2ADYY-T1002WTablet

TECNO MOBILE LIMITED

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 10, 2026
Application Purpose
Original Equipment
Equipment Note
Tablet
Frequency Range
2402.00000000 - 2480.00000000
Company
TECNO MOBILE LIMITED
Country
Hong Kong

Documents & Files

Select a file to view

Attestation Statements

โ†—
โ†—
โ†—
โ†—

Cover Letter(s)

โ†—
โ†—

ID Label/Location Info

โ†—

RF Exposure Info

โ†—
โ†—
โ†—
โ†—

Test Report

โ†—
โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

TECNOMOBILELIMITED Address:FLATN16/FBLOCKBUNIVERSALINDUSTRIALCENTRE19-25 SHANMEISTREETFOTANNTHONGKONG Tel.:+86-755-61803856Fax:+86-755-33979211 E-mail:[email protected] AttestationLetter Date:2026-05-18 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 DearSir/Madam, OurproductTablet,model:T1002W,FCCID:2ADYY-T1002W,formarketing purpose,thisproductonlysupportsBDR(GFSK),EDR(ฯ€/4-DQPSK,8DPSK);BLE 1M&2M(BLE2Monlysupport2404-2478MHz);2.4GWi-Fi(2412-2462MHz, 802.11b/g/n20mode);5GWi-Fi(5150-5250MHz,5250-5350MHz,5470-5725MHz, 5725-5850MHz,802.11a/n20/n40/ac20/ac40/ac80mode);GNSS(onlyhasRX functions)andFM(onlyhasRXfunctions),theotherfunctions,bandsandmodes weredisabledtousebymanufactureinthesoftware,theenduserhasnocapabilityto activateit. SincerelyYours, Signature YitingLuo Manager

Attestation Statements

TECNOMOBILELIMITED Address:FLATN16/FBLOCKBUNIVERSALINDUSTRIALCENTRE19-25SHANMEI STREETFOTANNTHONGKONG Tel.:+86-755-61803856Fax:+86-755-33979211 E-mail:[email protected] CFR47ยง2.911(d)(5)(i)AttestationLetter AttestationLetter Date:2026-05-28 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47ยง2.911(d)(5)(i)Filing FCCID:2ADYY-T1002W TECNOMOBILELIMITEDcertifiesthattheequipmentforwhichauthorizationissought, isnotโ€œcoveredโ€equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. SincerelyYours, Signature YitingLuo Manager

Attestation Statements

TECNOMOBILELIMITED Address:FLATN16/FBLOCKBUNIVERSALINDUSTRIALCENTRE19-25SHANMEI STREETFOTANNTHONGKONG Tel.:+86-755-61803856Fax:+86-755-33979211 E-mail:[email protected] CFR47ยง2.911(d)(5)(ii)AttestationLetter AttestationLetter Date:2026-05-28 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47ยง2.911(d)(5)(ii)Filing FCCID:2ADYY-T1002W TECNOMOBILELIMITEDcertifiesthatasofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredListasanentityproducingโ€œcoveredโ€equipment. Wealsocertifythat,asofthedateofthefilingoftheapplication,theequipmentdoesnotutilize cyber-securityoranti-virussoftwarefromKasperskyLab,Inc,oranyofitssuccessorsand assignees,whichisalsoontheโ€œcoveredlistโ€. SincerelyYours, Signature YitingLuo Manager

Attestation Statements

U.S.AGENTLETTEROFATTESTATION Date:2026-05-28 FEDERALCOMMUNICATIONSCOMMISSION AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47ยง2.911(d)(7)Filing FCCID:2ADYY-T1002W TECNOMOBILELIMITEDcertifiesthat,asofthedateofthefilingoftheapplication, IconsighInc.isourdesignatedU.S.agentforserviceofprocessfortheabovereferenced FCCID.TECNOMOBILELIMITEDacceptstomaintainanagentfornolessthanoneyear afterthegranteehasterminatedallmarketingandimportationortheconclusionofany Commission-relatedproceedinginvolvingtheequipment. IconsighInc.accepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: CompanyName:IconsighInc. Address:2310HomesteadRoad,SuiteC1,LosAltos,CA,94024,USA FRN:0033398652 Tel.:+1(408)320-9867 Email:[email protected] Signedby(printedname):BenjaminKaur Signature: Applicant:TECNOMOBILELIMITED Address:FLATN16/FBLOCKBUNIVERSALINDUSTRIALCENTRE19-25SHAN MEISTREETFOTANNTHONGKONG FRN:0024206328 Tel:+86-755-61803856 Email:[email protected] Signedby(printedname):YitingLuo Signature:

