FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TECNO MOBILE LIMITED/
  3. 2ADYY-KD6

2ADYY-KD6Mobile Phone

TECNO MOBILE LIMITED
Mobile Phone - FCC ID 2ADYY-KD6 - TECNO MOBILE LIMITED
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Apr 20, 2020
Application Purpose
Original Equipment
Date of Application
Apr 20, 2020
Equipment Note
Mobile Phone
Frequency Range
5745.00000000 - 5825.00000000
Company
TECNO MOBILE LIMITED
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TECNO KD6 User Manual FCC ID: 2ADYY-KD6 TECNO MOBILE LIMITED E E x x p p l l o o s s i i o o n n d d i i a a g g r r a a m m s s p p e e c c i i f f i i c c a a t t i i o o n n 1 FL(CTP+LCM) 6.95HD+ LC7 Black TCL V1.0 2 LT sensor light guide KD6 3 F flash lens KD6 4 F hsg KD6 Black PC+20%GF 5 8W R CAM 6 R flash Lens KD6 7 I 3M R CAM 8 Rec Deco KD6 9 8M F CAM 10REC KD6 11 F CAM rubber KD6 12REC support steel 13 R CAM 8W rubber KD6 14MAIN PCBA KD6 15 FINGER PRINT KD6 16SCREW L2.5 17 UP FRAME KD6 18SCREW L3.5 19 R CAM Lens KD6 20Bat cover KD6 21 DOWN FRAME KD6 22SUB PCBA KD6 23 BATTERY KD6 24EARJACK RUBBER KD6 25 MOTOR KD6 26SIDE KEY FPC 27 USB RUBBER KD6 28Card holder KD6 29 FP STEEL KD6 30RF LINE KD6 31 SIDE KEY KD6 Know your phone 1. Front camera 2. Volume key 3. Power key SIM/SD card installation 1. Power off mobile. 2. Refer to the following picture for SIM / SD card installation. Charging the phone You can charge your device using a charger or by connecting it to the computer using a USB cable (comes with the phone). 1. Please remind the front and back of the plug. 2. Use only TECNO charger and cables. Other chargers or cables may damage the device. This will invalidate your phone warranty. Emergency call If any emergency arises, dial 112/911 (or other emergency call number) for emergency help. Due to the nature of cellular networking, the success of emergency call is not guaranteed. FCC Warning: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types KD6 (FCC ID: 2ADYY-KD6) has also been tested against this SAR limit. The highest reported SAR values for head, body-worn accessory, and product specific (Hotspot) are 1.08 W/kg, 0.49 W/kg, and 0.70 W/kg respectively. The Max simultaneous SAR is 1.34W/kg. This device was tested for typical body-worn operations with the back of the handset kept 10mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain a 10mm separation distance between the user's body and the back of the handset. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided.

Attestation Statements

TECNO MOBILE LIMITED Date: 2020-04-17 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ADYY-KD6 To Whom It May Concern: This letter is to statement that KD6 / Mobile Phone. has been tested according to FCC Part 15B by Waltek Services (Shenzhen) Co., Ltd. (Test Report No.: WTS20S03012203E). And the SDOC file, meetting the requirements of the FCC regulations, would been provided when the device is sold by the responsible party in US. The service will not be sold until the SDOC is provided. If the sale does not have an SDOC, all responsibility is the responsibility of the applicant. Sincerely, Signature [Yiting Luo] [Manager] [TECNO MOBILE LIMITED]

Cover Letter(s)

TECNO MOBILE LIMITED Date: Apr. 17, 2020 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2ADYY-KD6 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Long-term confidentilality: Schematics Block Diagram Operational Description Schematics.pdf Block Diagram.pdf Operational Description.pdf Part List Part Placement Schematics PCB Layout Schematics Tune-up Procedure Short-term confidentilality: External Photos User’s Manual Internal Photos Setup photos DSS DTS Setup photos PCE Setup photos NII Setup photos SAR Part List.pdf Part Placement Schematics.pdf PCB Layout Schematics.pdf Tune-up Procedure.pdf External Photos.pdf User’s Manual.pdf Internal Photos.pdf Setup photos DSS DTS.pdf Setup photos PCE.pdf Setup photos NII.pdf Setup photos SAR.pdf Short-term confidentilality days: 180 days. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, TECNO MOBILE LIMITED Signature Yiting Luo / Manager Typed name and Title

Cover Letter(s)

TECNO MOBILE LIMITED Date: 4/17/2020 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD To Whom It May Concern: We, TECNO MOBILE LIMITED, state that our device, FCC ID: 2ADYY-KD6, has a non-detachable battery, the label is visible to the users as they purchase the products and install TF card or SIM cards. The back cover can not be moved away, so the FCC ID label has to be placed on the surface of product. Sincerely, Signature [Yiting Luo (Name)] [Manager (Title)] [TECNO MOBILE LIMITED (Company name)]

Cover Letter(s)

TECNO MOBILE LIMITED FCC ID: 2ADYY-KD6 POWER OF ATTORNEY Date: Apr. 17, 2020 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on Apr. 16, 2021. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, TECNO MOBILE LIMITED are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, TECNO MOBILE LIMITED Signature Yiting Luo / Manager Typed name and Title

External Photos

Appendix-KD6-Photos Page 4 of 20 EUT – External View Model KD6 FCC ID: 2ADYY- KD6 Appendix-KD6-Photos Page 5 of 20 Appendix-KD6-Photos Page 6 of 20 Appendix-KD6-Photos Page 7 of 20 Appendix-KD6-Photos Page 8 of 20

ID Label/Location Info

KD6 Label Sample and Location

Internal Photos

Appendix-KD6-Photos Page 9 of 20 EUT – Internal View Model KD6 FCC ID: 2ADYY- KD6 GSM/WCDMA/LTE ANT. BT/WIFI/GPS ANT. Appendix-KD6-Photos Page 10 of 20 Appendix-KD6-Photos Page 11 of 20 Appendix-KD6-Photos Page 12 of 20 Appendix-KD6-Photos Page 13 of 20 Appendix-KD6-Photos Page 14 of 20

Internal Photos

Appendix-KD6-Photos Page 15 of 20 Appendix-KD6-Photos Page 16 of 20 Appendix-KD6-Photos Page 17 of 20 Appendix-KD6-Photos Page 18 of 20 Appendix-KD6-Photos Page 19 of 20 Appendix-KD6-Photos Page 20 of 20 ======End======

RF Exposure Info

Ref : ACR.233.1.17.SATU.A SHENZHEN SEM TEST TECHNOLOGY CO., LTD. 1/F, BUILDING A, HONGWEI INDUSTRIAL PARK, LIUXIAN 2ND ROAD BAO'AN DISTRICT SHENZHEN (518101), CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: SN 45/15 EPGO280 Calibrated at MVG US 2105 Barrett Park Dr. - Kennesaw, GA 30144 Calibration Date: 07/08/2019 Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed in MVG USA using the CALISAR / CALIBAIR test bench, for use with a COMOSAR system only. All calibration results are traceable to national metrology institutions. COMOSAR E-Field Probe Calibration Report COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 2/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Jérôme LUC Product Manager 7/8/2019 Checked by : Jérôme LUC Product Manager 7/8/2019 Approved by : Kim RUTKOWSKI Quality Manager 7/8/2019 Customer Name Distribution : Shenzhen SEM.Test Technology Co., Ltd. Issue Date Modifications A 7/8/2019 Initial release COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 3/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Linearity ________________________________________________________________ 4 3.2 Sensitivity _______________________________________________________________ 5 3.3 Lower Detection Limit _____________________________________________________ 5 3.4 Isotropy _________________________________________________________________ 5 3.5 Boundary Effect __________________________________________________________ 5 4 Measurement Uncertainty .......................................................................................... 5 5 Calibration Measurement Results .............................................................................. 6 5.1 Sensitivity in air __________________________________________________________ 6 5.2 Linearity ________________________________________________________________ 7 5.3 Sensitivity in liquid ________________________________________________________ 7 5.4 Isotropy _________________________________________________________________ 8 6 List of Equipment .................................................................................................... 10 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 4/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE2 Serial Number SN 45/15 EPGO280 Product Condition (new / used) New Frequency Range of Probe 0.7 GHz-6GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.193 M Dipole 2: R2=0.188 M Dipole 3: R3=0.198 M A yearly calibration interval is recommended. 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOSAR E field Probes are built in accordance to the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards. Figure 1 – MVG COMOSAR Dosimetric E field Dipole Probe Length 330 mm Length of Individual Dipoles 2 mm Maximum external diameter 8 mm Probe Tip External Diameter 2.5 mm Distance between dipoles / probe extremity 1 mm 3 MEASUREMENT METHOD The IEEE 1528, OET 65 Bulletin C, CENELEC EN50361 and CEI/IEC 62209 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their affect. All calibrations / measurements performed meet the fore mentioned standards. 3.1 LINEARITY The evaluation of the linearity was done in free space using the waveguide, performing a power sweep to cover the SAR range 0.01W/kg to 100W/kg. COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 5/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3.2 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards. 3.3 LOWER DETECTION LIMIT The lower detection limit was assessed using the same measurement set up as used for the linearity measurement. The required lower detection limit is 10 mW/kg. 3.4 ISOTROPY The axial isotropy was evaluated by exposing the probe to a reference wave from a standard dipole with the dipole mounted under the flat phantom in the test configuration suggested for system validations and checks. The probe was rotated along its main axis from 0 - 360 degrees in 15 degree steps. The hemispherical isotropy is determined by inserting the probe in a thin plastic box filled with tissue-equivalent liquid, with the plastic box …

Text truncated - open the document above for the full version.

RF Exposure Info

Model: KD6 Report No.: WTS20X04016916W Page 1 of 47 SAR Report FCC ID: 2ADYY-KD6 Test Standards: FCC Part 2.1093 ANSI / IEEE C95.1 :2005+A1:2010 ANSI / IEEE C95.3 : 2002(R2008) IEEE 1528 :2013 Product Description: Mobile Phone Tested Model: KD6 Report No.: WTS20X04016916W Sample Received Date: Mar.30, 2020 Tested Date: Mar.30, 2020 to Apr.13, 2020 Issued Date: Apr.14, 2020 Tested By: Jack Sun / Engineer Reviewed By: Lion Cai / RF Manager Approved & Authorized By: Silin Chen / EMC Manager Prepared By: Shenzhen SEM Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao'an District, Shenzhen, P.R.C.(518101) Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen SEM Test Technology Co., Ltd. FCC SAR Measurement and Test Report For TECNO MOBILE LIMITED ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL, Hong Kong Model: KD6 Report No.: WTS20X04016916W Page 2 of 47 SAR Report TABLE OF CONTENTS 1. General Information ................................................................................................................................................... 3 1.1 Product Description for Equipment Under Test (EUT) ......................................................................................... 3 1.2 Test Standards .................................................................................................................................................... 4 1.3 Test Methodology ................................................................................................................................................ 4 1.4 Test Facility ......................................................................................................................................................... 4 2. Summary of Test Results .......................................................................................................................................... 5 3. Specific Absorption Rate (SAR) ................................................................................................................................ 6 3.1 Introduction .......................................................................................................................................................... 6 3.2 SAR Definition ..................................................................................................................................................... 6 4. SAR Measurement System ........................................................................................................................................ 7 4.1 The Measurement System .................................................................................................................................. 7 4.2 Probe ................................................................................................................................................................... 7 4.3 Probe Calibration Process ................................................................................................................................... 9 4.4 Phantom ............................................................................................................................................................ 10 4.5 Device Holder .................................................................................................................................................... 10 4.6 Test Equipment List ........................................................................................................................................... 11 5. Tissue Simulating Liquids ....................................................................................................................................... 12 5.1 Composition of Tissue Simulating Liquid ........................................................................................................... 12 5.2 Tissue Dielectric Parameters for Head and Body Phantoms ............................................................................. 13 5.3 Tissue Calibration Result ................................................................................................................................... 14 6. SAR Measurement Evaluation ................................................................................................................................ 15 6.1 Purpose of System Performance Check ............................................................................................................ 15 6.2 System Setup .................................................................................................................................................... 15 6.3 Validation Results .............................................................................................................................................. 16 7. EUT Testing Position ............................................................................................................................................... 17 7.1 Define Two Imaginary Lines on The Handset .................................................................................................... 17 7.2 Cheek Position .................................................................................................................................................. 18 7.3 Tilted Position .................................................................................................................................................... 18 7.4 Body Position .................................................................................................................................................... 19 7.5 EUT Antenna Position .............................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Page 1 of 186 SAR TEST REPORT Reference No. ................... : WTS20S03012207W001 V1 FCC ID ................................ : 2ADYY-KD6 Applicant ........................... : TECNO MOBILE LIMITED Address ............................. : ROOM 604 6/F SOUTH TOWER WORLD, FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL, Hong Kong Manufacturer .................... : SHENZHEN TECNO TECHNOLOGY CO.,LTD. Address ............................. : 101, Building 24, Waijing Industrial Park, Fumin Community, Fucheng Street, Longhua District, Shenzhen City, P.R. China Product .............................. : Mobile Phone Model(s).. ........................... : KD6 Brand Name. ..................... : TECNO Standards .......................... : FCC 47 CFR Part2(2.1093) ANSI/IEEE C95.1-2006 IEEE 1528-2013 & Published RF Exposure KDB Procedures Date of Receipt sample .... : 2020-04-08 Date of Test ....................... : 2020-04-09 to 2020-04-15 Date of Issue ..................... : 2020-04-20 Test Result ........................ : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Services (Shenzhen) Co., Ltd. Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen, Guangdong, China Tel :+86-755-83551033 Fax:+86-755-83552400 Compiled by: Approved by: Ford Wang / Project Engineer Philo Zhong / Manager Reference No.: WTS20S03012207W001 V1 Page 2 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................................ 2 3 REVISION HISTORY ........................................................................................................................................... 3 4 GENERAL INFORMATION ................................................................................................................................ 4 4.1 GENERAL DESCRIPTION OF E.U.T. ................................................................................................................... 4 4.2 DETAILS OF E.U.T. .......................................................................................................................................... 4 4.3 TEST FACILITY ................................................................................................................................................. 6 5 EQUIPMENT USED DURING TEST .................................................................................................................. 7 5.1 EQUIPMENT LIST .............................................................................................................................................. 7 5.2 TEST EQUIPMENT CALIBRATION ...................................................................................................................... 7 6 SAR INTRODUCTION.......................................................................................................................................... 8 6.1 INTRODUCTION ................................................................................................................................................ 8 6.2 SAR DEFINITION .............................................................................................................................................. 8 7 SAR MEASUREMENT SETUP ............................................................................................................................ 9 8 EXPOSURE LIMIT ............................................................................................................................................. 18 9 SYSTEM AND LIQUID VALIDATION ............................................................................................................ 19 9.1 SYSTEM VALIDATION ..................................................................................................................................... 19 9.2 LIQUID VALIDATION ....................................................................................................................................... 21 10 TYPE A MEASUREMENT UNCERTAINTY .................................................................................................. 35 11 OUTPUT POWER VERIFICATION ................................................................................................................. 38 12 EXPOSURE CONDITIONS CONSIDERATION ............................................................................................. 65 13 SAR TEST RESULTS .......................................................................................................................................... 67 14 SAR MEASUREMENT REFERENCE ............................................................................................................. 88 MAXIMUM SAR MEASUREMENT PLOTS ................................................................................................................... 89 15 CALIBRATION REPORTS-PROBE AND DIPOLE ..................................................................................... 109 16 RE-CALIBRATION FOR DIPOLE ................................................................................................................. 173 17 SAR SYSTEM PHOTOS ................................................................................................................................... 183 18 SETUP PHOTOS ........................…

Text truncated - open the document above for the full version.

RF Exposure Info

Reference No.: WTS20S03012207W001 V1 Page 112 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 113 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 114 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 115 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 116 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 117 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 118 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 119 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 120 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 121 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 122 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 123 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 124 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 125 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 126 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 127 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 128 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 129 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 130 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 131 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 132 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 133 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 134 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 135 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn

RF Exposure Info

Reference No.: WTS20S03012207W001 V1 Page 136 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 137 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 138 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 139 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 140 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 141 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 142 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207W001 V1 Page 143 of 186 Waltek Services (Shenzhen) Co.,Ltd. http://www.waltek.com.cn Reference No.: WTS20S03012207…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yiting Luo
[email protected]86-755-61803856Fax: +86-755-33979211

Test Firm

WALTEK TESTING GROUP CO., LTD.Joy Zhou
[email protected]0769-22676998

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz10.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 1.0 cm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission and product specific (10 g SAR) exposure conditions are 0.20 W/kg, 0.14 W/kg and 1.21 W/kg, respectively. This device supports 20, 40 and 80 MHz modes.

Other Applications from TECNO MOBILE LIMITED

2ADYY-KO2

Mobile Phone

Sep 16, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ADYY-T1002W

Tablet

Jun 10, 2026

Equipment Class

DTS - Digital Transmission System
2ADYY-KN4N

Mobile Phone

Jun 08, 2026

Equipment Class

PCE - PCS Licensed Transmitter held to ear
2ADYY-CN6

Mobile Phone

Jun 05, 2026

Equipment Class

DTS - Digital Transmission System
2ADYY-T1103

Tablet

May 25, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX