Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
GSM GLOBE.COM INC 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – EquipmentType Company name: GSM GLOBE.COM INC Address: 10286 SW 22nd pl. Davie, Florida 33324, United States Product Name: MOBILE PHONE FCC ID: 2AEJARAYOGO Model(s): GO 2.911(d)(5)(i) EquipmentType We, [GSM GLOBE.COM INC] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: • Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. • Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Zubair Panjwani Date: 2024-08-28 Title and Company name: Director /GSM GLOBE.COM INC NOTE 1 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
GSM GLOBE.COM INC 2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: GSM GLOBE.COM INC Address: 10286 SW 22nd pl. Davie, Florida 33324, United States Product Name: MOBILE PHONE FCC ID: 2AEJARAYOGO Model(s): GO 2.911(d)(5)(ii) Applicant filing We, [GSM GLOBE.COM INC] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter,as an entity producing coveredcommunications equipment. Yours sincerely, Name: Zubair Panjwani Date: 2024-08-28 Title and Company name: Director /GSM GLOBE.COM INC NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
GSM GLOBE.COM INC 2.911 (d)(7)USA Agent v1.5 Section 2.911(d)(7) USA Agent for Service of Process Company name: GSM GLOBE.COM INC Address: 10286 SW 22nd pl. Davie, Florida 33324, United States Product Name: MOBILE PHONE FCC ID: 2AEJARAYOGO Model(s): GO 2.911(d)(7) USA Designated Agent for Service of Process We, [GSM GLOBE.COM INC] (“the applicant”) designate [GSM GLOBE.COM INC] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent:We acknowledgeour consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledgeour acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either we the grantee have permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation:We acknowledgeourobligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email addressfor no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: GSM GLOBE.COM INC USA Address: 10286 SW 22nd pl. Davie, Florida 33324, United States FRN Number: 0024494924 Contact Name: Zubair Panjwani Telephone No: 7862476086 Email: [email protected] Applicant Company name: GSM GLOBE.COM INC Address: 10286 SW 22nd pl. Davie, Florida 33324, United States Grantee FRN Number: 0024494924 FCC Grantee Code: 2AEJA Contact Name:Zubair Panjwani Telephone No: 7862476086 Email: [email protected] Signature: Title: Director Signature: Title: Director Date:2024-08-28 Date:2024-08-28 GSM GLOBE.COM INC 2.911 (d)(7)USA Agent v1.5 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
GSM GLOBE.COM INC 10286 SW 22nd pl. Davie, Florida 33324, United States Agent Authorization Compa ny: GSM GLOBE.COM INC Address: 10286 SW 22nd pl. Davie, Florida 33324, United States Product Name: MOBILE PHONE Model Number(s): GO Product Description: MOBILE PHONE We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2024-08-28 Name: Zubair Panjwani Title: Director Company: GSM GLOBE.COM INC
GSM GLOBE.COM INC Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2024-08-28 Subject; Request for Long Term Confidentiality FCC ID: 2AEJARAYOGO To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Zubair Panjwani Title: Director
Page 1 of 4 Appendix C: Photographs of EUT Product: MOBILE PHONE Model: Go External Photos Page 2 of 4 Page 3 of 4 Page 4 of 4
Page 1 of 5 Appendix C: Photographs of EUT Product: MOBILE PHONE Model: Go Internal Photos Page 2 of 5 GSM Antenna Page 3 of 5 BT Antenna Page 4 of 5 Page 5 of 5
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com SAR TEST REPORT FCC ID. ............................ : 2AEJARAYOGO Test Report No. ............... : TCT240812E030 Date of issue ................... : Aug. 27, 2024 Testing laboratory .......... : SHENZHEN TONGCE TESTING LAB Testing location/ address: 2101 & 2201, Zhenchang Factory Renshan Industrial Zone, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, 518103, People's Republic of China Applicant's name ............ : GSM GLOBE.COM INC Address ........................... : 10286 SW 22nd pl. Davie, Florida, 33324 Manufacturer's name ... : GSM GLOBE.COM INC Address ........................... : 10286 SW 22nd pl. Davie, Florida, 33324 Test item description ..... : MOBILE PHONE Trade Mark ...................... : RAYO MOVIL Model/Type reference..... : Go SAR Max. Values..............: 0.51 W/Kg (1g) for head; 0.72 W/Kg (1g) for Body-worn Simultaneous Reported SAR..................................: 0.58 W/Kg (1g) for head; 0.83 W/Kg (1g) for Body-worn Date of receipt of test item ......................................... : Aug. 12, 2024 Date (s) of performance of test ................................... : Aug. 12, 2024 - Aug. 27, 2024 Tested by (+signature) ... : Una LI Check by (+signature) .... : Beryl Zhao Approved by (+signature): Tomsin General disclaimer: This report shall not be reproduced except in full, without the written approval of SHENZHEN TONGCE TESTING LAB. This document may be altered or revised by SHENZHEN TONGCE TESTING LAB personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT240812E030 Page 2 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TABLE OF CONTENTS 1. General Product Information ....................................................................................... 4 1.1. EUT description ..................................................................................................... 4 1.2. Model(s) list ............................................................................................................ 4 2. Test standard ................................................................................................................ 5 3. Facilities and Accreditations ....................................................................................... 5 3.1. Facilities ................................................................................................................. 5 3.2. Location ................................................................................................................. 5 3.3. Environment Condition: ........................................................................................ 5 4. Test Result Summary ................................................................................................... 6 5. RF Exposure Limit ........................................................................................................ 7 6. SAR Measurement System Configuration .................................................................. 8 6.1. SAR Measurement Set-up ..................................................................................... 8 6.2. E-field Probe .......................................................................................................... 9 6.3. Phantom ................................................................................................................. 9 6.4. Device Holder ....................................................................................................... 10 6.5. Data Storage and Evaluation .............................................................................. 11 6.6. Position of the wireless device in relation to the phantom.............................. 12 6.7. Tissue Dielectric Parameters.............................................................................. 15 6.8. Tissue-equivalent Liquid Properties .................................................................. 16 6.9. System Check ...................................................................................................... 17 7. Measurement Procedure ............................................................................................ 18 8. Conducted Output Power .......................................................................................... 21 9. Exposure Position Consideration ............................................................................. 23 9.1. EUT Antenna Location ........................................................................................ 23 9.2. Test Position Consideration ............................................................................... 23 10. SAR Test Results Summary ...................................................................................... 24 10.1.Head 1g SAR Data .............................................................................................. 24 10.2.Body-Worn 1g SAR Data .................................................................................... 25 10.3.Simultaneous Transmission Conclusion.......................................................... 26 10.4.SAR Simultaneous Transmission Analysis ...................................................... 27 10.5.Measurement Uncertainty (450MHz-3GHz) ....................................................... 28 10.6.Test Equipment List ........................................................................................... 30 11. System Check Results ............................................................................................... 31 12. SAR Test Data ............................................................................................................. 37 Report No.: TCT240812E030 Page 3 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-…
Text truncated - open the document above for the full version.
Report No.: TCT240812E030 Page 77 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 78 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 79 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 80 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 81 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 82 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 83 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 84 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 85 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 86 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com SID1900 Report No.: TCT240812E030 Page 87 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 88 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 89 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 90 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 91 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 92 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 93 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 94 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 95 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 96 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 97 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com SID2450 Report No.: TCT240812E030 Page 98 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 99 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 100 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 101 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 102 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 103 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 104 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 105 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 106 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 107 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E030 Page 108 of 109 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Appendix E: SAR SYSTEM VALIDATION Per FCC KDB 865664 D02v01, SAR system validation status should be documented to confirm measurement accuracy. The SAR systems (including SAR probes, system components and software versions) used for this device were validated against its performance specifications prior to the SAR measurements. Reference dipoles were used with the required tissue- equivalent media for system validation, according to the procedures outlined in FCC KDB 865664 D01 v01 and IEEE 1528-2013. Since SAR probe calibrations are frequency dependent, each probe calibration point was validated at a frequency within the valid frequency range of the probe calibration point, using the system that normally operates with the probe for routine SAR measurements and according to the required tissue-equivalent media. A tabulated summary of the system validation status including the validation date(s), measurement frequencies, SAR probes and tissue dielectric parameters has been included. SAR System Validation Summary Date Freq. [MHz] Probe S/N Tissu e type COND. PERM. COND. PERM. CW Validation Mod. Validation (σ) (εr) sensitivity Probe linearity Probe isotropy Mod. type Duty factor Peak to average power ratio 08/16/2024 835 SN 25/22 EPGO 375 Head 42.3 0.89 PASS PASS PASS GMSK PASS N/A 08/16/2024 1900 SN 25/22 EPGO 375 Head 40.31 1.38 PASS PASS PASS GMSK PASS N/A 08/16/2024 2450 SN 25/22 EPGO 375 Head 38.99 1.88 PASS PASS PASS OFDM PASS N/A NOTE: While the probes have been calibrated for both a CW and modulated signals, all measurements were performed using communication systems calibrated for CW signals only. Modulations in the table above represent test configurations for which the measurement system has been validated per FCC KDB Publication 865664 D01v01 for scenarios when CW probe calibrations are used with other signal types. SAR systems were valid…
Text truncated - open the document above for the full version.
Company name:Tianyutong Electronic Technology Co., Ltd Company address:212 Tairan Industrial and Trade Park, Futian District, Shenzhen City, Guangdong Province Model:X11-8322 2.4G BT ANT GAIN
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TEST REPORT FCC ID. ............................ : 2AEJARAYOGO Test Report No. ............... : TCT240812E028 Date of issue ................... : Aug. 27, 2024 Testing laboratory .......... : SHENZHEN TONGCE TESTING LAB Testing location/ address: 2101 & 2201, Zhenchang Factory Renshan Industrial Zone, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, 518103, People's Republic of China Applicant's name ............ : GSM GLOBE.COM INC Address ........................... : 10286 SW 22nd pl. Davie, Florida 33324, United States Manufacturer's name ..... : GSM GLOBE.COM INC Address ........................... : 10286 SW 22nd pl. Davie, Florida 33324, United States Standard(s) ..................... : FCC CFR Title 47 Part 15 Subpart C Section 15.247 FCC KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10:2013 Product Name ................. : MOBILE PHONE Trade Mark ...................... : RAYO MOVIL Model/Type reference..... : Go Rating(s).......................... : Adapter Information: Input: AC 100-240V, 50/60Hz,0.12A Output: DC 5.0V, 500mA Rechargeable Li-ion Battery DC 3.7V Date of receipt of test item ......................................... : Aug. 12, 2024 Date (s) of performance of test ................................... : Aug. 12, 2024 ~ Aug. 27, 2024 Tested by (+signature) ... : Aaron MO Check by (+signature) .... : Beryl ZHAO Approved by (+signature): Tomsin General disclaimer: This report shall not be reproduced except in full, without the written approval of SHENZHEN TONGCE TESTING LAB. This document may be altered or revised by SHENZHEN TONGCE TESTING LAB personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT240812E028 Page 2 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Table of Contents 1. General Product Information .................................................................. 3 1.1. EUT description ..................................................................................................... 3 1.2. Model(s) list ............................................................................................................ 3 1.3. Operation Frequency ............................................................................................ 4 2. Test Result Summary .............................................................................. 5 3. General Information ................................................................................. 6 3.1. Test environment and mode ................................................................................. 6 3.2. Description of Support Units ................................................................................ 7 4. Facilities and Accreditations .................................................................. 8 4.1. Facilities ................................................................................................................. 8 4.2. Location ................................................................................................................. 8 4.3. Measurement Uncertainty ..................................................................................... 8 5. Test Results and Measurement Data ..................................................... 9 5.1. Antenna requirement ............................................................................................ 9 5.2. Conducted Emission ........................................................................................... 10 5.3. Conducted Output Power ................................................................................... 14 5.4. 20dB Occupy Bandwidth .................................................................................... 15 5.5. Carrier Frequencies Separation ......................................................................... 16 5.6. Hopping Channel Number .................................................................................. 17 5.7. Dwell Time ............................................................................................................ 18 5.8. Pseudorandom Frequency Hopping Sequence ................................................ 19 5.9. Conducted Band Edge Measurement ................................................................ 20 5.10.Conducted Spurious Emission Measurement .................................................. 21 5.11.Radiated Spurious Emission Measurement ..................................................... 22 Appendix A: Test Result of Conducted Test Appendix B: Photographs of Test Setup Appendix C: Photographs of EUT Report No.: TCT240812E028 Page 3 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 1. General Product Information 1.1. EUT description Product Name ....................... : MOBILE PHONE Model/Type reference........... : Go Sample Number....................: TCT240812E028-0101 Bluetooth Version ................ : V3.0 Operation Frequency ........... : 2402MHz~2480MHz Transfer Rate ........................ : 1/2/3 Mbits/s Number of Channel .............. : 79 Modulation Type ................... : GFSK, π/4-DQPSK, 8DPSK Modulation Technology ....... : FHSS Antenna Type ........................ : PIFI Antenna Antenna Gain ........................ : 1.59dBi Rating(s)................................ : Adapter Information: Input: AC 100-240V, 50/60Hz,0.12A Output: DC 5.0V, 500mA Rechargeable Li-ion Battery DC 3.7V Note: The antenna gain listed in this report is provided by applicant, and the test laboratory is not responsible for this parameter. 1.2. Model(s) list None. Report No.: TCT240812E028 Page 4 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 1.3. Operation Frequency Channel Frequency Chann…
Text truncated - open the document above for the full version.
Report No.: TCT240812E028 Page 88 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Appendix B: Photographs of Test Setup Product: MOBILE PHONE Model: Go Radiated Emission Report No.: TCT240812E028 Page 89 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Conducted Emission Report No.: TCT240812E028 Page 90 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Appendix C: Photographs of EUT Product: MOBILE PHONE Model: Go External Photos Report No.: TCT240812E028 Page 91 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E028 Page 92 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E028 Page 93 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E028 Page 94 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Product: MOBILE PHONE Model: Go Internal Photos Report No.: TCT240812E028 Page 95 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E028 Page 96 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E028 Page 97 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT240812E028 Page 98 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com *****END OF REPORT***** Report No.: TCT240812E028 Page 99 of 99 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Page 1 of 2 Appendix B: Photographs of Test Setup Product: MOBILE PHONE Model: Go Radiated Emission Page 2 of 2 Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 8.60 mW |

Mobile Phone
Equipment Class
DTS - Digital Transmission System
MOBILE PHONE
Equipment Class
DTS - Digital Transmission System
Mobile Phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
2G Feature phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
MOBILE PHONE
Equipment Class
PCE - PCS Licensed Transmitter held to ear