  1. Home/
  2. Honeywell Analytics Inc/
  3. 2ACSZVERTEXEDGE

2ACSZVERTEXEDGEVertex SF System

Honeywell Analytics Inc
Vertex SF System - FCC ID 2ACSZVERTEXEDGE - Honeywell Analytics Inc
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Aug 06, 2020
Application Purpose
Original Equipment
Date of Application
Aug 06, 2020
Equipment Note
Vertex SF System
Frequency Range
13.56000000 - 13.56000000
Company
Honeywell Analytics Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Vertex SF System 8 User Manual Safety Read this information before start using your device. About this Publication While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers. In no event is Honeywell liable to anyone for any indirect, special, or consequential damages. The information and specifications in this document are subject to change without notice. Trademarks Brand or product names are trademarks of their respective owners. The following brand or product names are trademarks of Honeywell: ⚫ Honeywell Vertex® SF ⚫ Chemcassette® General Safety Follow all installation and operational instructions to ensure the safe and reliable operation of this unit. If this monitor is used in a manner not specified by Honeywell Analytics Inc., the protection provided by the equipment may be impaired. EMC Considerations Your Honeywell Analytics continuous gas monitor has been designed to comply with applicable Electromagnetic Compatibility (EMC) standards at the time of manufacture. The design includes filtering, shielding and bypassing techniques. At the time of certification, simulated customer Input/ Output (I/O) schemes were tested. All methods used in your equipment for emission suppression and reduction of susceptibility are interactive. Modifications to the monitor could result in increased emissions and higher vulnerability to other radiated fields. Following the guidelines in this EMC Considerations section will ensure your monitor maintains the highest degree of EMC integrity. The guidelines listed apply only to I/O emissions and do not apply to A.C. and D.C. monitor power connections. FCC Compliance Statement CAUTION: Changes or modifications not expressly approved could void your authority to use this Vertex SF System 9 User Manual equipment. This device complies with Part 15 of the FCC Rules. Operation to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cau se undesired operation. Industry Canada Statement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage; (2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Vertex SF System 10 User Manual Cabling At a very minimum, all cables should include a braided shield. Ideal results have been obtained with twisted pair cabling which has a foil shield surrounding each pair plus foil and 90% braid shielding around the bundle. In addition, ensure local electrical code requirements are met. The following cable parameters must be considered: Braid Must have a minimum 90% coverage Foil When used with braid, provides 100% coverage. Do not use foil alone. It has a tendency to break. Twisted Pair Provides for cancelling of magnetic fields Stranded Pair Provides the greatest surface area Shield Termination Continuation of the shield to the cabinet earth ground is most important. For discrete wire terminations, pigtails to the cabinet (connector) ground should be extremely short (absolutely no greater than three inches). For multiconductor connector terminations, only 360° shielded shells should be used. Note: Honeywell Analytics product testing uses >90% braid with foil (around the bundle); twisted pair; stranded 24 AWG (minimum wiring for all qualification and certification testing.) Connectors All qualification and certification of Honeywell Analytics products were achieved with high quality connectors, providing 360° shield coverage. These connectors generally had metal shells. Failure to properly secure the connector to the equipment will result in high emission levels. Also, poorly constructed or improperly assembled connectors can be a high source of radiated noise and provide a path for external signals into the monitor. Vertex SF System 11 User Manual Introduction Learn what you need to know about the Honeywell Vertex® SF Continuous Monitor System before operating. System Overview The Honeywell Analytics Vertex SF™ System continuously monitors for toxic gases. It responds to gases that exceed programmed levels by: ⚫ Triggering alarms and opening event windows to warn operators of high or low concentrations ⚫ Triggering relays to external devices ⚫ Displaying the location, gas type and gas concentration ⚫ Storing the alarm information in a database The Vertex SF System provides fast response to a wide range of gases. Each location may be up to 400 ft (122 m) from the Vertex SF System. The system uses one or more of Honeywell Analytics’ Chemcassette® analyzers, with or without pyrolyzer, to provide a monitoring system tailored to meet the requirements of the facility. The Vertex SF System incorporates a range of redundant and protective features for maximum uptime: ⚫ Intelligent analyzer modules allow one to stop monitoring with no effect on the remaining modules ⚫ Power supplies are redundant ⚫ The system powers up in the same state as when powered down ⚫ Filters, Chemcassettes® and major components in one of the analyzers can be replaced while the remaining analyzers continue to function. …

Text truncated - open the document above for the full version.

Cover Letter(s)

Sr Advanced Quality Engineer

Cover Letter(s)

Honeywell Analytics, Inc. Date: 16 th of Ju ly, 2020 Federal Communications Commission 7 435 Oakland Mills Road Columbia MD 21046 c.c. UL Verification Services Inc. (formerly UL CCS) Certification Division 4717 3 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby autho rize UL-Korea and hereafter referred to as ULK, to act on our behalf in all manners relating to application for equipment authorization, includ ing signing of all documents relating to these matters. Any and all acts carried out by UL-Korea on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC ben efits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853 (a). In authorizing ULK as our agent , we still recognize that we are responsible to: a)comply with the relevant provisions of the certification program; b)make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c)make claims regarding certification only in respect of the scope for which certification has been granted; d)do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e)upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f)use certification only to indicate the products are certified as being in conformity with specified standards; g)endeavor to ensure that no certificate or report nor any part thereof is used in a misleading m anner; h)ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i)keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j)take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k)document the actions taken. Thi s authorization is valid until further written notice from the applicant. Sincerely Yours, By Ryan (Kyeonghwan) Kim Quality Engineer Honeywell Analytics, Inc. REMARK: 1.This authorization letter will be sent along with your application when filing with the Certification Division. 2.Please follow the format and type it on company letterhead and send original to us. 3.Authorized signature must be in agreement with grantee code contact in FCC database.

External Photos

FCC ID : 2ACSZVERTEXEDGE Page : 1 of 3 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 EXTERNAL PHOTOS OF EUT Top view of EUT Bottom view of EUT FCC ID : 2ACSZVERTEXEDGE Page : 2 of 3 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Front view of EUT Rear view of EUT FCC ID : 2ACSZVERTEXEDGE Page : 3 of 3 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Left side of EUT Right side of EUT

ID Label/Location Info

Label Location FCC ID : 2ACSZVERTEXEDGE IC: 12190A-VERTEXEDGE

Internal Photos

FCC ID : 2ACSZVERTEXEDGE Page : 1 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 INTERNEL PHOTOS OF EUT EUT case open FCC ID : 2ACSZVERTEXEDGE Page : 2 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Main Board front side Main Board rear side FCC ID : 2ACSZVERTEXEDGE Page : 3 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Encoder Board front side Encoder Board rear side FCC ID : 2ACSZVERTEXEDGE Page : 4 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Flow Sensing Board front side Flow Sensing Board rear side FCC ID : 2ACSZVERTEXEDGE Page : 5 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Hall Effect Board front side Hall Effect Board rear side FCC ID : 2ACSZVERTEXEDGE Page : 6 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Optic Board_1 front side Optic Board_1 rear side FCC ID : 2ACSZVERTEXEDGE Page : 7 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Optic Board_2 front side Optic Board_2 rear side FCC ID : 2ACSZVERTEXEDGE Page : 8 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Status Indicator Board front side Status Indicator Board rear side FCC ID : 2ACSZVERTEXEDGE Page : 9 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Tranceducer Board_1 front side Tranceducer Board_1 rear side FCC ID : 2ACSZVERTEXEDGE Page : 10 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 Tranceducer Board_2 front side Tranceducer Board_2 rear side FCC ID : 2ACSZVERTEXEDGE Page : 11 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 RFID Board front side RFID Board rear side FCC ID : 2ACSZVERTEXEDGE Page : 12 of 12 IC Num : 12190A-VERTEXEDGE UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 RFID Antenna

Test Report

Testing Laboratory TL-637 CERTIFICATION TEST REPORT Report Number. : 4789458470-FR1V3 Applicant : Honeywell Analytics Inc 405 Barclay Blvd, Lincolnshire, Illinois, 60069, United States Model : Vertex Edge Analyzer FCC ID : 2ACSZVERTEXEDGE IC : 12190A-VERTEXEDGE EUT Description : NFC Test Standard(s) : FCC 47 CFR PART 15 SUBPART C ISED RSS-210 ISSUE 10 ISED RSS-GEN ISSUE 5 Date Of Issue: August 07, 2020 Prepared by: UL Korea, Ltd. 26th floor, 152, Teheran-ro, Gangnam-gu Seoul, 06236, Korea Suwon Test Site: UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 REPORT NO: 4789458470-FR1V3 DATE: AUG 07, 2020 FCC ID: 2ACSZVERTEXEDGE IC: 12190A-VERTEXEDGE Page 2 of 23 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. Revision History Rev. Issue Date Revisions Revised By V1 07/16/20 Initial issue Robby Lee V2 08/06/20 Updated for the additional test Robby Lee V3 08/07/20 Updated the description to TCB’s question Robby Lee REPORT NO: 4789458470-FR1V3 DATE: AUG 07, 2020 FCC ID: 2ACSZVERTEXEDGE IC: 12190A-VERTEXEDGE Page 3 of 23 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 6 4.1. MEASURING INSTRUMENT CALIBRATION ................................................................ 6 4.2. SAMPLE CALCULATION .............................................................................................. 6 4.3. MEASUREMENT UNCERTAINTY ................................................................................ 6 4.4. DECISION RULE .......................................................................................................... 6 5. EQUIPMENT UNDER TEST ............................................................................................... 7 5.1. DESCRIPTION OF EUT ................................................................................................ 7 5.2. MAXIMUM E-FIELD STRENGTH .................................................................................. 7 5.3. WORST-CASE CONFIGURATION AND MODE ........................................................... 7 5.4. DESCRIPTION OF TEST SETUP ................................................................................. 8 6. TEST AND MEASUREMENT EQUIPMENT ......................................................................10 7. OCCUPIED BANDWIDTH .................................................................................................11 8. 20dB BANDWIDTH ...........................................................................................................12 9. RADIATED EMISSION TEST RESULTS...........................................................................13 9.1. LIMITS AND PROCEDURE .........................................................................................13 9.1.1. FUNDAMENTAL AND SPURIOUS EMISSIONS (0.15 – 30 MHz) .........................16 9.1.2. SPURIOUS EMISSION 0.009 TO 30 MHz .............................................................18 9.1.3. TX SPURIOUS EMISSION 30 TO 1000 MHz ........................................................20 10. AC MAINS LINE CONDUCTED EMISSIONS .................................................................22 11. FREQUENCY STABILITY ..............................................................................................23 REPORT NO: 4789458470-FR1V3 DATE: AUG 07, 2020 FCC ID: 2ACSZVERTEXEDGE IC: 12190A-VERTEXEDGE Page 4 of 23 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: Honeywell Analytics Inc. EUT DESCRIPTION: NFC MODEL NUMBER: Vertex Edge Analyzer SERIAL NUMBER: Identical prototype; DATE TESTED: May 20, 2020 – Aug 06, 2020; APPLICABLE STANDARDS STANDARD TEST RESULTS CFR 47 Part 15 Subpart C Complies ISED RSS-210 Issue 10 Complies ISED RSS-GEN Issue 5 Complies UL Korea, Ltd. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Korea, Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL Korea, Ltd. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL Korea, Ltd. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification,…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2ACSZVERTEXEDGE IC: 12190A-VERTEXEDGE Page 1 of 3 1. Appendix: TEST SETUP PHOTOS(Conducted Test) 1) CONDUCTED RF MEASUREMENT SETUP CONDUCTED TEST PHOTO FCC ID: 2ACSZVERTEXEDGE IC: 12190A-VERTEXEDGE Page 2 of 3 2. Appendix: TEST SETUP PHOTOS(Radiated Test) 1) RADIATED RF MEASUREMENT SETUP (BELOW 30 MHz) BELOW 30 MHz TEST PHOTO FCC ID: 2ACSZVERTEXEDGE IC: 12190A-VERTEXEDGE Page 3 of 3 2) RADIATED RF MEASUREMENT SETUP (BELOW 1 GHz) END OF REPORT BELOW 1 GHz FRONT TEST PHOTO BELOW 1 GHz REAR TEST PHOTO

Contact Information

Applicant

Charlene Numrych(Regulatory Engineer)
[email protected]847-955-8237Fax: 847-634-1388

Test Firm

UL Korea, Ltd.Junwhan Lee
[email protected]82313379902Fax: +82-31-213-5433

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from Honeywell Analytics Inc

RFID Chemcassette Recognition - FCC ID 2ACSZSPMFLEX - Honeywell Analytics Inc
2ACSZSPMFLEX

RFID Chemcassette Recognition

Sep 01, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter