated products have the same hardware, cellular firmware and Bluetooth firmware. Different models are derived for marketing purposes. The differences between S, ST, VAuto and ASV models are the therapy modes and customer/region centric features supported by the device. These settings are configured at manufacturing via a configuration file and is independent of the cellular, Bluetooth and FG software. In summary, the differences between the device models mentioned herein are: • Therapy modes • Data settings • UI language • Name plaque • Data connection parameters. ResMed Pty Ltd 1 Elizabeth Macarthur Drive, Bella Vista NSW 2153, Australia T +61 2 8884 1000 E [email protected] ResMed.com Applicant: Company Name: ResMed Pty Ltd Address: 1 Elizabeth Macarthur Drive, Bella Vista NSW 2153 Australia By, ______________________ Christopher Jenkins Title: Associate Manager – Systems Engineering Company: ResMed Pty Ltd Telephone: +61 2 8884 1517 e-mail: [email protected]
ResMed Pty Limited 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia T +61 (2) 8884 1517 [email protected] ABN 30 003 765 142 ResMed.com Date: May 18, 2022 Re: Declaration about validity of test results from testing/certification of the previous model We, ResMed Pty Ltd, 1 Elizabeth Macarthur Dr, Bella Vista NSW 2153, Australia Related to product: Type of Equipment: Bilevel device with integrated cellular and Bluetooth connectivity Brand name: ResMed Model name: 39491, 39492, 39493, 39494, 39495, 39496, 39497, 39498, 51400 Commercial name: AIRCURVE 11 VAUTO, AIRCURVE 11 S, AIRCURVE 11 ST, AIRCURVE 11 ASV FCC ID: 2ACHL-AIR11M1B IC: 9103A-AIR11M1B To whom it may concern, We declare that the model 39001 with the FCC ID: 2ACHL-AIR11M1 and IC: 9103A-AIR11M1 and the model 39428 support the same module BLE and the same cellular module as it can be confirmed with the electrical diagram and list of materials sent with along this declaration. Then, the results from conducted test according to FCC and ISED standards remain applicable, valid and representative for the certification of the host device, AirCurve 11 Test report Number Test Standards Date of Issue 70437RRF.002A1 USA FCC Part 15.247, 15.209 CANADA RSS-247, RSS-Gen 2022-05-06 70437RRF.004 USA FCC Part 22 & Part 90 CANADA RSS-132, RSS-Gen 2022-05-06 Sincerely, __________________________ By: Christopher Jenkins Title: Associate Manager – Systems Engineering Company: ResMed Pty Ltd Telephone: +61 2 8884 1517 e-mail: [email protected]
ResMed Pty Ltd 1 Elizabeth Macarthur Drive, Bella Vista NSW 2153, Australia T +61 2 8884 1000 E [email protected] ResMed.com Date: 05-Apr-22 Federal Communications Commission Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21048 Ref: Confidentiality request for FCC ID: 2ACHL-AIR11M1B To whom it may concern: Pursuant to §0.457(d)(1)(ii) and §0.459 of the Commission’s Rules (47 C.F.R.) and §552 (b)(4) of the Freedom of Information Act, ResMed Pty Ltd hereby request requests that a part of the subject FCC application be held confidential to avoid release of sensitive information of the product to the public. For the product stated above, we request that the following information be withheld from public disclose: Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Internal Photos Short Term Permanent Operation Description Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term User’s Manual Permanent Confidentiality: The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to us and provide unjustified benefits to our competitors. Short-Term Confidentiality: We hereby request short-term confidentiality for the product stated above to avoid premature release of sensitive information prior to marketing or release of the product to the public. Release date of short term confidentiality is: 45 days from grant date marked 90 days from grant date marked 135 days from grant date marked 180 days from grant date marked Specific date: We are also aware that we are responsible to notify DEKRA in the event information regarding the product or the product is made available to the public. DEKRA will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, _________________________ By: Christopher Jenkins Title: Associate Manager – Systems Engineering Company: ResMed Pty Ltd Telephone: +61 2 8884 1000 e-mail: [email protected]
ResMed Pty Limited 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia T +61 (2) 8884 1517 E [email protected] ABN 30 003 765 142 ResMed.com Federal Communications Commission Equipment Authorization Division 7435 Oakland Mills Road Columbia, MD 21048 Date: 5 April 2022 Ref: Agent letter for FCC ID: 2ACHL-AIR11M1B We, ResMed Pty Ltd, 1 Elizabeth Macarthur Dr, Bella Vista NSW 2153, Australia hereby authorize DEKRA Testing and Certification, S.A.U., C/ Severo Ochoa, 2 & 6, 29590 Campanillas Málaga, Spain Mr. Mario Baudet Aranda, e-mail: [email protected], Phone: +34 952 61 93 71 to act as our agent in the preparation of this application for equipment certification, including the signing of all documents relating to these matters. The present authorization considers the development of documents on behalf of the client, written under the client’s letterhead and related to the necessary information to be provided on the client’s behalf to complete the certification process. We also hereby certify that neither we nor any party to this application are subject to a denial of U.S. Federal benefits, which include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862 because of conviction for possession or distribution of controlled substance. For instances where our authorized agent signs the application for certification on our behalf, we acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by DEKRA Testing and Certification, S.A.U., still resides with us. This agreement expires one year from the current date. Sincerely, __________________________ By: Christopher Jenkins Title: Associate Manager – Systems Engineering Company: ResMed Pty Ltd Telephone: +61 2 8884 1517 e-mail: [email protected]
AIRCURVE 11 EXTERNAL PHOTOGRAPHS for PACIFIC project ResMed Confidential Proprietary Information, not to be reproduced or made available to third parties without prior consent from ResMed and not to be used in any unauthorised way. ResMed Ltd 2022 Date last saved: 6-Apr-22 Objective id: A5162399 Page 1 of 5 Title: AIRCURVE 11 EXTERNAL PHOTOGRAPHS Project/Product PACIFIC AIRCURVE 11 EXTERNAL PHOTOGRAPHS for PACIFIC project Company Confidential Date last saved: 6-Apr-22 Objective id: A5162399 Page 2 of 5 1. Purpose This document contains the external photographs for the Pacific Project, and is applicable to the following device models: Model Name / Product Code Marketing Name 39491 AIRCURVE 11 ASV USA 39492 AIRCURVE 11 S USA 39493 AIRCURVE 11 ST USA 39494 AIRCURVE 11 VAUTO USA 39495 AIRCURVE 11 VAUTO CAN 39496 AIRCURVE 11 S CAN 39497 AIRCURVE 11 ST CAN 39498 AIRCURVE 11 ASV CAN 51400 AIRCURVE 11 ST NORTH AMERICA 2. External Photographs View Photographs Front View AIRCURVE 11 EXTERNAL PHOTOGRAPHS for PACIFIC project Company Confidential Date last saved: 6-Apr-22 Objective id: A5162399 Page 3 of 5 View Photographs Rear View Left Side View AIRCURVE 11 EXTERNAL PHOTOGRAPHS for PACIFIC project Company Confidential Date last saved: 6-Apr-22 Objective id: A5162399 Page 4 of 5 View Photographs Right Side View Top View AIRCURVE 11 EXTERNAL PHOTOGRAPHS for PACIFIC project Company Confidential Date last saved: 6-Apr-22 Objective id: A5162399 Page 5 of 5 View Photographs Bottom View
Black Artwork 1 This box = 40mm x 4mm CODES: COLOURS: PAGE REV SPEC NO. ResMed Confidential Proprietary Information, not to be reproduced or made available to third parties without prior consent from ResMed and not to be used in any unauthorised way. © 2022 ResMed.. SPECIFICATION NOTES: 1. Scale 1:1 (A3) 2.Dimensions in mm 3. GENERAL TOLERANCES (unless otherwise stated) - Linear Dimenions +/- 0.25mm O - Angular Dimensions +/- 0.5 - Printing tolerance between colours +/- 0.25mm - Graphics registration with part +/- 0.4mm OF 1 1.0 R390-432 Rev CN No. Date Drafted Details Drawn By Checked By 1.0 K010094-00 21 Jan 2022 Initial Release of Specification Melanie Webster Annick De Silva Label - SN Air11 Bilevel AMER 1. Scope: This specification defines the Blank Label, the Artwork, the Ink Ribbon and the Master Spec to be used for printing the Label - SN Air11 Bilevel AMER, and is for reference and (where specified) positioning purposes only. 2. Requirement Only the specified Ink Ribbon & Blank Label materials shall be used on this label, in order to ensure compliance to the durability requirements for mandatory product information (text and symbols). NOTE: Any changes to this specification MUST be reviewed by the IT Department 3. Blank Label For all label requirements, refer to the latest revision of R390-404 Label - SN 80x25 Silver (Blank) 4. Artwork File: For the artwork, use the CodeSoft “R390-432.001.lab” file. 5. Ink Ribbon For all ink ribbon requirements, refer to the latest revision of Z9467 Thermal Print Ribbon 6. Master Specification: For all other printing information, refer to the latest revision of R390-405 Master Spec - Label-SN Printing 7. Unique Device Identifier: For UDI labelling information, refer to R001-341 Barcode Labels – UDI 2D. DRAFT - NOT AN APPROVED RELEASE
AIRCURVE 11 INTERNAL PHOTOGRAPHS for PACIFIC project ResMed Confidential Proprietary Information, not to be reproduced or made available to third parties without prior consent from ResMed and not to be used in any unauthorised way. ResMed Ltd 2022 Date last saved: 6-Apr-22 Objective id: A5162400 Page 1 of 3 Title: AIRCURVE 11 INTERNAL PHOTOGRAPHS Project/Product PACIFIC AIRCURVE 11 INTERNAL PHOTOGRAPHS for PACIFIC project Company Confidential Date last saved: 6-Apr-22 Objective id: A5162400 Page 2 of 3 1. Purpose This document contains the internal photographs of the PCBA for the Pacific Project, and is applicable to the following device models: Model Name / Product Code Marketing Name 39491 AIRCURVE 11 ASV USA 39492 AIRCURVE 11 S USA 39493 AIRCURVE 11 ST USA 39494 AIRCURVE 11 VAUTO USA 39495 AIRCURVE 11 VAUTO CAN 39496 AIRCURVE 11 S CAN 39497 AIRCURVE 11 ST CAN 39498 AIRCURVE 11 ASV CAN 51400 AIRCURVE 11 ST NORTH AMERICA 2. Internal Photographs View Photograph PCBA Top View AIRCURVE 11 INTERNAL PHOTOGRAPHS for PACIFIC project Company Confidential Date last saved: 6-Apr-22 Objective id: A5162400 Page 3 of 3 View Photograph PCBA Bottom View Cellular Module Page 1 of 2 FCC ID: QIPEXS62-W IC: 7830A-EXS62W Shenzhen UnionTrust Quality and Technology Co., Ltd. Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China Tel: +86-755-28230888 Fax: +86-755-28230886 E-mail: [email protected]://www.uttlab.com APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS EUT PHOTOS EUT Photo EUT Photo Page 2 of 2 FCC ID: QIPEXS62-W IC: 7830A-EXS62W Shenzhen UnionTrust Quality and Technology Co., Ltd. Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China Tel: +86-755-28230888 Fax: +86-755-28230886 E-mail: [email protected]://www.uttlab.com EUT Photo(ESIM) EUT Photo(ESIM)
DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report Nº: (NIE) 70437RAN.003 2022-03-16 Test report No: NIE: 70437RAN.003 Test report IEEE Std 1528™-2013 (*) Identification of item tested AirCurve 11 (*) Trademark ResMed (*) Model and /or type reference 39428 AirCurve 11 (*) Derived model not tested For USA: AirCurve 11 ASV (39491), AirCurve 11 S (39492), AirCurve 11 ST (39493), AirCurve 11 V Auto (39494), For Canada: AirCurve 11 VAuto (39495), AirCurve 11 S (39496), AirCurve 11 ST (39497), AirCurve 11 ASV (39498). For USA & Canada: AirCurve 11 ST (51400) (*) Other identification of the product HW Version: 1.0 SW Version: SW04600 FCC ID: 2ACHL-AIR11M1B IC: 9103A-AIR11M1B (*) Features LTE Cat-M1, BLE Applicant RESMED Pty Ltd 1 Elizabeth Macarthur Drive, BELLA VISTA, NSW, 2153, AUSTRALIA Test method requested, standard 1. IEEE Std 1528 TM -2013: Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques. 2. FCC 47 CFR Part 2.1093. (10-1-15 Edition) Radiofrequency radiation exposure evaluation: portable devices. Summary Considering the results of the performed test, the item under test is IN COMPLIANCE with FCC 47CFR Part 2.1093 exposure limits. The maximum 1-g SAR found during this test has been 0.077 W/kg, for LTE CAT M1 Band 66. Approved by (name / position & signature) Rafael López EMC Consumer & RF Lab. Manager Date of issue 2022-03-16 Report template No FDT08_23 (*) “Data provided by the client” DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 2 of 161 2022-03-16 Index Competences and guarantees .................................................................................................... 3 General conditions ...................................................................................................................... 3 Uncertainty ................................................................................................................................. 3 Data provided by the client .......................................................................................................... 3 Usage of samples ....................................................................................................................... 5 Test sample description .............................................................................................................. 5 Identification of the client............................................................................................................. 