FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD/
  3. 2AEDG-P4106

2AEDG-P4106PETKIT EVERSWEET 5 MINI SMART PET DRINKING FOUNTAIN

PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD
PETKIT EVERSWEET 5 MINI SMART PET DRINKING FOUNTAIN - FCC ID 2AEDG-P4106 - PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 14, 2021
Application Purpose
Original Equipment
Date of Application
Jul 14, 2021
Equipment Note
PETKIT EVERSWEET 5 MINI SMART PET DRINKING FOUNTAIN
Frequency Range
2402.00000000 - 2480.00000000
Company
PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

( PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO., LTD) Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AEDG-P4106 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram, Schematics, Operational Description Block Diagram .pdf, Schematics .pdf , Operation Description .pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: Short-term confidentiality requested: 180 days Exhibit Type File Name Internal Photos, Test Setup Photos, Manual Internal Photos .pdf, Test Setup Photos .pdf, User Manual .pdf Sincerely, Huili zhang/chief inspector PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO., LTD

Cover Letter(s)

(PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO., LTD) Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: July 09, 2021 SUBJECT: FCC Application for FCC ID: 2AEDG-P4106 To Whom It May Concern: We, the undersigned, hereby authorize Tony Wei at EMTEK(NINGBO) CO., LTD. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by EMTEK(NINGBO) CO., LTD. on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Huili zhang/chief inspector PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO., LTD

External Photos

External photos: ---The End---

ID Label/Location Info

Label Location

Internal Photos

Internal photos: ---The End--- Antenna

RF Exposure Info

FCC ID: 2AEDG-P4106 RF EXPOSURE EVALUATION According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in §1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density(mW/cm 2 ) Average Time (A) Limits for Occupational/Control Exposures 300-1500 -- -- F/300 6 1500-100000 -- -- 5 6 (B) Limits for General Population/Uncontrol Exposures 300-1500 -- -- F/1500 6 1500-100000 -- -- 1 30 11.1 Friis transmission formula: Pd= (Pout*G)\ (4*pi*R 2 ) Where Pd= Power density in mW/cm 2 Pout=output power to antenna in mW G= Numeric gain of the antenna relative to isotropic antenna Pi=3.1416 R= distance between observation point and center of the radiator in cm Pd the limit of MPE,1mW/cm 2 . If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. mW = 10^( dBm/10) 11.2 Measurement Result Operation Frequency: 2402MHz-2480MHz; Antenna gain: 0.0 dBi; R=20cm BLE 1M Channel Freq. (MHz) modulation Measured power (dBm) Tune-up power (dBm) Max tune-up power (dBm) Antenna Gain Numeric Evaluation result (mW/cm2) Power density Limits (mW/cm2 ) 2402 GFSK -2.083 -2±1 -1 1.0 0.000158026 1 2440 -2.387 -2±1 -1 1.0 0.000158026 1 2480 -2.058 -2±1 -1 1.0 0.000158026 1 BLE 2M Channel Freq. (MHz) modulation Measured power (dBm) Tune-up power (dBm) Max tune-up power (dBm) Antenna Gain Numeric Evaluation result (mW/cm2) Power density Limits (mW/cm2 ) 2402 GFSK -2.146 -2±1 -1 1.0 0.000158026 1 2440 -2.413 -2±1 -1 1.0 0.000158026 1 2480 -2.063 -2±1 -1 1.0 0.000158026 1 *** End of Report ***

Test Setup Photos

Conducted Radiated ---The End---

Contact Information

Applicant

Huili Zhang
[email protected]021-51355816Fax: 021-51355817

Test Firm

EMTEK (NINGBO) Co., Ltd.Tony Wei
[email protected]860574279079981011

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz620.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted output power. Device must be operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD

PETKIT FIT 3 - FCC ID 2AEDG-PP130 - PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD
2AEDG-PP130

PETKIT FIT 3

Aug 25, 2021

Equipment Class

DTS - Digital Transmission System
ERARK SMART FISH TANK - FCC ID 2AEDG-E410 - PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD
2AEDG-E410

ERARK SMART FISH TANK

Jan 11, 2021

Equipment Class

DTS - Digital Transmission System
PETKIT FRESH ELEMENT 3 - FCC ID 2AEDG-P560 - PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD
2AEDG-P560

PETKIT FRESH ELEMENT 3

Jan 06, 2021

Equipment Class

DTS - Digital Transmission System
PETKIT AIR MAGICUBE SMART ODOR ELIMINATOR - FCC ID 2AEDG-P9201 - PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD
2AEDG-P9201

PETKIT AIR MAGICUBE SMART ODOR ELIMINATOR

Jul 15, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Petkit P2 - FCC ID 2AEDGP220 - PETKIT NETWORK TECHNOLOGY (SHANGHAI) CO.,LTD
2AEDGP220

Petkit P2

May 04, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter