
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Operation Overview Packing • Auden Bamboo Wireless Charger •USB-A to USB-C Type Charging Cable •User Manual Indicating status and protection function 1. LED blue light: Standby 2. LED green light: Charging 3. Blue light flashing: device is not correctly placed on the wireless charger, over temperature protection, or detects metal on the back of the device Note: Only the QC2.0/QC3.0 Standard power adapter can support this product's fast charging. Adapters are not included with the product. 1. Plug the power adapter into the wall socket (adapter not included) 2. USB-A side connects to the power wall adapter, USB-C side connects to the wireless charger side, the LED light will illuminate blue which means the unit is ready to charge your device. 3. Place your device on to the wireless charger, the LED light will change from blue to green which denotes the device is being charged. Auden Bamboo Wireless Charger Instruction Manual IC ID: 21530-101517 FCC ID: 2AGR4-101517 Specification Qi Certified Input: 5V/2.0A, 9V/2.0A Output: 5W/7.5W/10W Charging frequency: 110.3-205 KHz Transmission Distance: ≤5mm Efficiency: ≥75% Product size: Φ100*11mm FCC Statement This device complies with part 15 of the FCC Rules. Operation is Subject To the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the party responsible for compliance could v oid the user's authority to operate this equipment. Note: this equipment has been tested and found to comply with the limits for a Class B digital device, purs uant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and candidate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communica-tions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. ISED Statement This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: ● This device may not cause interference; and ● This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: ● l’appareil ne doit pas produire de brouillage; ● l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 10 cm surrounding the device and 10 cm above the top surface of the device must be respected. Cet équipement est conforme Canada limites d'exposition aux radiations dans un environnement non contrôlé. au cours de l'opération de l'appareil sur une distance de 10 cm autour de l'appareil et de 10 cm au - dessus de la surface supérieure de l'appareil doit être respecté. page 03 page 04 page 02 page 06 page 07 page 08page 05 Indicator Indicator Power Adapter Wireless charger USB Micro Cable Type-C interface
The Gem Group, Inc. Agent Authorization Company: The Gem Group, Inc. Address: 9 International Way, Lawrence, MA 01843, USA Product Name: AUDEN BAMBOO WIRELESS CHARGER Trade Mark: Gemline Model Number(s): 101517-231B FCC ID: 2AGR4-101517 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2022-06-07 Name: Tina Song Title: Manager Company: The Gem Group, Inc.
The Gem Group, Inc. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2022-06-07 Subject; Request for Confidentiality FCC ID: 2AGR4-101517 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Tina Song Title: Manager
Page 1 of 4 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 1. EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8
Page 1 of 1 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L4.5cm x 4.5cm) Label Location FCC ID: 2AGR4-101517 IC: 21530-101517 Input: 5V/2.0A,9V/2.0A Output: 5W/7.5W/10W
Page 1 of 4 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 1. INTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Coil Antenna Page 3 of 4 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8
Page 1 of 10 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report 1. Product Information FCC ID: 2AGR4-101517 Number of tested samples 2 Sample number 220422011A-1(Engineer sample), 220422011A-2(Normal sample) Product Name AUDEN BAMBOO WIRELESS CHARGER Model Number 101517-231B Power Supply Input: 5V2.0A, 9V2.0A Output: 5W/7.5W/10W Modulation Type Continuous Wave Frequency Range 110.3~205.0KHz Antenna Type Coil Antenna Hardware version / Software version / Accessories / Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Consumer wireless power transfer devices approved under Part 18 in some cases have to demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed according to the operating configurations of the wireless system and the exposure conditions of users and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at maximum output power. The RF exposure requirements must be determined in conjunction with the device operating characteristics, according to the mobile and portable exposure requirements in Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the FCC rules. 2) Based on the design and implementation of the power transfer application, it must be clearly identified if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of the rules may apply. 3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits Page 2 of 10 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity below 100 kHz. 4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements. Existing SAR systems and test procedures are generally intended for measurements above 100 MHz. While numerical modeling can be an alternative, the constraints of substantial computational resources at low frequencies could introduce further limitations. Under these circumstances, including operations below 100 kHz, the Commission may consider a combination of analytical analysis, field strength, radiated and conducted power measurements, in conjunction with some limited numerical modeling to assess compliance. 5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation they should contact the FCC Laboratory with sufficient system operating configuration details to determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures. Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons, information on device design, implementation, operating configurations, exposure conditions of users and bystanders are needed to determine the evaluation and testing requirements. In addition, the influence of nearby objects may also need consideration according to the wireless power transfer system implementation; for example, the effects of placing the device, its coils or radiating elements on or near metallic surfaces 3. Evaluation Limit 3.1 Refer evaluation method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices FCC CFR 47 part 18.107:Indusial, Scientific, and Medical Equipment Page 3 of 10 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3.2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Lim…
Text truncated - open the document above for the full version.
Page 1 of 23 FCC ID: 2AGR4-101517 Report No.: LCS220422011AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For The Gem Group, Inc. AUDEN BAMBOO WIRELESS CHARGER Test Model: 101517-231B Prepared for : The Gem Group, Inc. Address : 9 International Way, Lawrence, MA 01843, USA Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : May 06, 2022 Number of tested samples : 2 Serial number : 220422011A-1(Engineer sample), 220422011A-2(Normal sample) Date of Test : May 06, 2022 ~ May 19, 2022 Date of Report : May 20, 2022 Page 2 of 23 FCC ID: 2AGR4-101517 Report No.: LCS220422011AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15C Report Reference No. ................. : LCS220422011AEA Date Of Issue ................................. : May 20, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Shajing Street, Baoan District, Shenzhen, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : The Gem Group, Inc. Address .......................................... : 9 International Way, Lawrence, MA 01843, USA Test Specification Standard ......................................... : FCC CFR 47 PART 15C Test Report Form No...................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : AUDEN BAMBOO WIRELESS CHARGER Trade Mark ..................................... : Gemline Test Model ...................................... : 101517-231B Power Supply ................................. : Input: 5V2.0A,9V2.0A Output: 5W/7.5W/10W Result ........................................... : Positive Compiled by: Supervised by: Approved by: Jack Liu/ Administrator Jin Wang/ Technique principal Gavin Liang/ Manager Page 3 of 23 FCC ID: 2AGR4-101517 Report No.: LCS220422011AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS220422011AEA May 20, 2022 Date of issue Test Model.............................. : 101517-231B EUT......................................... : AUDEN BAMBOO WIRELESS CHARGER Applicant............................... : The Gem Group, Inc. Address.................................. : 9 International Way, Lawrence, MA 01843, USA Telephone............................... : / Fax.......................................... : / Manufacturer........................ : ShenzhenFuturechargerTechnologyCo.,Ltd Address................................... : Yongfengtianindustiralpark, 3rd industrialzone, fenghuang, Fuyong, Bao'anDistrict, Shenzhen, China.51810 Telephone............................... : / Fax.......................................... : / Factory................................... : ShenzhenFuturechargerTechnologyCo.,Ltd Address................................... : Yongfengtianindustiralpark, 3rd industrialzone, fenghuang, Fuyong, Bao'anDistrict, Shenzhen, China.51810 Telephone............................... : / Fax.......................................... : / Page 4 of 23 FCC ID: 2AGR4-101517 Report No.: LCS220422011AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 May 20, 2022 Initial Issue -- Page 5 of 23 FCC ID: 2AGR4-101517 Report No.: LCS220422011AEA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS 1. GENERAL INFORMATION ............................................................................................. 6 1.1 Description of Device (E…
Text truncated - open the document above for the full version.
Page 1 of 2 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Photographs of Test Setup Conducted Emission-AC adapter charge mode Radiated Emission below 30MHz-AC adapter charge mode Page 2 of 2 FCC ID: 2AGR4-101517 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Radiated Emission below 1GHz-AC adapter charge mode
United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1103 MHz - 0.205 MHz | - |

MAGNETIX RCS RECYCLED PLASTIC 5.000 MAH MAGNETIC POWERBANK - BLACK
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
SAUER-Speaker XIV-BT19
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
AUDEN ALUMINUM WIRELESS SPEAKER-SILVER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
SOUNDPRO WATERPROOF MAGNETIC SPEAKER-BLACK
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Ellis Bluetooth Headphones
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter