Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 15, 2020
Application Purpose
Original Equipment
Date of Application
Sep 15, 2020
Equipment Note
Mobile Phone
Frequency Range
2412.00000000 - 2462.00000000
Company
TECNO MOBILE LIMITED
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—
โ†—

Cover Letter(s)

โ†—
โ†—
โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—
โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—
โ†—
โ†—
โ†—
โ†—

Test Report

โ†—
โ†—
โ†—
โ†—

Test Setup Photos

โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

E E x x p p l l o o s s i i o o n n d d i i a a g g r r a a m m s s p p e e c c i i f f i i c c a a t t i i o o n n 1 FL(CTP+LCM) 6.52HD+ KE5 Black HX V1.0 2 Astigmatism film 3.5*1.2*0.05 KE5 3 FPC Side key BB4 4 Astigmatism film 3.5*1.2*0.05 KE5 5 Shield Seal Cop foil 20.7*15.5 *0.06 KE5 6 LT sensor Seal rubber KE5 Black 7 F CAM Seal rubber KE5 Black 8 FPC REC KC1 9 FM(ICNF7332AL)04 Aqua Blue19 fingerchip 10 CAM FF 8W GC6153 CSP W6003 XCG V_1.0 11 CAM AF 13M S5K3L6 B B 5P B ST V1.0 12 CAM FF 8M GC8034 A B 4P B TXD V1.0 13 F CAM con fb 10.75*7.75*0.1 KE5 14 DistanceSensorSeal mylar10.7*4.8*0.03 KE5 15 F LED-Flashseal mylar 8*4.8*0.03 KE5 16 PCBA MB H6123 A1 32GB+2GB V1.0 17 REC 1206W H20 broadband H:SPL 50mW Goer 18 R MAIN CAM Con foams 12.61*10.46*0.2 KE5 19 BATT Seal rubber 6.15*4.0*0.65 KE5 20 LCM Con Seal rubber 13.1*3.7 *0.65 KE5 21 R hsg asm KE5 Black PC 22 Bat imp steel KE5 23 R CAM lens KE5 Glass 0.5mm Black 24 mc screw M1.4*L2.5*D2.5 *H0.5 silver glue 25 Bat cover asm KE5 Aqua Blue PC 26 mc screw M1.4*L3.5*D2.5 *H0.5 silver 27 SPK frame asm KE5 Black PC 28 Coaxial cable ECT D 147.9 X653C 29 Bat TECNO BL 49FT 4900mAh FH IN 30 PCBA SUB H6123 1 A V1.0 31 FP graphite film 37.14*28.8 *0.05 KE5 32 FP In mylar 4*4*0.05 KE5 33 FP support foam 13.26*12.78 *0.6 KE5 34 FP con foams 7.5*3.5*1 KE5 35 ZIF mylar 9.5*3.5*0.05 KE5 36 Motor COIN 1027 L22 H JX 37 SPK 1115 SPR H3.0 aluminiumfilmRoHS Goer 38 SUB PCB Con Seal rubber KE5 39 FPC SPK KE5 Know your phone 1. Front camera 2. Volume key 3. Power key SIM/SD card installation 1. Power off mobile. 2. Refer to the following picture for SIM / SD card installation. C C h h a a r r g g i i n n g g t t h h e e p p h h o o n n e e You can charge your device using a charger or by connecting it to the computer using a USB cable (comes with the phone). 1. Please remind the front and back of the plug. 2. Use only TECNO charger and cables. Other chargers or cables may damage the device. This will invalidate your phone warranty. FCC Caution Emergency call If any emergency arises, dial 112/911 (or other emergency call number) for emergency help. Due to the nature of cellular networking, the success of emergency call is not guaranteed. FCC Warning: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types KE5k (FCC ID: 2ADYY-KE5K) has also been tested against this SAR limit. The highest reported SAR values for head, body-worn accessory, and product specific (Hotspot) are 0.762 W/kg, 0.704 W/kg, and 0.735 W/kg respectively. The Max simultaneous SAR is 1.009 W/kg. This device was tested for typical body-worn operations with the back of the handset kept 10mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain a 10mm separation distance between the user's body and the back of the handset. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided. Body-worn Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 1.0 cm must be maintained between the userโ€™s body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.