5 Testing period and place ............................................................................................................. 6 Document history ........................................................................................................................ 6 Environmental conditions ............................................................................................................ 6 Remarks and comments ............................................................................................................. 6 Testing verdicts ........................................................................................................................... 8 Summary .................................................................................................................................... 8 Appendix A: Test configuration ................................................................................................... 9 Appendix B: Test results ........................................................................................................... 18 Appendix C: Measurement Reports .......................................................................................... 55 Appendix D: System Validation Reports .................................................................................... 68 Appendix E: Calibration data ..................................................................................................... 77 Appendix F: Photographs........................................................................................................ 157 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 3 of 161 2022-03-16 Competences and guarantees DEKRA Testing and Certification S.A.U. is a testing laboratory accredited by the National Accreditation Body (ENAC -Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147. DEKRA Testing and Certification is a FCC-recognized accredited testing laboratory with appropriate scope of accreditation that include testing performed in this test report. In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification S.A.U. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification at the time of performance of the test. DEKRA Testing and Certification S.A.U. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be repro…
Text truncated - open the document above for the full version.
DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 77 of 161 2022-03-16 Appendix E: Calibration data DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 78 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 79 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 80 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 81 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 82 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 83 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 84 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 85 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 86 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 87 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 88 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 89 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 90 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 91 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 92 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 93 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 94 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 95 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 96 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 97 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 98 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 99 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 100 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 101 of 161 2022-03-16 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 70437RAN.003 Page 102 of 161 2022-03-16 DEKRA Testing and C…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 4 | 15B | 859 MHz - 894 MHz | - |
NIV Device with Integrated Cellular and Bluetooth Connectivity
Equipment Class
JAB - Part 15 Class B Digital Device
Continuous Positive Airway Pressure (CPAP) Device
Equipment Class
JAB - Part 15 Class B Digital Device
Continuous Positive Airway Pressure (CPAP) Device
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBs
Continuous Positive Airway Pressure (CPAP) Device
Equipment Class
PCB - PCS Licensed Transmitter
Wireless Continuous Positive Airway Pressure Device
Equipment Class
PCB - PCS Licensed Transmitter