Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User Manual AGENT E 3000-U902-4X This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. Modifications not expressly approved by this company could void the user's authority to operate the equipment. FCC ID: 2AGCT-U9024X Amtsgericht Wuppertal, HR-A 21086 / HR-B 17580 Persönlich haftender Gesellschafter: EMKA Beschlagteile Beteiligungsges. mbH, Sitz Velbert St.Nr.: 139 5713 0385 * ID-Nr.: DE 121544396 Geschäftsführer: Friedhelm Runge, Ulrich Kudlinski, Peter Magnusson, Mark Runge, Joachim F. Wolff Table of Contents Introduction States of the Locking System Factory Mode On-Site-Mode Stand Alone On-Site-Mode Radio Communication Opening Emergency Opening Failure Mode: No Battery Power Failure Mode: No Radio Communication Battery Life and Replacement Amtsgericht Wuppertal, HR-A 21086 / HR-B 17580 Persönlich haftender Gesellschafter: EMKA Beschlagteile Beteiligungsges. mbH, Sitz Velbert St.Nr.: 139 5713 0385 * ID-Nr.: DE 121544396 Geschäftsführer: Friedhelm Runge, Ulrich Kudlinski, Peter Magnusson, Mark Runge, Joachim F. Wolff Introduction Agent E Wireless Swing Handle 3000-U902-4X The Agent E Wireless is as yet the only swing handle based on wireless communication. Due to its wireless and thus cost-saving mounting it is most suitable for retrofitting in data centers. The authentication is performed by RFID or fingerprint. Highly-efficient power management guarantees a long battery life. Features • Wireless communication via wireless network 922 MHz (industry standard) • Control of up to 2,000 doors in a wireless network via access units and control unit • Authentication via 125 kHz or 13.56 MHz transponder cards or via fingerprint. Remote- controlled opening is also always possible • Handle type Wireless Slave does not have its own authentication and is unlocked in combination with master handle or by remote- controlled opening. The opening is effected by touching the sensor field • All handles excel at extremely energy-efficient battery operation (service life battery min. 3 years) and have one port for one door contact • Emergency power function or emergency opening via integrated USB port • AGENT E Wireless is most suitable for retrofitting in data centers due to its wireless mounting. • Suitable for mounting in cabinets by different manufacturers Amtsgericht Wuppertal, HR-A 21086 / HR-B 17580 Persönlich haftender Gesellschafter: EMKA Beschlagteile Beteiligungsges. mbH, Sitz Velbert St.Nr.: 139 5713 0385 * ID-Nr.: DE 121544396 Geschäftsführer: Friedhelm Runge, Ulrich Kudlinski, Peter Magnusson, Mark Runge, Joachim F. Wolff States of the Locking System Factory Mode The AGENT E swing handle is delivered in an open position, protected by a suitable cover to avoid accidental closing. Batteries are packed separately in the accessory bag. On-Site-Mode “Stand Alone” First mount swing handle onto the door and insert AAA batteries into the housing. Position battery cover into place and fasten screw securely. Now push swing handle into its closed position. The AGENT E can now be opened with the corresponding card. At this time, there will be no wireless connection because the Access Units Wireless is not installed and configured yet. On-Site-Mode Radio Communication After the Access Units Wireless is installed and configured, the communication with the AGENT E will start automatically. Furthermore the AGENT E can still be opened with the corresponding card. The authorization of the card will be validated by the system before access is granted or denied if necessary. Amtsgericht Wuppertal, HR-A 21086 / HR-B 17580 Persönlich haftender Gesellschafter: EMKA Beschlagteile Beteiligungsges. mbH, Sitz Velbert St.Nr.: 139 5713 0385 * ID-Nr.: DE 121544396 Geschäftsführer: Friedhelm Runge, Ulrich Kudlinski, Peter Magnusson, Mark Runge, Joachim F. Wolff Opening The opening procedure in two steps: (1) Wake Up By default the swing handle is in an inactive mode to conserve energy. To reactive, touch round center button for min. 3 seconds until left green LED starts blinking. (2) Authorization with card As long as the left green LED blinks, the swing handle is able to read the provided card and the authorization process begins. Authorization is granted as soon as the green LED on the right side starts blinking. In case of a denied access the right LED will start blinking red. Amtsgericht Wuppertal, HR-A 21086 / HR-B 17580 Persönlich haftender Gesellschafter: EMKA Beschlagteile Beteiligungsges. mbH, Sitz Velbert St.Nr.: 139 5713 0385 * ID-Nr.: DE 121544396 Geschäftsführer: Friedhelm Runge, Ulrich Kudlinski, Peter Magnusson, Mark Runge, Joachim F. Wolff Wake up OK Access grantedAccess denied Emergency Opening Failure Mode: No Battery Power In case of depleted battery or total power failure, the AGENT E can be provided with the necessary energy through the integrated USB port. To do so, connect a PC or the approved power pack to the USB port. Failure Mode: No Radio Communication In case of a total communication failure, an array of master cards will be available to open swing handle nonetheless. Amtsgericht Wuppertal, HR-A 21086 / HR-B 17580 Persönlich haftender Gesellschafter: EMKA Beschlagteile Beteiligungsges. mbH, Sitz Velbert St.Nr.: 139 5713 0385 * ID-Nr.: DE 121544396 Geschäftsführer: Friedhelm Runge, Ulrich Kudlinski, Peter Magnusson, Mark Runge, Joachim F. Wolff Battery Life and Replacement A variety of factors (shelf life, openings per day, environment, battery brand, etc.) will determine how long your lock operates on a set of batteries. In average conditions, you can expect up to 3 years for AGENT E minimum. A low battery condition is identified by a flash light of both LEDs when an access process is running. When the low battery condition is observed, the batteries should be replaced as soon…
Text truncated - open the document above for the full version.
External Photos page 1 Model No.: 3000-U902-4X FCC ID: 2AGCT-U9024X Project No.: G0M-1510-5134
EUT Labeling AgentE USA/SGP, 3000-U902-4X Rear FCC Label Details 1/1
Internal Photos page 1 Model No.: 3000-U902-4X FCC ID: 2AGCT-U9024X Project No.: G0M-1510-5134 Internal Photos page 2 Model No.: 3000-U902-4X FCC ID: 2AGCT-U9024X Project No.: G0M-1510-5134 Internal Photos page 3 Model No.: 3000-U902-4X FCC ID: 2AGCT-U9024X Project No.: G0M-1510-5134 Antenne
Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 1 of 13 RF-EXPOSURE ASSESSMENT REPORT FCC 47 CFR Part 2.1091 Industry Canada RSS-102 RF-Exposure evaluation of mobile equipment Report Reference No. ..................... : G0M-1510-5134-TFC091ME-V02 Testing Laboratory ......................... : Eurofins Product Service GmbH Address............................................. : Storkower Str. 38c 15526 Reichenwalde Germany Accreditation ..................................... : A2LA Accredited Testing Laboratory, Certificate No.: 1983.01 FCC Filed Test Laboratory, Reg.-No.: 96970 IC OATS Filing assigned code: 3470A Applicant’s name ............................ : EMKA Beschlagteile GmbH & Co. KG Address............................................. : Langenberger Straße 32 42551 Velbert GERMANY Test specification: Standard ........................................... : 47 CFR 1.1310 / 47 CFR 2.1091 / 47 CFR 2.1093 OET Bulletin 65:1997 RSS-102, Issue 5:2015-03 Safety Code 6:2015-03 Equipment under test (EUT): Product description AgentE USA/SGP Model No. 3000-U902-4X Additional Model(s) None Brand Name(s) EMKA Hardware version 901.343B001 Firmware / Software version 350000091 FCC-ID: 2AGCT-U9024X IC: N/A Test result Passed Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 3 of 13 Version History Version Issue Date Remarks Revised by 01 2015-11-18 Initial Release 02 2015-12-09 RFID frequency corrected C. Weber Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 4 of 13 REPORT INDEX 1 EQUIPMENT (TEST ITEM) DESCRIPTION 5 1.1 Reference Documents 6 1.2 Standalone Radiation Sources 7 1.3 Multi-transmitter Modes 8 2 RESULT SUMMARY 9 3 RF-EXPOSURE CLASSIFICATIONS 10 4 ASSESSMENT 11 4.1 MPE Assessment Conditions – 47 CFR 2.1091 / RSS-102 11 4.2 Single-Transmitter Assessment – 47 CFR 2.1091 / RSS-102 13 Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 5 of 13 1 Equipment (Test item) Description Description AgentE USA/SGP Model 3000-U902-4X Additional Model(s) None Brand Name(s) EMKA Serial number None Hardware version 901.343B001 Software / Firmware version 350000091 FCC-ID 2AGCT-U9024X IC N/A Equipment type End product Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 6 of 13 1.1 Reference Documents Document type Document No. Issued by Date FCC 15.249 Test Report G0M-1510-5134-TFC249DT-V01 Eurofins Product Service GmbH 2015-11-18 FCC 15.225 Test Report G0M-1510-5134-TFC225RI-V01 Eurofins Product Service GmbH 2015-11-18 Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 7 of 13 1.2 Standalone Radiation Sources Mode # Description 922 MHz Frequency range [MHz] 922.5 Transmission modes GFSK Maximum conducted power [dBm] N/A Maximum radiated power [dBm] -12.37 Maximum transmission duty cycle [%] 100 Antenna gain [dBi] N/A Antenna diameter [cm] 1.0 Assessment Frequency [MHz] 922.5 Due to the extremely low radiated power the 13.56 MHz RFID transmitter is omitted from rf-exposure evaluation Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 8 of 13 1.3 Multi-transmitter Modes None Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 9 of 13 2 Result Summary FCC 47 CFR Part 2.1091, IC RSS-102 Product Specific Standard Section Requirement Result Remarks 47 CFR 2.1091 Maximum permissible exposure @ 20cm below limit PASS RSS-102 2.5.2 Maximum permissible exposure @ 20cm below limit PASS Remarks: Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 10 of 13 3 RF-Exposure Classifications Device Types Fixed A fixed device is defined as a device physically secured at one fixed location and cannot be easily re-located. Mobile A mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons. (47 CFR 2.1091) Portable A portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. (47 CFR 2.1093) Exposure Categories Occupational / Controlled Limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. General population / uncontrolled Exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. Test Report No.: G0M-1510-5134-TFC091ME-V02 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 11 of 13 4 Assessment 4.1 MPE Assessment Conditions – 47 CFR 2.1091 / RSS-102 MPE ASSESSMENT ACC. TO 47 CFR 2.1091 / IC RSS-102 VERDICT: PASS Assessment according to reference Reference Method FCC OET Bulletin 65 / RSS-102 & Safety Code 6 Device type mobile Exposure category General public IC Limits – Occupational …
Text truncated - open the document above for the full version.
Test Report No.: G0M-1510-5134-TFC249DT-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 1 of 40 FCC TEST REPORT FCC 47 CFR Part 15C Industry Canada RSS-210 Intentional radiator operating within the 902 – 928 MHz band Report Reference No. .................... : G0M-1510-5134-TFC249DT-V01 Testing Laboratory ........................ : Eurofins Product Service GmbH Address ............................................ : Storkower Str. 38c 15526 Reichenwalde Germany Accreditation .................................... : A2LA Accredited Testing Laboratory, Certificate No.: 1983.01 FCC Filed Test Laboratory, Reg.-No.: 96970 IC OATS Filing assigned code: 3470A Applicant’s name ........................... : EMKA Beschlagteile GmbH & Co. KG Address ............................................ : Langenberger Straße 32 42551 Velbert GERMANY Test specification: Standard ........................................... : 47 CFR Part 15C RSS-210, Issue 8, 2010-12 RSS-Gen, Issue 4, 2014-11 ANSI C63.4:2014 Test scope.............. ....................... : complete Radio compliance test Equipment under test (EUT): Product description AgentE USA/SGP Model No. 3000-U902-4X Additional Model(s) None Brand Name(s) EMKA Hardware version 901.343B001 Firmware / Software version 350000091 FCC-ID: 2AGCT-U9024X IC: None Test result Passed Test Report No.: G0M-1510-5134-TFC249DT-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 3 of 40 Version History Version Issue Date Remarks Revised by 01 2015-11-18 Initial Release Test Report No.: G0M-1510-5134-TFC249DT-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 4 of 40 REPORT INDEX 1 EQUIPMENT (TEST ITEM) DESCRIPTION 5 1.1 Photos – Equipment External 6 1.2 Photos – Equipment internal 8 1.3 Photos – Test setup 11 1.4 Supporting Equipment Used During Testing 12 1.5 Test Modes 13 1.6 Test Equipment Used During Testing 14 1.7 Sample emission level calculation 15 2 RESULT SUMMARY 16 3 TEST CONDITIONS AND RESULTS 17 3.1 Test Conditions and Results – Occupied Bandwidth 17 3.2 Test Conditions and Results – Fundamental field strength emissions 19 3.3 Test Conditions and Results – Emissions radiated outside the specified frequency band 21 3.4 Test Conditions and Results – Receiver radiated emissions 23 ANNEX A Transmitter radiated spurious emissions 25 ANNEX B Receiver radiated spurious emissions 33 Test Report No.: G0M-1510-5134-TFC249DT-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 5 of 40 1 Equipment (Test item) Description Description AgentE USA/SGP Model 3000-U902-4X Additional Model(s) None Brand Name(s) EMKA Serial number None Hardware version 901.343B001 Software / Firmware version 350000091 FCC-ID 2AGCT-U9024X IC None Equipment type End product Radio type Transceiver Radio technology custom Operating frequency range 922.5 MHz Assigned frequency band 902 - 928 MHz Frequency range F MID 922.5 MHz Spreading None Modulations GFSK Number of channels 1 Channel spacing None Number of antennas 1 Antenna Type integrated Model 306.021, 55 mm wire antenna Manufacturer In-Circuit GmbH Gain unspecificated Manufacturer EMKA Beschlagteile GmbH & Co. KG Langenberger Straße 32 42551 Velbert GERMANY Power supply V NOM 3.0 VDC (Lithium-Battery) V MIN N/A V MIN N/A AC/DC-Adaptor Model N/A Vendor N/A Input N/A Output N/A Test Report No.: G0M-1510-5134-TFC249DT-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 12 of 40 1.4 Supporting Equipment Used During Testing Product Type* Device Manufacturer Model No. Comments None *Note: Use the following abbreviations: AE : Auxiliary/Associated Equipment, or SIM : Simulator (Not Subjected to Test) CABL : Connecting cables Test Report No.: G0M-1510-5134-TFC249DT-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 13 of 40 1.5 Test Modes Mode # Description Single General conditions: EUT powered by fully battery Radio conditions: Mode = standalone transmit Modulation = GFSK Power level = Maximum Receive General conditions: EUT powered by fully battery Radio conditions: Mode = standalone receive Modulation = GFSK Test Report No.: G0M-1510-5134-TFC249DT-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 14 of 40 1.6 Test Equipment Used During Testing Measurement Software Description Manufacturer Name Version EMC Test Software Dare Instruments Radimation 2014.1.15 Occupied Bandwidth Description Manufacturer Model Identifier Cal. Date Cal. Due Spectrum Analyzer R&S FSP 30 EF00312 2015-02 2016-02 Field strength emissions Description Manufacturer Model Identifier Cal. Date Cal. Due Semi-anechoic chamber Frankonia AC 1 EF00062 - - Spectrum Analyzer R&S FSIQ26 EF00242 2015-04 2016-04 Biconical Antenna R&S HK 116 EF00012 2013-02 2016-02 LPD Antenna R&S HL 223 EF00187 2014-03 2017-03 LPD Antenna R&S HL 025 EF00327 2015-10 2018-10 Test Report No.: G0M-1510-5134-TFC249DT-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 15 of 40 1.7 Sample emission level calculation The following is a description of terms and a sample calculation, as appears in the radiated emissions data table. The numbers used in the calculation are for example only. There is no direct correlation to the specific data taken for the product described in this document: Reading: This is the reading obtained on the spectrum analyzer in dBμV. Any external preamplifiers used are taken into account through internal analyzer settings. A.F.: This is the antenna factor for the receiving antenna. It is a conversion factor, which converts electric fields strengths to voltages, which can be measured directly on the spectrum analyzer. It is treated as a loss in dB. Cable losses have been included with the A.F. to simplify the calculations. The antenna factor is used in calculations as follows: Reading on Analyze…
Text truncated - open the document above for the full version.
Test Report No.: G0M-1510-5134-TFC225RI-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 1 of 29 FCC TEST REPORT FCC 47 CFR Part 15C Industry Canada RSS-210 Operation within the 13.110 – 14.010 MHz band Report Reference No. .................... : G0M-1510-5134-TFC225RI-V01 Testing Laboratory ........................ : Eurofins Product Service GmbH Address ............................................ : Storkower Str. 38c 15526 Reichenwalde Germany Accreditation .................................... : A2LA Accredited Testing Laboratory, Certificate No.: 1983.01 FCC Filed Test Laboratory, Reg.-No.: 96970 IC OATS Filing assigned code: 3470A Applicant’s name ........................... : EMKA Beschlagteile GmbH & Co. KG Address ............................................ : Langenberger Straße 32 42551 Velbert GERMANY Test specification: Standard ........................................... : 47 CFR Part 15C RSS-210, Issue 8, 2010-12 RSS-Gen, Issue 4, 2014-11 ANSI C63.4:2014 Test scope.............. ....................... : complete Radio compliance test Equipment under test (EUT): Product description AgentE USA/SGP Model No. 3000-U902-4X Additional Model(s) None Brand Name(s) EMKA Hardware version 901.343B001 Firmware / Software version 350000091 FCC-ID: 2AGCT-U9024X IC: N/A Test result Passed Test Report No.: G0M-1510-5134-TFC225RI-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 3 of 29 Version History Version Issue Date Remarks Revised by 01 2015-11-18 Initial Release Test Report No.: G0M-1510-5134-TFC225RI-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 4 of 29 REPORT INDEX 1 EQUIPMENT (TEST ITEM) DESCRIPTION 5 1.1 Photos – Equipment External 6 1.2 Photos – Equipment internal 8 1.3 Photos – Test setup 12 1.4 Supporting Equipment Used During Testing 13 1.5 Test Modes 14 1.6 Test Equipment Used During Testing 15 1.7 Sample emission level calculation 16 2 RESULT SUMMARY 17 3 TEST CONDITIONS AND RESULTS 18 3.1 Test Conditions and Results – Occupied Bandwidth 18 3.2 Test Conditions and Results – Fundamental in-band field strength emissions 19 3.3 Test Conditions and Results – Emissions radiated outside the specified frequency band 21 3.4 Test Conditions and Results – Frequency stability 23 ANNEX A Transmitter in-band emissions 25 ANNEX B Transmitter radiated spurious emissions 26 Test Report No.: G0M-1510-5134-TFC225RI-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 5 of 29 1 Equipment (Test item) Description Description AgentE USA/SGP Model 3000-U902-4X Additional Model(s) None Brand Name(s) EMKA Serial number None Hardware version 901.343B001 Software / Firmware version 350000091 FCC-ID 2AGCT-U9024X IC N/A Equipment type End product Radio type Transceiver Radio technology 13.56 MHz RFID Operating frequency range 13.56 MHz Assigned frequency band 13.110 - 14.010 MHz Frequency range F MID 13.56 MHz Spreading None Modulations ASK Number of channels 1 Channel spacing None Number of antennas 1 Antenna Type integrated Model printed loop antenna Manufacturer In-circuit Manufacturer EMKA Beschlagteile GmbH & Co. KG Langenberger Straße 32 42551 Velbert GERMANY Power supply V NOM 3.0 V DC V MIN 2.4 V DC V MAX 3.2 V DC Temperatures T NOM 20 °C T MIN 5 °C T MAX 50 °C AC/DC-Adaptor Model N/A Vendor N/A Input N/A Output N/A Test Report No.: G0M-1510-5134-TFC225RI-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 13 of 29 1.4 Supporting Equipment Used During Testing Product Type* Device Manufacturer Model No. Comments None *Note: Use the following abbreviations: AE : Auxiliary/Associated Equipment, or SIM : Simulator (Not Subjected to Test) CABL : Connecting cables Test Report No.: G0M-1510-5134-TFC225RI-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 14 of 29 1.5 Test Modes Mode # Description Single - CW General conditions: EUT powered by battery Radio conditions: Mode = standalone transmit Modulation = none Power level = Maximum Single General conditions: EUT powered by battery Radio conditions: Mode = standalone transmit Modulation = ASK Power level = Maximum Test Report No.: G0M-1510-5134-TFC225RI-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 15 of 29 1.6 Test Equipment Used During Testing Measurement Software Description Manufacturer Name Version EMC Test Software Dare Instruments Radimation 2014.1.15 Occupied Bandwidth Description Manufacturer Model Identifier Cal. Date Cal. Due Spectrum Analyzer R&S FSP 30 EF00312 2015-02 2016-02 Field strength emissions Description Manufacturer Model Identifier Cal. Date Cal. Due Semi-anechoic chamber Frankonia AC 1 EF00062 - - Spectrum Analyzer R&S FSIQ26 EF00242 2015-04 2016-04 Loop Antenna R&S HFH2-Z2 EF00184 2014-11 2016-11 Biconical Antenna R&S HK 116 EF00012 2013-02 2016-02 LPD Antenna R&S HL 223 EF00187 2014-03 2017-03 LPD Antenna R&S HL 025 EF00327 2015-10 2018-10 Test Report No.: G0M-1510-5134-TFC225RI-V01 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 16 of 29 1.7 Sample emission level calculation The following is a description of terms and a sample calculation, as appears in the radiated emissions data table. The numbers used in the calculation are for example only. There is no direct correlation to the specific data taken for the product described in this document: Reading: This is the reading obtained on the spectrum analyzer in dBμV. Any external preamplifiers used are taken into account through internal analyzer settings. A.F.: This is the antenna factor for the receiving antenna. It is a conversion factor, which converts electric fields strengths to voltages, which can be measured directly on the spectrum analyzer. It is treated as a loss in dB. Cable losses have been included with the A.F. to simplify the calculations. The antenna …
Text truncated - open the document above for the full version.
TSup Photos page 1 Model No.: 3000-U902-4X FCC ID: 2AGCT-U9024X Project No.: G0M-1510-5134
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 13.56 MHz - 13.56 MHz | - |

AgentE-radino AccessPoint USA/SGP
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter