Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
How to get started It should only take you 15 minutes or less 1. Charge your sensor LRemove the magnetic mounting plate from the back of the sensor7 LRemove the cover from the charging port. Use the attached USB-C cable to charge Minut. Once charged, make sure to secure the cover back on. You can follow the charging progress by looking at the battery indicator at the back of the sensor. The lights will blink when charging, and turn solid when charged. A full charge should take about 1-4 hours. 2. Download the app Download the Minut app from or by downloading the or smartphone Minut appz Open the app and create your account. app.minut.com, AndroidiOS LCreate your first home following the steps in the app7 LOnce your home is ready, tap on the “+” sign in the top right corner to start the installation process. If you already have an account, just open the Minut app and log in. Not sure where to install your sensor? for tips. Click here 3. Install Minut LPeel off the sticker from the back of the mounting plate, and mount it to the ceiling or the wall7 LAttach Minut to the magnetic mounting plate. If you want to run your Minut permanently plugged in, connect it to the power outlet at this step. Sensor Charging cable (USB-C) Magnetic mounting plate Booklet Inside the box On/Off: 2 seconds Setup mode: 7 seconds Exit setup mode: 5 seconds Reset: 10 seconds Factory reset: 13 seconds Tech specs Indicators Dimension & weight Width: 115 mm Height: 28mm Power cable: 20 cm Weight: 250 gram Connection Wifi 802.11 b/g/n (2.4GHz) Bluetooth 5.2 (BLE) Battery & power Battery life ~12 months Charging via USB-C Sensors Sound Temperature Humidity Motion/PIR Tamper System requirements iOS 15 Android 5.1 and higher Operating conditions Operating temperature range: -10 to 50°C / 14°F to 122°F Relative humidity: 5%-95%, non condensing Charge port Charge indicator White solid: Fully charged White blink: Charging Red blink: Low battery General maintenance and Installation Only clean the Minut Device with a dry cloth. The device is designed to operate indoors (0 to 50°C/32°F to 122°F). Avoid direct sunlight. Low temperatures may affect battery performance negatively. The USB port should be protected using the built-in plug when not in use. Do not wash or submerge the device under water. Do not tamper, disassemble, paint, puncture, hammer, or drop the Minut Device as this may degrade performance or render Minut Device inoperable, void the warranty and the user’s authority to operate this equipment. The Minut Device contains strong magnets used to attach the device to the ceiling. Avoid direct contact with objects sensitive to magnetic fields, such as hard drives (including laptops), credit cards, etc. ⚠ Safety Notice Make sure that the mounting plate is securely attached to the underlying surface. Use a screw and the prepared mounting hole to fasten the plate if the surface is uneven or otherwise unsuitable for the adhesive tape. When attaching the sensor, make sure it aligns with the mounting plate. Failure to do the above may result in injury or damage to the sensor or property. Estimated battery life is dependent on the Wi-Fi signal strength. Interference from walls, other electrical equipment, and Wi-Fi networks may reduce the estimated battery life. Battery safety precaution -The built-in battery is not user-replaceable. Removal of the built-in battery invalidates the warranty and may destroy the device. -There is danger of explosion if the internal battery is not replaced correctly. An incorrect battery type can defeat built-in safeguards. -The battery shall not be exposed to excessive heat such as sunshine, fire or the like. -The battery can pose safety hazards when used, stored or transported in extremely high or low temperatures and in low air pressure at high altitude. -Disposing of the battery into fire or a hot oven, or mechanically crushing or cutting the battery can result in an explosion. -Leaving the battery in an extremely high-temperature surrounding environment, or in an extremely low air pressure environment, may result in an explosion or the leakage of flammable liquid or gas. Recycling The Minut Device contains a built-in, non-replaceable, lithium-ion battery. The WEEE symbol means that your device must be disposed of separately from general household waste. When it reaches its end of life, take it to a designated waste collection point in your area for safe disposal or recycling. By doing this, you’ll conserve natural resources, protect human health, and help the environment. Regulatory This is not a smoke alarm and Minut does not make a smoke alarm. To protect your home from such threats, please purchase and install separate fire and/or smoke alarms that comply with local regulatory requirements. The device DOES NOT conform to the regulatory requirements mandated for fire or smoke alarms, such as UL 217, EN14604 or any other regulatory requirement. EU Declaration of Conformity Hereby, Minut declares that theMinut Home Sensor(3rd Gen), model MT-AM1, is in compliance with relevant EU directives,includingDirective 2014/53/EU (RED), RoHS, and EMC. The full text of the EU declaration of conformityis available at: https://minut.com/legal. FCC Federal Communication Commission Interference Statement FCC ID: 2AFXO-AM01, 15.247 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, …
Text truncated - open the document above for the full version.
www.minut.com 2022-11-08 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding:FCC ID: 2AFXO-AM01 To whom it may concern: We, the undersigned, hereby authorize Compliance Certification Services (Kunshan) Inc to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own.. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Minut, Inc. This authorization is valid until further written notice from the applicant. Sincerely, Fredrik Ahlberg (Signature)(Print name) Title:Co-founder On behalf of: Minut, Inc. (Company Name) Telephone:+46705518852 E-mail: [email protected] Minut, Inc. 440 N Barranca Ave #8080, Covina, CA 91723 [email protected]
www.minut.com To:Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: Confidentiality Request regarding application forFCC ID: 2AFXO-AM01 Long term confidentiality Pursuant to 47 CFR 0.457 and 0.459, the applicant hereby requests confidential treatment of the documents listed below, associated with the certification application referenced above. ● Schematic(s) ● Block Diagrams ● Operational Description The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Fredrik Ahlberg (Signature)(Print name) Title:Co-founder On behalf of: Minut, Inc. (Company Name) Telephone:+46705518852 E-mail: [email protected] Minut, Inc. 440 N Barranca Ave #8080, Covina, CA 91723 [email protected]
Applicant Declaration Applicant Legal Business NameMinut, Inc. Address Baltzarsgatan 23 Minut AB, 211 36 Malmo, Sweden Grantee Code2AFXO FCC ID2AFXO-AM01 Authorized Contact NameFredrik Ahlberg Contact [email protected] Contact Phone+46705518852 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicantshallmake provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicantshall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs:https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs:https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100:https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature:Date: 2022-11-29 Print Name:Fredrik Ahlberg Title:Co-founder *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Applicant Declaration Rev:0.0
www.minut.com Channel Statement We, Minut, Inc. declare that this EUT (FCC ID: 2AXFO-AM01,IC: 23212-AM01) doesn’t have ad hoc mode function on “non-US/Canada frequencies“. In addition, the frequency selection feature is disabled by firmware for devices marketed to the US/Canada. For the DTS part of this device, only channels 1-11 will be used in North America. Country code selection is disabled. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Fredrik Ahlberg (Signature)(Print name) Title:Co-founder On behalf of: Minut, Inc. (Company Name) Telephone:+46705518852 E-mail: [email protected] Minut, Inc. 440 N Barranca Ave #8080, Covina, CA 91723 [email protected]
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 1 of 4 Appendix External Photos for FYCR2210000427AT FCC ID: 2AXFO-AM01 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 2 of 4 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 3 of 4 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A02 Rev.A/0 Page: 4 of 4
www.minut.com Amarillo Label History RevisionDateAuthorChange 12022-10-07FAInitial revision 22022-11-29FAUpdated marking layout to include FCC notice. Corrected IC ID. 32022-12-22FAUpdated product name. Minut AB.Registered address: Baltzarsgatan 23, 21136, Malmö. Company registration number: 559006-3920. Email:[email protected] Number: SE559006392001 www.minut.com Render The information is permanently marked using a fibre laser on the back of the device. The diameter of the marking outline is approximately 66 mm. The CE mark is 5.2 mm high. The RCM mark is 5.5 mm high. The WEEE waste bin mark is 7.7mm high. The WEEE bar is 1.2 mm thick. The FCC ID and IC ID are 1.4mm high. Minut AB.Registered address: Baltzarsgatan 23, 21136, Malmö. Company registration number: 559006-3920. Email:[email protected] Number: SE559006392001 www.minut.com External photo Minut AB.Registered address: Baltzarsgatan 23, 21136, Malmö. Company registration number: 559006-3920. Email:[email protected] Number: SE559006392001
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 1 of 6 Appendix Internal Photos for FYCR2210000427AT FCC ID: 2AXFO-AM01 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 2 of 6 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 3 of 6 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 4 of 6 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 5 of 6 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-A03 Rev.A/0 Page: 6 of 6 - End of the Appendix -
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042702 Page: 1 of 82 Winkey Wang EMC Technical Manager TEST REPORT Application No.: FYCR2210000427AT Applicant: Minut, Inc. Address of Applicant: Baltzarsgatan 23 Minut AB Malmo 211 36 Sweden Manufacturer: Minut, Inc. Address of Manufacturer: Baltzarsgatan 23 Minut AB Malmo 211 36 Sweden Factory: Scanfil Malmö AB Address of Factory: Bronsyxegatan 6B, 213 75 Malmö, Sweden Equipment Under Test (EUT): EUT Name: Minut Home Sensor Model No.: MT-AM1 Trade Mark: Minut FCC ID: 2AFXO-AM01 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2022-10-31 Date of Test: 2022-11-02 to 2022-11-11 Date of Issue: 2022-11-28 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042702 Page: 2 of 82 Revision Record Version Chapter Date Modifier Remark 01 2022-11-28 Original Authorized for issue by: Tree Zhan/Project Engineer Winkey Wang/Reviewer Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042702 Page: 3 of 82 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042702 Page: 4 of 82 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 6 4.4 TEST LOCATION .................................................................................................................................... 7 4.5 TEST FACILITY ...................................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 7 5 EQUIPMENT LIST ...................................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 11 6.1 ANTENNA REQUIREMENT .................................................................................................................... 11 6.1.1 Test Requirement: ....................................................................................................................... 11 6.1.2 Conclusion ................................................................................................................................... 11 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 12 7.1 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ........................................................... 12 7.1.1 E.U.T. Operation .......................................................................................................................... 12 7.1.2 Test Mode Description ................................................................................................................. 12 7.1.3 Test Setup Diagram ..................................................................................................................... 12 7.1.4 Measurement Procedure and Data............................................................................................. 13 7.2 CONDUCTED PEAK OUTPUT POWER ......................................................…
Text truncated - open the document above for the full version.
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042703 Page: 1 of 114 Winkey Wang EMC Technical Manager TEST REPORT Application No.: FYCR2210000427AT Applicant: Minut, Inc. Address of Applicant: Baltzarsgatan 23 Minut AB Malmo 211 36 Sweden Manufacturer: Minut, Inc. Address of Manufacturer: Baltzarsgatan 23 Minut AB Malmo 211 36 Sweden Factory: Scanfil Malmö AB Address of Factory: Bronsyxegatan 6B, 213 75 Malmö, Sweden Equipment Under Test (EUT): EUT Name: Minut Home Sensor Model No.: MT-AM1 Trade Mark: Minut FCC ID: 2AFXO-AM01 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2022-10-31 Date of Test: 2022-11-02 to 2022-11-11 Date of Issue: 2022-11-28 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042703 Page: 2 of 114 Revision Record Version Chapter Date Modifier Remark 01 2022-11-28 Original Authorized for issue by: Tree Zhan/Project Engineer Winkey Wang/Reviewer Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042703 Page: 3 of 114 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 11.9.2 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042703 Page: 4 of 114 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 6 4.4 TEST LOCATION ............................................................................................................................. 7 4.5 TEST FACILITY ............................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 7 5 EQUIPMENT LIST ............................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................11 6.1 ANTENNA REQUIREMENT ................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion ..............................................................................................................................11 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................12 7.1 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ........................................................12 7.1.1 E.U.T. Operation .....................................................................................................................12 7.1.2 Test Mode Description ............................................................................................................12 7.1.3 Test Setup Diagram ................................................................................................................13 7.1.4 Measurement Procedure and Data .........................................................................................13 7.2 CONDUCTED PEAK OUTPUT POWER ................................................................................................16 7.2.1 E.U.T. Operation .....................................................…
Text truncated - open the document above for the full version.
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042703 Page: 51 of 114 7.8 Radiated Spurious Emissions Below 1GHz Test Requirement 47 CFR Part 15, Subpart C 15.205 & 15.209 Test Method: ANSI C63.10 (2013) Section 6.4,6.5 Measurement Distance: 3m Limit: Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters) 0.009-0.490 2400/F(kHz) 300 0.490-1.705 24000/F(kHz) 30 1.705-30.0 30 30 30-88 100 3 88-216 150 3 216-960 200 3 960-1000 500 3 7.8.1 E.U.T. Operation Operating Environment: Temperature: 22.3 °C Humidity: 52.9 % RH Atmospheric Pressure: 1020 mbar 7.8.2 Test Mode Description Pre-scan / Final test Mode Code Description Pre-scan 04 TX mode_Keep the EUT in continuously transmitting mode with all modulation types. All data rates for each modulation type have been tested and found the data rate @ 1Mbps is the worst case of IEEE 802.11b; data rate @ 6Mbps is the worst case of IEEE 802.11g; data rate @ 6.5Mbps is the worst case of IEEE 802.11n(HT20), final test modes are considering the modulation and worse data rates. Only the data of worst case is recorded in the report. Final test 05 Charge + TX mode_Keep the EUT in charging and continuously transmitting mode with all modulation types. All data rates for each modulation type have been tested and found the data rate @ 1Mbps is the worst case of IEEE 802.11b; data rate @ 6Mbps is the worst case of IEEE 802.11g; data rate @ 6.5Mbps is the worst case of IEEE 802.11n(HT20), final test modes are considering the modulation and worse data rates. Only the data of worst case is recorded in the report. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch SZCCS-TRF-01 Rev. A/0 Aug01,2022 Report No.: FYCR221000042703 Page: 52 of 114 7.8.3 Test Setup Diagram 7.8.4 Measurement Procedure and Data a. For below 1GHz, the EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 or 10 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation. b. The EUT was set 3 or 10 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. c. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading. e. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. f. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using quasi-peak method as specified and then reported in a data sheet. g. Test the EUT in the lowest channel, the middle channel, the Highest channel. h. The radiation measurements are performed in X, Y, Z axis positioning for Transmitting mode, and found the X axis positioning which it is the worst case. i. Repeat above procedures until all frequencies measured was complete. Remark: 1. Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor 2. Scan from 9kHz to 30MHz, the disturbance below 30MHz was very low. The points mark…
Text truncated - open the document above for the full version.
Fuyong Lab Xinlong Techno Park Fengtang Road · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 45.10 mW |

Minut Eureka wireless module
Equipment Class
DTS - Digital Transmission System
Point Smart Home Monitor
Equipment Class
DTS - Digital Transmission System