FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hangzhou Hikvision Digital Technology Co., Ltd./
  3. 2ADTD-D0710030

2ADTD-D0710030Wired Dual-Tech AM Curtain Detector

Hangzhou Hikvision Digital Technology Co., Ltd.
Wired Dual-Tech AM Curtain Detector - FCC ID 2ADTD-D0710030 - Hangzhou Hikvision Digital Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
May 18, 2021
Application Purpose
Original Equipment
Date of Application
May 17, 2021
Equipment Note
Wired Dual-Tech AM Curtain Detector
Frequency Range
24187.00000000 - 24187.00000000
Company
Hangzhou Hikvision Digital Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wired Dual-Tech AM Curtain Detector DS-PDC10DM-VG3 User Manual Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Alarm: Microwave Triggered: Anti-Masking: Fault: PIR Triggered: 5.LED Jumper 6. Anti-masking Jumper 7.Direction Jumper L→R: direction from left to right only R→L: direction from right to left only OFF: Turns off the direction selection Appearance 2.LED Indicator3.Tamper Switch 1.Terminal 4.Mode Switch Installation Anti-Masking Resistor Wiring Connection Type Method 1: Use the jumper to select EOL (End of Line) resistance on FAULT/TAMPER/ALARM pins. Method 2: Add the resistor to FAULT/TAMPER/ALARM wiring ports. Note: If EOL wiring is not used, leave the jumpers OFF. Do not force the jumper if it is not matched the pin. Method 1 & 2 should not be used on the ALARM/TAMPER at the same time. a. Fault Resistance: 1K, 2K2, 6K8 b. Tamper Resistance: 1K, 2K2, 4K7, 5K6 c.Alarm Resistance: 1K, 2K2, 4K7, 5K6, 6K8 Note: The resistor must be connected in series with one end of the detector. a. Normally Closed b. Single End of Line Wiring c.Double End of Line Wiring: d. Triple End of Line Wiring: NormalIntrusionAlarmFaultMask Alarm RelayCloseOpenCloseOpen Fault RelayCloseCloseOpenOpen Relay Status Ceiling mounting Wall mounting Mounting with the general mounting plate. Mounting with L-mounting plate. 4m 0m 1m 1m 0m 6m 6m Side View 0.6m 0m 0m 10m 1m 10m + + WEAK INVERSE STRONG INVERSE <1 min <30 s = ALARMTAMPER +- EOLEOL FAULT 5K6 4K7 2K2 1K LED 6K8 2K2 1K6K8 5K6 4K7 2K2 1K MASKRTRA 2.2K ALARMTAMPER +- EOLEOL FAULTLED = ALARMTAMPER +- EOLEOL FAULT 5K6 4K72K2 1K LED 6K82K2 1K 6K8 5K6 4K72K2 1K MASKRTRA 2.2K ALARMTAMPER +- EOLEOL FAULTLED = ALARMTAMPER +- EOLEOL FAULT 5K6 4K72K2 1K LED 6K82K2 1K 6K8 5K6 4K72K2 1K MASKRTRA 2.2K ALARMTAMPER +- EOLEOL FAULTLED ALARMTAMPER +- EOLEOL FAULTLED MASKRART C W ZONE2COMZONE1COM + - ZONE3COM 2.2k 2.2k ALARMTAMPER +- EOLEOL FAULT 5K6 4K72K2 1K LED 6K82K2 1K6K8 5K64K72K2 1K MASKRTRA 2.2k ZONE2COMZONE1COM + - ZONE3COM ALARMTAMPER+- EOLEOL FAULT 5K6 4K72K2 1K LED 6K82K2 1K6K8 5K64K72K2 1K MASKRTRA a b c d ZONE2 COMCOMZONE1 + - ZONE3COM ALARMTAMPER+- EOLEOL FAULT 5K6 4K72K2 1K LED 6K82K2 1K6K8 5K64K72K2 1K MASKRTRA ZONE2COMZONE1COM + - ZONE3COM ALARMTAMPER+- EOLEOL FAULT 5K6 4K72K2 1K LED 6K82K2 1K6K8 5K64K72K2 1K MASKRTRA G L 4m EN 50131-2-4:2020 Security Grade3 Environment Class IV Certified by KIWA 2.2K 2.2K Detection MethodPassive Infrared,Microwave Wall Mount10m Ceiling Mount6m DetectionAngle5° DetectableSpeed 0.23m/s SensitivityAuto WhiteLightFilter6500lux MicrowaveFrequency 24GHz(24.15 24.25GHz) DigitalTemperatureCompensationSupport Creep ZoneProtectionSupport Anti-maskingSupport DigitalProcessingSupport SealedOpticsSupport TamperProtectionFront,Rear AlarmOutputNormallyClosed LED IndicatorGreen(PIR),Red(Microwave),Green+Orange(Mask),Blue(Alarm) PowerConsumption22mA Max PowerSupply9to16VDC TypicalVoltage12VDC OperationTemperature-10°Cto55°C(14°Fto131°F) StorageTemperature-20°Cto60°C(-4°Fto140°F) OperationHumidity10%to90% IPRateIP65 Dimension(WxHxD)29.2mm × 134.4mm × 39.5mm Weight79g MountingHeight2to4m Mounting MethodWall,Ceiling ApplicationScenarioIndoor,Outdoor BracketL-shapedadapterincluded DetectionRange Please use the power adapter complianting with LPS. The recommended power adapter is made by Shenzhen Honor Electronic Co., Ltd. Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Alarm: Mikrowellen-Auslösung: Anti-Maskierung: Fehler: PIR-Auslösung: 3.Sabotageschalter 5.LED-Steckbrücke 6.Anti-Maskierung-Steckbrücke 7.Richtungs-Steckbrücke L→R: Richtung nur von links nach rechts R→L: Richtung nur von rechts nach links AUS: Schaltet die Richtungsauswahl aus Aufbau 2.LED-Anzeige1.Anschlussklemmen 4.Modusschalter Installation Anti-Maskierung Widerstandsverdrahtung Anschlussart Methode 1: Verwenden Sie die Steckbrücke, um Leitungsabschluss-Widerstand (EOL) an FEHLER/SABOTAGE/ALARM-Kontaktstiften zu wählen. Methode 2: Schließen Sie den Widerstand an den FEHLER/SABOTAGE/ALARM-Verdrahtungsanschlüssen an. Hinweis: Verwenden Sie KEINE Steckbrücken, wenn EOL-Verdrahtung nicht genutzt wird. Die Steckbrücke darf nicht gewaltsam aufgesteckt werden, wenn sie nicht auf den Kontaktstift passt. Methode 1 und 2 dürfen nicht gleichzeitig auf den ALARM/SABOTAGE-Stiftleisten verwendet werden. a. Fehlerwiderstand: 1K, 2K2, 6K8 b. Sabotage-Widerstand: 1K, 2K2, 4K7, 5K6 c.Alarmwiderstand: 1K, 2K2, 4K7, 5K6, 6K8 Hinweis: Der Widerstand muss mit einem Kontakt des Melders in Reihe geschaltet werden. a. Normal geschlossen b. Einzel-Leitungsabschlussverdrahtung c.Doppel-Leitungsabschlussverdrahtung: d. Dreifach-Leitungsabschlussverdrahtung: NormalEinbruchalarmFehlerMaske AlarmrelaisSchließen OpenSchließen Open FehlerrelaisSchließen SchließenOpenOpen Relaisstatus Deckenmontage Wandmontage Montage mit allgemeiner Montageplatte. Montage mit L-Montageplatte. ErkennungsmethodePassives Infrarot, Mikrowelle Wandmontage: 10 m Deckenmontage: 6 m Erkennungswinkel5° Erfassungsgeschwindigkeit0,2-3 m/s EmpfindlichkeitAutomatisch Weißlichtfilter6500Lux Mikrowellenfrequenz24GHz (24,15-24,25GHz) DigitaleTemperaturkompensationUnterstützt KriechzonenschutzUnterstützt AntimaskierungUnterstützt DigitaleVerarbeitungUnterstützt VersiegelteOptikUnterstützt SabotageschutzVorderseite, Rückseite AlarmausgangNormalgeschlossen LED-Anzeige Grün (PIR),Rot (Mikrowelle),Grün+Orange (Maske),Blau (Alarm) Stromverbrauchmax. 22 mA Spannungsversorgung9bis16 VGleichspannung TypischeSpannung12 VDC Betriebstemperatur-10°Cbis +55°C Lagertemperatur-20°Cbis +60°C Betriebsfeuchtigkeit10 %bis90 % IP-SchutzartIP65 Abmessungen (B x H xT)29,2 mmx 134,4 mmx 39,5mm Gewicht79 g Montagehöhe2bis 4 m MontageortWand,Decke AnwendungsszenarioInnen-,Außenbereich HalterungL-förmigerAdapterimLieferumfangenthalten Erkennungsbereich Allarme: Microonde attivato: Anti-mascheramento: Guasto: PIR attivato: 3.Interruttore antimanom…

Text truncated - open the document above for the full version.

Cover Letter(s)

Hangzhou Hikvision Digital Technology Co.,Ltd. Date: 8-May-21 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Hangzhou Hikvision Digital Technology Co., Ltd. FCC ID: 2ADTD-D0710030 FCC Part 15C Certification Confidentiality Request Gentlemen: This letter is to comply with 47 CFR 0.457 and 0.459 pertaining to confidentiality material. Hangzhou Hikvision Digital Technology Co., Ltd. requests that the following documents regarding this submission for FCC ID: 2ADTD-D0710030 be kept confidential: Exhibit Type Block Diagram Schematics Operation description Those documents contain detailed system and equipment description and related information about the product which Hangzhou Hikvision Digital Technology Co., Ltd. considers to be confidential proprietary, a custom design and, otherwise, not releasable to the general public. Since this design is a basis form which future technological products will evolve, Hangzhou Hikvision Digital Technology Co., Ltd. considers this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Yours Sincerely, Xiuying zhang/certification Manager Hangzhou Hikvision Digital Technology Co., Ltd TEL: +86-18015557812 E-mail: [email protected]

Cover Letter(s)

Hangzhou Hikvision Digital Technology Co.,Ltd. No. 555, Qianmo Road, Binjiang District, Hangzhou,310052, China Declaration of Authorization We Name: Hangzhou Hikvision Digital Technology Co., Ltd. Address: No. 555, Qianmo Road, Binjiang District, Hangzhou, 310052, China Declare that: Name Representative of agent: Marlin Chen Agent Company name: MRT Technology (Suzhou) Co., Ltd Address: D8 Building, Youxin Industrial Park, No.2 Tian'edang Rd., Wuzhong Economic Development Zone City: Suzhou Country: China is authorized to apply for Certification of the following product(s): Product: Wired Dual-Tech AM Curtain Detector Model: DS-PDC10DM-VG3 FCC ID: 2ADTD-D0710030 Sincerely, ___________________ Xiuying zhang/certification Manager Hangzhou Hikvision Digital Technology Co., Ltd TEL: +86-18015557812 E-mail: [email protected]

Cover Letter(s)

Hangzhou Hikvision Digital Technology Co., Ltd No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Federal Communications Commission Authorization and Evaluation Division Data: May 08, 2021 Confidentiality Request FCC ID: 2ADTD-D0710030 Pursuant to Sections 0.457 and 0.459 of the commission's rules, we request short-term confidential treatment for the following information until 180 days after the Grant Date of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device:  External photos  Test Setup photos  User Manual  Internal Photos Thank you, Sincerely yours, Xiuying zhang/certification Manager Hangzhou Hikvision Digital Technology Co., Ltd TEL: +86-18015557812 E-mail: [email protected]

External Photos

Report No.: 2104RSU049-UE 1 of 3 EUT Photograph (1) EUT Photo (2) EUT Photo Report No.: 2104RSU049-UE 2 of 3 (3) EUT Photo (4) EUT Photo Report No.: 2104RSU049-UE 3 of 3 (5) EUT Photo (6) EUT Photo

Internal Photos

Report No.: 2104RSU049-UE 1 of 2 EUT Photograph (1) EUT Photo (2) EUT Photo 24G RF module Report No.: 2104RSU049-UE 2 of 2 (3) EUT Photo (4) EUT Photo

Test Report

MRT Technology (Suzhou) Co., Ltd Report No.: 2104RSU049-U1 Phone: +86-512-66308358 Report Version: V01 Web: www.mrt-cert.com Issue Date: 05-14-2021 1 of 31 FCC ID: 2ADTD-D0710030 Applicant: Hangzhou Hikvision Digital Technology Co., Ltd Application Type: Certification Product: Wired Dual-Tech AM Curtain Detector Model No.: DS-PDC10DM-VG3 Serial Model No.: DS-PDC10DM-VG3UHK, DS-PDC10DM-VG3CKV, DS-PDC10DM-VG3UVS, DS-PDC10DM-VG3KVO, DS-PDC10DM-VG3HUN Brand Name: HIKVISION FCC Classification: Part 15 Low Power Communication Device Transmitter (DXX) FCC Rule Part(s): Part 15.249 Test Procedure(s): ANSI C63.10 - 2013 Test Date: April 29 ~ May 12, 2021 MEASUREMENT REPORT FCC PART 15.249 Reviewed By: (Oscar Shi) Approved By: (Robin Wu) The test results relate only to the samples tested. This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63.10-2013. Test results reported herein relate only to the item(s) tested. The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou) Co., Ltd. Report No.: 2104RSU049-U1 2 of 31 Revision History Report No. Version Description Issue Date Note 2104RSU049-U1 Rev. 01 Initial Report 05-14-2021 Valid Report No.: 2104RSU049-U1 3 of 31 CONTENTS Description Page 1. General Information ............................................................................................................... 5 1.1. Applicant ....................................................................................................................... 5 1.2. Manufacturer ................................................................................................................ 5 1.3. Testing Facility .............................................................................................................. 5 2. PRODUCT INFORMATION ..................................................................................................... 6 2.1. Equipment Description .................................................................................................. 6 2.2. Test Mode .................................................................................................................... 6 2.3. Test Environment Condition .......................................................................................... 6 2.4. Configuration of Tested System .................................................................................... 7 2.5. Test System Details ...................................................................................................... 7 3. ANTENNA REQUIREMENTS .................................................................................................. 8 4. TEST EQUIPMENT CALIBRATION DATE .............................................................................. 9 5. MEASUREMENT UNCERTAINTY ......................................................................................... 10 6. TEST RESULT ....................................................................................................................... 11 6.1. Summary ..................................................................................................................... 11 6.2. Radiated Emission ...................................................................................................... 12 6.2.1. Test Limit ................................................................................................................ 12 6.2.2. Test Procedure Used .............................................................................................. 13 6.2.3. Test Setting ............................................................................................................. 13 6.2.4. Test Setup ............................................................................................................... 15 6.2.5. Test Result .............................................................................................................. 17 6.3. Radiated Restricted Band Edge Measurement ........................................................... 20 6.3.1. Test Limit ................................................................................................................ 20 6.3.2. Test Procedure Used .............................................................................................. 21 6.3.3. Test Setting ............................................................................................................. 21 6.3.4. Test Setup ............................................................................................................... 22 6.3.5. Test Result .............................................................................................................. 23 6.4. 20dB Spectrum Bandwidth Measurement ................................................................... 27 6.4.1. Test Limit ................................................................................................................ 27 6.4.2. Test Procedure used ............................................................................................... 27 6.4.3. Test Setting ............................................................................................................. 27 6.4.4. Test Setup ............................................................................................................... 27 6.4.5. Test Result .............................................................................................................. 28 Report No.: 2104RSU049-U1 4 of 31 7. CONCLUSION ....................................................................................................................... 29 Appendix A - Test Setup Photograph ......................................................................................... 30 Appendix B - EUT …

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: 2104RSU049-UT 1 of 3 RF Test Setup Photo Description: Radiated Emission Test Setup for 30MHz ~ 1GHz Description: Radiated Emission Test Setup for 1GHz ~ 18GHz Report No.: 2104RSU049-UT 2 of 3 Description: Radiated Emission Test Setup for 18GHz ~ 40GHz Description: Radiated Emission Test Setup for 40GHz ~ 50GHz Report No.: 2104RSU049-UT 3 of 3 Description: Radiated Emission Test Setup for 50GHz ~ 75GHz Description: Radiated Emission Test Setup for 75GHz ~ 100GHz

Contact Information

Applicant

Long Cheng
[email protected]+8618969187825Fax: +86-571-87356146

Technical Contact

MRT Technology (Suzhou) Co., LtdRobin Wu
[email protected]86-512-66308358

D8 Building, Youxin Industrial Park, · Suzhou · China

Non-Technical Contact

MRT Technology (Suzhou) Co., LtdRobin Wu
[email protected]86-512-66308358

Test Firm

MRT Technology (Suzhou) Co., Ltd.Mr. Marlin Chen
[email protected]+86-512-66308358

Technical Specifications

#Rule PartsFrequency RangePower Output
115C24.19 GHz - 24.19 GHz-
Confidentiality
Long Term

Other Applications from Hangzhou Hikvision Digital Technology Co., Ltd.

Ethernet Switch - FCC ID 2ADTD-3WR15X - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-3WR15X

Ethernet Switch

Nov 09, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Face Recognition Terminal - FCC ID 2ADTD-K1T321MFWX - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-K1T321MFWX

Face Recognition Terminal

Nov 09, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Face Recognition Terminal - FCC ID 2ADTD-K1T6QTF43EFW - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-K1T6QTF43EFW

Face Recognition Terminal

Nov 08, 2022

Equipment Class

DTS - Digital Transmission System
Stand Pole - FCC ID 2ADTD-K7CRT01E - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-K7CRT01E

Stand Pole

Nov 08, 2022

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Face Recognition Terminal - FCC ID 2ADTD-K1T321MFX - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-K1T321MFX

Face Recognition Terminal

Nov 08, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter