Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Sep 08, 2020
Application Purpose
Original Equipment
Date of Application
Sep 08, 2020
Equipment Note
Mobile Phone
Frequency Range
5725.00000000 - 5825.00000000
Company
TECNO MOBILE LIMITED
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

E E x x p p l l o o s s i i o o n n d d i i a a g g r r a a m m s s p p e e c c i i f f i i c c a a t t i i o o n n 1 R CAM lens LD7 2 Bat cover asm LD7 3 ScrewM1.4-L3.5 4 UP frame asm LD7 5 Finger Print Module LD7 6 FP support foam 7 FP Con foam 8 TOP salt fog mylar 9 FPC Power Key LD7 10 SPK ASM 11 BB Shield Sealcop foil 12 PCBA MB 13 LCM FPC con rubber 14 PA Shield SealCop foil 15 RF Shield SealCop foil 16 Microslens RCAM Rubber LD7 17 Bokeh CAM Rubber LD7 18 CAM FF 8W 19 MicroLens CAM 20 Rear Cam Main 21 CopFoil R-Cam mian 22 Bokeh CAM 23 F CAM frame asm LD7 24 F CAM Cop foil LD7 25 Front CAM 26 Distance Sensor rubber LD7 27 F hsg asm LD7 28 REC Deco asm 29 FL(CTP+LCM)6.78HD+h 30 FPC Googlekey LD7 31 RF Cable LD7 32 SIM holder LD7 33 Motor 34 PCBA sub 35 SubPCBA Seal Rubber 36 Battery LD7 37 DOWN frame asm LD7 38 MIC rubber LD7 39 Screw M1.4-L2.5 Know your phone 1. Front camera 2. Volume key 3. Power key SIM/SD card installation 1. Power off mobile. 2. Refer to the following picture for SIM / SD card installation. C C h h a a r r g g i i n n g g t t h h e e p p h h o o n n e e You can charge your device using a charger or by connecting it to the computer using a USB cable (comes with the phone). 1. Please remind the front and back of the plug. 2. Use only TECNO charger and cables. Other chargers or cables may damage the device. This will invalidate your phone warranty. F F C C C C S S t t a a t t e e m m e e n n t t 1.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2.Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.` Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. SAR Information Statement Your wireless phone is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radiofrequency (RF) energy set by the Federal Communications Commission of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg. * Tests for SAR are conducted with the phone transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. The highest SAR value for this model phone when tested for use at the ear is 1.276W/Kg and when worn on the body, as described in this user guide, is 0.743W/Kg(Body-worn measurements differ among phone models, depending upon available accessories and FCC requirements). The maximum scaled SAR in hotspot mode is 0.758W/Kg. While there may be differences between the SAR levels of various phones and at various positions, they all meet the government requirement for safe exposure. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RFexposure guidelines. SAR information on this model phone is on file with the FCC and can be found under the Display Grant section of http://www.fcc.gov/ oet/fccid after searching on FCC ID: 2ADYY-LD7 Additional information on Specific Absorption Rates (SAR) can be found on the Cellular Telecommunications Industry Asso-ciation (CTIA) web-site at http://www.wow-com.com. * In the United States and Canada, the SAR limit for mobile phones used by the public is 1.6 watts/kg (W/kg) averaged over one gram of tissue. The standard incorporates a sub-stantial margin of safety to give additional protection for the public and to account for any variations in measurements. Body-worn Operation This device was tested for typical body-worn operations. To comply with R…

Text truncated - open the document above for the full version.

Cover Letter(s)

FCC Software Configuration Control Declaration Rev1.1 TECNO MOBILE LIMITED FCC Software Configuration Control Declaration Date: September 9, 2020 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: OET Dept. Product/ Model Number: Mobile Phone/ LD7 Regarding FCC Country Code Selection guidelines identified in KDB 594280. “All applications for equipment authorization for transmitters that can have radio parameters, or other technical parameters, reported to the Commission set by software must have an attestation indicating that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified.” We declare that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified. Name: Yiting Luo Date: 2020-9-07 Title:Manager Signature of applicant

Cover Letter(s)

TECNO MOBILE LIMITED Company: TECNO MOBILE LIMITED Address: ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL Hong Kong Product Name: Mobile Phone Model Number(s): LD7 Product Description: Mobile Phone We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2020-9-07 Name: Yiting Luo Title: Manager Company: TECNO MOBILE LIMITED

Cover Letter(s)

TECNO MOBILE LIMITED Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2020-09-07 Subject; Request for Confidentiality FCC ID: 2ADYY-LD7 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure BOM FCC SW SECURITY DESCRIPTION In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual EUT photos and SAR test setup photos For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Yiting Luo Title: Manager

External Photos

Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 49 of 60 8 EUT Constructional Details Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 50 of 60 Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 51 of 60 Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 52 of 60 Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 53 of 60

ID Label/Location Info

label location label location

Internal Photos

Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 54 of 60 Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 55 of 60 Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 56 of 60 Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 57 of 60 Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 58 of 60 Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 59 of 60 Report No: CCISE200803501 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 60 of 60 ------End of report------

RF Exposure Info

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCISE200803601 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC SAR REPORT Applicant: TECNO MOBILE LIMITED Address of Applicant: ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL Equipment Under Test (EUT) Product Name: Mobile Phone Model No.: LD7 Trade mark TECNO FCC ID: 2ADYY-LD7 Applicable standards: FCC 47 CFR Part 2.1093 Date of Test: 18 Aug., 2020 ~ 29 Aug., 2020 Test Result: Maximum Reported 1-g SAR (W/kg) Head: 1.276 Body: 0.743 Hotspot: 0.758 Report No: CCISE200803601 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008036 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 2 of 228 2 Version Version No. Date Description 00 04 Sep., 2020 Original Tested by: Date: 04 Sep., 2020 Report Clerk Reviewed by: Date: 04 Sep., 2020 Project Engineer Report No: CCISE200803601 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008036 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 3 of 228 3 Contents 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 SAR RESULTS SUMMARY ................................................................................................................................. 5 5 GENERAL INFORMATION .................................................................................................................................. 7 5.1 CLIENT INFORMATION ..................................................................................................................................................................... 7 5.2 GENERAL DESCRIPTION OF EUT ................................................................................................................................................... 7 5.3 MAXIMUM RF OUTPUT POWER ...................................................................................................................................................... 8 5.4 ENVIRONMENT OF TEST SITE ......................................................................................................................................................... 9 5.5 TEST SAMPLE PLAN ....................................................................................................................................................................... 9 5.6 TEST LOCATION ............................................................................................................................................................................. 9 6 INTRODUCTION ................................................................................................................................................. 10 6.1 INTRODUCTION ............................................................................................................................................................................. 10 6.2 SAR DEFINITION .......................................................................................................................................................................... 10 7 RF EXPOSURE LIMITS ..................................................................................................................................... 11 7.1 UNCONTROLLED ENVIRONMENT ................................................................................................................................................... 11 7.2 CONTROLLED ENVIRONMENT ....................................................................................................................................................... 11 7.3 RF EXPOSURE LIMITS .................................................................................................................................................................. 11 8 SAR MEASUREMENT SYSTEM ....................................................................................................................... 12 8.1 E-FIELD PROBE............................................................................................................................................................................ 13 8.2 DATA ACQUISITION ELECTRONICS (DAE) .............................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No: CCISE200803601 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008036 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 101 of 228 Test Laboratory: CCIS Date/Time: 08.28.2020 16:01:29 DUT: Mobile Phone; Type: LD7; Serial: 2# Communication System: UID 0, UMTS-FDD(WCDMA) (0); Frequency: 1712.4 MHz; Duty Cycle: 1:1 Medium parameters used (interpolated): f = 1712.4 MHz; σ = 1.373 S/m; ε r = 40.327; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 – SN3924; ConvF(8.4, 8.4, 8.4); Calibrated: 08.30.2019;  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1373; Calibrated: 07.27.2020  Phantom: SAM 5.0; Type: QD000P40CD; Serial: TP:1765  Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) WCDMA 1700 Left Tilted/Low Channel/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 16.40 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 1.57 W/kg SAR(1 g) = 0.776 W/kg; SAR(10 g) = 0.376 W/kg Maximum value of SAR (measured) = 1.02 W/kg WCDMA 1700 Left Tilted/Low Channel/Area Scan (51x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.638 W/kg 0 dB = 0.638 W/kg = -1.95 dBW/kg Report No: CCISE200803601 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008036 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 102 of 228 Test Laboratory: CCIS Date/Time: 08.28.2020 12:52:53 DUT: Mobile Phone; Type: LD7; Serial: 2# Communication System: UID 0, UMTS-FDD(WCDMA) (0); Frequency: 1852.4 MHz; Duty Cycle: 1:1 Medium parameters used (interpolated): f = 1852.4 MHz; σ = 1.413 S/m; ε r = 39.752; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 – SN3924; ConvF(8.17, 8.17, 8.17); Calibrated: 08.30.2019;  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1373; Calibrated: 07.27.2020  Phantom: SAM 5.0; Type: QD000P40CD; Serial: TP:1765  Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) WCDMA 1900 Left Tilted/Low Channel/Area Scan (51x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.951 W/kg WCDMA 1900 Left Tilted/Low Channel/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 22.08 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 2.40 W/kg SAR(1 g) = 1.18 W/kg; SAR(10 g) = 0.569 W/kg Maximum value of SAR (measured) = 1.59 W/kg 0 dB = 1.59 W/kg = 2.01 dBW/kg Report No: CCISE200803601 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008036 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 103 of 228 Test Laboratory: CCIS Date/Time: 08.28.2020 22:17:52 DUT: Mobile Phone; Type: LD7; Serial: 2# Communication System: UID 0, LTE-Fdd(USA) 1RB QPSK (0); Frequency: 1860 MHz; Duty Cycle: 1:1 Medium parameters used: f = 1860 MHz; σ = 1.417 S/m; ε r = 39.713; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 – SN3924; ConvF(8.17, 8.17, 8.17); Calibrated: 08.30.2019;  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1373; Calibrated: 07.27.2020  Phantom: SAM 5.0; Type: QD000P40CD; Serial: TP:1765  Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) LTE Band 2 1RB(20MHz) Left Tilted/Low Channel/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 18.34 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 1.90 W/kg SAR(1 g) = 0.938 W/kg; SAR(10 g) = 0.455 W/kg Maximum value of SAR (measured) = 1.21 W/kg LTE Band 2 1RB(20MHz) Left Tilted/Low Channel/Area Scan (51x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.886 W/kg 0 dB = 0.886 W/kg = -0.53 dBW/kg Report No: CCISE200803601 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008036 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 104 of 228 Test Laboratory: CCIS Date/Time: 08.29.2020 06:08:51 DUT: Mobile Phone; Type: LD7; Serial: 2# Communication System: UID 0, LTE-Fdd(USA) 1RB QPSK (0); Frequency: 1745 MHz; Duty Cycle: 1:1 Medium parameters used: f = 1745 MHz; σ = 1.385 S/m; ε r = 40.201; ρ = 1000 kg/m 3 Phantom section: Left Section DASY5 Configuration:  Probe: EX3DV4 – SN3924; ConvF(8.4, 8.4, 8.4); Calibrated: 08.30.2019;  Sensor-Surface: 1.4mm (Mechanical Surface Detection)  Electronics: DAE4 Sn1373; Calibrated: 07.27.2020  Phantom: SAM 5.0; Type: QD000P40CD; Serial: TP:1765  Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) LTE Band 4 1RB(20MHz) Left Tilted/High Channel/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 17.91 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 2.05 W/kg SAR(1 g) = 1.01 W/kg; SAR(10 g) = 0.487 W/kg Maximum value of SAR (measured) = 1.31 W/kg LTE Band 4 1RB(20MHz) Left Tilted/High Channel/Area Scan (51x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 1.05 W/kg 0 dB = 1.05 W/kg = 0.21 dBW/kg Report No: CCISE200803601 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008036 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 105 of 228 Test Laboratory: CCIS Date/Time: 08.27…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCISE200803506V01 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC REPORT (UNII) Applicant: TECNO MOBILE LIMITED Address of Applicant: ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL Equipment Under Test (EUT) Product Name: Mobile Phone Model No.: LD7 Trade mark: TECNO FCC ID: 2ADYY-LD7 Applicable standards: FCC CFR Title 47 Part 15 Subpart E Section 15.407 Date of sample receipt: 13 Aug., 2020 Date of Test: 14 Aug., to 26 Aug., 2020 Date of report issued: 10 Sep., 2020 Test Result: PASS* * In the configuration tested, the EUT complied with the standards specified above. Report No: CCISE200803506V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 2 of 78 2 Version Version No. Date Description 00 03 Sep., 2020 Original 01 10 Sep., 2020 Delete the antenna photo in section 6.1 Tested by: Date: 10 Sep., 2020 Test Engineer Reviewed by: Date: 10 Sep., 2020 Project Engineer Report No: CCISE200803506V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2008035 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 3 of 78 3 Contents Page 1 COVER PAGE ................................................................................................................................................... 1 2 VERSION ........................................................................................................................................................... 2 3 CONTENTS ....................................................................................................................................................... 3 4 TEST SUMMARY .............................................................................................................................................. 4 5 GENERAL INFORMATION .............................................................................................................................. 5 5.1 CLIENT INFORMATION .................................................................................................................................................... 5 5.2 GENERAL DESCRIPTION OF E.U.T. ............................................................................................................................... 5 5.3 TEST ENVIRONMENT AND MODE, AND TEST SAMPLES PLANS ....................................................................................... 7 5.4 DESCRIPTION OF SUPPORT UNITS ................................................................................................................................ 7 5.5 MEASUREMENT UNCERTAINTY...................................................................................................................................... 7 5.6 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD .............................................................................. 7 5.7 RELATED SUBMITTAL(S) / GRANT (S) ........................................................................................................................... 7 5.8 LABORATORY FACILITY ................................................................................................................................................. 8 5.9 LABORATORY LOCATION ............................................................................................................................................... 8 5.10 TEST INSTRUMENTS LIST ............................................................................................................................................ 9 6 TEST RESULTS AND MEASUREMENT DATA ........................................................................................... 10 6.1 ANTENNA REQUIREMENT ..................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yiting Luo
[email protected]86-755-61803856Fax: +86-755-33979211

Technical Contact

TECNO MOBILE LIMITED
[email protected]

Hong Kong

Test Firm

JianYan Testing Group Shenzhen Co., Ltd.Bruce Zhang
[email protected]+86 (0) 755 23118282

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.72 GHz - 5.83 GHz7.71 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions is 0.18W/kg, 0.16W/kg, 0.16W/kg and 1.54W/kg respectively.

Other Applications from TECNO MOBILE LIMITED

2ADYY-KO2

Mobile Phone

Sep 16, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ADYY-T1002W

Tablet

Jun 10, 2026

Equipment Class

DTS - Digital Transmission System