Cover Letter(s)

TECNOMOBILELIMITED Address:FLATN16/FBLOCKBUNIVERSALINDUSTRIALCENTRE19-25SHAN MEISTREETFOTANNTHONGKONG Tel.:+86-755-61803856Fax:+86-755-33979211 E-mail:[email protected] QA-FR-170-B FCCAuthorization Date:2026-05-28 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorization Towhomitmayconcern: We,TECNOMOBILELIMITEDherebyauthorizesBayAreaComplianceLaboratories Corp.(Dongguan)toactonitsbehalfinallmattersrelatingtoapplicationforEquipment authorization,includingthesigningofalldocumentsrelatingtothesematters.Allacts carriedoutbyBayAreaComplianceLaboratoriesCorp.(Dongguan)onourbehalfshall havethesameeffectasourownaction. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits, thatincludesFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988, 21U.S.C.862. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. SincerelyYours, Signature YitingLuo Manager

Cover Letter(s)

TECNOMOBILELIMITED Address:FLATN16/FBLOCKBUNIVERSALINDUSTRIALCENTRE19-25SHANMEISTREETFOTANNT HONGKONG Tel.:+86-755-61803856Fax:+86-755-33979211 E-mail:[email protected] FCCConfidentialAuthorization Date:2026-05-28 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestregardingapplicationforcertificationof FCCID:2ADYY-T1002W InaccordancewithSections0.457and0.459oftheCommissionโ€™sRules, TECNOMOBILELIMITEDherebyrequestslong-termconfidentialtreatmentof informationaccompanyingthisapplicationasoutlinedbelow: ๏‚ทBlockDiagram ๏‚ทSchematics ๏‚ทOperationDescription ๏‚ทSoftwareSecurityDescription Aswellasshort-termconfidentialtreatmentofinformationaccompanyingthis applicationforaperiodof180daysaftergrantisissuedasoutlinedbelow: ๏‚ทInternalPhotos ๏‚ทUserโ€™sManual ๏‚ทExternalPhotos ๏‚ทTestSet-upPhotos Theabovematerialscontainproprietaryandconfidentialinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesematerialsprovidesunjustified benefitstoitscompetitorsinthemarket. SincerelyYours, Signature YitingLuo Manager

RF Exposure Info

APPENDIX D - PROBE CALIBRATION CERTIFICATES Report No.: 2602S11904E-20 118 Report No.: 2602S11904E-20 218 Report No.: 2602S11904E-20 318 Report No.: 2602S11904E-20 418 Report No.: 2602S11904E-20 518 Report No.: 2602S11904E-20 618 Report No.: 2602S11904E-20 718 Report No.: 2602S11904E-20 818 Report No.: 2602S11904E-20 918 Report No.: 2602S11904E-20 1018 Report No.: 2602S11904E-20 1118 Report No.: 2602S11904E-20 1218 Report No.: 2602S11904E-20 1318 Report No.: 2602S11904E-20 1418 Report No.: 2602S11904E-20 1518 Report No.: 2602S11904E-20 1618 Report No.: 2602S11904E-20 1718 Report No.: 2602S11904E-20 1818

RF Exposure Info

Report No.: 2602S11904E-20 APPENDIX E - DIPOLE CALIBRATION CERTIFICATES Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20 Report No.: 2602S11904E-20

RF Exposure Info

Report No.: 2602S11904E-20 Page 1 of 2 APPENDIX F - RETURN LOSS AND IMPEDANCE MEASUREMENT D2450V2 - SN:971 Extended Dipole Calibrations Referring to KDB865664 D01, if dipoles are verified in return loss(< -20dB, within 20% of prior calibration), and in impedance(within 5 ohm of prior calibration), the annual calibration is not necessary and the calibration interval can be extended. Test Equipment Information: Equipment Model S/N Calibration Date Calibration Due Date Simulated Tissue Liquid Head HBBL600-10000V6 SL AAH U126 CA (Batch:250429-1) N/A N/A Twin SAM Twin SAM V5.0 1097 NCR NCR Network Analyzer E5071C MY46519680 2024/07/11 2025/07/10 Network Analyzer Calibration Kit 50 โ„ฆ 51026 NCR NCR Justification of the extended calibration D2450V2 - SN:971 2450MHz Head Date of Measurement Return-Loss (dB) Delta (%) Real Impedance (ohm) Delta (ohm) Imaginary Impedance (ohm) Delta (ohm) 2024/6/15 (Cal. Report) -23.0 / 52.3 / 6.84 / 2025/6/10 (Extended) -21.69 5.7%47.66 4.64 7.72 -0.88 The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of prior calibration. Therefore the verification result should support extended calibration. Report No.: 2602S11904E-20 Page 2 of 2 Dipole Verification Data> D2450V2 - SN:971 (Date of Measurement: 2025/6/10) 2450MHz - Head Name Tilt Signature Calibrated By: Mark Dong SAR Engineer Approved By: Brave Lu SAR Supervisor

RF Exposure Info

Report Template Version: FCC SAR-V1.0 Page 1 of 48 FCC SAR TEST REPORT Applicant: TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Product Name: Tablet F C C I D : 2ADYY-T1002W Standard(s): 47 CFR Part 2(2.1093) Report Number: 2602S11904E-20 Report Date: 2026/05/22 The above device has been tested and found compliant with the requirement of the relevantstandards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By:Rocky Xiao Approved By:Brave Lu Title: RF Supervisor Title: SAR Supervisor Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked โ–ฒ is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with โ˜….This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Each test item follows the test standard(s) without deviation. Report Template Version: FCC SAR-V1.0 Page 2 of 48 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2602S11904E-20 SAR TEST RESULTS SUMMARY Body SAR: Mode Max. Reported SAR Level(s) (W/kg) Limit (W/kg) WLAN 2.4G 1g Body SAR 1.48 1.6 WLAN 5.2G 1g Body SAR 0.60 WLAN 5.3G 1g Body SAR 0.69 WLAN 5.6G 1g Body SAR 0.79 WLAN 5.8G 1g Body SAR 0.72 Applicable Standards FCC 47 CFR part 2.1093 Radiofrequency radiation exposure evaluation: portable devices IEEE1528:2013 IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques RF Exposure Procedures: TCB WorkshopApril2019 KDB procedures KDB 447498 D01 General RF Exposure Guidance v06 KDB 616217 D04 SAR for laptop and tablets v01r02 KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04 KDB 865664 D02 RF Exposure Reporting v01r02 KDB 248227 D01 802.11 Wi-Fi SAR v02r02 Note: This wireless device has been shown to be capable of compliance for localized specific absorption rate (SAR) for General Population/Uncontrolled Exposure limits specified in FCC 47 CFR part 2.1093 and has been tested in accordance with the measurement procedures specified in IEEE 1528-2013 and RF exposure KDB procedures. The results and statements contained in this report pertain only to the device(s) evaluated. Report Template Version: FCC SAR-V1.0 Page 3 of 48 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2602S11904E-20 CONTENTS SAR TEST RESULTS SUMMARY ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 2 DOCUMENT REVISION HISTORY ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1. GENERAL INFORMATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 2. REFERENCE, STANDARDS, AND GUIDELINES ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 2.1 SAR LIMITS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 2.2 TEST FACILITY ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 3. DESCRIPTION OF TEST SYSTEM ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 4. EQUIPMENT LIST AND CALIBRATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 4.1 EQUIPMENTS LIST & CALIBRATION INFORMATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 5. SAR MEASUREMENT SYSTEM VERIFICATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 5.1 LIQUID VERIFICATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 5.2 LIQUID VERIFICATION RESULTS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 5.3 SYSTEM ACCURACY VERIFICATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 17 5.4 SYSTEM ACCURACY CHECK RESULTS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 17 5.5 SAR SYSTEM VALIDATION DATA ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 6. EUT TEST STRATEGY AND METHODOLOGY ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 22 6.1TEST POSITIONS FOR BODY-WORN AND OTHER CONFIGURATIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 22 6.2TEST DISTANCE FOR SAR EVALUATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 22 7. CONDUCTED OUTPUT POWER MEASUREMENT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 23 7.1 TEST PROCEDURE ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 23 7.2 MAXIMUM TARGET OUTPUT POWER ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 24 7.3 TEST RESULTS: ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 25 8. STANDALONE SAR TEST EXCLUSION CONSIDERATIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 28 8.1 ANTENNAS LOCATION: ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 28 8.2 ANTENNA DISTANCE TO EDGE ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 28 8.3 STANDALONE SAR TEST EXCLUSION CONSIDERATIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 28 8.4 SAR TEST EXCLUSION FOR THE EUT EDGE CONSIDERATIONS RESULT ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 29 9. SAR MEASUREMENT RESULTS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 30 9.1 SAR TESTโ€ฆ

Text truncated - open the document above for the full version.

Test Report

Frequency Band: GPS๏ผš1575.42MHz; 2.4GWIFI๏ผš2400-2500MHz; 5GWIFI๏ผš5150-5850MHz; BT/2.4GWIFI/GPS Antenna type๏ผšPIFA๏ผ›(Antenna Model: T1002W ANT1) 5GWIFI Antenna type๏ผšPCB monopole๏ผ›(Antenna Model: T1002W ANT3) BT/2.4GWIFI/GPS antenna๏ผš VSWR๏ผš RL๏ผš SMITH๏ผš BT/2.4GWIFI/GPS Antenna gain๏ผš BT/2.4GWIFI: 0dBi; GPS: -1dBi; 5G WIFI antenna๏ผš VSWR๏ผš RL๏ผš SIMITH๏ผš 5GWIFI Antenna gain๏ผš 5G WIFI average: -1.5dBi; 2.4GWIFI/BT 2D/3D: 5GWIFI 2D/3D: ๅˆถ้€ ๅ•†๏ผš Manufacturer: ๆ˜†ๅฑฑ็ฟ็ฟ”่ฎฏ้€š้€šไฟกๆŠ€ๆœฏๆœ‰้™ๅ…ฌๅธ ๏ผˆKunshan Ruixiang Xuntong Communication Technology Co., Ltd. .๏ผ‰ ๅœฐๅ€:ๆฑŸ่‹็œๆ˜†ๅฑฑๅธ‚็މๅฑฑ้•‡็››ๅˆ›่ทฏ 55 ๅท้‡‘ๅœŸๅœฐๆ™บ้€ ๅ›ญ H ๆ ‹ (Add: Building H, Jintudi Intelligent Manufacturing Park, No. 55 Shengchuang Road, Yushan Town, Kunshan City, Jiangsu Province.) Antenna Location:

Test Report

Report Template Version: FCC-BLE-V2.4 Page 1 of 56 TEST REPORT Applicant: TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Product Name: Tablet FCC ID: 2ADYY-T1002W Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2020 KDB 558074 D01 15.247 Meas Guidance v05r02 Report Number: 2602S11904E-RF-00B Report Date: 2026/6/8 The above device has been tested and found compliant with the requirement of the relevant standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Alice Tan Approved By: Pedro Yun Title: RF Engineer Title: RF Supervisor Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked โ–ฒ is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with โ˜….This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Each test item follows the test standard(s) without deviation. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.:2602S11904E-RF-00B Report Template Version: FCC-BLE-V2.4 Page 2 of 56 CONTENTS DOCUMENT REVISION HISTORY ................................................................................................. 4 1. GENERAL INFORMATION ........................................................................................................... 5 1.1 GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST ............................................................................ 5 1.2 ACCESSORY INFORMATION ........................................................................................................................ 5 1.3 ANTENNA INFORMATION DETAILโ–ฒ .......................................................................................................... 5 1.4 EQUIPMENT MODIFICATIONS ..................................................................................................................... 5 2. SUMMARY OF TEST RESULTS ................................................................................................... 6 3. DESCRIPTION OF TEST CONFIGURATION ............................................................................ 7 3.1 OPERATION FREQUENCY DETAIL .............................................................................................................. 7 3.2 EUT OPERATION CONDITION .................................................................................................................... 7 3.3 SUPPORT EQUIPMENT LIST AND DETAILS ................................................................................................. 7 3.4 SUPPORT CABLE LIST AND DETAILS .......................................................................................................... 8 3.5 BLOCK DIAGRAM OF TEST SETUP .............................................................................................................. 9 3.6 TEST FACILITY .......................................................................................................................................... 11 3.7 MEASUREMENT UNCERTAINTY ................................................................................................................ 11 4. REQUIREMENTS AND TEST PROCEDURES ......................................................................... 12 4.1 AC LINE CONDUCTED EMISSIONS ........................................................................................................... 12 4.1.1 Applicable Standard ............................................................................................................................................ 12 4.1.2 EUT Setup ........................................................................................................................................................... 13 4.1.3 EMI Test Receiver Setup .................................................................................................................................... 13 4.1.4 Test Procedure ..................................................................................................................................................... 14 4.1.5 Corrected Result& Margin Calculation ............................................................................................................... 14 4.1.6 Test Result ........................................................................................................................................................... 14 4.2 RADIATION SPURIOUS EMISSIONS ............................................................................................................ 15 4.2.1 Applicable Standard ............................................................................................................................................ 15 4.2.2 EUT Setup ........................................................................................................................................................... 15 4.2.3 EMI Test Receiver & Spectrum Analyzer Setup ................................................................................................. 17 4.2.4 Test Procedure ..................................................................................................................................................... 17โ€ฆ

Text truncated - open the document above for the full version.

Test Report

Report Template Version: FCC-Wi-Fi-V2.4 Page 1 of 65 TEST REPORT Applicant: TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Product Name: Tablet FCC ID: 2ADYY-T1002W Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2020 KDB 558074 D01 15.247 Meas Guidance v05r02 Report Number: 2602S11904E-RF-00C Report Date: 2026/6/8 The above device has been tested and found compliant with the requirement of the relevant standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Alice Tan Approved By: Pedro Yun Title: RF Engineer Title: RF Supervisor Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked โ–ฒ is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with โ˜….This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Each test item follows the test standard(s) without deviation. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2602S11904E-RF-00C Report Template Version: FCC-Wi-Fi-V2.4 Page 2 of 65 CONTENTS DOCUMENT REVISION HISTORY ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 1. GENERAL INFORMATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.2 ACCESSORY INFORMATIONยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.3 ANTENNA INFORMATION DETAILโ–ฒ ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.4 EQUIPMENT MODIFICATIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 2. SUMMARY OF TEST RESULTS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 3. DESCRIPTION OF TEST CONFIGURATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 3.1 OPERATION FREQUENCY DETAIL ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 3.2 EUT OPERATION CONDITION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 3.3 SUPPORT EQUIPMENT LIST AND DETAILS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 3.4 SUPPORT CABLE LIST AND DETAILS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 3.5 BLOCK DIAGRAM OF TEST SETUP ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 3.6 TEST FACILITY ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 3.7 MEASUREMENT UNCERTAINTY ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 4. REQUIREMENTS AND TEST PROCEDURES ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 4.1 AC LINE CONDUCTED EMISSIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 4.1.1 Applicable Standard ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 4.1.2 EUT Setup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 4.1.3 EMI Test Receiver Setup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 4.1.4 Test Procedure ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 13 4.1.5 Corrected Amplitude & Margin Calculation ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 13 4.1.6 Test Result ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 13 4.2 RADIATION SPURIOUS EMISSIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 4.2.1 Applicable Standard ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 4.2.2 EUT Setup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 4.2.3 EMI Test Receiver & Spectrum Analyzer Setup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 4.2.4 Test Procedure ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 4.2.5 Corrected Result& Margin Calculation ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 4.2.6 Test Result ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 17 4.3 MINIMUM 6 DB EMISSION BANDWIDTH ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 4.3.1 Applicable Standard ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 4.3.2 EUT Setup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 4.3.3 Test Procedure ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 4.3.4 Test Result ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yiting Luo
[email protected]Fax: +86-755-33979211

Technical Contact

IconsighBenjamin Kaur
[email protected]

2310 Homestead Road Suite C1 ยท Los Altos, California, 94024 ยท United States

Test Firm

Bay Area Compliance Laboratories Corp. (Dongguan)David Zhang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz97.00 mW
215C2.40 GHz - 2.48 GHz600.00 ยตW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted. The antenna(s) used for this transmitter must not be co-located with any other transmitters, except in accordance with FCC multi-transmitter product procedures. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory condition is 1.48 W/kg.

Other Applications from TECNO MOBILE LIMITED

2ADYY-KO2

Mobile Phone

Sep 16, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ADYY-KN4N

Mobile Phone

Jun 08, 2026

Equipment Class

PCE - PCS Licensed Transmitter held to ear
2ADYY-CN6

Mobile Phone

Jun 05, 2026

Equipment Class

DTS - Digital Transmission System
2ADYY-T1103

Tablet

May 25, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2ADYY-T1002

Tablet

May 25, 2026

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral