Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Date of Grant
Nov 11, 2015
Application Purpose
Original Equipment
Date of Application
Nov 09, 2015
Equipment Note
MODAS (Multi-Operator DAS)
Frequency Range
746.00000000 - 757.00000000
Company
FRTEK CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Sierra User Manual © FRTek Co. Ltd 2015 1 Confidential: Any reproduction or distribution without the express written consent of FRTek is strictly prohibited P/N: FR-RMDL10U @ revision 1.0 Sierra ROU10W Multi-Operator/Multi-Band DAS User Manual VER 1.0 Sierra ROU 10W User Manual © FRTek Co. Ltd 2015 2 Confidential: Any reproduction or distribution without the express written consent of FRTek Co. Ltd or FRTek US LLC is strictly prohibited Table of Contents 1. Overview...............................................................................................................7 1.1 Product Overview....................................................................................7 1.2 System Features.......................................................................................7 2. System Network Configuration..........................................................................9 3. System Architecture.............................................................................................13 3.1 Architecture..............................................................................................13 4. System Specifications...........................................................................................23 4.1 System Specification 4.2 Environmental conditions 5. Operational Program 5.1 Overview 5.2 Screen configuration 5.3 ROUStatus Verification and Control 5.4 Reset 5.5 Set-up T ime Advance 5.6 Download 5.7 Debug 6. Main Technical Details 6.1 Main Technical details 6.2 Technical Details 7. Alarm and Troubleshooting Sierra ROU 10W User Manual © FRTek Co. Ltd 2015 3 Confidential: Any reproduction or distribution without the express written consent of FRTek Co. Ltd or FRTek US LLC is strictly prohibited FCC WARNING This equipment generates or uses radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made. INFORMATION TO THE USER Part 27.5 Booster Warning Label WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. Specification or recommendation about Antennas is not available or not mention in this manual. As per default antennas, cables or coupling devices, contact www.frtek.net for further information. The head end unit must always be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station. Antennas must be installed in accordance with FCC 27.50. With 17dBi gain antennas the height of the antenna above average terrain (HAAT) must not exceed 915m. For difference gain antennas refer to the relevant rules. Sierra ROU 10W User Manual © FRTek Co. Ltd 2015 4 Confidential: Any reproduction or distribution without the express written consent of FRTek Co. Ltd or FRTek US LLC is strictly prohibited 1. Overview 1.1 SIERRA Overview This manual is created for operators who is using or will use Sierra DAS system to give an information and an instructions how to figure out the system. Operator shall be acknowledged, experienced and properly educated about the overalls of repeater system and the experience of the installation & maintenance of DAS system. 1.2 Use of recommendation and warning Booster Warning Label WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. Warning Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor-only restrictions is prohibited. Caution This symbol indicates cautions which operators shall be careful while installing and managing systems 1.3 System Features Sierra is an in-building/outdoor DAS system and provides 4 bands of service; 700MHz (LTE, 27MHz), 850MHz (WCDMA, LTE 32MHz), 1.9GHz (WCDMA, LTE 65MHz), 2.1GHz (WCDMA, LTE, 45MHz) at the same time. The system is scalable to extend additional 2 bands services - 2.3GHz and 2.5GHz frequencies. Sierra system is configured and features: A. ROU : Remote Optic Unit - Type 1. ROU 10W : 700MHz SISO, 700MHz MIMO, 850MHz SISO, 1.9GHz SISO, 2.1GHz SISO, 2.1GHz MIMO Sierra ROU 10W User Manual © FRTek Co. Ltd 2015 5 Confidential: Any reproduction or distribution without the express written consent of FRTek Co. Ltd or FRTek US LLC is strictly prohibited 2. SROU 10W : 2.3GHz SISO, 2.3GHz MIMO, 2.5GHz SISO, 2.5GHz MIMO(Future ordering option) - Conversion and amplification of digital optical signal into an RF signal (Downlink) - Converting the RF signal into a digital optical signal (Uplink) - Optic interfaces with MHU - Node Isolation : Bypass to avoid impact on service of lower nodes in case of failure of upper nodes or power off condition - System Delay Equalizer (110us) 1.4 System Port Configuration - Unauthorized cables and devices would give damages to the system. Approved devices and cables are recommended to use. A. ROU 10W Port Configuration Port Type Description Port Location Input Power Single AC Power Input Bottom side Antenna 6 ports (700MHz SISO, 700MHz MIMO, 850MHz SISO, 1.9GHz SISO, 2.1GHz SISO, 2.1GHz MIMO) Optic Cable Optic Cable inputs – 3 ports (TR, IR, EX) BATTERY Pb BATT, Li-BATT inputs – 2 ports External Fan External Fan Power Input – Single port Power Ground Single port Telecom Ground 2 ports 1 for each Left/Right side Sierra ROU 10W U…

Text truncated - open the document above for the full version.

Cover Letter(s)

FRTEK CO., LTD. 1001, Doosan Venture Digm, 415, Heungandaero, Dongan-Gu, Anyang-Si, Gyeonggi-do, 431-755 Korea Tel : +82-31-478-2114 Fax : +82-31-478-2116 ____________________________________________________________________________ Date: Sept. 4, 2015 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 Subject: Letter for Warning Label Message FCC ID: 2AFEGFRWL40ROU70, 2AFEGFRWL40ROU80, 2AFEGFRWL40ROU19, 2AFEGFRWL40ROU21, 2AFEGFRWL46ROU70, 2AFEGFRWL46ROU80, 2AFEGFRWL46ROU19, 2AFEGFRWL46ROU21 To Whom It May Concern: Warning label messages will be also shown in online and point-of-sale marketing materials and on outside packaging of device per KDB 935210 D02 in Section IV clause (d). Best Regards Signature Donald Kim/ General Manager FRTeK CO.,LTD.

External Photos

FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 1 of 14 EXTERNAL PHOTOGRAPHS FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 2 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 3 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 4 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 5 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 6 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 7 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 8 of 14 System FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 9 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 10 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 11 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 12 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 13 of 14 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 14 of 14

ID Label/Location Info

5 4. FCC 10W – 70 LABEL / Location < FRWL40ROU70 라벨> < WARNING 라벨> < FRWL40ROU70 Label Location> < WARNING Label Location > < WARNING 라벨>

Internal Photos

FCC ID : 2AFEGFRWL40ROU70 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si , Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/ 9 INTERNAL PHOTOGRAPHS FCC ID : 2AFEGFRWL40ROU70 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si , Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/ 9 1. RADA 2.1G FCC ID : 2AFEGFRWL40ROU70 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si , Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/ 9 2. RRFU 2.1G FCC ID : 2AFEGFRWL40ROU70 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si , Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/ 9 FCC ID : 2AFEGFRWL40ROU70 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si , Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/ 9 FCC ID : 2AFEGFRWL40ROU70 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si , Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/ 9 FCC ID : 2AFEGFRWL40ROU70 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si , Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/ 9 3. HPA 2.1G FCC ID : 2AFEGFRWL40ROU70 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si , Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 8/ 9 4. RFEU 2.1G FCC ID : 2AFEGFRWL40ROU70 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si , Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 9/ 9

Test Report

Report No.: HCT-R -1509-F040-1 Model:FRWL40ROU70 Page 2 of 54 F-TP22-0 3 (Rev.00) FCC ID: 2AFEGFRWL40ROU70 2 / 54 Version TEST REPORT NO. DATE DESCRIPTION HCT-R-1509-F040 September 16, 2015 - First Approval Report HCT-R-1509-F040-1 October 15, 2015 - Added the measurement uncertainty - Revised test plots : 9 kHz ~ 30 MHz spurious emission. Report No.: HCT-R -1509-F040-1 Model:FRWL40ROU70 Page 3 of 54 F-TP22-0 3 (Rev.00) FCC ID: 2AFEGFRWL40ROU70 3 / 54 Table of Contents 1. CLIENT INFORMATION ................................................................................................................................ 4 2. FACILITIES AND ACCREDITATIONS .......................................................................................................... 5 2.1. FACILITIES ......................................................................................................................................... 5 2.2. EQUIPMENT ....................................................................................................................................... 5 3. TEST SPECIFICATIONS ............................................................................................................................... 6 3.1. STANDARDS ...................................................................................................................................... 6 3.2. MODE OF OPERATION DURING THE TEST .................................................................................... 6 3.3. Maximum measurement uncertainty ............................................................................................... 7 4. STANDARDS ENVIRONMENTAL TEST CONDITIONS .............................................................................. 8 5. TEST EQUIPMENT ....................................................................................................................................... 9 6. RF OUTPUT POWER.................................................................................................................................. 10 7. OCCUPIED BANDWIDTH........................................................................................................................... 20 8. OUT OF BAND REJECTION ...................................................................................................................... 30 9. SPURIOUS AND HARMONIC EMISSION AT ANTENNA TERMINAL ...................................................... 32 10. RADIATED SPURIOUS EMISSIONS ....................................................................................................... 50 11. FREQUENCY STABILITY OVER TEMPERATURE AND VOLTAGE VARIATIONS ................................ 53 Report No.: HCT-R -1509-F040-1 Model:FRWL40ROU70 Page 4 of 54 F-TP22-0 3 (Rev.00) FCC ID: 2AFEGFRWL40ROU70 4 / 54 1. CLIENT INFORMATION The EUT has been tested by request of Company FRTEK CO., LTD. 1001, Doosan Venture Digm, 415, Heungandaero, Dongan-Gu, Anyang-Si, Gyeonggi-do, 431-755 Korea FCC ID: 2AFEGFRWL40ROU70 EUT Type: MODAS(Multi-Operator DAS) FCC Model(s): FRWL40ROU70 Frequency Ranges: LTE 5 MHz : 728 MHz ~ 746 MHz LTE 10 MHz : 746 MHz ~ 757 MHz Conducted Output Power: 10 W (40 dBm) Antenna Gain(s): Manufacturer does not provide an antenna. Measurement standard(s): ANSI/TIA-603-C-2004, KDB 971168 D01 v02r02 KDB 935210 D02 v03, KDB 935210 D05 v01, KDB 662911 D01 v02r01 FCC Rule Part(s): CFR Title 47 Part 27 Place of Tests: HCT CO., LTD., 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, 17383, Rep. of KOREA (IC Recognition No. : 5944A-3) Report No.: HCT-R -1509-F040-1 Model:FRWL40ROU70 Page 5 of 54 F-TP22-0 3 (Rev.00) FCC ID: 2AFEGFRWL40ROU70 5 / 54 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA. The site is constructed in conformance with the requirements of ANSI C63.4. (Version :2003) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated July 07, 2015 (Registration Number: 90661). 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of Linearly polarized antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre- selectors and quasi-peak detectors are used to perform radiated measurements. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring Apparatus and Measurement Methods.” Report No.: HCT-R -1509-F040-1 Model:FRWL40ROU70 Page 6 of 54 F-TP22-0 3 (Rev.00) FCC ID: 2AFEGFRWL40ROU70 6 / 54 3. TEST SPECIFICATIONS 3.1. STANDARDS The following tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC Part 27. Description Reference Results RF Output Power §2.1046; §27.50 Compliant Occupied Bandwidth §2.1049 Compliant Out of Band Rejection KDB 935210 D02 v03 Compliant Spurious Emissions at Antenna Terminals §2.1051, §27.53 Compliant Radiated Spurious Emissions §2.1053, §27.53 Compliant Frequency Stability §2.1055, §27.54 Compliant Note 1 The device is available in combination with the same device. Therefore, calculated the MIMO test results to a single test result. MIMO Calculation methods. RF Output Power : KDB 662911 D01, section E)2)c) Out-of-Band and Spurious Emission : KDB 662911 D01, section E)3)a) (iii) 3. 2. MODE OF OPERATION DURING THE TEST The EUT was operated in a manner representative of the typical usage of the equipment. During all testing, system components were manipulated within the confines of typical usage to maximize each emission. The device does not supply antenna(s) with the system, so the dummy loads were connected to the RF…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 1 of 6 TEST SETUP PHOTOGRAPHS FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 2 of 6 ■ Conducted Test Setup Photo-1 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 3 of 6 ■ Conducted Test Setup Photo-2 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 4 of 6 ■ Conducted Test Setup Photo-3 FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 5 of 6 ■ Radiated front Test Setup Photo FCC ID: 2AFEGFRWL40ROU70 HCT CO., LTD 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, 17383, Rep. of KOREA TEL : + 82 31 645 6300 FAX : + 82 31 645 6401 www.hct.co.kr Page 6 of 6 ■ Radiated rear Test Setup Photo

Contact Information

Applicant

SungKook Hong(General Manager)
[email protected]+82-31-478-2114Fax: +82-31-478-2116

Test Firm

HCT Co., LTDSang Lee
[email protected]82-31-645-6420Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
227746 MHz - 757 MHz20.512 W8M96G7DAmp
Confidentiality
Long Term
Grant Notes
Output power is conducted. Device supports WCDMA &amp; LTE 5MHz/10MHz modulations. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data for SISO (single-input single-output) and MIMO (multiple-input multiple-output) booster system configurations. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances.

Other Applications from FRTEK CO., LTD.

PrimAer DU28 - FCC ID 2AFEG-R5GAO38ADU - FRTEK CO., LTD.
2AFEG-R5GAO38ADU

PrimAer DU28

Nov 29, 2020

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
PrimAer SU_C28 - FCC ID 2AFEG-R5GAO33ASUC - FRTEK CO., LTD.
2AFEG-R5GAO33ASUC

PrimAer SU_C28

Nov 29, 2020

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
MODAS(Multi-Operator DAS) - FCC ID 2AFEGFRWL46ROU70 - FRTEK CO., LTD.
2AFEGFRWL46ROU70

MODAS(Multi-Operator DAS)

Nov 16, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
MODAS(Multi-Operator DAS) - FCC ID 2AFEGFRWL46ROU80 - FRTEK CO., LTD.
2AFEGFRWL46ROU80

MODAS(Multi-Operator DAS)

Nov 16, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
MODAS(Multi-Operator DAS) - FCC ID 2AFEGFRWL46ROU21 - FRTEK CO., LTD.
2AFEGFRWL46ROU21

MODAS(Multi-Operator DAS)

Nov 02, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)