2ADZNHX999Rechargeable Electric Toothbrush

Philips Oral Healthcare, Inc.
Rechargeable Electric Toothbrush - FCC ID 2ADZNHX999 - Philips Oral Healthcare, Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 26, 2021
Application Purpose
Original Equipment
Date of Application
Apr 26, 2021
Equipment Note
Rechargeable Electric Toothbrush
Frequency Range
2402.00000000 - 2480.00000000
Company
Philips Oral Healthcare, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

9900 Prestige idml_export_757_72.indd 1idml_export_757_72.indd 108-02-21 14:0408-02-21 14:04 idml_export_757_72.indd 2idml_export_757_72.indd 208-02-21 14:0408-02-21 14:04 1 4 5 6 7 9 10 2 3 13 14 8 1615 12 11 idml_export_757_72.indd 3idml_export_757_72.indd 308-02-21 14:0408-02-21 14:04 empty page before TOC idml_export_757_72.indd 4idml_export_757_72.indd 408-02-21 14:0408-02-21 14:04 English 6 Español 33 Français (Canada) 62 idml_export_757_72.indd 5idml_export_757_72.indd 508-02-21 14:0408-02-21 14:04 English 6English Introduction Congratulations on your new Philips Sonicare power toothbrush! Superior plaque removal, whiter teeth, and healthier gums are at your fingertips. Using Sonicare’s combination of gentle sonic technology and clinically developed and proven features, you can be confident that you’re getting the very best clean, every time. Further support and product registration are available to you at: www.philips.com/Prestige-Get-Started Welcome to the Philips Sonicare family! IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USE Read this user manual carefully before you use the appliance and save it for future reference. When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following: DANGERS To reduce the risk of electrocution: - Keep the USB wall adapter and chargers away from water. idml_export_757_72.indd 6idml_export_757_72.indd 608-02-21 14:0408-02-21 14:04 7English - Do not place or store product where it can fall or be pulled into a tub or sink. - Do not place in or drop into water or other liquid. - Do not immerse the charger in water or any other liquid. - Do not reach for a product that has fallen into water. Unplug immediately. - Do not use while bathing. - After cleaning, make sure the USB wall adapter is completely dry before you connect it to a power outlet. WARNINGS To reduce the risk of burns, electrocution, fire or physical injury: - Never use the USB wall adapter if it is damaged. - If the appliance is damaged in any way (brush head, toothbrush handle, USB wall adapter, charging travel case and/or charger), stop using it. - This appliance contains no user serviceable parts. If the appliance is damaged, contact the Consumer Care Center in your country (see 'Warranty and support'). - The charging base's cord cannot be replaced. If the charging base cord is damaged, discard the charging base. - Always have the USB wall adapters and chargers replaced with one of the original type in order to avoid a hazard. - Keep cord away from heated surfaces. - Do not use the charger outdoors. - Do not use the charger if dropped into water. - This product is designed to clean your teeth, gums and tongue only. Use this product only for its intended use as described in this booklet. Discontinue use of this product and contact a physician/dentist if discomfort or pain is experienced. idml_export_757_72.indd 7idml_export_757_72.indd 708-02-21 14:0408-02-21 14:04 8English - This appliance may be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, if they have been given supervision or instruction concerning the safe use of the appliance and understand the hazards involved. Cleaning and user maintenance shall not be performed by children without supervision. - Children shall not play with the appliance. - Do not use attachments other than those recommended by Philips Sonicare. - To avoid damage to the product, do not place the brush head, handle, charger or charger covers in the dishwasher for cleaning. MEDICAL WARNINGS - Consult your dental professional before you use this product if you have had oral or gum surgery in the previous 2 months. - Contact your dental professional if excessive bleeding occurs after using this product or bleeding continues to occur after 1 week of use. - If you have a pacemaker or other implanted device contact your physician or the device manufacturer prior to use. - Sonicare has been tested and is compliant with safety standards for electromagnetic devices. - Consult your physician prior to using the Sonicare if you have medical concerns. Battery safety instructions - Only use this product for its intended purpose and follow the general and battery safety instructions as described in this user manual. Any misuse can cause electric shock, burns, fire and other hazards or injuries. idml_export_757_72.indd 8idml_export_757_72.indd 808-02-21 14:0408-02-21 14:04 9English - To charge the battery, only use the USB wall adapter, charging base and charging travel case provided with the product: WAA1001, WAA200, HX9200 or HX9200/B, and TCC1001, TCC2001, TCC3001, CBB1001 or CBB2001. Do not use an extension cord. - Charge, use and store the product at a temperature between 0 °C and 40 °C. - Do not burn products and their batteries and do not expose them to direct sunlight or to high temperatures (e.g. in hot cars or near hot stoves). Batteries may explode if overheated. - If the product becomes abnormally hot, gives off an abnormal smell, changes color or if charging takes much longer than usual, stop using and charging the product and contact Philips support directly or a Philips service center at www.philips.com/support, or toll free at 1-800-682-7664. - Do not place products and their batteries in microwave ovens or on induction cookers. - This product contains a rechargeable battery that is non- replaceable. Do not open the product to replace the rechargeable battery during the usable life of your device. - When you handle batteries, make sure that your hands, the product and the batteries are dry. - To prevent batteries from heating up or releasing toxic or hazardous substances, do not modify, pierce or damage products and batteries and do not disassemble, short-circuit, overcharge or reverse charge batteries during the usable life of your device. - To avoid accidental short-cir…

Text truncated - open the document above for the full version.

Cover Letter(s)

_ _ Philips Oral Healthcare LLC 22100 Bothell Everett Hwy, Bothell, WA 98021 www.philips.com April 1, 2021 Attention: Application Examiner RE: Request for Confidentiality Applicant: Philips Oral Healthcare LLC FCC ID: 2ADZNHX999 To Whom It May Concern: Permanent Confidentiality Request is hereby submitted by Philips Oral Healthcare LLC to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential:  Schematics  Detailed Block Diagrams  Detailed Operational/Functional Description Short-term Confidentiality Request is hereby submitted by Philips Oral Healthcare LLC to withhold from public review for a period of 45 days from the date of the Grant of Equipment Authorization and prior to marketing, certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept confidential for a period of 45 days from the date of Authorization:  Test setup photos  External photos Date: 2014-03-17 Page: 2 _ _  Internal photos  User manual Rationale for request for confidentiality: Philips Oral Healthcare LLC has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. Disclosure of the short-term confidential portions of this application during the period of importation and/or distribution would reveal key aspects of proprietary technology to competitors and diminish the value of our investment in research and development. If you have questions or need further information, please contact the undersigned. Sincerely, [Signature] Matthew Vasa Engineer, Safety and Approbation Philips Oral Healthcare LLC

Cover Letter(s)

_ _ Philips Oral Healthcare LLC 22100 Bothell Everett Hwy, Bothell, WA 98021 www.philips.com April 1, 2021 Federal Communications Commission 445 12 th Street SW Washington, DC 20554 Subject: Limited Agency Agreement Philips Oral Healthcare LLC FCC ID: 2ADZNHX99 To Whom It May Concern: We, Philips Oral Healthcare LLC, hereby authorized Intertek Testing Services to act as our Agent for the purpose of preparing application for FCC ID number 2ADZNHX99 under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is April 1, 2021. The Limited Agency Agreement expires on June 1, 2021, unless sooner terminated or extended by written notice to Intertek Testing Services and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, Date: 2021-04-01 Page: 2 _ _ [Signature] Matthew Vasa Engineer, Safety and Approbation

External Photos

Philips Oral Healthcare LLC 22100 Bothell Everett Hwy, Bothell, WA 98021 www.philips.com External Photos Date: 2021-04-05 Page: 2 _ _ Date: 2021-04-05 Page: 3 _ _ Date: 2021-04-05 Page: 4 _ _ Date: 2021-04-05 Page: 5 _ _ Date: 2021-04-05 Page: 6 _ _ Date: 2021-04-05 Page: 7 _ _ Date: 2021-04-05 Page: 8 _ _ Date: 2021-04-05 Page: 9 _ _ Date: 2021-04-05 Page: 10 _ _ Date: 2021-04-05 Page: 11 _ _ Date: 2021-04-05 Page: 12 _ _

ID Label/Location Info

PLM VERSION DESCRIPTION BY APR A N OTES: 1. PLACEMENT ON THE PART IS PER USED-ON DRAWING AND PROFILE SHOWN BELOW. 2. GRAPHICS SHOWN ARE FOR INSPECTION PURPOSES ONLY. CONTACT PHILIPS FOR ELECTRONIC GRAPHIC ARTWORK FILES. 3. REFER FIGURE 1 FOR HX NUMBER AND DATE CODE PLACEMENT LOCATION DETAIL S 4. HX NUMBER AND DATE CODE ARE LASER ETCH VARIABLES, REFER FIGURE 2 FOR FONT REQUIREMENTS *** Confidential *** THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION THAT IS THE SOLE PROPERTY OF PHILIPS. DISTRIBUTION, REPRODUCTION OR USE BY OTHERS IS NOT PERMITTED WITHOUT THE WRITTEN PERMISSION OF PHILIPS.  2021 PHILIPS ELECTRONICS NORTH AMERICA CORPORATION DESCRIPTION: ARTWORK_END PLUG_XIAN_NA/EU_ (EXCEPT UKRAINE & RUSSIA) PREPARED: DATE: 21-01-13 SIZE: N/A DOCUMENT NO: D000706118 PLM VERSION APPROVED: ANDREAS GARDEBACK DATE: SH: 166 SHEET: 1 OF 1 FIGURE 2 SCALE 1:1 SCALE 3:1 FIGURE 1 INITIAL RELEASE 21-01-13 A JJEAG JIM JOSE 5. BLUE LINES INDICATE PART BOUNDARIES AND FEATURES. USE BLUE LINES FOR ARTWORK POSTIONING WITHIN ±0.3MM. ORIENT AS SHOWN WITHIN ±3°. Laser variable text font requirements RED=Variable text Font: Calibri Bold (MS Windows) Size: 9pt (2.0mm) Line spacing: 7.8pr (0.73mm) Alignment: Center Sample: ABCDEFGHIJKLMNOPQRSTU- VWXYZ 1234567890

Internal Photos

Philips Oral Healthcare LLC 22100 Bothell Everett Hwy, Bothell, WA 98021 www.philips.com Internal Photos Date: 2021-04-05 Page: 2 Date: 2021-04-05 Page: 3 Date: 2021-04-05 Page: 4 Date: 2021-04-05 Page: 5 Date: 2021-04-05 Page: 6 Date: 2021-04-05 Page: 7 Date: 2021-04-05 Page: 8 Date: 2021-04-05 Page: 9

RF Exposure Info

Philips Oral Healthcare LLC RF Exposure Exhibit SCOPE OF WORK EMC TESTING – Rechargeable Electric Toothbrush Handle, Model: HX999C REPORT NUMBER 104498238MPK-015 ISSUE DATE March 11, 2021 REVISED DATE N/A PAGES 8 DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. December 2017 MPK © 2017 INTERTEK Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle Page 2 of 8 RF Exposure Exhibit (Portable devices) Report Number: 104498238MPK-015 Project Number: G104498238 Report Issue Date: March 11, 2021 Product Designation: Model Tested: Rechargeable Electric Toothbrush Handle HX999C FCC ID: 2ADZNHX999 IC: 20109-HX999 to 47CFR 2.1093 RSS-102 Issue 5 for Philips Oral Healthcare LLC Tested by: Client: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Philips Oral Healthcare LLC 22100 Bothell Everett Highway Bothell, WA 98021 USA Report prepared by: Report reviewed by: Aaron Chang / Project Engineer Krishna Vemuri / EMC Manager This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. REPORT NUMBER: 104498238MPK-015 Issued: March 11, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle Page 3 of 8 Report No. 104498238MPK-015 Equipment Under Test: Rechargeable Electric Toothbrush Handle Trade Name: Philips Oral Healthcare LLC Model(s) Tested: HX999C Applicant: Philips Oral Healthcare LLC Contact: Cathy Burton Address: Philips Oral Healthcare LLC. 22100 Bothell Everett Highway Bothell, WA 98021 USA Country: USA Tel. Number: (425) 487-7000 Email: [email protected] Applicable Regulation: 47CFR 2.1093 RSS-102 Issue 5 REPORT NUMBER: 104498238MPK-015 Issued: March 11, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle Page 4 of 8 TABLE OF CONTENTS 1.0 RF Exposure Summary ................................................................................................................... 5 2.0 RF Exposure Limits ........................................................................................................................ 5 3.0 Test Results (Portable Configuration) .......................................................................................... 6 4.0 Document History ........................................................................................................................... 8 REPORT NUMBER: 104498238MPK-015 Issued: March 11, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle Page 5 of 8 1.0 RF Exposure Summary Test Reference FCC Reference Industry Canada Result Radio frequency Radiation Exposure Evaluation 47 CFR§2.1093 RSS-102 Issue 5 Complies 2.0 RF Exposure Limits 2.1 FCC Limits According to FCC KDB 447498 D01 v06 Appendix A, at frequency 2450 MHz and separation distance of ≤ 5 mm SAR Exemption limit is ≤ 10 mW. Note: 10-g Extremity SAR Test Exclusion Power Thresholds are 2.5 times higher than the 1-g SAR Test Exclusion Thresholds indicated above. 2.2 Industry Canada Limits According to RSS-102 sec. 2.5.1 table 1, at frequency 2450 MHz and separation distance of ≤ 5 mm SAR Exemption limit is ≤ 4 mW. Note: For limb-worn devices where the 10 gram value applies, the exemption limits for routine evaluation in Table 1 of RSS-102 are multiplied by a factor of 2.5. REPORT NUMBER: 104498238MPK-015 Issued: March 11, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle Page 6 of 8 3.0 Test Results (Portable Configuration) 3.1 Classification For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Per the applicant, the Rechargeable Electric Toothbrush Handle is intended to be worn at the knees. 3.2 EIRP calculations The Rechargeable Electric Toothbrush Handle consists of Bluetooth Low Energy radio. 3.3 Maximum RF Power Fr equency Range (MHz) RF Output (dBm) Antenna Gain 1 (dBi) Note 2402-2480 0.60 -5.0 Conducted power measurements were taken from Report # 104498238MPK-001. 1 As declared by the manufacturer. REPORT NUMBER: 104498238MPK-015 Issued: March 11, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle Page 7 of 8 3.4 RF Exposure Calculation for Rechargeable Electric Toothbrush Handle 3.4.1 RF Exposure calculation for FCC KDB 447498 D01 v06 According to FCC KDB 447498 D01 v06 Appendix A, at frequency 2450 MHz and separation distance of ≤ 5 mm SAR Exemption limit is ≤ 10 mW. Max Peak Conducted Power measured = 0.60 dBm or 1.148 mW No duty cycle was considered. Therefore, the Maximum EIRP calculated is 0.60 dBm (RF Conducted Power) + 0 dBi (Antenna Gain) = 0.60 dBm or 1.148 mW. Results: SAR evaluation is not requir…

Text truncated - open the document above for the full version.

Test Report

EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle File: 104498238MPK-001 Page 1 of 48 TEST REPORT Report Number: 104498238MPK-001 Project Numbers: G104498238 Report Issue Date: March 04, 2021 Testing performed on Rechargeable Electric Toothbrush Handle Model Number: HX999C FCC ID: 2ADZNHX999 IC: 20109-HX999 to FCC Part 15 Subpar t C (15.247) ISED RSS-247 Issue 2 For Philips Oral Healthcare LLC Test Performed by: Test Authorized by: Intertek 1365 Adams Court Menlo Park, CA 94025 USA Philips Oral Healthcare LLC 22100 Bothell Everett Highway Bothell, WA 98021 USA Prepared by: Date: March 04, 2021 Hung Huynh Reviewed by: Date: March 04, 2021 Krishna K Vemuri This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Cli ent. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Inter tek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle File: 104498238MPK-001 Page 2 of 48 Report No. 104498238MPK-001 Equipment Under Test: Rechargeable Electric Toothbrush Handle Model Number: HX999C Applicant: Philips Oral Healthcare LLC Contact: Cathy Burton Address: Philips Oral Healthcare LLC 22100 Bothell Everett Highway Bothell, WA 98021 Country: USA Tel. Number: (425) 487-7000 Email: [email protected] Applicable Regulation: FCC Part 15 Subpart C (15.247) ISED RSS-247 Issue 2 Date of Test: February 01, 2021 to February 28, 2021 We attest to the accuracy of this report: Hung Huynh Project Engineer Krishna K Vemuri EMC Manager EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle File: 104498238MPK-001 Page 3 of 48 TABLE OF CONTENTS 1.0 Summary of Tests ................................................................................................................. 4 2.0 General Information ............................................................................................................. 5 2.1 Product Description ............................................................................................................ 5 2.2 Related Submittal(s) Grants ................................................................................................ 6 2.3 Test Facility ......................................................................................................................... 6 2.4 Test Methodology ............................................................................................................... 6 2.5 Measurement Uncertainty ................................................................................................. 6 3.0 System Test Configuration ..................................................................................................... 7 3.1 Support Equipment ............................................................................................................. 7 3.2 Block Diagram of Test Setup ............................................................................................... 7 3.3 Justification ......................................................................................................................... 8 3.4 Software Exercise Program ................................................................................................. 8 3.5 Mode of Operation during Test .......................................................................................... 8 3.6 Modifications Required for Compliance ............................................................................. 8 3.7 Additions, Deviations and Exclusions from Standards ........................................................ 8 4.0 Measurement Results ........................................................................................................... 9 4.1 6-dB Bandwidth and 99% Occupied Bandwidth ................................................................. 9 4.2 Maximum Peak Conducted Output Power at Antenna Terminals ................................... 17 4.3 Maximum Power Spectral Density .................................................................................... 21 4.4 Out of Band Antenna Conducted Emission....................................................................... 25 4.5 Transmitter Radiated Emissions ....................................................................................... 29 4.6 AC Line Conducted Emission ............................................................................................. 46 5.0 List of Test Equipment .......................................................................................................... 47 6.0 Document History ................................................................................................................ 48 EMC Report for Philips Oral Healthcare LLC on the Rechargeable Electric Toothbrush Handle File: 104498238MPK-001 Page 4 of 48 1.0 Summary of Tests Test Reference FCC Reference Industry Canada Result RF Output Power 15.247(b)(3) RSS-247, 5.4.d) Complies 6 dB Bandwidth 15.247(a)(2) RSS-247, 5.2.a) Complies Power Density 15.247(e) RSS-247, 5.2.b) Complies Out of B…

Text truncated - open the document above for the full version.

Test Setup Photos

Model Number: HX999C FCC ID: 2ADZNHX999 IC: 20109-HX999 For Philips Oral Healthcare LLC 22100 Bothell Everett Highway Bothell, WA 98021 USA EUT Photo 15.247 Test Setup Photos 15.225 Setup Photos 4.1.5 Test Configuration Photographs (Continued) 4.1.5 Test Configuration Photographs (Continued)

Contact Information

Applicant

Matthew Vasa(Compliance Engineer, Philips Oral Healthcare)
[email protected]425-482-8367Fax: 425-482-8367

Technical Contact

Philips Oral Healthcare, IncBrian Clarke
[email protected]5084226928

22100 Bothell-Everett Highway · Bothell, Washington · United States

Test Firm

IntertekTesting Services NA Inc.Charles Parker
[email protected]650-463-2900Fax: 650 463 2910

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except as in accordance with FCC multi- transmitter product guidelines.

Other Applications from Philips Oral Healthcare, Inc.

Power toothbrush - FCC ID 2ADZNHX991 - Philips Oral Healthcare, Inc.
2ADZNHX991

Power toothbrush

Jun 15, 2020

Equipment Class

DTS - Digital Transmission System
The device is a battery powered rechargeable toothbrush that can connect to a customer device such as a cellular phone or note pad via BLE. - FCC ID 2ADZNHX63 - Philips Oral Healthcare, Inc.
2ADZNHX63

The device is a battery powered rechargeable toothbrush that can connect to a customer device such as a cellular phone or note pad via BLE.

May 25, 2015

Equipment Class

DTS - Digital Transmission System