Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
istory of diseases sƟmulated by heat, such as recurrent herpes simplex (cold sores) in the treatment area, unless treated by following a prevenƟve regimen. Do not use if you have any acƟve skin condiƟon in the treatment area, such as sores, psoriasis, eczema, and rash and rosacea. Do not use if you have a history of significant post‐inflammatory hyperpigmentaƟon at the sites of acne lesions. Do not use if have a history of skin cancer, or any other type of cancer, or pre‐malignant moles. Do not use if you are using isotreƟnoin (Accutane/Roaccutane, Amnesteem, Claravis) or any other systemic reƟnoid. Do not use if you are pregnant, nursing or undergoing ferƟlity treatments. WHO SHOULD USE NIRA—ANTI‐AGING When used as directed, the NIRA BEAUTY Skincare Laser visibly smoothes and diminishes fine lines and wrinkles around the eyes and mouth.
POTENTIAL SIDE EFFECTS ACHIEVING BEST RESULTS PC Setup & Web‐Portal 1. Open web browser and go to www.nirabeauty.com/setup.exe. 2. Download file. Browser may warn against downloading file. The file is safe; click “Download anyway” or “Keep” depending on the browser. 3. Run setup.exe. 4. Follow instrucƟons to install NIRA tool and STM Driver. Both will install automaƟcally. Click on Close and Finish when each is done. 5. The NIRA tool will automaƟcally start and you will see the NIRA star icon in your desktop tray. 6. Connect your device using the USB cable. The desktop icon will turn green when connected to your PC. 7. The web browser will launch the NIRA registraƟon page. Complete and submit. 8. The web browser will launch NIRA web portal login page (my.nirabeauty.com). Login and start using your NIRA BEAUTY Skincare Laser. Note: Your device will sync the data with the server automaƟcally when plugged in; you may disconnect your device anyƟme once the lights just under the NIRA logo stop rotaƟng.
Label Location
SAR Exclusion Per 447498 D01 General RF Exposure Guidance v05r02 4.3.1 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR 0.186209mW 5mm 2.48GHz 0.058648<7.5Therefore SAR exclusion is applicable
Curtis-Straus LLC is accredited by the American Association for Laboratory Accreditation for the specific scope of accreditation under Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation. ____________________________________________________________ Curtis-Straus LLC, a wholly owned subsidiary of BV CPS One Distribution Center Circle, #1 Littleton, MA TEL (978) 486-8880 FAX (978) 486-8828 page 1 of 23 Test Report Curtis-Straus LLC, a wholly owned subsidiary of BV CPS Report No EN2540-1 Client Dermal Photonics Corporation Paul Dunleavy Address 5 Elms Street, Suite 10 Danvers, MA 01923 Phone 603-264-3405 Items tested NIRA LASER SYSTEM FCC ID 2ADZENIRA FRN 0024210494 Equipment Type Part 15.247 Digitally Modulated Equipment Code DTS FCC Rule Parts 47 CFR 15.247 Test Dates October 9-10, 13, 22 and 30, 2014 Results As detailed within this report Prepared by Tuyen Truong A. – Test Engineer Authorized by Christopher Reynolds – EMC Supervisor Issue Date 5/18/2015 Conditions of Issue This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’ section on page 22 of this report. Test Report for Dermal Photonics Corporation. Report No. EN2540-1 April 23, 2015 ______________________________________________________________________ ____________________________________________________________ Curtis-Straus LLC, a wholly owned subsidiary of BV CPS One Distribution Center Circle, #1 Littleton, MA TEL (978) 486-8880 FAX (978) 486-8828 page 2 of 23 Contents Contents .................................................................................................................................. 2 Summary ................................................................................................................................. 3 Test Methodology .................................................................................................................... 4 Product Tested - Configuration Documentation ....................................................................... 5 Statement of Conformity ...................................................................................................... 6 Test Results ............................................................................................................................ 7 Bandwidth ............................................................................................................................ 7 Fundamental Emission Output Power ................................................................................ 10 Radiated Spurious Emissions ............................................................................................ 13 Power Spectral Density ...................................................................................................... 16 AC Line Conducted Emissions ........................................................................................... 19 Duty Cycle Correction Calculation ...................................................................................... 20 Measurement Uncertainty...................................................................................................... 21 Conditions Of Testing ............................................................................................................ 22 Form Final Report REV 7-20-07 (DW) Test Report for Dermal Photonics Corporation. Report No. EN2540-1 April 23, 2015 ______________________________________________________________________ Issue No. Reason for change Date Issued 1 Original Release April 23, 2015 _____________________________________________________________ Curtis-Straus LLC, a wholly owned subsidiary of BV CPS One Distribution Center Circle, #1 Littleton, MA TEL (978) 486-8880 FAX (978) 486-8828 page 3 of 23 Summary This test report supports an application for certification of a transmitter operating pursuant to 47 CFR 15.247. The product is the NIRA LASER SYSTEM. It is a digitally modulated transmitter that operates in the range 2402-2480MHz. Product was tested with an on board antenna with a gain of -3.5dBi. We found that the products met the above requirements without modification. Paul Dunleavy from Dermal Photonics Corporation was present during the testing. The test sample was received in good condition. Please note that EUT was only tested in Bluetooth Transmit mode with Battery powered. The client states that the device can only transmit in Battery mode (i.e. not while connected to the AC charger) Test Report for Dermal Photonics Corporation. Report No. EN2540-1 April 23, 2015 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus LLC, a wholly owned subsidiary of BV CPS One Distribution Center Circle, #1 Littleton, MA TEL (978) 486-8880 FAX (978) 486-8828 page 4 of 23 Test Methodology Radiated emission and AC Line conducted testing were performed according to DTS guidance document 558074D01 v03r02 specified in FCC Guidance for performing compliance measurement on DTS operating under section 15.247, April 19, 2013 and ANSI C63.10 (2009) and C63.4 (2003). Radiated Emissions were maximized by rotating the device around its axes as well as varying the test antenna’s height and polarity. The device antenna was not maximized separately. Conducted emissions at the antenna port were not performed since the EUT antenna was permanently attached. AC Main conducted emission was not performed with a 50Ω/50μH because the device shall only able to be used with battery powered and not while charging. Low operating channel frequency = 2402MHz Mid operating channel frequency = 2440MHz High operating channel frequency = 2480MHz The following bandwidths were used during radiated spurious and line conducted emissions. Frequency RBW VBW 0.15-30MHz 9kHz 30kHz 30-1000MHz 120kHz 1MHz 1-10GHz 1MHz 3MHz Test Report for …
Text truncated - open the document above for the full version.
Radiated Emission EMI Radiated – Mid Range EMI Radiated – Rear (High Range) EMI Radiated – Front (High Range) X - Orientation Y- Orientation Z – Orientation Environmental Testing Environmental testing – Overview Set Up Closed up View
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 417.00 µW |

Bluetooth temperature monitoring device
Equipment Class
DTS - Digital Transmission System