FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dyzle Services B.V./
  3. 2ADBY0401003

2ADBY0401003Battery operated wireless humidity unit

Dyzle Services B.V.
Battery operated wireless humidity unit - FCC ID 2ADBY0401003 - Dyzle Services B.V.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Aug 23, 2015
Application Purpose
Original Equipment
Date of Application
Aug 17, 2015
Equipment Note
Battery operated wireless humidity unit
Frequency Range
2404.00000000 - 2480.00000000
Company
Dyzle Services B.V.
Country
Netherlands

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Dyzle BV, 2d Transistorstraat, 1322 CE Almere (NL), Tel.: +31(0)36-5233900, Fax: +31(0)36-5233999 © 2015 Dyzle User Manual for RH-Tag (humidity) 2.0, version 1.4, July 2015 1 User Manual for: RH-TAG 2.0 (humidity) Product code 040 1003 001 Version 1.4, July 2015 © 2015 Dyzle Dyzle BV, 2d Transistorstraat, 1322 CE Almere (NL), Tel.: +31(0)36-5233900, Fax: +31(0)36-5233999 © 2015 Dyzle User Manual for RH-Tag (humidity) 2.0, version 1.4, July 2015 2 Foreword This User Manual is intended for users and installers of the Y-Tag RH (humidity) 2.0. Read the User Manual thoroughly before proceeding to install or use the Y-Tag RH 2.0. This product is delivered exclusively to businesses and may only be installed and operated by installers who have been trained by Dyzle. This User Manual makes reference to the Dyzle Hardware Installation Manual. This document provides information on installation and maintenance of the Y-Tag. The Dyzle Portal 2 User Manual describes how to use the online Portal. You can manage your settings and view the data that is submitted by the sensors and Y-Gates in the Portal. Contact your supplier's support department to obtain a copy of the latest version of the Manuals. Table of Contents Foreword .............................................................................................................................. 2 General description of the Dyzle solution ............................................................................. 2 General description of the Y-Tag RH 2.0 ............................................................................. 3 Product specifications .......................................................................................................... 3 Safety ................................................................................................................................... 3 Placement and installation ................................................................................................... 3 Making the device operational and resetting it ..................................................................... 3 Maintenance and battery replacement ................................................................................. 3 Warranty ............................................................................................................................... 4 Declaration of conformity ...................................................................................................... 4 Disposal ................................................................................................................................ 4 General description of the Dyzle solution The Y-Tag RH 2.0 is part of the Dyzle solution. The solution consists of a personal dashboard (online Portal) and the necessary hardware. The hardware will take and send measurements to Dyzle in the form of data packages, which can contain information such as: • temperature measurements; • door monitoring (door open / closed); • humidity (% RH); • electricity consumption; • location (GPS; only for a mobile location); • CO 2 . The hardware consists of sensors (Y-Tags) and a base station (Y-Gate) that communicate wirelessly with one another. The components contain electronics that are powered by an adapter, the vehicle's battery, or a battery-pack. The components are NOT waterproof, unless specified otherwise, and must therefore be protected from water and other liquids. Other than the wiring and sensors, which are designed for high-temperature applications and are explicitly specified as such, the hardware itself should NOT be exposed to temperatures above 50°C. Dyzle sensors can be used for measuring temperatures in cold rooms, freezers, refrigerators, refrigerated displays, and promotional displays. Both air- and product-temperature are measurable and are therefore distinguished from one another. Outfitting a delivery truck or van, which contain food or pharmaceutical products, with the hardware allows for continuous recording of position and / or temperature of the conditioned space. The Dyzle solution is designed to address the needs of customers in the food, pharmaceutical / care and transport industries in terms of: • Automated temperature registration (24/7); • Notification service in the event of a temperature exceedance by email, premium SMS or IVR*; • Automated HACCP / QA reports. * For Interactive Voice Response (IVR): ask the support department about the possibilities. Dyzle BV, 2d Transistorstraat, 1322 CE Almere (NL), Tel.: +31(0)36-5233900, Fax: +31(0)36-5233999 © 2015 Dyzle User Manual for RH-Tag (humidity) 2.0, version 1.4, July 2015 3 General description of the Y-Tag RH 2.0 The Dyzle Y-Tag RH 2.0 is a wireless sensor with which the relative humidity can be measured. The Y-Tag RH 2.0 can be used to record relative humidity in cold stores, freezers, cold storage trucks, etc. The Y-Tag RH 2.0 takes a measurement every five minutes and sends the measurement data to the Y-Gate. The Y-Gate - the base station – collects the measurement data from the RH-Tag(s) and sends the data to the server. Product specifications* Product code 040 1003 001 Measuring range 10% to 90% relative humidity (non-condensing) Accuracy ± 4 % Resolution 0.04 Measurement interval 5 minutes Memory ± 25 days (data backup when the connection to the Y-Gate is lost) Connectivity to Y-Gate WIFID, 2.4 GHz (coded) Connectivity range 100 m (unobstructed) Power supply 3.6 V DC (lithium battery) Battery life (guaranteed) 1 year (room temperature) Operating temperature 0 °C to +50 °C Operating humidity 10% to 90% relative humidity (non-condensing) Water resistance IP30 * Refer to the separate product specifications overview for the comprehensive product features. Safety Installation of the Y-Tag RH 2.0 requires general knowledge of safe work practices, therefore may only be carried out by personnel holding the required operational Safety Certificate, and should also have the …

Text truncated - open the document above for the full version.

External Photos

Photographs module 20114119301 External PHOTOGRAPH 1: - OVERVIEW OF RH-TAG 2.0 / 040 1003 001 ......................................................................... 2 PHOTOGRAPH 2: - BOTTOM VIEW OF RH-TAG 2.0 / 040 1003 001 .................................................................... 3 Page: 2 of 3 Photograph module 20114119301 external Photograph 1: - Top view of RH-TAG 2.0 / 040 1003 001 Page: 3 of 3 Photograph module 20114119301 external Photograph 2: - Bottom view of RH-TAG 2.0 / 040 1003 001

ID Label/Location Info

0560 Model 040 1003 001 Designed by Dyzle FCC ID:2ADBY0401003

Internal Photos

Photographs module 20114119301 Internal PHOTOGRAPH 1: - INTERNAL VIEW OF RH-TAG 2.0 / 040 1003 001 .................................................................. 2 PHOTOGRAPH 2: - MAIN PCB OF RH-TAG 2.0 / 040 1003 001 TOP VIEW.......................................................... 3 PHOTOGRAPH 3: - MAIN PCB OF RH-TAG 2.0 / 040 1003 001 BOTTOM VIEW ................................................... 4 Page: 2 of 4 Photograph module 20114119301 internal Photograph 1: - Internal view of RH-TAG 2.0 / 040 1003 001 Page: 3 of 4 Photograph module 20114119301 internal Photograph 2: - Main PCB of RH-TAG 2.0 / 040 1003 001 top view Page: 4 of 4 Photograph module 20114119301 internal Photograph 3: - Main PCB of RH-TAG 2.0 / 040 1003 001 bottom view

Test Report

Radio test report 20114119301-Ver 2.00 based on: - FCC part 15; subpart C; section 15.249 & 15.209 (10-1-13 edition) - FCC part 15, subpart B: section 15.109 (10-1-13 edition) Battery operated wireless humidity unit Dyzle RH-TAG 2.0 / 040 1003 001 Revision history Report number: 20114119301-Ver 2.00 Revision history REVISION DATE REMARKS REVISED BY Ver 2.00 2015 07 07 Correction of release dates ing. J.C. le Clercq Ver 1.00 2015 02 12 Initial release ing. J.C. le Clercq Ver 0.50 2014 11 26 Version for peer review ing. J.C. le Clercq Main module Report number: 20114119301-Ver 2.00 Contents REVISION HISTORY .................................................................................................................................... 2 MAIN MODULE ............................................................................................................................................. 4 1 ..... INTRODUCTION...................................................................................................................................... 4 2 ..... PRODUCT .............................................................................................................................................. 5 3 ..... TEST SCHEDULE .................................................................................................................................... 5 4 ..... PRODUCT DOCUMENTATION .................................................................................................................. 5 5 ..... OBSERVATIONS AND COMMENTS ........................................................................................................... 6 6 ..... MODIFICATIONS TO THE SAMPLE ........................................................................................................... 6 7 ..... SUMMARY ............................................................................................................................................. 6 8 ..... CONCLUSIONS ....................................................................................................................................... 7 TEST RESULTS MODULE ........................................................................................................................... 8 1 ..... GENERAL INFORMATION ........................................................................................................................ 8 1.1 Equipment information .................................................................................................................... 8 2 ..... EMISSION TESTS .................................................................................................................................... 9 2.1 Field strength of intentional signal ................................................................................................... 9 2.2 Field strength of unwanted emissions 30 - 1000 MHz in transmit mode ....................................... 10 2.3 Field strength of unwanted emissions 30 - 1000 MHz in receive mode ......................................... 13 2.4 Average factor ................................................................................................................................ 16 2.5 Field strength of unwanted emissions > 1000 MHz in transmit mode ........................................... 17 2.6 TX unwanted emission of harmonics, horizontal polarization ....................................................... 20 2.7 TX unwanted emission of harmonics, vertical polarization ........................................................... 21 2.8 Field strength of unwanted emissions > 1000 MHz in receive mode ............................................. 22 USED TEST EQUIPMENT MODULE ....................................................................................................... 24 This report comprises of three modules. The total number of pages is: 25 Page: 4 of 25 Main module Report number: 20114119301-Ver 2.00 Main module 1 Introduction This report contains the result of tests performed by: Telefication B.V. Edisonstraat 12a 6902 PK Zevenaar The Netherlands Telefication complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 17025:2005. The accreditation covers the quality system of the laboratory as well as the specific activities as described in the authorized annex bearing the accreditation number L021 and is granted on 30 November 1990 by the Dutch Council For Accreditation (RvA: Raad voor Accreditatie). Telefication is designated by the FCC as an Accredited Test Firm for compliance testing of equipment subject to Certification under Parts 15 & 18. The Registration Number is: 282250. The Industry Canada number for the Open Area Test Site of Telefication is: 4173A-1. The contents of this test report, if reproduced, shall be copied in full, unless special consent in writing for reproduction in part is granted by Telefication. Copyright of this test report is reserved to Telefication. Ordering party: Company name : Dyzle Services B.V. Address : Transistorstraat 2D Zipcode : 1322 CE City/town : Almere Country : The Netherlands Date of order : 22 August 2014 Page: 5 of 25 Main module Report number: 20114119301-Ver 2.00 2 Product A sample of the following product was submitted for testing: Product description : Battery operated wireless humidity unit Manufacturer : Dyzle Services B.V. Trade mark : Dyzle Type designation : RH-TAG 2.0 / 040 1003 001 FCC ID : 2ADBY040103 Hardware version : 2.0 Software release : 0.28 Serial number : -- 3 Test schedule Tests are carried out in accordance with the specification detailed in chapter 7 “Summary” of this report. Tests are carried out at the following location: Telefication, Zevenaar The samples of the product were received on: 22 September 2014 Tests are carried out between: 2 October and 30 October 2014 4 Product documentation For production of this report the following product documentation wa…

Text truncated - open the document above for the full version.

Test Setup Photos

Photographs module 20114119301 Y-TAG 2.0 / 040 1003 001 Test set up PHOTOGRAPH 1: TEST SETUP RADIATED EMISSIONS 30-1000 MHZ) ................................................................... 2 PHOTOGRAPH 2: TEST SETUP RADIATED EMISSIONS 1-18 GHZ) ......................................................................... 3 PHOTOGRAPH 3: TEST SETUP RADIATED EMISSIONS 18 - 26 GHZ ....................................................................... 4 Page: 2 of 4 Photograph module 20114119301 test setup Photograph 1: Test setup radiated emissions 30-1000 MHz) Page: 3 of 4 Photograph module 20114119301 test setup Photograph 2: Test setup radiated emissions 1-18 GHz) Page: 4 of 4 Photograph module 20114119301 test setup Photograph 3: Test setup radiated emissions 18 - 26 GHz

Contact Information

Applicant

Rene Tjong Tjin Tai(CTO)
[email protected]+31 365233900Fax: +31 365233999

Technical Contact

Dyzle Services B.V.Rene Tjong Tjin Tai
[email protected]31362533900

Transistorstraat 2d Almere · Netherlands

Non-Technical Contact

Dyzle Services B.V.Rene Tjong Tjin Tai
[email protected]31362533900

Test Firm

Kiwa Nederland B.V.Willem Jong
[email protected]+31 889983621

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from Dyzle Services B.V.

Battery operated wireless pulse counter unit - FCC ID 2ADBY0501007 - Dyzle Services B.V.
2ADBY0501007

Battery operated wireless pulse counter unit

Aug 23, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Battery operated wireless PT100 temperature unit - FCC ID 2ADBY0201501 - Dyzle Services B.V.
2ADBY0201501

Battery operated wireless PT100 temperature unit

Aug 23, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Y-Gate 3.0 Base Station - FCC ID 2ADBY0101701 - Dyzle Services B.V.
2ADBY0101701

Y-Gate 3.0 Base Station

Jul 16, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter