FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. FRTEK CO., LTD./
  3. 2AFEG-R5GAO38ADU

2AFEG-R5GAO38ADUPrimAer DU28

FRTEK CO., LTD.
PrimAer DU28 - FCC ID 2AFEG-R5GAO38ADU - FRTEK CO., LTD.
Click to zoom

Application Details

Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Date of Grant
Nov 29, 2020
Application Purpose
Original Equipment
Date of Application
Nov 17, 2020
Equipment Note
PrimAer DU28
Frequency Range
27500.00000000 - 28350.00000000
Company
FRTEK CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PRIVATE AND CONFIDENTIAL ยฉ 2020 FRTEK CO., LTD. 1 PrimAer 28 Operating Manual PrimAer 28GHz Operating Manual Document Reference Company: Fiber Radio Technologies Version: Ver 0 Document Status: Release 1 Issue Date: 2020. 11. Department: R&D Group 1 Author Manager: Jun Sung, Park PRIVATE AND CONFIDENTIAL ยฉ 2020 FRTEK CO., LTD. 2 PrimAer 28GHz Operating Manual โ–ช Copyright The contents of this Manual are owned and copyrighted by FRTek Co., Ltd. This manual may not be reproduced, distributed, modified in any form without the written consent of FRTek Co., Ltd Unauthorized disclosure, distribution, copying or use of the information contained in this document in whole or in part without written permission is strictly prohibited. โ–ช Trademark The trademarks mentioned in this manual are registered trademarks of FRTek Please read this service manual before installation and operation. Use the system only in accordance with the contents and directions of this manual. ๏ƒ˜ The specification and information regarding the products in this manual are subject to change due to updates to system functionality or system revision changes without notice. For the latest revision of this manual or for technical inquiries, please contact below : Company Address : 181 Metro Drive, Suite 580, San Jose, CA 95110 Homepage : http://www.frtek.com Contact for technical inquires or troubleshooting. Telephone : 443-463-9994 or 510-390-1939 PRIVATE AND CONFIDENTIAL ยฉ 2020 FRTEK CO., LTD. 3 PrimAer 28GHz Operating Manual Revision History Version Issue Date Details of Revision Author Authorizing Manager V 0 Nov. 17th, 2020. Original Jun Sung, Park This manual is produced by R&D Group 1 Printed in FRTek. PRIVATE AND CONFIDENTIAL ยฉ 2020 FRTEK CO., LTD. 4 PrimAer 28GHz Operating Manual Contents Chapter 1 Safety & Certification Notice ................................................................................... 8 1.1 FCC Warning Statements ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 1.1.1 FCC Part 15.105 statement .......................................................................................................................... 9 1.1.2 FCC Part 15.21 statement ............................................................................................................................. 9 1.1.3 Health and Safety Warnings........................................................................................................................ 9 1.2 Certification Notice ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 Chapter 2 System Overview ....................................................................................................... 13 2.1 System Overview ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 14 2.1.1 Overview .............................................................................................................................................................14 2.1.2 PrimAer 28GHz Design Consideration .................................................................................................15 2.2 System Network Configuration ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 Chapter 3 System Configuration .............................................................................................. 17 3.1 DU Figure and Configuration ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 3.2 SU Figure and Configurationยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 19 3.3 Rectifier Details and Configuration ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 21 3.4 DU, SU, Rectifier Connecting ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 23 Chapter 4 System Specification ................................................................................................ 25 4.1 System Specification ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 26 4.1.1 Downlink Specification .................................................................................................................................26 4.1.2 Uplink Specification .......................................................................................................................................27 4.2 Instrumental Specification ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 27 4.2.1 Structure and Type .........................................................................................................................................27 4.2.2 Material and Components .........................................................................................................................27 4.3 Electrical Specification ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 28 4.4 Environmental Specification ..........................................................................................................................29 4.5 Antenna Specification ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 30 4.5.1 DU Antenna...โ€ฆ

Text truncated - open the document above for the full version.

Attestation Statements

FRTEK CO., LTD. 11-25, Simin-daero 327beon-gil, Dongan-gu, Anyang-Si, Gyeonggi-do 431-755 Korea (Republic Of) ___________________________________________________________________________ Date: Nov 13, 2020 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 Subject: Letter for Warning Label Message FCC ID: 2AFEG-R5GAO38ADU To Whom It May Concern: Warning label messages will be also shown in online and point-of-sale marketing materials and on outside packaging of device per KDB 935210 D02 Signal Boosters Certification v04r02 in Section IV clause (d). Sincerely Yours, SungKook Hong / General Manager

Cover Letter(s)

Date : Nov. 9, 2017 Rev : 2.3 HACS-F004 FCC Agent Authorization Letter HCT America LLC ([email protected]) 1726 Ringwood Avenue San Jose, CA 95131 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America LLC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America LLC FCC Agent Authorization Letter Date : Nov. 9, 2017 Rev : 2.3 HACS-F004 FCC Agent Authorization Letter HCT America LLC ([email protected]) 1726 Ringwood Avenue San Jose, CA 95131 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America LLC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America LLC REVISION TABLE Rev Description of Change Date Approved 1.0 Original Release(Obsolete) 06/14/2012 QM 2.0 Updated template(Obsolete) 10/01/2012 QM 2.1 Updated address(Obsolete) 01/10/2014 QM 2.2 Updated address 11/18/2016 QM 2.3 Fixed Typo โ€œAgentโ€ 11/09/2017 QM FRTEK CO., LTD 11-25, Simin-daero 327beon-gil, Dongan-gu, Anyang-Si, Gyeonggi-do 431-755 Korea (Republic Of) HACS-F004 FCC Agent Authorization Letter Rev : 2.3 Date: Nov 13, 2020 To : Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To whom it may concern: Subject : FCC Agent Authorization Letter for FCC ID: 2AFEG-R5GAO38ADU We, the undersigned, hereby authorize HCT CO., LTD. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by HCT CO., LTD. on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). We recognize that we are still responsible for the terms and conditions outlined in the HCT America Client Services Agreement. This authorization is valid until further written notice from the applicant. Sincerely, SungKook Hong / General Manager

Cover Letter(s)

Date : Nov. 09, 2017 Rev : 3.0 HACS-F003 FCC Confidentiality Request Letter HCT America LLC ([email protected]) 1726 Ringwood Avenue San Jose, CA 95131 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 1 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America LLC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America LLC FCC Confidentiality Request Letter Date : Nov. 09, 2017 Rev : 3.0 HACS-F003 FCC Confidentiality Request Letter HCT America LLC ([email protected]) 1726 Ringwood Avenue San Jose, CA 95131 TEL: +1.510.933.8848, Fax: +1.510.933.8849 Page 2 of 2 This document is electronically controlled. Hard copy documents are uncontrolled. Please check all hard copies against the controlled electronic copy to ensure validity. This document is the confidential property of HCT America LLC. It may not be forwarded or reproduced in whole or in part without written permissions from HCT America LLC REVISION TABLE Rev Description of Change Date Approved 1.0 Original Release(Obsolete) 06/14/2012 QM 2.0 Updated template(Obsolete) 10/01/2012 QM 2.1 Updated address(Obsolete) 01/10/2014 QM 2.2 Updated address 11/18/2016 QM 3.0 Updated LTC and STC Confidentiality table 11/09/2017 QM FRTEK CO., LTD 11-25, Simin-daero 327beon-gil, Dongan-gu, Anyang-Si, Gyeonggi-do 431-755 Korea (Republic Of) HACS-F003 FCC Confidentiality Request Letter Rev : 3.0 Date: Nov 13, 2020 To : Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD SUBJECT: Request for Confidentiality for FCC ID: 2AFEG-R5GAO38ADU We hereby request confidential treatment of the information accompanying this application as outlined below: LONG-TERM AND SHORT-TERM CONFIDENTIAL LIST LONG-TERM CONFIDENTIAL Exhibit Description 1 Block Diagram 2 Operational Description 3 Parts List & Tune up procedure 4 Schematics SHORT-TERM CONFIDENTIAL (180 DAYS) 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 Userโ€™s Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, SungKook Hong / General Manager

External Photos

FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ‘ of 7 EXTERNAL PHOTOGRAPHS FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ’ of 7 โ–  EXTERNAL PHOTO(LEFT) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ“ of 7 โ–  EXTERNAL PHOTO(RIGHT) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ” of 7 โ–  EXTERNAL PHOTO(Bottom) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ• of 7 โ–  EXTERNAL PHOTO(Top) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ– of 7 โ–  EXTERNAL PHOTO(Front) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ— of 7 โ–  EXTERNAL PHOTO(Rear)

ID Label/Location Info

1 PRIVATE AND CONFIDENTIAL ยฉ 2020 FRTEK CO., LTD. 1. DU label & location FCC ID FCC Signal Booster Warning statements

Internal Photos

FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ‘ of 14 INTERNAL PHOTOGRAPHS FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ’ of 14 โ–  INTERNAL PHOTO(DAOM_BOTTOM_BD_BOTTOM) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ“ of 14 โ–  INTERNAL PHOTO(DAOM_BOTTOM_BD_TOP) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ” of 14 โ–  INTERNAL PHOTO(DAOM_TOP_BD_BOTTOM) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ• of 14 โ–  INTERNAL PHOTO(DAOM_TOP_BD_TOP) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ– of 14 โ–  INTERNAL PHOTO(DIFM_BOTTOM) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ— of 14 โ–  INTERNAL PHOTO(DIFM_TOP) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ˜ of 14 โ–  INTERNAL PHOTO(EMS_BD_BOTTOM) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ™ of 14 โ–  INTERNAL PHOTO(EMS_BD_TOP) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ‘๏ผ of 14 โ–  INTERNAL PHOTO(Modem_IF_BD_BOTTOM) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ‘๏ผ‘ of 14 โ–  INTERNAL PHOTO(Modem_IF_BD_TOP) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ‘๏ผ’ of 14 โ–  INTERNAL PHOTO(MVBX-285_Donor_BOTTOM) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ‘๏ผ“ of 14 โ–  INTERNAL PHOTO(MVBX-285_Donor_TOP) FCC ID: 2AFEG-R5GAO38ADU HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page ๏ผ‘๏ผ” of 14 โ–  INTERNAL PHOTO (Enclosure and antenna location)

RF Exposure Info

TEST REPORT FCC MPE Test for FR-R5GAO38ADU Certification APPLICANT FRTEK CO., LTD. REPORT NO. HCT-RF-2011-FC019 DATE OF ISSUE November 17, 2020 Tested by Kyung Soo Kang Technical Manager Jong Seok Lee HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383 KOREA Tel. +82 31 634 6300 F ax. +82 31 645 6401 F-TP22-03 (Rev. 03) Page 2 of 6 HCT Co., Ltd. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383 KOREA Tel. +82 31 634 6300 Fax. +82 31 645 6401 TEST REPORT FCC MPE Test for FR-R5GAO38ADU REPORT NO. HCT-RF-2011-FC019 DATE OF ISSUE November 17, 2020 Additional Model - Applicant FRTEK CO., LTD. 11-25, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, Re public of Korea FCC ID 2AFEG-R5GAO38ADU Product Name PrimAer DU28 Model Name FR-R5GAO38ADU The result shown in this test report refer only to the sample(s) tested unless otherwise stated. This test results were applied only to the test methods required by the standard. F-TP22-03 (Rev. 03) Page 3 of 6 Report No. HCT-RF-2011-FC019 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 November 17, 2020 Initial Release The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. * The report shall not be reproduced except in full(only partly) without approval of the laboratory. F-TP22-03 (Rev. 03) Page 4 of 6 Report No. HCT-RF-2011-FC019 RF Exposure Statement 1. Limit - According to ยง 1.1310 RF exposure is calculated. Table 1 หŠ Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 300-1,500 f/300 6 1,500-100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *100 30 1.34-30 824/f 2.19/f *180/f 2 30 30-300 27.5 0.073 0.2 30 300-1,500 f/1500 30 1,500-100,000 1.0 30 f = frequency in MHz, * = Plane-wave equivalent power density F-TP22-03 (Rev. 03) Page 5 of 6 Report No. HCT-RF-2011-FC019 2. Maximum Permissible Exposure Prediction Prediction of MPE limit at a given distance S=PG/4ฯ€R เฌถ S = Power density P = Power input to antenna G = Power gain to the antenna in the direction of interest relative to an isotropic radiator R = Distance to the center of radiation of the antenna F-TP22-03 (Rev. 03) Page 6 of 6 Report No. HCT-RF-2011-FC019 3. Results [SISO] EIRP[Radiated Power] 40.00 dBm EIRP[Radiated Power] 10000.00 mW Prediction distance 40.00 cm Prediction frequency 27 500 ~ 28 350 MHz Power density at prediction frequency (S) 0.4974 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 1.000 mW/cm 2 [MIMO] EIRP[Radiated Power] 43.00 dBm EIRP[Radiated Power] 19952.62 mW Prediction distance 40.00 cm Prediction frequency 27 500 ~ 28 350 MHz Power density at prediction frequency (S) 0.9924 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 1.000 mW/cm 2

Test Report

TEST REPORT FCC Test for FR-R5GAO38ADU Certification APPLICANT FRTEK CO., LTD. REPORT NO. HCT-RF-2011-FC018-R1 DATE OF ISSUE November 27, 2020 Tested by Kyung Soo Kang Technical Manager Jong Seok Lee HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383 KOREA Tel. +82 31 634 6300 F ax. +82 31 645 6401 F-TP22-03 (Rev. 03) Page 2 of 80 HCT Co., Ltd. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383 KOREA Tel. +82 31 634 6300 Fax. +82 31 645 6401 TEST REPORT FCC Test for FR- R5GAO38ADU REPORT NO. HCT-RF-2011-FC018-R1 DATE OF ISSUE November 27, 2020 Additional Model - Applicant FRTEK CO., LTD. 11-25, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, Re public of Korea FCC ID 2AFEG-R5GAO38ADU Product Name PrimAer DU28 Model Name FR-R5GAO38ADU Date of Test September 07, 2020 ~ November 26, 2020 Test Standard Used CFR 47 Part 2, Part 30 The result shown in this test report refer only to the sample(s) tested unless otherwise stated. This test results were applied only to the test methods required by the standard. F-TP22-03 (Rev. 03) Page 3 of 80 Report No. HCT-RF-2011-FC018-R1 REVISION HISTORY The revision history for this test report is shown in table. Revision No. Date of Issue Description 0 November 17, 2020 Initial Release 1 November 27, 2020 - Revised the หŽChannel Bandwidthsห on section 1.2. - Revised test results and plots on section 5.6. The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules under normal use and maintenance. * The report shall not be reproduced except in full(only partly) without approval of the laboratory. F-TP22-03 (Rev. 03) Page 4 of 80 Report No. HCT-RF-2011-FC018-R1 CONTENTS 1. GENERAL INFORMATION 5 1.1. APPLICANT INFORMATION 5 1.2. PRODUCT INFORMATION 5 1.3. TEST INFORMATION 6 2. FACILITIES AND ACCREDITATIONS 7 2.1. FACILITIES 7 2.2. EQUIPMENT 7 3. TEST SPECIFICATIONS 8 3.1. STANDARDS 8 3.2. ADDITIONAL DESCRIPTIONS ABOUT TEST 9 3.3. MAXIMUM MEASUREMENTUNCERTAINTY 11 3.4. STANDARDS ENVIRONMENTAL TEST CONDITIONS 11 3.5. TEST DIAGRAMS 12 4. TEST EQUIPMENTS 13 5. TEST RESULT 14 5.1. AGC THRESHOLD 14 5.2. OUT-OF-BAND REJECTION 16 5.3. OCCUPIED BANDWIDTH / INPUT-VERSUS-OUTPUT SIGNAL COMPARISON 18 5.4. EIRP DENSITY 28 5.5. EQUIVALENT ISOTROPIC RADIATED POWER / MEAN OUTPUT POWER AND AMPLIFIER/BOOSTER GAIN 34 5.6. BAND EDGE / OUT-OF-BAND/OUT-OF-BLOCK EMISSIONS AND SPURIOUS EMISSIONS 41 5.7. RADIATED SPURIOUS EMISSIONS 58 6. MIXER VERIFICATION CERTIFICATE & CHECK 71 7. Annex B_EUT AND TEST SETUP PHOTO 80 F-TP22-03 (Rev. 03) Page 5 of 80 Report No. HCT-RF-2011-FC018-R1 1. GENERAL INFORMATION 1.1. APPLICANT INFORMATION Company Name FRTEK CO., LTD. Company Address 1001, Doosan Venture Digm, 415, Heungandaero, Dongan-Gu, Anyang-Si, Gyenggi-do, 431-755 Korea 1.2. PRODUCT INFORMATION EUT Type PrimAer DU28 Input Rating Power Port -53.3 V, 1A Power Supply AC (100 ~ 240) V DC -53.3 V Frequency Range 27 500 MHz ~ 28 350 MHz Output Power Mode EIRP Total (2 path) (dBm) (dBm) 1CC 38.0 41.0 8CC 38.0 41.0 Max EIRP Density Mode [W] 1CC 14.125 8CC 2.506 Channel Bandwidths 1CC: 100 MHz 8CC: 800 MHz F-TP22-03 (Rev. 03) Page 6 of 80 Report No. HCT-RF-2011-FC018-R1 Antenna Specification (Antenna Array) A high-performance 32-element (8x4) integrated antenna array is included in the SOB Maximum Gain: 18 dBi Antenna pitch: 5.2 mm Antenna Size: Length: 8 x 5.2 mm = 41.6 mm Width: 4 x 5.2 mm = 20.8 mm Lattice: Rectangular Type: Patch 1.3. TEST INFORMATION FCC Rule Parts CFR 47 Part 2, Part 30 Measurement standards KDB 935210 D05 v01r04, ANSI C63.26-2015, KDB 971168 D01 v03r01, KDB 662911 D01 v02r01, KDB 662911 D02 v01, KDB 842590 D01 v01r01 Place of Test HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA F-TP22-03 (Rev. 03) Page 7 of 80 Report No. HCT-RF-2011-FC018-R1 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA. The site is constructed in conformance with the requirements of ANSI C63.4 (Version: 2014) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated April 02, 2018 (Registration Number: KR0032). 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of Linearly polarized antennas: tuned dipole, bi- conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to perform radiated measurements. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, ห‘Radio Interference Measuring Apparatus and Measurement Methods.ห’ F-TP22-03 (Rev. 03) Page 8 of 80 Report No. HCT-RF-2011-FC018-R1 3. TEST SPECIFICATIONS 3.1. STANDARDS The following tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC Part 2, Part 30 Description Reference Results AGC threshold KDB 935210 D05 v01r04 3.2 Compliant Out-of-band rejection KDB 935210 D05 v01r04 3.3 Compliant Occupied Bandwidth / Input-versus-output signal comparison ยง2.1049 Compliant EIRP Density ยง30.202 Compliant Equivalent Isotropic Radiated Power / Mean output power and amplifier/booster gain ยง2.1046 Compliant Band Edge ยง2.1051, ยง30.203 Compliant Radiated Spurious Emissions ยง2.1051, ยง30.203 Complianโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

SungKook Hong(General Manager)
[email protected]+82-31-478-2114Fax: +82-31-478-2116

Test Firm

HCT Co., Ltd.Lee Yoon-Jung
[email protected]82-31-645-6432Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
2327.50 GHz - 28.35 GHz2.506 WG7DAmp
Confidentiality
Long Term
Grant Notes
Output power listed is EIRP. This device is an Industrial Signal Booster that supports operation in the 5G NR band n261 and supports both SISO and 2x2 MIMO operation. Professional installation required. The antennas for this product must not exceed 18 dBi in gain and must be installed and operated so as to provide a separation distance of at least 40 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from FRTEK CO., LTD.

PrimAer SU_C28 - FCC ID 2AFEG-R5GAO33ASUC - FRTEK CO., LTD.
2AFEG-R5GAO33ASUC

PrimAer SU_C28

Nov 29, 2020

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
MODAS(Multi-Operator DAS) - FCC ID 2AFEGFRWL46ROU70 - FRTEK CO., LTD.
2AFEGFRWL46ROU70

MODAS(Multi-Operator DAS)

Nov 16, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
MODAS(Multi-Operator DAS) - FCC ID 2AFEGFRWL46ROU80 - FRTEK CO., LTD.
2AFEGFRWL46ROU80

MODAS(Multi-Operator DAS)

Nov 16, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
MODAS (Multi-Operator DAS) - FCC ID 2AFEGFRWL40ROU70 - FRTEK CO., LTD.
2AFEGFRWL40ROU70

MODAS (Multi-Operator DAS)

Nov 11, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
MODAS(Multi-Operator DAS) - FCC ID 2AFEGFRWL46ROU21 - FRTEK CO., LTD.
2AFEGFRWL46ROU21

MODAS(Multi-Operator DAS)

Nov 02, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)