External Photos

Reference N Waltek Tes http://www EXHIBI EUT View 1 EUT View 2 No.: WTS20X sting Group w.semtest.co T 2 - EUT 1 2 X08052413W (Shenzhen) m.cn T EXTER W-3/4/5 Co., Ltd. RNAL PH HOTOGR APHS Reference N Waltek Tes http://www EUT View 3 EUT View 4 No.: WTS20X sting Group w.semtest.co 3 4 X08052413W (Shenzhen) m.cn W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www EUT View 5 EUT View 6 No.: WTS20X sting Group w.semtest.co 5 6 X08052413W (Shenzhen) m.cn W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www EUT View 7 No.: WTS20X sting Group w.semtest.co 7 X08052413W (Shenzhen) m.cn W-3/4/5 Co., Ltd.

ID Label/Location Info

Reference N Waltek Tes http://www EXHIBI Proposed Specificatio n it is visible durable to r expected lif e Proposed No.: WTS20X sting Group w.semtest.co T 1 - PRO FCC ID La ns: The label or easily acc emain fully l etime. Label Loca X08052413W (Shenzhen) m.cn ODUCT L abel Forma shall be secu cessible to th legible and in ation on EU W-3/4/5 Co., Ltd. LABELIN at urely affixed t he user, and ntact on the UT FCC NG to a permane shall not be device in al l ID Label Lo ently attached readily detac l normal cond cation d part of the d chable. The l ditions of use device, in a lo label shall be e throughout ocation where e sufficiently t the deviceโ€™s e y s

ID Label/Location Info

Reference N Waltek Tes http://www EXHIBI Proposed Specificatio n it is visible durable to r expected lif e Proposed No.: WTS20X sting Group w.semtest.co T 1 - PRO FCC ID La ns: The label or easily acc emain fully l etime. Label Loca X08052413W (Shenzhen) m.cn ODUCT L abel Forma shall be secu cessible to th legible and in ation on EU W-3/4/5 Co., Ltd. LABELIN at urely affixed t he user, and ntact on the UT FCC NG to a permane shall not be device in al l ID Label Lo ently attached readily detac l normal cond cation d part of the d chable. The l ditions of use device, in a lo label shall be e throughout ocation where e sufficiently t the deviceโ€™s e y s

Internal Photos

Reference N Waltek Tes http://www EXHIBI EUT Housi n EUT Housi n No.: WTS20X sting Group w.semtest.co T 3 - EUT ng and Boar ng and Boar X08052413W (Shenzhen) m.cn T INTER rd View 1 rd View 2 W-3/4/5 Co., Ltd. NAL PHO OTOGRA APHS Reference N Waltek Tes http://www Solder Boa r Solder Boar No.: WTS20X sting Group w.semtest.co rd-Compone rd-Compone X08052413W (Shenzhen) m.cn ent View 1 ent View 2 W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www Solder Boa r Solder Boar No.: WTS20X sting Group w.semtest.co rd-Compone rd-Compone X08052413W (Shenzhen) m.cn ent View 3 ent View 4 W-3/4/5 Co., Ltd. Reference N Waltek Tes http://www Antenna V i W No.: WTS20X sting Group w.semtest.co iew Wi-Fi/BT/GP X08052413W (Shenzhen) m.cn PS Ant W-3/4/5 Co., Ltd. LTE GSM /WCD E RX Ant. DMA /LTE A Ant.

RF Exposure Info

Ref : ACR.233.1.17.SATU.A WALTEK TESTING GROUP (SHENZHEN) CO., LTD. 1/F, BUILDING A, HONGWEI INDUSTRIAL PARK, LIUXIAN 2ND ROAD BAO'AN DISTRICT SHENZHEN (518101), CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: SN 45/15 EPGO280 Calibrated at MVG US 2105 Barrett Park Dr. - Kennesaw, GA 30144 Calibration Date: 07/03/2020 Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed in MVG USA using the CALISAR / CALIBAIR test bench, for use with a COMOSAR system only. All calibration results are traceable to national metrology institutions. COMOSAR E-Field Probe Calibration Report COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 2/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Jรฉrรดme LUC Product Manager 7/3/2020 Checked by : Jรฉrรดme LUC Product Manager 7/3/2020 Approved by : Kim RUTKOWSKI Quality Manager 7/3/2020 Customer Name Distribution : Waltek Testing Group (Shenzhen) Co., Ltd. Issue Date Modifications A 7/3/2020 Initial release COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 3/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Linearity ________________________________________________________________ 4 3.2 Sensitivity _______________________________________________________________ 5 3.3 Lower Detection Limit _____________________________________________________ 5 3.4 Isotropy _________________________________________________________________ 5 3.5 Boundary Effect __________________________________________________________ 5 4 Measurement Uncertainty .......................................................................................... 5 5 Calibration Measurement Results .............................................................................. 6 5.1 Sensitivity in air __________________________________________________________ 6 5.2 Linearity ________________________________________________________________ 7 5.3 Sensitivity in liquid ________________________________________________________ 7 5.4 Isotropy _________________________________________________________________ 8 6 List of Equipment .................................................................................................... 10 COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 4/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE2 Serial Number SN 45/15 EPGO280 Product Condition (new / used) New Frequency Range of Probe 0.7 GHz-6GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.193 M๏— Dipole 2: R2=0.188 M๏— Dipole 3: R3=0.198 M๏— A yearly calibration interval is recommended. 2PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVGโ€™s COMOSAR E field Probes are built in accordance to the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards. Figure 1 โ€“ MVG COMOSAR Dosimetric E field Dipole Probe Length 330 mm Length of Individual Dipoles 2 mm Maximum external diameter 8 mm Probe Tip External Diameter 2.5 mm Distance between dipoles / probe extremity 1 mm 3 MEASUREMENT METHOD The IEEE 1528, OET 65 Bulletin C, CENELEC EN50361 and CEI/IEC 62209 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their affect. All calibrations / measurements performed meet the fore mentioned standards. 3.1 LINEARITY The evaluation of the linearity was done in free space using the waveguide, performing a power sweep to cover the SAR range 0.01W/kg to 100W/kg. COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.233.1.17.SATU.A Page: 5/10 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3.2 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards. 3.3 LOWER DETECTION LIMIT The lower detection limit was assessed using the same measurement set up as used for the linearity measurement. The required lower detection limit is 10 mW/kg. 3.4 ISOTROPY The axial isotropy was evaluated by exposing the probe to a reference wave from a standard dipole with the dipole mounted under the flat phantom in the test configuration suggested for system validations and checks. The probe was rotated along its main axis from 0 - 360 degrees in 15 degree steps. The hemispherical isotropy is determined by inserting the probe in a thin plastic box filled with tissue-equivalent liquid, with the plastic โ€ฆ

Text truncated - open the document above for the full version.

RF Exposure Info

Reference No.: WTS20X08052413W Page 101 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 5.221202 SAR 1g (W/Kg) 9.582560 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 11.2425 9.4123 8.0345 6.9125 6.3092 3.9460 3D screen shot Hot spot position Reference No.: WTS20X08052413W Page 102 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 10 For Body Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2020/07/03 A. Experimental conditions Area Scan dx=8mm dy=8mm Phantom Validation plane Device Position Dipole Band CW1900 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 1900.000000 Relative Permittivity (real part) 52.420415 Conductivity (S/m) 1.501966 Power Variation (%) 0.541872 Ambient Temperature 21.1 Liquid Temperature 21.3 SURFACE SAR VOLUME SAR Reference No.: WTS20X08052413W Page 103 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 5.134651 SAR 1g (W/Kg) 9.781550 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 10.2031 6.43001 4.9011 4.5325 3.1201 2.5024 3D screen shot Hot spot position Reference No.: WTS20X08052413W Page 104 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 11 For Body Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2020/07/03 A. Experimental conditions Area Scan dx=8mm dy=8mm Phantom Validation plane Device Position Dipole Band CW2450 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 2450.000000 Relative Permittivity (real part) 52.010212 Conductivity (S/m) 1.910255 Power Variation (%) 1.369745 Ambient Temperature 21.1 Liquid Temperature 21.2 SURFACE SAR VOLUME SAR Reference No.: WTS20X08052413W Page 105 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 7.119522 SAR 1g (W/Kg) 12.592360 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 13.1911 11.7951 9.2945 8.5400 6.3712 4.6225 3D screen shot Hot spot position Reference No.: WTS20X08052413W Page 106 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 12 For Body Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2020/07/03 A. Experimental conditions Area Scan dx=8mm dy=8mm Phantom Validation plane Device Position Dipole Band CW2600 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 2600.000000 Relative Permittivity (real part) 52.241202 Conductivity (S/m) 2.120943 Power Variation (%) 1.038832 Ambient Temperature 21.1 Liquid Temperature 21.2 SURFACE SAR VOLUME SAR Reference No.: WTS20X08052413W Page 107 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 6.083781 SAR 1g (W/Kg) 13.430481 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 13.6473 11.8441 9.3627 8.5782 6.4357 4.6342 3D screen shot Hot spot position Reference No.: WTS20X08052413W Page 108 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Annex B. Plots of SAR Measurement TYPE BAND PARAMETERS Phone GSM850 Measurement 1: Right Head with Cheek device position on Middle Channel in GSM mode Phone GSM1900 Measurement 5: Right Head with Cheek device position on Low Channel in GSM mode Phone GPRS850_2TX Measurement 9: Right Head with Cheek device position on High Channel in GPRS mode Phone GPRS1900_2TX Measurement 13: Right Head with Cheek device position on Low Channel in GPRS mode Phone WCDMA1900_RMC Measurement 17: Right Head with Cheek device position on High Channel in WCDMA mode Phone WCDMA1700_RMC Measurement 21: Right Head with Cheek device position on Low Channel in WCDMA mode Phone WCDMA850_RMC Measurement 25: Right Head with Cheek device position on Middle Channel in WCDMA mode Phone LTE Band 2_RMC Measurement 29: Right Head with Cheek device position on Low Channel in LTE mode Phone LTE Band 4_RMC Measurement 37: Right Head with Cheek device position on High Channel in LTE mode Phone LTE Band 5_RMC Measurement 45: Right Head with Cheek device position on Middle Channel in LTE mode Phone LTE Band 7_RMC Measurement 53: Right Head with Cheek device position on Middle Channel in LTE mode Phone LTE Band 38_RMC Measurement 61: Right Head with Cheek device position on Low Channel in LTE mode Phone LTE Band 41_RMC Measurement 69: Right Head with Cheek device position on Low Channel in LTE mode Phone WiFi_802.11b Measurement 79: Left Head with Cheek device position on Middle Channel in 802.11b mode Phone GSM850 Measurement 89: Flat Plane with Back device position on Middle Channel in GSM mode Phone GSM1900 Measurement 91: Flat Plane with Back device position on Low Channel in GSM mode Phone GPRS850_2TX Measurement 120: Flat Plane with Back device position on High Channel in GPRS mode Phone GPRS1900_2TX Measurement 133: Flat Plane with Back device position on Low Channel in GPRS mode Phone WCDMA1900_RMC Measurement 140: Flat Plane with Back side device Reference No.: WTS20X08052413W Page 109 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn position on High Channel in WCDMA mode Phone WCDMA1700_RMC Measurement 144: Flat Plane with Top side device position on Low Channel in WCDMA mode Phone WCDMA850_RMC Measurement 145: Flat Plane with Back side device position on Middle Channel in WCDMA mode Phone LTE Band 2_RMC Measurement 152: Flat Plane with Top deviโ€ฆ

Text truncated - open the document above for the full version.

RF Exposure Info

Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Page 1 of 168 TEST REPORT Reference No. .................... : WTS20X08052413W FCC ID ................................ : 2ADYY-KE5K Applicant ........................... : TECNO MOBILE LIMITED Address ............................. : ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL Product Name ................... : Mobile Phone Test Model. ........................ : KE5k Standards .......................... : FCC Part 2.1093 ANSI / IEEE C95.1 : 2005+A1:2010 ANSI / IEEE C95.3 : 2002(R2008) IEEE 1528 :2013 Date of Receipt sample .... : Aug.10, 2020 Date of Test........................ : Aug.10, 2020 to Aug.18, 2020 Date of Issue ..................... : Aug.19, 2020 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Tested by: Reviewed By: Approved & Authorized By: Jack Sun / Project Engineer Lion Cai / RF Manager Silin Chen / Manager Reference No.: WTS20X08052413W Page 2 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn TABLE OF CONTENTS 1. General Information ................................................................................................................................................... 3 1.1 Product Description for Equipment Under Test (EUT) ......................................................................................... 3 1.2 Test Standards .................................................................................................................................................... 6 1.3 Test Methodology ................................................................................................................................................ 6 1.4 Test Facility ......................................................................................................................................................... 6 2. Summary of Test Results .......................................................................................................................................... 7 3. Specific Absorption Rate (SAR) ................................................................................................................................ 8 3.1 Introduction .......................................................................................................................................................... 8 3.2 SAR Definition ..................................................................................................................................................... 8 4. SAR Measurement System ........................................................................................................................................ 9 4.1 The Measurement System .................................................................................................................................. 9 4.2 Probe ................................................................................................................................................................... 9 4.3 Probe Calibration Process ................................................................................................................................. 11 4.4 Phantom ............................................................................................................................................................ 12 4.5 Device Holder .................................................................................................................................................... 12 4.6 Test Equipment List ........................................................................................................................................... 13 5. Tissue Simulating Liquids ....................................................................................................................................... 14 5.1 Composition of Tissue Simulating Liquid ........................................................................................................... 14 5.2 Tissue Dielectric Parameters for Head and Body Phantoms ............................................................................. 15 5.3 Tissue Calibration Result ................................................................................................................................... 16 6. SAR Measurement Evaluation ................................................................................................................................ 17 6.1 Purpose of System Performance Check ............................................................................................................ 17 6.2 System Setup .................................................................................................................................................... 17 6.3 Validation Results .............................................................................................................................................. 18 7. EUT Testing Position ............................................................................................................................................... 20 7.1 Define Two Imaginary Lines on The Handset .................................................................................................... 20 7.2 Cheek Position ...............................................................................................โ€ฆ

Text truncated - open the document above for the full version.

RF Exposure Info

Reference No.: WTS20X08052413W Page 101 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 5.221202 SAR 1g (W/Kg) 9.582560 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 11.2425 9.4123 8.0345 6.9125 6.3092 3.9460 3D screen shot Hot spot position Reference No.: WTS20X08052413W Page 102 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 10 For Body Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2020/07/03 A. Experimental conditions Area Scan dx=8mm dy=8mm Phantom Validation plane Device Position Dipole Band CW1900 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 1900.000000 Relative Permittivity (real part) 52.420415 Conductivity (S/m) 1.501966 Power Variation (%) 0.541872 Ambient Temperature 21.1 Liquid Temperature 21.3 SURFACE SAR VOLUME SAR Reference No.: WTS20X08052413W Page 103 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 5.134651 SAR 1g (W/Kg) 9.781550 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 10.2031 6.43001 4.9011 4.5325 3.1201 2.5024 3D screen shot Hot spot position Reference No.: WTS20X08052413W Page 104 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 11 For Body Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2020/07/03 A. Experimental conditions Area Scan dx=8mm dy=8mm Phantom Validation plane Device Position Dipole Band CW2450 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 2450.000000 Relative Permittivity (real part) 52.010212 Conductivity (S/m) 1.910255 Power Variation (%) 1.369745 Ambient Temperature 21.1 Liquid Temperature 21.2 SURFACE SAR VOLUME SAR Reference No.: WTS20X08052413W Page 105 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 7.119522 SAR 1g (W/Kg) 12.592360 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 13.1911 11.7951 9.2945 8.5400 6.3712 4.6225 3D screen shot Hot spot position Reference No.: WTS20X08052413W Page 106 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn MEASUREMENT 12 For Body Liquid Type: Validation measurement (Fast, 75.00 %) Measurement duration: 12 minutes 21 seconds E-field Probe: SSE2 - SN 45/15 EPGO280; ConvF: Refer to the Calibration Certificate; Calibrated: 2020/07/03 A. Experimental conditions Area Scan dx=8mm dy=8mm Phantom Validation plane Device Position Dipole Band CW2600 Signal Duty Cycle 1:1 B. SAR Measurement Results Frequency (MHz) 2600.000000 Relative Permittivity (real part) 52.241202 Conductivity (S/m) 2.120943 Power Variation (%) 1.038832 Ambient Temperature 21.1 Liquid Temperature 21.2 SURFACE SAR VOLUME SAR Reference No.: WTS20X08052413W Page 107 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Maximum location: X=0.00, Y=0.00 SAR 10g (W/Kg) 6.083781 SAR 1g (W/Kg) 13.430481 Z Axis Scan Z (mm) 0.00 4.00 9.00 14.00 19.00 24.00 29.00 SAR (W/Kg) 0.0000 13.6473 11.8441 9.3627 8.5782 6.4357 4.6342 3D screen shot Hot spot position Reference No.: WTS20X08052413W Page 108 of 168 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Annex B. Plots of SAR Measurement TYPE BAND PARAMETERS Phone GSM850 Measurement 1: Right Head with Cheek device position on Middle Channel in GSM mode Phone GSM1900 Measurement 5: Right Head with Cheek device position on Low Channel in GSM mode Phone GPRS850_2TX Measurement 9: Right Head with Cheek device position on High Channel in GPRS mode Phone GPRS1900_2TX Measurement 13: Right Head with Cheek device position on Low Channel in GPRS mode Phone WCDMA1900_RMC Measurement 17: Right Head with Cheek device position on High Channel in WCDMA mode Phone WCDโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yiting Luo
[email protected]86-755-61803856Fax: +86-755-33979211

Test Firm

Waltek Testing Group (Shenzhen) Co., Ltd.Jandy So
[email protected]86 755 33663308Fax: 86-755-33663309

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz40.50 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 1.0 cm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 0.19 W/kg, 0.31 W/kg, 0.31 W/kg and 1.01 W/kg, respectively. This device supports 20 and 40 MHz bandwidth modes.

Other Applications from TECNO MOBILE LIMITED

2ADYY-KO2

Mobile Phone

Sep 16, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ADYY-T1002W

Tablet

Jun 10, 2026

Equipment Class

DTS - Digital Transmission System
2ADYY-KN4N

Mobile Phone

Jun 08, 2026

Equipment Class

PCE - PCS Licensed Transmitter held to ear
2ADYY-CN6

Mobile Phone

Jun 05, 2026

Equipment Class

DTS - Digital Transmission System
2ADYY-T1103

Tablet

May 25, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX