Quick Setup 1. Insert 3 AA batteries into Alarm Monitor (WAM-1) & 2 AAA batteries into Transmitter (WAT-1). 2. Press & hold Alarm Monitor SYNC button. Red light turns on. Sync mode will remain active for 10 seconds. 3. Press Transmitter SYNC button. Red light turns on and Alarm Monitor beeps once. 4. Both red lights will turn off. Monitor & Transmitter are now synced. Test before each use. 5. Sync up to three Transmitters (WAT-1) with Alarm Monitor (WAM-1) when multiple bed, chair, or floor mat sensors are needed. All Transmitters must be synced within 10 seconds of sync mode activation. 6. Please check the position of the Mute switch on the base of the monitor next to the Nurse Call receptacle. If you want the Monitor to sound in the room please set the Mute switch to the “Off” position. If you DO NOT want the monitor to sound in the room please set the Mute switch to the “On” position. Important: WAM-1 patient monitor Mute switch should only be set to “On” position when patient monitor is connected to nurse call interface using the optional nurse call cable adapter (Model No. NCI-1). Set Mute switch to “Off” position to enable alarm sound. WARNING: Changes or modifications to this product that are not authorized by the manufacturer may void FCC compliance and negate the user’s authority to operate this product. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by: 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help. System Overview The Secure ® Wire•Less ® Patient Monitoring System takes fall management patient alarms to the next level by eliminating tripping hazards, taking the alarm sound out of the patient room, and employing the most advanced, continuous 2.4G bi-directional wireless communication that ensures secure communication between the Wire•Less ® Alarm Monitor (WAM-1) and Wire•Less ® Alarm Transmitter (WAT-1) housed in the pocket of a Secure ® bed or chair sensor pad or floor mat sensor. When a patient gets off the monitoring pad housing the transmitter, the transmitter will instantly send a wireless signal to the monitor without a dangerous delay that is found in other patient monitors. The monitor will then send a confirmation signal to the transmitter to stop the transmitter signal conserving battery life. The monitor will automatically reset once the patient gets back on the bed/chair sensor pad. Alternatively, the monitor can be reset by pressing the reset button located on the front of the monitor. When using a floor mat sensor, the monitor will continue to alarm until the reset button is pressed. Monitor can be synced with up to three transmitters, allowing a single alarm monitor to wirelessly connect with and monitor up to three Secure® bed/chair sensor pads, floor mat sensors, and wheelchair seat belt sensor. The monitor may be connected to a standard nurse call system using the optional Nurse Call Cable accessory (NCI- 1). When connected to a nurse call system, the monitor alarm sound may be left on or muted to eliminate in-room alarm noise. The Monitor will activate the nurse call system to alert the nurses’ station of unsafe patient egress. When in standby, the monitor and transmitter communicate every 5 minutes to confirm both remain synced. If the monitor and transmitter become unpaired the 3rd LED light on the front of monitor will flash continuously and the alarm will sound continuously indicating the system is not functioning properly. Note: Always keep the WAT-1 Alarm Transmitter on/off switch in the “on” position whenever batteries are installed in the WAM-1 Alarm Monitor. This will maintain the unique bi-directional connectivity of the WAM-1 and WAT-1 and prevent unwanted alarm sound due to a lost connection. Personal Safety Corporation • Hiawatha, Iowa 52233 • 800.373.2873 U.S. Patent No. 9,466,204 PATIENT MONITORING SYSTEM • Wire•Less ® Alarm Monitor – Model No. WAM-1 • Wire•Less ® Alarm Transmitter – Model No. WAT-1 • Wire•Less ® Bed Sensor Pad (One Year) – Model No. BEDPAD-1W • Wire•Less ® Chair Sensor Pad (One Year) – CHAIRPAD-1W • Wire•Less ® Floor Mat Sensor (One Year) – MAT-1W Made in PRC • One Year Warranty Revised: 07/20/18 For safety reasons, the WAM-1 has been designed to wirelessly communicate with the WAT-1 every 2.5 minutes to ensure that the system is synced. If the WAM-1 and WAT-1 become un-synced for whatever reason, the WAM-1 will alarm and flash. If the WAT-1 is turned off or its batteries removed, the WAM-1 will alarm and flash. Therefore, it is necessary to remove the batteries from the WAM-1 when the WAT-1 is turned off or batteries removed. If batteries are left installed in the WAM-1 while the WAT-1 is turned off or batteries removed, the lost connection alarm will continue to sound indicating that the WAM-1 is unable to sync with the WAT-1. Removing all batteries will conserve battery life when the system is not in use. Setup Instructions (Call 800-3-Secure for Setup Help) 1. Wire•Less ® Alarm Monitor (WAM-1) – Install Batteries& Set Volume/Tone • Remove WAM-1 from protective holder • Fully loosen battery cover s…
Text truncated - open the document above for the full version.
FCCID:2ADJMWAT-1R FCCID:2ADJMWAT-1R
WAM01 silkscreen SENSOR PAD 紅燈 黃燈 SY NC 0 2 4 Delay FL OOR MAT BED/CHAIR P AD ONOFF 丝印颜色:PANTONE:281C 外壳颜色:PANTONE:422C
FCCID:2ADJMWAT-1R FCCID:2ADJMWAT-1R FCCID:2ADJMWAT-1R
ShenzhenHuaxiaTestingTechnologyCo.,Ltd 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V04 ReportTemplateRevisionDate:2018-07-06 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlytothesample(s) tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.: CQASZ202100500723E-02 Applicant: ProfessionalSecurityCorporationDBAPersonalSafetyCorporation AddressofApplicant: 1655ProgressDrive,Hiawatha,Iowa52233,USA EquipmentUnderTest(EUT): EUTName: WirelessAlarmTransmitter ModelNo.: WAT-1R BrandName: Secure® FCCID: 2ADJMWAT-1R Standards: 47CFRPart1.1307 47CFRPart1.1310 KDB447498D01GeneralRFExposureGuidancev06 DateofReceipt: 2021-05-28 DateofTest: 2021-05-28to2021-06-24 DateofIssue: 2021-06-24 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove TestedBy: (LewisZhou) ReviewedBy: (JunLi) ApprovedBy: (SheekLuo) ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ202100500723E-02 Page:2of6 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ202100500723E-02Rev.01 Initialreport 2021-06-24 ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ202100500723E-02 Page:3of6 2Contents Page 1VERSION.............................................................................................................................................................................2 2CONTENTS.........................................................................................................................................................................3 ..................................................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1CLIENTINFORMATION....................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT....................................................................................................................................4 4RFEXPOSUREEVALUATION.......................................................................................................................................5 4.1RFEXPOSURECOMPLIANCEREQUIREMENT..................................................................................................................5 4.1.1StandardRequirement......................................................................................................................................5 4.1.2Limits....................................................................................................................................................................5 4.2EUTRFEXPOSUREEVALUATION..................................................................................................................................6 ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ202100500723E-02 Page:4of6 3GeneralInformation 3.1ClientInformation Applicant: ProfessionalSecurityCorporationDBAPersonalSafetyCorporation AddressofApplicant: 1655ProgressDrive,Hiawatha,Iowa52233,USA Manufacturer: ProfessionalSecurityCorporationDBAPersonalSafetyCorporation AddressofManufacturer: 1655ProgressDrive,Hiawatha,Iowa52233,USA 3.2GeneralDescriptionofEUT ProductName: WirelessAlarmTransmitter ModelNo.: WAT-1R TradeMark: Secure® HardwareVersion: V1.0 SoftwareVersion: V1.0 FrequencyRange:2432MHz~2454MHz ModulationType:GFSK NumberofChannels:3 SampleType: MobilePortableFixLocation TestSoftwareofEUT:RFtest AntennaType:PCBantenna AntennaGain:1.6dBi PowerSupply:BecausethistestEUTispoweredby2*AAAsizebatteries ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ202100500723E-02 Page:5of6 4RFExposureEvaluation 4.1RFExposureComplianceRequirement 4.1.1StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 4.3.1.StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-g headorbodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions,by measurementornumericalsimulation,isnotrequiredwhenthecorrespondingSARExclusion Thresholdcondition,listedbelow,issatisfied. 4.1.2Limits The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparationdistances ≤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance,mm)]· [√f(GHz)]≤3.0for1-gSARand≤7.5for10-gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation 17 Theresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤50mmand fortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtestseparation distanceis<5mm,adistanceof5mmisappliedtodetermineSARtestexclusion ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ202100500723E-02 Page:6of6 4.2EUTRFExposureEvaluation 1)For2.4G eirp=ptxgt=(Exd) 2 /30 where: pt=transmitteroutputpowerinwatts, gt=numericgainofthetransmittingantenna(unitless), E=electricfieldstrengthinV/m,---10 ((dBμV/m)/20) /10 6 , d=measurementdistanceinmeters(m)---3m, Sopt=(Exd) 2 /30/gt Theworstcase(refertoreportCQASZ202100500723E-01)isbelow: Antennapolarization:Horizontal Frequency(MHz)Level(dBuV/m) Polarization 245489.61Peak 245486.86Average For2460MHzwireless: Fieldstrength=89.61dBμV/m@3m Ant.gain0dBi;soAntnumericgain=1.0 Sopt={[10 (89.61/20) /10 6 x3] 2 /30/1.0}x1000mW=0.274mW So(0.274mW/5mm)x√2.460GHz=0.086, 0.086<3.0for1-gSAR SotheSARreportisnotrequired.
ShenzhenHuaxiaTestingTechnologyCo.,Ltd 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V04 ReportTemplateRevisionDate:2018-07-06 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonly tothesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.: CQASZ202100500723E-01 Applicant: ProfessionalSecurityCorporationDBAPersonalSafetyCorporation AddressofApplicant: 1655ProgressDrive,Hiawatha,Iowa52233,USA EquipmentUnderTest(EUT): EUTName: WirelessAlarmTransmitter ModelNo.: WAT-1R BrandName: Secure® FCCID: 2ADJMWAT-1R Standards: 47CFRPart15,SubpartC DateofReceipt: 2021-05-28 DateofTest: 2021-05-28to2021-06-24 DateofIssue: 2021-06-24 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove TestedBy: (LewisZhou) ReviewedBy: (JunLi) ApprovedBy: (SheekLuo) ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ202100500723E-01 Page:2of29 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ202100500723E-01Rev.01 Initialreport 2021-06-24 ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ202100500723E-01 Page:3of29 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15,SubpartCSection 15.203 ANSIC63.10(2013)PASS ACPowerLine ConductedEmission 47CFRPart15,SubpartCSection 15.207 ANSIC63.10(2013)N/A FieldStrengthofthe FundamentalSignal 47CFRPart15,SubpartCSection 15.249(a) ANSIC63.10(2013)PASS SpuriousEmissions 47CFRPart15,SubpartCSection 15.249(a)/15.209 ANSIC63.10(2013)PASS Restrictedbands aroundfundamental frequency(Radiated Emission) 47CFRPart15,SubpartCSection 15.249(a)/15.205 ANSIC63.10(2013)PASS 20dBOccupied Bandwidth 47CFRPart15,SubpartCSection 15.215(c) ANSIC63.10(2013)PASS N/A:BecausethistestEUTispoweredby2*AAAsizebatteries. ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ202100500723E-01 Page:4of29 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION.................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................5 4.3TESTENVIRONMENTANDMODE................................................................................................................................7 4.4DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................7 4.5STATEMENTOFTHEMEASUREMENTUNCERTAINTY...................................................................................................8 4.6TESTLOCATION..........................................................................................................................................................9 4.7TESTFACILITY............................................................................................................................................................9 4.8DEVIATIONFROMSTANDARDS...................................................................................................................................9 4.9ABNORMALITIESFROMSTANDARDCONDITIONS........................................................................................................9 4.10OTHERINFORMATIONREQUESTEDBYTHECUSTOMER...........................................................................................9 4.11EQUIPMENTLIST.....................................................................................................................................................10 5TESTRESULTSANDMEASUREMENTDATA......................................................................................................11 5.1ANTENNAREQUIREMENT..........................................................................................................................................11 5.2RADIATEDEMISSION.................................................................................................................................................12 5.320DBBANDWIDTH....................................................................................................................................................20 6PHOTOGRAPHS...........................................................................................................................................................23 6.1RADIATEDEMISSIONTESTSETUP............................................................................................................................23 6.2EUTCONSTRUCTIONALDETAILS.............................................................................................................................25 ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ202100500723E-01 Page:5of29 4GeneralInformation 4.1ClientInformation Applicant: ProfessionalSecurityCorporationDBAPersonalSafetyCorporation AddressofApplicant: 1655ProgressDrive,Hiawatha,Iowa52233,USA Manufacturer: ProfessionalSecurityCorporationDBAPersonalSafetyCorporation AddressofManufacturer: 1655ProgressDrive,Hiawatha,Iowa52233,USA 4.2GeneralDesc…
Text truncated - open the document above for the full version.
FCCID:2ADJMWAT-1R 30MHz~1GHz: FCCID:2ADJMWAT-1R Above1GHz:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.43 GHz - 2.45 GHz | - |

Secure Wireless Alarm Transmitter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Secure Wireless Call Button Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter