Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 UserManual MobilePhone Model : B1f Hereby,TECNOMOBILELIMITED declaresthatthisMobilePhoneisin compliancewiththeessential requirementsandotherrelevant provisionsofDirective2014/53/EU. 2 Knowyourphone 1. Frontcamera 2. Volumekey 3. Powerkey 3 SIM/SDcardinstallation 1.Poweroffmobile. 2.RefertothefollowingpictureforSIM/SDcard installation. 4 Chargingthephone Youcanchargeyourdeviceusingachargerorbyconnecting it to the computer using a USB cable (comes with the phone). 1.Pleaseremindthefrontandbackoftheplug. 2.UseonlyTECNOchargerandcables.Otherchargersor cablesmaydamagethedevice.Thiswillinvalidateyour phonewarranty. 5 OperatingFrequencyBand(RF) : E-GSM900:880-915MHz(TX),925-960MHz(RX) DCS1800:1710-1785MHz(TX),1805-1880MHz(RX) WCDMABANDI:1920-1980MHz(TX),2110-2170MHz(RX) WCDMABANDVIII:880-915MHz(TX),925-960MHz(RX) Bluetooth:2402-2480MHz(TX/RX) Wi-Fi:2412-2472MHz(TX/RX) Modulationmode : GMSK,8PSK(GSM) BPSK,QPSK,16-QAM(WCDMA) GFSK,π/4-DQPSK,8DPSK(BT) GFSK(BLE) CCKforIEEE802.11b(WiFi) OFDMforIEEE802.11g/n(HT-20) 6 RFoutputpower : GSM900:33dBm ± 2dB GSM1800:30dBm ± 2dB WCDMABANDI/VIII:24dBm+1.7dB/-3.7dB Bluetooth:0-10dBm Wifi:14dBm+/-3.0dB SpecificAbsorptionRate(SAR)Certification THIS DEVICE MEETS INTERNATIONAL GUIDELINES FOR EXPOSURE TORADIOWAVES Bodyparts TestvalueTestdistance Limit Head0.352W/Kg10g 0cm2.0W/Kg10g Body0.691W/Kg10g 0.5cm2.0W/Kg10g 7 CAUTION : 1. Use careful with the earphone maybe excessive sound pressure from earphonesandheadphonescancausehearingloss. 2. Riskof explosion ifbattery isreplacedby an incorrecttype, disposeof usedbatteriesaccordingtotheinstructions. 3. Theproductshall onlybeconnectedtoa USBinterface of version USB 2.0. 4. Adapter shall be installed near the equipment and shall be easily accessible. 5.EUTTemperature:-10 °C~ +55 °C . 6.Adapter1:CU-50AT Input:AC100~240V50/60Hz200mA Output:DC5.0V1.0A Adapter2:CU-50ZT Input:AC100~240V50/60Hz200mA Output:DC5.0V1.0A Adapter3:CU-52AT Input:AC100~240V50/60Hz200mA Output:DC5.0V1.2A 7. The device complies with RF specifications when the device used at 5 mmfromyourbody,andtheholdermustnotbeofmetalcomposition. 8. To prevent possible hearing damage, do not listen at high volume levelsforlongperiods. 9.EarphoneandUSBcableareshielded. FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. SAR Informa tion Statement Your wireles s phone is a radio tran smitter and receiver. It is designed and manufa ctured not to exceed the emission limits for ex posure to radiofreque ncy (RF) energy set b y the Federal Communica tions Commission of th e U.S. Government. Th ese limits are part of c omprehensive guidelines a nd establish permitted l evels of RF energy for t he general population. T he guidelines are based o n standards that were developed by indepen dent scientificorganization s through periodic and thorough evaluation o f scientific studies. The standards include a sub stantial safety margin desig ned to assure the safe ty of all persons, regard less of age and health. The exposure standard fo r wireless mobile phon es employs a unit of measurement know n as the Specific Absorp tion Rate, o r SAR. The SAR limit se t by the FCC is 1.6 W/kg . * Tests for SAR are co nducted with t he phone t ransmitting at its highe st certified power level in all teste d frequency bands. Althou gh the SAR is determined at the high est certified power leve l, the actua l SAR level of the phone while oper ating can b e well belo w the max imum value . This is be cause the p hone is design ed to opera te at multip le power le vels so as to use only t he power re quired toreach the netwo rk. In gener al, the close r you are to a wireless base station antenna, t he lower th e power outpu t. Before a p hone mode l is available for sale to t he public, it must be te sted and cer tified to the FC C that it doe s not exceed the limit established b y the gover nment adopted requirement for safe exposure. The tests are per formed in positions and locations (e.g., at the ear and worn on the body ) as required by the FCC for each model. The highest SAR value for this model phone when tested for use at the ear is 0.35 W/Kg and when worn on the body, as d escribed in this Body-worn Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 15mm must be maintained between the user’s body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessor…
Text truncated - open the document above for the full version.
