FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TECNO MOBILE LIMITED/
  3. 2ADYY-YYS-AE11

2ADYY-YYS-AE11Mobile Phone

TECNO MOBILE LIMITED

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 05, 2024
Application Purpose
Original Equipment
Date of Application
Sep 05, 2024
Equipment Note
Mobile Phone
Frequency Range
2412.00000000 - 2462.00000000
Company
TECNO MOBILE LIMITED
Country
Hong Kong

Documents & Files

Select a file to view

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

TECNO MOBILE LIMITED * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 8/30/2024 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2ADYY-YYS-AE11 FRN of Grantee: 0024206328 Per section 2.911(d)(7) of the FCC rules, TECNO MOBILE LIMITED (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Stariver Consulting Company FCC Registration Number (FRN): 0033610684 Company Address: 2363 James St #1098 Syracuse, NY 13206, USA Agent Name: Chong He Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed: Signed: Signed: Printed name: Yiting Luo Printed name: Chong He Title: Manager Title: Manager Company Name: TECNO MOBILE LIMITED Company Name: Stariver Consulting Company Date: 8/30/2024 Date: 8/30/2024

Cover Letter(s)

TECNO MOBILE LIMITED Date: 2024-8-11 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Compliance Testing, LLC.to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party t o the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). Sincerely, Dated this 2024-8-11 By: Yiting Luo Signature Printed Title: Manager On behalf of : INFINIX MOBILITY LIMITED Telephone: +86 0755-61803856

Cover Letter(s)

TECNO MOBILE LIMITED DATE:2024-8-11 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Mary land 21046 Authority to Act asAgent On our behalf, I appoint JianYan Testing Group Shenzhen Co., Ltd.; No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqia oStreet, Bao'an District, Shenzhen, Guangdong, People's Republic of China.; Bruce.Zhang, to act as our agent in the prepa ration of this a pplication for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For insta nces where our a uthorized agent signs the a pplication for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with TECNO MOBILE LIMITED / FL AT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Dated this 2024-8-11 By: Yiting Luo Signature Printed Title: Manager On behalf of : TECNO MOBILE LIMITED Telephone: +86 0755-61803856

Cover Letter(s)

TECNO MOBILE LIMITED DATE :2024-8-11 Equipment Autorisation Division Federal Communications Commission 7345 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ADYY-YYS-AE11 Product Name: Mobile Phone Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: Schematics  Block diagram  Operation description Tune up BOM These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 2024-8-11 By: Yiting Luo SignaturePrinted Title: Manager On behalf of : TECNO MOBILE LIMITED Telephone: +86 0755-61803856

Cover Letter(s)

TECNO MOBILE LIMITED DATE :2024-8-11 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2ADYY-YYS-AE11 Product Name: Mobile Phone Request for Short-Term Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission rules, and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705), we hereby request short-term confidentiality for the following items prior to marketing the device.: Test Setup Photos External Photos Internal Photos User Manual The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. <Signature> Name Yiting Luo Title Manager CompanyTECNO MOBILE LIMITED

RF Exposure Info

JianYan Testing Group Shenzhen Co., Ltd. Report No.: JYTSZ-R14-2400076 This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the JYT product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC SAR REPORT Report No.: JYTSZ-R14-2400076 Applicant: TECNO MOBILE LIMITED Address of Applicant: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Equipment Under Test (EUT) Product Name: Mobile Phone Model No.: AE11 Trade mark TECNO FCC ID: 22ADYY-YYS-AE11 Applicable standards: FCC 47 CFR Part 2.1093 Date of Test: 01 Aug., 2024 ~ 03 Aug., 2024 Test Result: Maximum Reported 1-g SAR (W/kg) Head: 1.159 Body: 1.189 Hotspot: 1.189 Project by: Date: 03 Sep, 2024 Project Engineer Reviewed by: Date: 03 Sep, 2024 Senior Engineer Approved by: Date: 03 Sep, 2024 Manager Report No.: JYTSZ-R14-2400076 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-287-C Project No.: JYTSZR2407005 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 2 of 72 2 Version Version No. Date Description 00 03 Sep, 2024 Original Report No.: JYTSZ-R14-2400076 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-287-C Project No.: JYTSZR2407005 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 3 of 72 3 Contents 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 SAR RESULTS SUMMARY ................................................................................................................................. 5 5 GENERAL INFORMATION .................................................................................................................................. 8 5.1 CLIENT INFORMATION ..................................................................................................................................................................... 8 5.2 GENERAL DESCRIPTION OF EUT ................................................................................................................................................... 8 5.3 MAXIMUM RF OUTPUT POWER .................................................................................................................................................... 11 5.4 ENVIRONMENT OF TEST SITE ....................................................................................................................................................... 14 5.5 TEST SAMPLE PLAN ..................................................................................................................................................................... 14 5.6 LABORATORY FACILITY ................................................................................................................................................................. 14 5.7 TEST LOCATION ........................................................................................................................................................................... 14 6 INTRODUCTION ................................................................................................................................................. 15 6.1 INTRODUCTION ............................................................................................................................................................................. 15 6.2 SAR DEFINITION .......................................................................................................................................................................... 15 7 RF EXPOSURE LIMITS ..................................................................................................................................... 16 7.1 UNCONTROLLED ENVIRONMENT ................................................................................................................................................... 16 7.2 CONTROLLED ENVIRONMENT ....................................................................................................................................................... 16 7.3 RF EXPOSURE LIMITS .................................................................................................................................................................. 16 8 SAR MEASUREMENT …

Text truncated - open the document above for the full version.

RF Exposure Info

Appendix C: System Calibration Certificate Calibration information for E-field probes Calibration information for Dipole Dipole Impedance and Return Loss Check Report Object: D835V2 - SN: 4d157 Check Date: June 02, 2023 Check reference: IEC/IEEE 62209-1528:2020, FCC KDB 865664 D01 Checked By: (Janet Wei, SAR project engineer) Reviewed By: (Winner Zhang, Technical manager) Environment of Test Site Temperature: 21 ~ 23C Humidity: 50~60% RH Atmospheric Pressure: 1011 mbar Test Data Measurement Plot for Head TSL In 2023 Comparison with Original report Items Checked By JYT In 2022 Checked By JYT In 2023 Deviation Limit Impendence for Head TSL 52.42Ω -1.46jΩ 49.63Ω -3.87jΩ -2.79Ω -2.41jΩ ±5Ω Return Loss for Head TSL -31.17 -28.17 -9.62% ±20%(No less than 20 dB) Result Compliance Dipole Impedance and Return Loss Check Report Object: D2450V2 - SN: 910 Check Date: June 03, 2024 Check reference: IEC/IEEE 62209-1528:2020, FCC KDB 865664 D01 Checked By: (Eric Wang, SAR project engineer) Reviewed By: (Janet Wei, manager) Environment of Test Site Temperature: 18 ~ 25C Humidity: 50~60% RH Atmospheric Pressure: 1011 mbar Test Data Measurement Plot for Head TSL In 2023 Comparison with Original report Items Checked By JYT In 2023 Checked By JYT In 2024 Deviation Limit Impendence for Head TSL 53.28Ω-0.28jΩ 57.78Ω-4.56jΩ 4.5Ω+4.28jΩ ±5Ω Return Loss for Head TSL -20.94dB -21.52dB 2.77% ±20%(No less than 20 dB) Result Compliance Dipole Impedance and Return Loss Check Report Object: D2600V2 - SN: 1114 Check Date: October 02, 2023 Check reference: IEC/IEEE 62209-1528:2020, FCC KDB 865664 D01 Checked By: (Eric Wang, SAR project engineer) Reviewed By: (Janet Wei, manager) Environment of Test Site Temperature: 18 ~ 25C Humidity: 50~60% RH Atmospheric Pressure: 1011 mbar Test Data Measurement Plot for Head TSL In 2023 Comparison with Original report Items Checked By JYT In 2022 Checked By JYT In 2023 Deviation Limit Impendence for Head TSL 51.1Ω-7.05jΩ 49.15Ω+7.58jΩ -1.95Ω+4.32jΩ ±5Ω Return Loss for Head TSL -23.10dB -22.30dB 2.86% ±20%(No less than 20 dB) Result Compliance Calibration information for DAE ------End of Report------

RF Exposure Info

JianYan Testing Group Shenzhen Co., Ltd. Report No.: JYTSZ-R14-2400021 This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the JYT product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC SAR REPORT Report No.: JYTSZ-R14-2400021 Applicant: TECNO MOBILE LIMITED Address of Applicant: FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT HONGKONG Equipment Under Test (EUT) Product Name: Mobile Phone Model No.: AE11 Trade mark TECNO FCC ID: 2ADYY-AE11 Applicable standards: FCC 47 CFR Part 2.1093 Date of Test: 30 Mar., 2024 ~ 24 May., 2024 Test Result: Maximum Reported 1-g SAR (W/kg) Head: 1.159 Body: 1.189 Hotspot: 1.189 Project by: Date: 30 May, 2024 Project Engineer Reviewed by: Date: 30 May, 2024 Senior Engineer Approved by: Date: 30 May, 2024 Manager Report No.: JYTSZ-R14-2400021 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-287-C Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 2 of 178 2 Version Version No. Date Description 00 30 May, 2024 Original Report No.: JYTSZ-R14-2400021 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-287-C Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 3 of 178 3 Contents 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 SAR RESULTS SUMMARY ................................................................................................................................. 5 5 GENERAL INFORMATION .................................................................................................................................. 8 5.1 CLIENT INFORMATION ..................................................................................................................................................................... 8 5.2 GENERAL DESCRIPTION OF EUT ................................................................................................................................................... 8 5.3 MAXIMUM RF OUTPUT POWER .................................................................................................................................................... 11 5.4 ENVIRONMENT OF TEST SITE ....................................................................................................................................................... 14 5.5 TEST SAMPLE PLAN ..................................................................................................................................................................... 14 5.6 LABORATORY FACILITY ................................................................................................................................................................. 14 5.7 TEST LOCATION ........................................................................................................................................................................... 14 6 INTRODUCTION ................................................................................................................................................. 15 6.1 INTRODUCTION ............................................................................................................................................................................. 15 6.2 SAR DEFINITION .......................................................................................................................................................................... 15 7 RF EXPOSURE LIMITS ..................................................................................................................................... 16 7.1 UNCONTROLLED ENVIRONMENT ................................................................................................................................................... 16 7.2 CONTROLLED ENVIRONMENT ....................................................................................................................................................... 16 7.3 RF EXPOSURE LIMITS .................................................................................................................................................................. 16 8 SAR MEASUREMENT SYS…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: JYTSZ-R14-2400021 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-287-C Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 86 of 178 15.7 SAR Simultaneous Transmission Analysis  Simultaneous Transmission Spacing and Position Standalone SAR 1g (W/kg) Σ SAR 1g (W/kg) LTE Band 2 LTE Band 5 LTE Band 7 LTE Band 66 NR n7 Max EN-DC 0mm Head Right Cheek 0.018 0.149 0.148 0.108 1.159 1.308 Right Tilted 0.004 0.054 0.107 0.061 0.673 0.780 Left Cheek 0.054 0.194 0.239 0.125 0.303 0.542 Left Tilted 0.032 0.069 0.342 0.074 0.181 0.523 10mm Body- worn Front 0.007 0.293 0.119 0.015 0.120 0.413 Back 0.007 0.324 0.155 0.018 0.157 0.481 Hotspot Front 0.007 0.293 0.119 0.015 0.120 0.413 Back 0.007 0.324 0.155 0.018 0.157 0.481 Left 0.000 0.166 0.000 0.000 0.290 0.456 Right 0.010 0.000 0.187 0.024 0.000 0.187 Top 0.003 0.000 0.069 0.015 0.060 0.130 Bottom 0.000 0.159 0.000 0.000 0.000 0.159 5mm Body- worn Front 0.032 0.127 0.243 0.064 0.364 0.364 Back 0.002 0.680 0.139 0.011 0.068 0.068 Hotspot Front 0.032 0.127 0.243 0.064 0.364 0.606 Back 0.002 0.680 0.139 0.011 0.068 0.748 Left 0.000 0.256 0.000 0.000 1.057 1.313 Right 0.031 0.000 0.502 0.054 0.000 0.502 Top 0.000 0.000 0.000 0.000 0.000 0.000 Bottom 0.017 0.237 0.100 0.009 0.000 0.420 Report No.: JYTSZ-R14-2400021 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-287-C Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 87 of 178 Spacing and Position Standalone SAR 1g (W/kg) ΣSAR 1g (W/kg) LTE Band 5 LTE Band 7 LTE Band 41 LTE Band 66(4) NR n41(n38) Max EN-DC 0mm Head Right Cheek 0.149 0.148 0.065 0.108 1.017 1.166 Right Tilted 0.054 0.107 0.058 0.061 0.753 0.814 Left Cheek 0.194 0.239 0.144 0.125 0.190 0.384 Left Tilted 0.069 0.342 0.121 0.074 0.150 0.270 10mm Body- worn Front 0.293 0.119 0.019 0.015 0.126 0.420 Back 0.324 0.155 0.023 0.018 0.149 0.473 Hotspot Front 0.293 0.119 0.019 0.015 0.126 0.420 Back 0.324 0.155 0.023 0.018 0.149 0.473 Left 0.166 0.000 0.000 0.000 0.288 0.454 Right 0.000 0.187 0.030 0.024 0.000 0.030 Top 0.000 0.069 0.012 0.015 0.057 0.072 Bottom 0.159 0.000 0.000 0.000 0.000 0.159 5mm Body- worn Front 0.127 0.243 0.062 0.064 0.368 0.368 Back 0.680 0.139 0.031 0.011 0.074 0.074 Hotspot Front 0.127 0.243 0.062 0.064 0.368 0.495 Back 0.680 0.139 0.031 0.011 0.074 0.754 Left 0.256 0.000 0.000 0.000 1.097 1.353 Right 0.000 0.502 0.053 0.054 0.000 0.054 Top 0.000 0.000 0.000 0.000 0.000 0.000 Bottom 0.237 0.100 0.025 0.009 0.189 0.426 Report No.: JYTSZ-R14-2400021 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-287-C Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 88 of 178 Spacing and Position Standalone SAR 1g (W/kg) Σ SAR 1g (W/kg) LTE Band 2 LTE Band 5 LTE Band 7 LTE Band 41 LTE Band 66 NR n77(n78) Max EN-DC 0mm Head Right Cheek 0.655 0.149 0.148 0.065 0.108 0.452 1.107 Right Tilted 0.153 0.054 0.107 0.058 0.061 0.201 0.354 Left Cheek 0.273 0.194 0.239 0.144 0.125 0.327 0.600 Left Tilted 0.075 0.069 0.342 0.121 0.074 0.128 0.470 10mm Body- worn Front 0.098 0.293 0.119 0.019 0.015 0.035 0.329 Back 0.077 0.324 0.155 0.023 0.018 0.066 0.389 Hotspot Front 0.098 0.293 0.119 0.019 0.015 0.035 0.329 Back 0.077 0.324 0.155 0.023 0.018 0.066 0.389 Left 0.134 0.166 0.000 0.000 0.000 0.014 0.180 Right 0.000 0.000 0.187 0.030 0.024 0.000 0.187 Top 0.020 0.000 0.069 0.012 0.015 0.013 0.082 Bottom 0.000 0.159 0.000 0.000 0.000 0.000 0.159 5mm Body- worn Front 0.182 0.127 0.243 0.062 0.064 0.110 0.110 Back 0.053 0.680 0.139 0.031 0.011 0.019 0.019 Hotspot Front 0.182 0.127 0.243 0.062 0.064 0.110 0.353 Back 0.053 0.680 0.139 0.031 0.011 0.019 0.698 Left 0.524 0.256 0.000 0.000 0.000 0.136 0.659 Right 0.000 0.000 0.502 0.053 0.054 0.000 0.502 Top 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Bottom 0.039 0.237 0.100 0.025 0.009 0.027 0.265 Report No.: JYTSZ-R14-2400021 JianYan Testing Group Shenzhen Co., Ltd. Report Template No.: JYTSZ4b-287-C Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 89 of 178 Spacing and Position Max Standalone SAR 1g (W/kg) Σ SAR 1g (W/kg) 1 2 4 5 6 1+2+6 1+4+5+6 MAX WWAN 2.4G MIMO 5G MIMO BT NFC 0mm Head Right Cheek 1.308 0.218 0.211 0.000 0.000 1.526 1.519 Right Tilted 0.860 0.134 0.088 0.000 0.000 0.994 0.948 Left Cheek 0.600 0.242 0.375 0.005 0.000 0.842 0.98 Left Tilted 0.523 0.260 0.168 0.011 0.000 0.783 0.702 10mm Body- worn Front 0.480 0.065 0.062 0.007 0.000 0.545 0.549 Back 0.606 0.034 0.018 0.000 0.000 0.64 0.624 Hotspot Front 0.480 0.065 0.062 0.007 0.000 0.545 0.549 Back 0.606 0.034 0.015 0.000 0.000 0.64 0.621 Left 0.676 0.062 0.029 0.000 0.000 0.738 0.705 Right 0.187 0.004 0.008 0.004 0.000 0.191 0.199 Top 0.215 0.046 0.011 0.003 0.000 0.261 0.229 Bottom 0.251 0.000 0.000 0.000 0.000 0.251 0.251 5mm Body- worn Front 0.673 0.329 0.060 0.000 0.000 1.002 0.733 Back 1.189 0.078 0.008 0.000 0.000 1.267 1.197 Hotspot Front 0.673 0.329 0.060 0.005 0.000 1.002 0.738 Back 1.189 0.078 0.008 0.000 0.000 1.267 1.197 Left 1.353 0.229 0.124 0.000 0.000 1.582 1.477 Right 0.502 0.017 0.010 0.005 0.000 0.519 0.517 Top 0.000 0.147 0.…

Text truncated - open the document above for the full version.

RF Exposure Info

JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 1 of 81 Appendix C: System Calibration Certificate JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 2 of 81 Calibration information for E-field probes JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 3 of 81 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 4 of 81 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 5 of 81 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 6 of 81 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 7 of 81 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 8 of 81 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 9 of 81 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 10 of 81 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 11 of 81 Calibration information for Dipole JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected] Page 12 of 81 JianYan Testing Group Shenzhen Co., Ltd. Project No.: JYTSZR2403016 No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'an District, Shenzhen, Guangdong,People's Republic of China. Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail:[email protected]…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yiting Luo
[email protected]86-755-61803856Fax: +86-755-33979211

Test Firm

JianYan Testing Group Shenzhen Co., Ltd.Bruce Zhang
[email protected]+86 (0) 755 23118282

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz46.13 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device is approved for use in the handset described in this filing. SAR compliance for body-worn operations is restricted to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 1 cm separation between the device including its antenna and the body of user. End-users must be informed of the body-worn accessory operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission exposure conditions are 0.26 W/kg, 0.33 W/kg, 0.33 W/kg, and 1.58 W/kg, respectively.

Other Applications from TECNO MOBILE LIMITED

2ADYY-KO2

Mobile Phone

Sep 16, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2ADYY-T1002W

Tablet

Jun 10, 2026

Equipment Class

DTS - Digital Transmission System
2ADYY-KN4N

Mobile Phone

Jun 08, 2026

Equipment Class

PCE - PCS Licensed Transmitter held to ear
2ADYY-CN6

Mobile Phone

Jun 05, 2026

Equipment Class

DTS - Digital Transmission System
2ADYY-T1103

Tablet

May 25, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX