Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Jan 06, 2021
Application Purpose
Original Equipment
Date of Application
Dec 30, 2020
Equipment Note
Wireless External Magnet Detector
Frequency Range
433.10000000 - 433.70000000
Company
Hangzhou Hikvision Digital Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INSTALACIÓN I. Comprobar la intensidad de la señal. II. Instale el detector. Atornille para un panel real antimanipulación III(Opcional) haga pasar el cable de entrada por el orificio en el caso de que sean necesarias entradas externas. ASPECTO 1. Vara magnética 2. Sensor 3. Batería 4. Interruptor de alimentación 5. Botón antimanipulación 6. Indicador 7. Entrada externa 8. Lámina de manipulación trasera 9. Marca de colocación REGISTRO PRUEBA Compruebe que la posición de instalación sea la adecuada. Tabla de rendimiento de detección de imanes Español 1 4 2 Especificación Manual de usuario 3 Escanee el código QR para obtener más información y ayuda sobre el funcionamiento. Compatible DirecciónSeparación (Extracción)Contacto (Aproximación) Y5145 X+2019 X-2322 Z7668 Superficie no metálica Distancia de detecciónEn función de la tabla de rendimiento de detección de imanes Protección antimanipulaciónFrontal, Trasero Entrada de alarma2 Piloto ledAzul (alarma) Frecuencia de transmisión433 MHz Alcance de transmisión1000 m (área abierta) Tipo de batería1x CR123A Duración promedio de la batería5 años Temperatura de funcionamiento-20 °C a 60 °C (-4 °F a 140 °F) Temperatura de almacenamiento-30 °C a 65 °C (-22 °F a 149 °F) Humedad de funcionamiento10 % a 90 % Dimensiones Sensor: 40,5 mm × 146 mm × 40,9 mm Vara magnética: 30,5 mm × 146 mm × 40,9 mm Peso247 g Escenarios de aplicaciónExteriores, IP66 APRESENTAÇÃO 1. Bastão magnético 2. Sensor 3. Bateria 4. Interruptor 5. Botão de violação 6. Indicador 7. Entrada externa 8. Placa antiviolação traseira 9. Marca de posicionamento REGISTRO TESTE Verifique se a posição de instalação está correta. Tabela de desempenho de detecção do magneto Português 1 4 2 Especificações Manual do usuário 3 Leia o código QR para mais informações e ajuda na operação. INSTALAÇÃO I. Verifique a intensidade do sinal. II. Instale o detector. Parafuso para painel antiviolação traseiro III(Opcional) passe o cabo de entrada através do orifício para cabos se forem necessárias entradas externas. Suporta Direction (Direção)Romper (Remover)Fazer (Aproximar) Y5145 X+2019 X-2322 Z7668 Superfície não metálica Detecção de folgaDe acordo com a tabela de desempenho de detecção do magneto Proteção antiviolaçãoPartes frontal e traseira Entrada de alarme2 Indicador LEDAzul (alarme) Frequência de transmissão433 MHz Intervalo de transmissão1000 m (espaço aberto) Tipo de bateriaCR123A × 1 Duração padrão da bateria5 anos Temperatura de operação-20 °C a 60 °C (-4 °F a 140 °F) Temperatura de armazenamento-30 °C a 65 °C (-22 °F a 149 °F) Umidade de operação10% a 90% Dimensões (L x A x P) Sensor: 40,5 mm × 146 mm × 40,9 mm Bastão magnético: 30,5mm × 146mm × 40,9 mm Peso247 g Cenário de aplicaçãoExterno, IP66 တပ္ဆင္ျခင္း I. လိႈင္းအခ်က္ျပအား စစ္ေဆးပါ။ II. ရွာေဖြစက္ တပ္ဆင္ပါ။ ပန္နယ္ အမွတ္တမဲ့ျဖစ္ရပ္ ကာကြယ္ျခင္းအတြက္ ဝက္အူ III. (မပါဝင္သည္လည္းရွိႏိုင္သည္) အကယ္၍ ျပင္ပထည့္သြင္းမႈမ်ား လိုအပ္ပါက အဝင္ႀကိဳးကို ႀကိဳးေ ပါက္မွတဆင့္ လမ္းေၾကာင္းေပးပါ။ အသြင္အျပင္လကၡဏာ 1. သံလိုက္ေခ်ာင္း 2. အာ႐ံုခံ 3. ဘက္ထရီ 4. ပါဝါခလုတ္ 5. အတားအဆီးထိန္း ခလုတ္ 6. ညႊန္ျပမီး 7. ျပင္ပမွ ထည့္သြင္းမႈ 8. ေနာက္ဘက္ အထိန္းျပား 9. အေနအထား အမွတ္အသား စာရင္းသြင္းျခင္း စစ္ေဆးျခင္း တပ္ဆင္မႈ အေနအထားသည္ သင့္ေလ်ာ္မႈ ရွိ/မရွိ စစ္ေဆးပါ။ သံလိုက္ရွာေဖြေတြ႕ရွိမႈ စြမ္းေဆာင္ရည္ ဇယား ျမန္မာ 1 4 2 အေသးစိတ္ အခ်က္အလက္ သံုးစြဲသူလက္စြဲ 3 ေနာက္ထပ္အခ်က္အလက္မ်ားႏွင့္ လုပ္ေဆာင္မႈ အကူအညီအတြက္ QR ကုဒ္ကို စကန္ဖတ္ပါ။ ေထာက္ပံ့မႈမ်ား ဦးတည္ခ်က္ဘရိတ္(ဖယ္ရွားရန္)ျပဳလုပ္ျခင္း(ခ်ဥ္းကပ္ရန္) Y5145 X+2019 X-2322 Z7668 သတၱဳမဟုတ္ေသာ မ်က္ႏွာျပင္ ရွာေဖြျခင္း ကြာဟခ်က္သံလိုက္ရွာေဖြေတြ႕ရွိမႈ စြမ္းေဆာင္ရည္ ဇယားအရ အမွတ္တမဲ့ျဖစ္မႈမွ ကာကြယ္ျခင္းေရွ႕ဘက္၊ ေနာက္ဘက္ သတိေပးခ်က္ အဝင္2 LED အညႊန္းမီးအျပာေရာင္(သတိေပးခ်က္) ထုတ္လႊတ္သည့္ ဖရီကြင္စီ433MHz ထုတ္လႊတ္မႈ အပိုင္းအျခား1000m (အဖြင့္ ဧရိယာ) ဘက္ထရီ အမ်ိဳးအစားCR123A × 1 စံဘက္ထရီသက္တမ္း5 ႏွစ္ လုပ္ေဆာင္ရန္ အပူခ်ိန္-20 °C မွ 60 °C(-4 °F မွ 140 °F) သိမ္းဆည္းရန္ အပူခ်ိန္-30 °C မွ 65 °C (-22 °F မွ 149 °F) လုပ္ေဆာင္ရန္ စိုထိုင္းဆ10% မွ 90% အတိုင္းအတာ(WxHxD) အာ႐ံုခံ- 40.5 mm × 146 mm × 40.9 mm သံလိုက္ေခ်ာင္း- 30.5mm × 146mm × 40.9 mm အေလးခ်ိန္247 g ပစၥည္းအသံုးျပဳေနရာအျပင္ဘက္၊ IP66 NAMESTITEV I. Preverite moč signala. II. Namestite detektor. Privijte za pravo zaščito pred modifikacijami. IIIČe potrebujete zunanje vhode, vhodni kabel speljite skozi luknjo za kabel (izbirno). PREGLED NAPRAVE 1. Magnetna palica 2. Senzor 3. Baterija 4. Stikalo za vklop/izklop 5. Gumb za urejanje 6. Indikator 7. Zunanji vhod 8. Zaščitni list zadaj 9. Oznaka za določanje položaja VPIS PREIZKUS Preverite, ali je položaj namestitve pravilen. Tabela zmogljivosti zaznavanja magnetnega polja Slovenščina 1 4 2 Tehnični podatki Uporabniški priročnik 3 Če želite več informacij in pomoč pri delovanju, optično preberite kodo QR. Nosilci SmerZlom (odstranitev)Izvedba (pristop) Y5145 X+2019 X-2322 Z7668 Nekovinska površina Zaznavna vrzelGlede na tabelo zmogljivosti zaznavanja magnetnega polja Zaščita pred modifikacijamiSpredaj, zadaj Vhod za alarm2 Indikator LEDModer (alarm) Frekvenca prenosa433 MHz Območje prenosa1000 m (na odprtem območju) Vrsta baterijeCR123A × 1 Življenjska doba standardne baterije5 let Razpon temperature pri delovanjuod –20 °C do 60 °C (od –4 °F do 140 °F) Temperatura skladiščenjaod –30 °C do 65 °C (od -22 °F do 149 °F) Razpon vlage pri delovanjuOd 10 do 90 % Mere (Š x V x G) Senzor: 40,5 mm × 146 mm × 40,9 mm Magnetna palica: 30,5 mm × 146 mm × 40,9 mm Teža247 g Primer uporabeZunaj, IP66 1 3 2 Wireless External Magnet Detector Quick Start Guide User Manual 4 1 1 2 3 4 5 6 9 7 I II III 23 4 Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China xxxx 3 min Device Signal Strength Test 8 DS-PDMCX-E-WB 5. Tamper Button 6. Indicator Magnet Detection Performance Table Check if the installation position is properly. 3. Battery1. Magnetic Stick 4. Power Switch INSTALLATION English APPEARANCE 1 4 ENROLLMENT TEST 2 7. External Input8. Rear Tamper Sheet9. Positioning Mark 2. Sensor Specification User Manual 3 Scan the QR code for more…

Text truncated - open the document above for the full version.

Cover Letter(s)

QF094234 Page 1 of 1 Revision 0 Authority to Act as Agent Date: _2020-10-20_______ TUV Rheinland Group 762 Park Avenue Youngsville, NC 27596 To Whom It May Concern: I appoint TUV Rheinland (Shenzhen) Co., Ltd Mr Bell Hu to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: _____ 12 months____ By: Xiuying Zhang (Signature) (Print name) Title: ____ Telephone On behalf of: Hangzhou Hikvision Digital Technology Co.,Ltd. (Company Name)

Cover Letter(s)

Confidentiality Letter Date: 2020-10-20 Subject: Confidentiality Request Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term Permanent External Photos Short Term Permanent Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Part List/Tune-Up Procedure Short Term Permanent Schematics Short Term Permanent Test Setup Photos Short Term Permanent User’s Manual Hangzhou Hikvision Digital Technology Co.,Ltd. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04- 1705. Sincerely, By: (Signature/Title) (Print name)

External Photos

External Photo Product: Wireless External Magnet Detector Type Designation: DS-PDMCX-E-WB Rev. 0 External Photo Product: Wireless External Magnet Detector Type Designation: DS-PDMCX-E-WB Rev. 0

ID Label/Location Info

FCC ID: 2ADTD-D2676091 Label and Label Location

Internal Photos

Internal Photo Photo Documentation Product: Wireless External Magnet Detector Type Designation: DS-PDMCX-E-WB Rev. 0 Internal Photo Photo Documentation Product: Wireless External Magnet Detector Type Designation: DS-PDMCX-E-WB Rev. 0

RF Exposure Info

FCC ID: 2ADTD-D2676091 Radio Frequency Exposure Compliance RESULT: Pass Test Specification Test standard : CFR47 FCC Part 2.1093 Limit : FCC KDB Publication 447498 D01 v06 Measurement Record for CFR47 FCC Part 2.1093 The minimum distance for the EUT is less than 5mm. The maximum specified e.r.p.: 69.24dBuV/m@3m=-28.17dBm=0.002mW According to KDB 447498 D01 v06 appendix A Exempted Power for this device: 22mW, hence the EUT is compliance with the RF exposure.

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN20NAKC 001 Auftrags-Nr.: Order no.: 168290231 Seite 1 von 17 Page 1 of 17 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2020-11-12 Auftraggeber: Client: Hangzhou Hikvision Digital Technology Co., Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Prüfgegenstand: Test item: Wireless External Magnet Detector Bezeichnung / Typ-Nr.: Identification / Type no.: DS-PDMCX-E-WB, DS-PDMCX-E-WBUHK, DS-PDMCX-E-WBCKV, DS-PDMCX-E- WBUVS, DS-PDMCX-E-WBKVO, DS-PDMCX-E-WBHUN Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: FCC 47 CFR Part 15.203 FCC 47 CFR Part 15.231 FCC 47 CFR Part 2.1093 Wareneingangsdatum: Date of sample receipt: 2020-12-20 Refer to Photo Documentation Prüfmuster-Nr.: Test sample no: A002945360-002, 003 Prüfzeitraum: Testing period: 2020-12-21 to 2020-12-24 Ort der Prüfung: Place of testing: Refer to section 2.1 Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2020-12-28 Ausstellungsdatum: Issue date: 2020-12-28 Stellung / Position: Sachverständige(r) / Expert Stellung / Position: Sachverständige(r) / Expert Sonstiges / Other: FCC ID: 2ADTD-D2676091 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (Shenzhen) Co., Ltd. 1601 R&D Room, 1602-1604, 17-18F, Building 7 Site C, Vanke Cloud City Phase I, Xingke First Street, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P.R. China Mail: [email protected] · Web: www.tuv.com jjj Hardy Suo Sam Lin Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No. CN20NAKC 001 Seite 2 von 17 Page 2 of 17 TEST SUMMARY 5.1.1 Antenna Requirement RESULT: Pass 5.1.2 Deactivation of the Transmission RESULT: Pass 5.1.3 20dB Emission Bandwidth RESULT: Pass 5.1.4 Field strength of fundamental and Unwanted Emissions in the Spurious Domain RESULT: Pass 5.1.5 Radio Frequency Exposure Compliance RESULT: Pass Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No. CN20NAKC 001 Seite 3 von 17 Page 3 of 17 CONTENTS 1. GENERAL REMARKS ............................................................................................................ 4 1.1 COMPLEMENTARY MATERIALS ........................................................................................ 4 1.2 TEST STANDARD(S) ....................................................................................................... 4 2. TEST SITES ......................................................................................................................... 4 2.1 TEST FACILITIES ............................................................................................................ 4 2.2 TEST DATE ................................................................................................................... 4 2.3 LIST OF TEST AND MEASUREMENT INSTRUMENTS ............................................................ 5 2.4 TRACEABILITY ............................................................................................................... 6 2.5 CALIBRATION ................................................................................................................ 6 2.6 LOCATION OF ORIGINAL DATA ........................................................................................ 6 2.7 STATUS OF FACILITY USED FOR TESTING ........................................................................ 6 3. GENERAL PRODUCT INFORMATION ....................................................................................... 7 3.1 PRODUCT FUNCTION AND INTENDED USE ....................................................................... 7 3.2 RATINGS AND SYSTEM DETAILS...................................................................................... 7 3.3 INDEPENDENT OPERATION MODES ................................................................................. 7 3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .................................................... 8 3.5 SUBMITTED DOCUMENTS ............................................................................................... 8 4. TEST SET-UP AND OPERATION MODES ................................................................................. 9 4.1 PRINCIPLE OF CONFIGURATION SELECTION ..................................................................... 9 4.2 TEST OPERATION AND TEST SOFTWARE ......................................................................... 9 4.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ........................................................ 9 4.4 COUNTERMEASURES TO ACHIEVE ERM COMPLIANCE ..................................................... 9 4.5 TEST SETUP DIAGRAM ................................................................................................. 10 5. TEST RESULTS ....................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Long Cheng
[email protected]+8618969187825Fax: +86-571-87356146

Technical Contact

TUV Rheinland (Shenzhen) Co., LtdHardy Suo
[email protected]

Shenzhen · China

Test Firm

TUV Rheinland (Shenzhen) Co., Ltd.Gina Yang
[email protected]86 755 8268 1497

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.1 MHz - 433.7 MHz-
Confidentiality
Long Term

Other Applications from Hangzhou Hikvision Digital Technology Co., Ltd.

Ethernet Switch - FCC ID 2ADTD-3WR15X - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-3WR15X

Ethernet Switch

Nov 09, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Face Recognition Terminal - FCC ID 2ADTD-K1T321MFWX - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-K1T321MFWX

Face Recognition Terminal

Nov 09, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Face Recognition Terminal - FCC ID 2ADTD-K1T6QTF43EFW - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-K1T6QTF43EFW

Face Recognition Terminal

Nov 08, 2022

Equipment Class

DTS - Digital Transmission System
Stand Pole - FCC ID 2ADTD-K7CRT01E - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-K7CRT01E

Stand Pole

Nov 08, 2022

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Face Recognition Terminal - FCC ID 2ADTD-K1T321MFX - Hangzhou Hikvision Digital Technology Co., Ltd.
2ADTD-K1T321MFX

Face Recognition Terminal

Nov 08, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter