Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E3 Page 24 of 27 9 Photos of the EUT Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E3 Page 25 of 27 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E3 Page 26 of 27
Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E3 Page 27 of 27 END OF REPORT
Dongguan Dongdian Testing Service Co., Ltd Report No.:DDT-R21030115-2E7 Page 1 of 11 RF EXPOSURE REPORT FOR Issued By: Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808 Tel.: +86-0769-38826678, E-mail: [email protected], http://www.dgddt.com Applicant : Spigen Korea Co., Ltd. Address : 446, Bongeusa-ro, Gangnam-gu, Seoul, Rep. of Korea Equipment under Test : Spigen PowerArc ArcField TM Model No. : PF2004 Trade Mark : Spigen FCC ID : 2AFKNPF2004 Manufacturer : Spigen Korea Co., Ltd. Address : 446, Bongeusa-ro, Gangnam-gu, Seoul, Rep. of Korea ■Report No.: DDT-R21030115-2E7 ■Issued Date: Mar. 23, 2021 Dongguan Dongdian Testing Service Co., Ltd Report No.:DDT-R21030115-2E7 Page 2 of 11 Table of Contents Test report declares........................................................................................................3 1. General Information ...................................................................................................... 5 1.1. Description of equipment .............................................................................................. 5 1.2. Assistant equipment used for test ................................................................................. 5 1.3. Assess laboratory ......................................................................................................... 5 2. Equipment used during test .......................................................................................... 5 3. Method of Measurement ............................................................................................... 6 3.1. Applicable standard ...................................................................................................... 6 3.2. Block diagram of test setup .......................................................................................... 6 3.3. Test procedure .............................................................................................................. 6 3.4. Equipment approval considerations: ............................................................................. 7 3.5. E and H Field Strength ................................................................................................. 8 4. Test Setup Photo .......................................................................................................... 9 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E7 Page 3 of 11 Test Report Declare Assess Standard Used: FCC CFR 47 part1, 1.1307(b), 1.1310; KDB680106 DR03-44118 We Declare: The equipment described above is assessed by Dongguan Dongdian Testing Service Co., Ltd and in the configuration assessed the equipment complied with the standards specified above. The assessed results are contained in this report and Dongguan Dongdian Testing Service Co., Ltd is assumed of full responsibility for the accuracy and completeness of these assess. After evaluation, our opinion is that the equipment In Accordance with above standard. Report No.: DDT-R21030115-2E7 Date of Receipt: Mar. 02, 2021 Date of Test: Mar. 02, 2021 ~ Mar. 23, 2021 Prepared By: Approved By: ___________________ ____________________ Talent Zhang/Engineer Damon Hu/EMC Manager Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Dongguan Dongdian Testing Service Co., Ltd. Applicant : Spigen Korea Co., Ltd. Address : 446, Bongeusa-ro, Gangnam-gu, Seoul, Rep. of Korea Equipment : Spigen PowerArc ArcField TM Model No. : PF2004 Trade Mark : Spigen Manufacturer : Spigen Korea Co., Ltd. Address : 446, Bongeusa-ro, Gangnam-gu, Seoul, Rep. of Korea Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E7 Page 4 of 11 Revision History Rev. Revisions Issue Date Revised By --- Initial issue Mar. 23, 2021 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E7 Page 5 of 11 1. General Information 1.1. Description of equipment Note: EUT is the abbreviation of equipment under test. 1.2. Assistant equipment used for test Description of Accessories Manufacturer Model number Serial No. Other Dummy load N/A N/A N/A N/A 1.3. Assess laboratory Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808 Tel.: +86-0769-38826678, http://www.dgddt.com, Email: [email protected] CNAS Accreditation No. L6451; A2LA Accreditation Number: 3870.01 FCC Designation Number: CN1182, Test Firm Registration Number: 540522 Innovation, Science and Economic Development Canada Site Registration Number: 10288A Conformity Assessment Body identifier: CN0048 VCCI facility registration number: C-20087, T-20088, R-20123, G-20118 2. Equipment used during test Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval Electric and Magnetic Field Analyzer narda EHP-200A 170WX91016 Jan. 06, 2021 1 Year EUT* Name : Spigen PowerArc ArcField TM Model Number : PF2004 EUT function description : Please reference user manual of this device Power supply : DC 5V, 9V, 12V power by external PD power adapter Wireless charging Operation frequency : 110 kHz - 145 kHz Antenna Type : Inductive loop coil antenna Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E7 Page 6 of 11 3. Method of Measurement 3.1. Applicable standard According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. According KDB680106 DR03-44118: RF Exposure Wireless Charging Apps v04. 3.2. Block diagram of test setup Note: Due to installation limitations no tests from the underside of the charging device (Test Position F) are required. 3.3…
Text truncated - open the document above for the full version.
Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E3 Page 1 of 27 FCC CERTIFICATION TEST REPORT FOR Issued By: Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808 Tel.: +86-0769-38826678, E-mail: [email protected], http://www.dgddt.com Applicant : Spigen Korea Co., Ltd. Address : 446, Bongeusa-ro, Gangnam-gu, Seoul, Rep. of Korea Equipment under Test : Spigen PowerArc ArcField TM Model No. : PF2004 Trade Mark : Spigen FCC ID : 2AFKNPF2004 Manufacturer : Spigen Korea Co., Ltd. Address : 446, Bongeusa-ro, Gangnam-gu, Seoul, Rep. of Korea ■Report No.: DDT-R21030115-2E3 ■Issued Date: Mar. 23, 2021 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E3 Page 2 of 27 Table of Contents Test report declares........................................................................................................3 1 Summary of Test Results ............................................................................................. 5 2 General Test Information .............................................................................................. 6 2.1. Description of EUT ........................................................................................................ 6 2.2. Accessories of EUT ...................................................................................................... 6 2.3. Assistant equipment used for test ................................................................................. 6 2.4. Block diagram of EUT configuration for test ................................................................. 6 2.5. Deviations of test standard ........................................................................................... 6 2.6. Test environment conditions ......................................................................................... 7 2.7. Test laboratory .............................................................................................................. 7 2.8. Measurement uncertainty ............................................................................................. 7 3 Equipment Used During Test ........................................................................................ 8 4 20 dB Bandwidth ......................................................................................................... 10 4.1. Block diagram of test setup ........................................................................................ 10 4.2. Limits .......................................................................................................................... 10 4.3. Test procedure ............................................................................................................ 10 4.4. Test result ................................................................................................................... 10 4.5. Original test data ......................................................................................................... 11 5 Radiated Emission ...................................................................................................... 12 5.1. Block diagram of test setup ........................................................................................ 12 5.2. Limit ............................................................................................................................ 13 5.3. Test procedure ............................................................................................................ 13 5.4. Test result ................................................................................................................... 14 6 Power Line Conducted Emission ................................................................................ 17 6.1. Block diagram of test setup ........................................................................................ 17 6.2. Power line conducted emission limits ......................................................................... 17 6.3. Test procedure ............................................................................................................ 17 6.4. Test result ................................................................................................................... 18 7 Antenna Requirements ............................................................................................... 21 8 Test Setup Photograph ....................................... ........................................................ 22 9 Photos of the EUT ...................................................................................................... 24 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E3 Page 3 of 27 Test Report Declare Test Standard Used: FCC Rules and Regulations Part 15 Subpart C Test procedure used: ANSI C63.10:2013 We Declare: The equipment described above is tested by Dongguan Dongdian Testing Service Co., Ltd and in the configuration tested the equipment complied with the standards specified above. The test results are contained in this test report and Dongguan Dongdian Testing Service Co., Ltd is assumed of full responsibility for the accuracy and completeness of these tests. After test and evaluation, our opinion is that the equipment provided for test compliance with the requirement of the above FCC standards. Report No.: DDT-R21030115-2E3 Date of Receipt: Mar. 02, 2021 Date of Test: Mar. 02, 2021 ~ Mar. 23, 2021 Prepared By: Approved By: ___________________ ____________________ Talent Zhang/Engineer Damon Hu/EMC Manager Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Dongguan Dongdian Testing Service Co., Ltd. Applicant : Spigen Korea Co., Ltd. Address : 446, Bongeusa-ro, Gangnam-gu, Seoul, Rep. of Korea Equipment under T…
Text truncated - open the document above for the full version.
Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E7 Page 9 of 11 4. Test Setup Photo Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E7 Page 10 of 11 Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E7 Page 11 of 11 END OF REPORT
Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E3 Page 22 of 27 8 Test Setup Photograph Dongguan Dongdian Testing Service Co., Ltd Report No.: DDT-R21030115-2E3 Page 23 of 27
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.145 MHz | - |

Selfie stick tripod with BLE
Equipment Class
DTS - Digital Transmission SystemSpigen OneTap Pro 3 Cryomax Wireless Car Charger Airvent/Spigen OneTap Pro 3 Cryomax Wireless Car Charger Airvent Hook/Spigen OneTap Pro 3 Cryomax Wireless Car Charger Dashboard
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
ArcField Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Spigen OneTap Universal Wireless Car Charger Dashboard / Windshield/ Spigen OneTap Universal Wireless Car Charger Airvent
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Spigen OneTap Pro 3 15W Wireless Car Charger Airvent/Spigen OneTap Pro 3 15W Wireless Car Charger Dashboard
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz