Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Tel.: +86-755-61803856 Fax: +86-755-33979211 E-mail: [email protected] CFR 47 Β§2.911(d)(5)(i) Attestation Letter Attestation Letter Date: 2024-07-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 Β§2.911(d)(5)(i) Filing FCC ID: 2ADYY-T1001 TECNO MOBILE LIMITED certifies that the equipment for which authorization is sought is not βcoveredβ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely Yours, Signature Yiting Luo Manager
TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Tel.: +86-755-61803856 Fax: +86-755-33979211 E-mail: [email protected] CFR 47 Β§2.911 (d)(5)(ii) Attestation Letter Attestation Letter Date: 2024-07-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 Β§2.911(d)(5)(ii) Filing FCC ID: 2ADYY-T1001 TECNO MOBILE LIMITED certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing βcoveredβ equipment. Sincerely Yours, Signature Yiting Luo Manager
U.S. AGENT LETTER OF ATTESTATION Date: 2024-07-15 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 Β§2.911(d)(7) Filing FCC ID: 2ADYY-T1001 TECNO MOBILE LIMITED certifies that, as of the date of the filing of the application, Iconsigh Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. TECNO MOBILE LIMITED accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Inc. Address: 2310 Homestead Road, Suite C1, Los Altos, CA, 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG FRN: 0024206328 Tel: +86-755-61803856 Email: [email protected] Signed by (printed name): Yiting Luo Signature:
TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Tel.: +86-755-61803856 Fax: +86-755-33979211 E-mail: [email protected] QA-FR-170-B FCC Authorization Date: 2024-07-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, TECNO MOBILE LIMITED hereby authorizes Bay Area Compliance Laboratories Corp. (Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature Yiting Luo Manager
TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Tel.: +86-755-61803856 Fax: +86-755-33979211 E-mail: [email protected] FCC Confidential Authorization Date: 2024-07-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2ADYY-T1001 In accordance with Sections 0.457 and 0.459 of the Commissionβs Rules, TECNO MOBILE LIMITED hereby requests long-term confidential treatment of information accompanying this application as outlined below: β’ Block Diagram β’ Schematics β’ Operation Description β’ Software Security Description β’ Part list/Tune up Procedure (for licensed device) As well as short-term confidential treatment of information accompanying this application for a period of 180 days after grant is issued as outlined below: β’ Internal Photos β’ Userβs Manual β’ External Photos β’ Test Set-up Photos The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature Yiting Luo Manager
TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Tel.: +86-755-61803856 Fax: +86-755-33979211 E-mail: [email protected] Product Similarity Declaration Date: 2024-07-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization Dear Sir/Madam, We, TECNO MOBILE LIMITED hereby declare that we have a product named as Tablet (model: T1001, FCC ID: 2ADYY-T1001) was tested by Bay Area Compliance Laboratories Corp. (Dongguan), Meanwhile, For our marketing purpose, the model will have some differences (different configurations). The specific differences are as follows: model difference description T1001 color gold and grey screen from different manufacturers 1.Shenzhen HJR Electronics Technology Co.,LTD 2.SAT INTERNATIONAL CO.,LTD camera from different manufacturers 1.XINFENG SEGA SCIENCE AND TECHNOLOGY CO., LTD 2.SHENZHEN CHENGXIANG TECHNOLOGY CO.,LTD battery from different manufacturers 1.HuiZhou Ganfeng LiEnergy Battery Tech Co., LTD 2.Hunan Gaoyuan Battery Co.,Ltd. PCB board (Main board) Different colors (Green or black) TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Tel.: +86-755-61803856 Fax: +86-755-33979211 E-mail: [email protected] internal memory sensor from different manufacturers EMMC 1.Shenzhen Longsys Electronics Co., Ltd. 2.Phison Electronics Corp. DDR 1.Shenzhen Longsys Electronics Co., Ltd. 2.Samsung Electronics Co., Ltd. All the configurations are identical in schematics. No other changes are made on the configurations. We confirm that all information above is true, and weβll be responsible for all the consequences. Please contact me if you have any question. Sincerely Yours, Signature Yiting Luo Manager
20mmΒ±2mm 90.4mmΒ±2mm90.4mmΒ±2mm 60 mm 40 mm Model: T1001 SN: XXXXXXXXXXXXXXX 128+4 A FCC ID: 2ADYY-T1001 MADE IN CHINA IMEI: XXXXXXXXXXXXXXX Model: T1001 SN: XXXXXXXXXXXXXXX 128+4 A FCC ID: 2ADYY-T1001 MADE IN CHINA IMEI: XXXXXXXXXXXXXXX Label Label location
Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402U81179E-RF-00D Report Template Version: FCC-WiFi5-Client-V1.2 Page 89 of 89 EXHIBIT C - RF EXPOSURE EVALUATION SAR EVALUATION Applicable Standard According toΒ§1.1310, systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commissionβs guideline. According to KDB447498 D01 General RF Exposure Guidance v06: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances β€ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] κ [βf(GHz)] β€ 3.0 for 1-g SAR and β€ 7.5 for 10-g extremity SAR, where β’ f(GHz) is the RF channel transmit frequency in GHz β’ Power and distance are rounded to the nearest mW and mm before calculation β’ The result is rounded to one decimal place for comparison β’ 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is β€ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. Measurement Result The max conducted power including tune-up tolerance is 7.5 dBm (5.62mW). [(max. power of channel, mW)/(min. test separation distance, mm)][βf(GHz)] =5.62/5*(β5825) = 2.72< 3.0 Note: the max conducted power including tune-up tolerance was declared by manufacturer. Result: Compliant. The stand-alone SAR evaluation is not necessary. ***** END OF REPORT *****
ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] ApprovalSheet CustomerYiDaoData2024/07/08 Product3IN1antennaModelsT8630 P/N T718CustomerP/N 01.WF7.T86300XYC02 SpecificationsBlackFPC;Goldfingergilding VenderApprovedByCustomerApprovedBy CheckedBy:CheckedBy: AuditBy:AuditBy: ApprovalBy:ApprovalBy: DocumentRevisionResume Version ReviseTheContentRevusedApprovalDateNote ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] Content NO.ProectPageNO. 1Specification3 2AntennaPlacement4 3TestData5~~9 4AntennaAssembly10 ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] Specification 1.1ElectricalProperties CharacteristicsSpecifications WorkingBand GPS 2.4GWiFi/BT 5GWiFi AntennaFromPIFA Impedance50Ξ© PolarizationLinear 1.2PhysicalProperties CharacteristicsSpecifications OperatingTemp -10 Β°C ~+60 Β°C StorageTemp -10Β°C~+70Β°C Humidity10~95%RH ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] AntennaPlacement ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] TestData S11Parameter-VSWR EfficiencyTable-GPS EfficiencyTable-2.4G ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] EfficiencyTable-5G ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] RadiationPattern-GPS RadiationPattern-2.4G RadiationPattern-5G ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] WIFI/BTMeasured GPSMeasured ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] WiFiActiveTestData ShenZhenXingYuanChuangTechnologyCo.,Ltd Address:1506,TangweiBusinessBuilding,FuhaiStreet,FuyongTown,BaoanDistrict,Shenzhen TelοΌ0755-82103639QQοΌ487580356EmailοΌ[email protected] AntennaAssembly
TEST REPORT Applicant: TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Product Name: Tablet FCC ID: 2ADYY-T1001 Standard(s): 47 CFR Part 15, Subpart E(15.407) ANSI C63.10-2013 KDB 789033 D02 General U-NII Test Procedures New Rules v02r01 Report Number: 2402U81179E-RF-00D Report Date: 2024/8/13 The above device has been tested and found compliant with the requirement of the relative standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Gavin Xu Approved By: Ivan Cao Title: RF Engineer Title: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked β² is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with β .This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402U81179E-RF-00D Report Template Version: FCC-WiFi5-Client-V1.2 Page 2 of 89 CONTENTS DOCUMENT REVISION HISTORY κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 4 1. GENERAL INFORMATION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 5 1.2 ACCESSORY INFORMATION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 6 1.3 ANTENNA INFORMATION DETAILβ² κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 6 1.4 EQUIPMENT MODIFICATIONS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 6 2. SUMMARY OF TEST RESULTS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 7 3. DESCRIPTION OF TEST CONFIGURATION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 3.1 OPERATION FREQUENCY DETAIL κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 8 3.2 EUT OPERATION CONDITION κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 9 3.3 SUPPORT EQUIPMENT LIST AND DETAILS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 3.4 SUPPORT CABLE LIST AND DETAILS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 10 3.5 BLOCK DIAGRAM OF TEST SETUP κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 11 3.6 TEST FACILITY κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 12 3.7 MEASUREMENT UNCERTAINTY κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 12 4. REQUIREMENTS AND TEST PROCEDURES κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 13 4.1 AC LINE CONDUCTED EMISSIONS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 13 4.1.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 13 4.1.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 14 4.1.3 EMI Test Receiver Setup κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 14 4.1.4 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 4.1.5 Corrected Amplitude & Margin Calculation κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 4.1.6 Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 15 4.2 RADIATION SPURIOUS EMISSIONS κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.2.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 16 4.2.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 17 4.2.3 EMI Test Receiver & Spectrum Analyzer Setup κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 18 4.2.4 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 19 4.2.5 Corrected Result & Margin Calculation κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 19 4.2.6 Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 19 4.3 EMISSION BANDWIDTH κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 20 4.3.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 20 4.3.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 20 4.3.3 Test Procedure κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 20 4.3.4 Test Result κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 21 4.4 MAXIMUM CONDUCTED OUTPUT POWER κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 22 4.4.1 Applicable Standard κκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκ 22 4.4.2 EUT Setupκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκκβ¦
Text truncated - open the document above for the full version.
TEST REPORT Applicant: TECNO MOBILE LIMITED Address: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Product Name: Tablet FCC ID: 2ADYY-T1001 Standard(s): 47 CFR Part 15, Subpart E(15.407) FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 Report Number: 2402U81179E-RF-00F Report Date: 2024/7/25 The above device has been tested and found compliant with the requirement of the relative standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Gavin Xu Approved By: Ivan Cao Title: RF Engineer Title: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked β² is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with β .This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402U81179E-RF-00F Report Template Version: DFS-V1.0 Page 2 of 19 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 3 1. GENERAL INFORMATION .................................................................................................... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 4 1.2 ACCESSORY INFORMATION: ............................................................................................................... 4 1.3 ANTENNA INFORMATION DETAILβ²: ................................................................................................. 5 1.4 EQUIPMENT MODIFICATIONS ............................................................................................................. 5 2. DESCRIPTION OF TEST CONFIGURATION ..................................................................... 6 2.1 EUT OPERATION CONDITION ............................................................................................................. 6 2.2 SUPPORT EQUIPMENT LIST AND DETAILS ......................................................................................... 6 2.3 SUPPORT CABLE LIST AND DETAILS .................................................................................................. 6 2.4 BLOCK DIAGRAM OF TEST SETUP ...................................................................................................... 6 2.5 TEST FACILITY ..................................................................................................................................... 7 3. SUMMARY OF TEST RESULTS ............................................................................................ 8 4. REQUIREMENTS AND TEST PROCEDURES .................................................................... 9 4.1 DFS REQUIREMENT ............................................................................................................................. 9 4.2 TEST PROCEDURE .............................................................................................................................. 13 5. Test DATA AND RESULTS .................................................................................................... 14 5.1 RADAR WAVEFORM CALIBRATION .................................................................................................. 15 5.2 CHANNEL MOVE TIME AND CHANNEL CLOSING TRANSMISSION TIME ....................................... 16 5.2.1 Test Procedure ............................................................................................................................................. 16 5.2.2 Test Results .................................................................................................................................................. 16 5.3 NON-OCCUPANCY PERIOD ................................................................................................................. 17 5.3.1 Test Procedure ............................................................................................................................................. 17 5.3.2 Test Result ................................................................................................................................................... 17 APPENDIX A - EUT PHOTOGRAPHS .................................................................................... 18 APPENDIX B - TEST SETUP PHOTOGRAPHS .................................................................... 19 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402U81179E-RF-00F Report Template Version: DFS-V1.0 Page 3 of 19 DOCUMENT REVISION HISTORY Revision Number Report Number Description of Revision Date of Revision 1.0 2402U81179E-RF-00F Original Report 2024/7/25 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402U81179E-RF-00F Report Template Version: DFS-V1.0 Page 4 of 19 1. GENERAL INFORMATION 1.1 Product Description for Equipment under Test (EUT) EUT Name: Tablet EUT Model: T1001 Operation Frequency: 5250-5350MHz: 5260-5320 MHz (802.11a/n ht20/ac vht20) 5270-5310 MHz(802.11n ht40/ac vht40) 5290 MHz(802.11ac vht80) 5470-5725MHz: 5500-5700 MHz (802.11a/n ht20/ac vht20) 5510-5670 MHz(802.11n ht40/vht40) 5530-5610MHz(802.11ac vht80) Maximum Average Output Pβ¦
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 4 | 15E | 5.75 GHz - 5.83 GHz | 5.00 mW |
Mobile Phone
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterTablet
Equipment Class
DTS - Digital Transmission SystemMobile Phone
Equipment Class
PCE - PCS Licensed Transmitter held to earMobile Phone
Equipment Class
DTS - Digital Transmission SystemTablet
Equipment Class
NII - Unlicensed National Information Infrastructure TX