Jul 7,2020 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID:2ADYY-B1F Product Name: Mobile Phone Model: B1f Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> Name Yiting Luo Title Company TECNO MOBILE LIMITED
Jul 7,2020 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Qianhai BlueAsia of Technical Serivices(shenzhen) Limited, No 448, BulongRoad,BantianStreet,LonggangDistric (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with TECNO MOBILE LIMITED,ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL (Applicant Name and address) <Signature> Name Yiting Luo Title Company TECNO MOBILE LIMITED
DATE : July 7, 2020 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ADYY-B1F Product Name: Mobile Phone Request for Short-Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission rules, and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705), we hereby request short-term confidentiality for the following items prior to marketing the device.: ⚫ Test Setup Photos ⚫ External Photos ⚫ Internal Photos ⚫ User Manual The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Name: Yiting Luo Title: manager Company: TECNO MOBILE LIMITED
Test Model No. B1f
Test Model No. B1f
Page 1 of36 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] TEST REPORT Product Name : Mobile Phone Brand Mark : TECNO Model No. : B1f FCC ID : 2ADYY-B1F Report Number : BLA-EMC-202006-A5203 Date of Sample Receipt : 2020/6/18 Date of Test : 2020/6/18 to 2020/7/7 Date of Issue : 2020/7/8 Test Standard : 47 CFR Part 15, Subpart B Test Result : Pass Prepared for: TECNO MOBILE LIMITED ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. IOT Test Centre of BlueAsia No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen,China TEL: +86-755-28682673 FAX: +86-755-28682673 Compiled by: Review by: Approved by: Date: 2020/7/8 Report No.: BLA-EMC-202006-A52-03 Page 2 of36 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] REPORT REVISE RECORD Version No. Date Description 00 2020/7/8 Original Report No.: BLA-EMC-202006-A52-03 Page 3 of36 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] TABLE OF CONTENTS 1 TEST SUMMARY ........................................................................................................................................4 2 GENERAL INFORMATION .........................................................................................................................5 3 GENERAL DESCRIPTION OF E.U.T. .........................................................................................................5 4 TEST MODE ................................................................................................................................................6 5 MEASUREMENT UNCERTAINTY ..............................................................................................................6 6 DESCRIPTION OF SUPPORT UNIT...........................................................................................................7 7 LABORATORY LOCATION .........................................................................................................................7 8 TEST INSTRUMENTS LIST ........................................................................................................................8 CONDUCTED EMISSIONS AT MAINS TERMINALS (150KHZ-30MHZ) ...........................................................9 LIMITS ............................................................................................................................................................................... 9 BLOCK DIAGRAM OF TEST SETUP ...................................................................................................................................... 9 PROCEDURE...................................................................................................................................................................... 9 TEST DATA ........................................................................................................................................................................ 10 RADIATED EMISSIONS (ABOVE 1GHZ) ........................................................................................................ 18 LIMITS ............................................................................................................................................................................. 18 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 18 PROCEDURE.................................................................................................................................................................... 18 TEST DATA ........................................................................................................................................................................ 19 RADIATED EMISSIONS (30MHZ-1GHZ) ......................................................................................................... 27 LIMITS ............................................................................................................................................................................. 27 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 27 PROCEDURE.................................................................................................................................................................... 27 TEST DATA ........................................................................................................................................................................ 28 Report No.: BLA-EMC-202006-A52-03 Page 4 of36 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 1 TEST SUMMARY Test item Test Requirement Test Method Class/Severity Result Conducted Emissions at Mains Terminals (150kHz-30MHz) 47 CFR Part 15, Subpart B ANSI C63.4:2014 Class B Pass Radiated Emissions (above 1GHz) 47 CFR Part 15, Subpart B ANSI C63.4:2014 Class B Pass Radiated Emissions (30MHz-1GHz) 47 CFR Part 15, Subpart B ANSI C63.4:2014 Class B Pass Report No.: BLA-EMC-202006-A52-03 Page 5 of36 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of …
Text truncated - open the document above for the full version.
Test Model No. B1f Radiated Spurious Emission Radiated Spurious Emissions Conducted Emissions at AC Power Line (150kHz-30MHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |
Mobile Phone
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterTablet
Equipment Class
DTS - Digital Transmission SystemMobile Phone
Equipment Class
PCE - PCS Licensed Transmitter held to earMobile Phone
Equipment Class
DTS - Digital Transmission SystemTablet
Equipment Class
NII - Unlicensed National Information Infrastructure TX