Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER MANUAL Flic Hub / English Flic Hub LR GETTING STARTED To get started make sure that you have: 1. An active internet connection (Wifi or Ethernet) 2. A phone with the Flic app installed 3. A Flic button within Bluetooth range of the Hub The phone is only necessary during the setup process. Once the Hub and Flic are connected you no longer need the phone app to be running to enjoy Flic! POWER Connect the Micro USB cable to the Hub and an external power adapter. The Hub will now turn on, indicated by a bright red LED. After approximately 60 seconds the LED will dim, indicating that it can now be found using the Flic App on your phone. Follow the setup and start connecting your Flic buttons. We recommend that you use an adapter can supply the Hub with at least 1A. If using an adaptor with less than the recommended current rating you may experience unstable behaviour. If using the IR you must ensure that you have a 1A current supply. INTERNET CONNECTION To connect the Hub to your Wifi network open the Flic App and follow the setup steps to get the Hub connected to the internet. Alternatively you can simply connect the Hub, via an ethernet cable, directly into your home router/network. If the Hub doesn’t have an acitve internet connection you will not be able to connect any Flic buttons. To check if the internet connection for the Hub is active you should open the Hub settings page. Look for the network settings section and press test. PAIRING YOUR FLIC BUTTONS If you are pairing a brand new Flic button to the Hub for the first time then simply tap the ‘+’ button in the bottom right corner of the Hub app page. You will be prompted to press the Flic button and the pairing should take a few seconds. Alternatively, if you are pairing a Flic button that was previously paired to another device or Hub then you will need to remove it from that device first. You can do this by tapping the gear (settings) icon and selecting the ‘Remove’ option. You can now pair this button as described above. Remember that you must have an active internet connection to pair! INFRARED ACCESSORY Connect your Flic IR accessory to the Hub via the 2.5mm connector and place the IR blaster in general the direction of the recieving device(s). The range of the IR is ~10m. For best results ensure clear line of sight between IR accessory and recieving device. To setup your first action simply select the IR Blaster action within the Flic app. Follow the in app instructions to start recording IR signals from all your remotes! INFRARED ACCESSORY INFRARED ACCESSORY The Flic IR accessory uses the same reusable adhesive as the Flic button. Once you have all your actions setup you can simply peel away the label and secure the IR blaster in the best location to serve all your devices. If the adhesive starts to loose its stickiness then you can clean it • Remove it from the IR base and rinse with water. • Give it a rub and rinse again. • Leave it to air-dry and it will return to full stickiness. Do not apply solvents, chemicals or abrasive cleaning products as this will damage the adhesive. AUDIO Connect the Flic Hub to any speaker via the 3.5mm audio jack connector. This allows for the Hub to play a sound as feedback to know that a Flic button has been pressed. FACTORY RESET If, for any reason, you must perform a factory reset you need to press the pinhole button for between 10-15 seconds. All your account settings will be lost and the Hub will return to default. If you remove the Hub from your account and reconnect to it then you will be prompted to use the Factory Password when pairing. This can be found on the label on the underside of your Hub. Alternatively, if during the intial setup you assign your own Hub password and forget this then you must perform a factory reset to gain access again. PROBLEMS If you have any further issues setting up or using your Hub and/or Flic buttons that are not answered here then please read through our full FAQ’s. They can be found at https://start.flic.io/faq Alternatively you can contact us via the in-app customer support or email us at [email protected] COMPLIANCE Shortcut Labs declaration of conformity is available at https://flic.io/doc For a full compliance list visit https://flic.io/compliance Flic is certified as FCC, IC, CE, TELEC, WEEE, RoHS, REACH, AUS and R-NZ compliant. The Flic Hub is certified as FCC, IC, CE, WEEE, RoHS and REACH compliant. SAFETY USAGE GUIDELINES The Flic Hub and Flic are not toys. They contain small parts and accessories that present a choking hazard. As such they are not suitable for children or pets. General • Do not attempt to service the product. • Do not use the product in temperatures below -20°C or above +54 °C. • Clean with a damp cloth only. Do not submerge and do not use chemical or abrasive cleaning products. Flic specific • Battery life will be shortened with heavy usage and/or use in extreme conditions. • Flic is rated as splash proof only - IP44. Do not submerge or attempt to use underwater as this will result in irreversible damage that is outside the scope of the Shortcut Labs AB warranty. Shortcut Labs AB warrants that your Flic hardware product (“the product”) will be free from defects in materials and workmanship for a period of 24 months from the date of delivery to the original retail purchaser (“the warranty period”). If a defect in the product arises within the warranty period, Shortcut Labs will, at its sole option and subject to applicable laws: (a)repair or replace it with a new or refurbished product or component; or (b)refund the original purchase price upon return of the defective product. This warranty does not apply to products you purchase from unauthorized resellers, or where the instructions for use and activation of the product are not complied with or where the product is damaged as a result of abuse, accident, modification, moisture or other causes beyond our reasonable control. For detailed warranty information visit: …
Text truncated - open the document above for the full version.
Shortcut Labs AB Drottning Kristinas Vag 41 Stockholm Sweden 11428 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 2019-10-212019-10-21 To whom it may concern: We, the undersigned, hereby authorize Worldwide Testing Services (Taiwan) Co., Ltd to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2ACR9-HUBLR including the signing of all documents related to these matters. Any and all acts carried out by Worldwide Testing Services (Taiwan) Co., Ltd on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Signature Name: Amir Sharifat Title: COO Company: Shortcut Labs AB
Shortcut Labs AB Drottning Kristinas Vag 41 Stockholm Sweden 11428 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 2019-12-17 Request for Long-Term Confidentiality Company name: Shortcut Labs AB FCC ID: 2ACR9-HUBLR FCC Part 15 Certification To whom it may concern: In accordance with 0.457(d) and 0.459 of CFR 47, Shortcut Labs AB hereby requests Long-Term confidentiality of all Block Diagrams, Schematics, Operational Description attachments for the subject application. These documents contain detailed system and equipment description and related information about the product which Shortcut Labs AB considers to be proprietary, confidential and a custom design and otherwise would not release to the general public. Since the design is a basis from which future technological products will evolve, Shortcut Labs AB considers that this information would be of benefit to its competitors and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Sincerely, Signature Name: Amir Sharifat Title: COO Company: Shortcut Labs AB
Shortcut Labs AB Drottning Kristinas Vag 41 Stockholm Sweden 11428 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 2019-10-21 Attention: Equipment Authorization Branch REQUEST FOR SHORT-TERM CONFIDENTIALITY Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), Shortcut Labs AB hereby requests short term confidential treatment of some of the information accompanying the application of FCC ID: 2ACR9- HUBLR and as outlined as below: Type of Confidentiality Requested Exhibit Short Term (Up to 180 days) External Photos Short Term (Up to 180 days) Internal Photos Short Term (Up to 180 days) Test Setup Photos Short Term (Up to 180 days) User’s Manual These documents contain detailed system and equipment description and related information about the product which Shortcut Labs AB considers to be proprietary and confidential. The early public disclosure of these documents might be harmful to Shortcut Labs AB and provide unjustified benefits to its competitors. Sincerely, Signature Name: Amir Sharifat Title: COO Company: Shortcut Labs AB
Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 16 External Photos Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 16 Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 16 Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 16 Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 16 Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 16 Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 8 of 16
Flic Hub LR 標籤位置:貼在方形空位
Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 9 of 16 Internal Photos Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 10 of 16 Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 11 of 16
Shortcut Labs AB Drottning Kristinas Vag 41 Stockholm Sweden 11428 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Applicant’s declaration concerning RF Radiation Exposure We hereby indicate that the product Product description: Flic Hub LR Model No: Hub LR The equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The integral antennas used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter within the host device. A safety statement concerning minimum separation distances from enclosure of the Product : Flic Hub LR will be integrated in the user’s manual to provide end-users with transmitter operating conditions for satisfying RF exposure compliance. The appropriate information can be drawn from the test report no: W6M21906-19172-C-1, W6M21906-19172-C-7and the accompanying calculations. Company: Shortcut Labs AB Address: Drottning Kristinas Vag 41 Stockholm Sweden 11428 Date: 2019-10-21 Signature Registration number: W6M21906-19172-C-1 FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Page 22 of 54 3.2 Equivalent isotropic radiated power FCC Rule: 15.247(b)(3) WLAN EIRP = max. conducted output power + antenna gain EIRP = 16.34 dBm + (4.6 dBi) = 20.94 dBm = 124.1652 mW BLE EIRP = max. conducted output power + antenna gain EIRP = 3.99 dBm + (3.4 dBi) = 7.39 dBm = 5.4828 mW Test equipment used: ETSTW-RE 055 3.3 Exemption Limits for Routine Evaluation according to 47 CFR FCC Part 2 Subpart J, section 2.1091 FCC OET Bulletin 65 Edition 97.01 determines the equations for predicting RF fields and applicable limits. The prediction for power density in the far-field but will over-predict power density in the near field, where it could be used for walking a “worst case” or conservative prediction. Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 20 cm normally can be maintained between the user and the device. MPE Calculation Method Registration number: W6M21906-19172-C-1 FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Page 23 of 54 E = Electric field (V/m) P = output power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to mW/cm 2 . WLAN Established separation distance is 20 cm. Operating frequency band: 802.11b, g, n 20MHz: 2412-2462 MHz, 802.11n 40MHz: 2422-2452 MHz, The product meets RF exposure requirement. Because the power density of 0.0247 mW/cm 2 at 2412 MHz is below the power density limit of 1 mW/cm 2 . BLE Established separation distance is 20 cm. Operating frequency band: 2402-2480 MHz The product meets RF exposure requirement. Because the power density of 0.0011 mW/cm 2 at 2402 MHz is below the power density limit of 1 mW/cm 2 . Limits: Limit for General Population / Uncontrolled Exposure Frequency (MHz) Power Density (mW/cm 2 ) 1500 – 100.000 1.0 Registration number: W6M21906-19172-C-7 FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Page 79 of 89 3.6 Automatic Discontinuation of transmission, FCC 15.407 (c) The device shall automatically discontinue transmission in case of either absence of information to transmit or operational failure. This function will be declared by manufacturer. 3.7 Reserved, FCC 15.407 (d) 3.8 Indoor Operation Restriction, FCC 15.407 (e) Within the 5.15–5.25 GHz band, U- NII devices will be restricted to indoor operations to reduce any potential for harmful interference to co-channel MSS operations. This equipment has to be declared by manufacturer of the final product as content of the user manual. 3.9 Equivalent isotropic radiated power, FCC 15.407 (f) FCC Rule: 15.407(b)(3) EIRP= max. conducted output power + antenna gain EIRP=Band 1=Test exclusion=8.36 dBm+(1.5 dBi)=9.86 dBm=9.68 mW EIRP=Band 2=Test exclusion=9.03 dBm+(1.9 dBi)=10.93 dBm=12.39 mW EIRP=Band 3=Test exclusion=9.58 dBm+(2.1 dBi)=11.68 dBm=14.72 mW EIRP=Band 4=Test exclusion=8.87 dBm +(2.2 dBi)=11.07 dBm=12.79 mW Test equipment used: ETSTW-RE 055 3.10 Exemption Limits for Routine Evaluation according to 47 CFR FCC Part 2 Subpart J, section 2.1091 FCC OET Bulletin 65 Edition 97.01 determines the equations for predicting RF fields and applicable limits. The prediction for power density in the far-field but will over-predict power density in the near field, where it could be used for walking a “worst case” or conservative prediction. Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 20 cm normally can be maintained between the user and the device. Registration number: W6M21906-19172-C-7 FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Page 80 of 89 E = Electric field (V/m) P = output power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to mW/cm 2 . Band 1 Established separation distance is 20 cm. Operating frequency band: 5.15-5.25 MHz The product meets RF exposure requirement. Because the power density of 0.0019 mW/cm 2 at 5190 MHz is below the power density limit of 1mW/cm 2 . Band 2 Established separation distance is 20 cm. Operating frequency band: 5.25-5.35 MHz The product meets RF exposure requirement. Because the power density of 0.0025 mW/cm 2 at 5190 MHz is below the power density li…
Text truncated - open the document above for the full version.
of Applicant: Shortcut Labs AB Address: Drottning Kristinas väg 41, 114 28 Stockholm, Sweden Tested and Prepared by W orldwide Testing Services (Tai wan) Co., Ltd. FCC Registration No.: TW1477 , TW0020, TW1072 Industry Canada filed test laboratory Reg. No.: 20037 A2LA Accredited No.: 2732. 01 Report No.: W6M21906-19172-C-7 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] FCC PART 15 SUBPART E TEST REPORT for Flic Hub LR Model No.: Hub LR FCC ID: 2ACR9-HUBLR Registration number: W6M21906-19172-C-7 FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 89 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 NOTES .......................................................................................................................................... 2 1.2 TESTING LABORATORY ................................................................................................................ 3 1.2.1 Location .............................................................................................................................. 3 1.2.2 Details of accreditation status ............................................................................................ 3 1.3 D ETAILS OF APPROVAL HOLDER ................................................................................................... 3 1.4 APPLICATION DETAILS ................................................................................................................. 3 1.5 GENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.6 T EST STANDARDS ......................................................................................................................... 8 2 TECHNICAL TEST ......................................................................................................................... 9 2.1 SUMMARY OF TEST RESULTS ........................................................................................................ 9 2.2 T EST ENVIRONMENT .................................................................................................................... 9 2.3 T EST EQUIPMENT LIST ............................................................................................................... 10 2.4 TEST PROCEDURE ...................................................................................................................... 13 3 TEST RESULTS (ENCLOSURE) ................................................................................................ 16 3.1 P EAK TRANSMIT POWER, FCC 15.407 (A) ................................................................................. 17 3.2 26DB EMISSION BANDWIDTH, 99% OCCUPIED BANDWIDTH, FCC 15.407 (A) ........................... 37 3.3 6DB EMISSION BANDWIDTH, 99% OCCUPIED BANDWIDTH, FCC 15.407 (A) .............................. 52 3.4 PEAK POWER SPECTRAL DENSITY, FCC 15.407 (A) .................................................................. 57 3.5 U NDESIRABLE EMISSION LIMITS, FCC 15.407 (B) ...................................................................... 77 3.6 AUTOMATIC DISCONTINUATION OF TRANSMISSION, FCC 15.407 (C) ......................................... 79 3.7 RESERVED, FCC 15.407 (D) ....................................................................................................... 79 3.8 INDOOR OPERATION RESTRICTION, FCC 15.407 (E) .................................................................. 79 3.9 EQUIVALENT ISOTROPIC RADIATED POWER, FCC 15.407 (F) ..................................................... 79 3.10 EXEMPTION LIMITS FOR ROUTINE EVALUATION ACCORDING TO 47 CFR FCC PART 2 SUBPART J, SECTION 2.1091 .................................................................................................................. ... 79 3.11 TRANSMIT POWER CONTROL (TPC) .......................................................................................... 81 3.12 DYNAMIC FREQUENCY SELECTION (DFS) ................................................................................. 82 3.12.1 DFS Detection Threshold ................................................................................................. 82 3.12.2 Channel move time plot of Type1 radar waveform on 5270MHz ..................................... 84 3.12.3 30Minutes Non-Occupancy Time ...................................................................................... 85 3.13 C HANNEL MOVE TIME, CHANNEL CLOSING TRANSMISSION TIME ............................................. 86 3.14 RADIATED EMISSIONS FROM RECEIVER PART ............................................................................ 87 3.15 P OWER LINE CONDUCTED EMISSION ......................................................................................... 88 Registration number: W6M21906-19172-C-7 FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 89 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test …
Text truncated - open the document above for the full version.
Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 12 of 16 Set Up Photo of Radiated Emission EMI Below 1GHz Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 13 of 16 Above 1GHz Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 14 of 16 RF Below 1GHz Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 15 of 16 Above 1GHz Registration number: W6M21906-19172-FCC FCC ID: 2ACR9-HUBLR Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 16 of 16 Set Up Photo of Conducted Emission
6F., No.58, Lane 188, Ruiguang Rd., Neihu District · Taipei · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 12 | 15E | 5.78 GHz - 5.78 GHz | 6.67 mW |

Flic Twist with BLE
Equipment Class
DTS - Digital Transmission System
Bluetooth Low Energy Button
Equipment Class
DTS - Digital Transmission System