FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mobilogix, Inc./
  3. 2AH4HATD700S

2AH4HATD700SThe ATD700S is a solar-powered LTE CAT-M1, IP67 rated mobile asset tracking device with onboard radar sensor for monitoring fill level tanks in agriculture.

Mobilogix, Inc.
The ATD700S is a solar-powered LTE CAT-M1, IP67 rated mobile asset tracking device with onboard radar sensor for monitoring fill level tanks in agriculture. - FCC ID 2AH4HATD700S - Mobilogix, Inc.
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Jul 07, 2021
Application Purpose
Original Equipment
Date of Application
Jul 07, 2021
Equipment Note
The ATD700S is a solar-powered LTE CAT-M1, IP67 rated mobile asset tracking device with onboard radar sensor for monitoring fill level tanks in agriculture.
Frequency Range
779.50000000 - 784.50000000
Company
Mobilogix, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ATD700S USER GUIDE V2021-06-09 V2021-06-09 ATD700S USER GUIDE PG 2 OF 5 5500 TRABUCCO ROAD SUITE 150, IRVINE, CALIFORNIA 92620 P: +1 (949) 748-8895 E: [email protected] © MOBILOGIX, INC. 1 CONTENTS 2 Introduction ....................................................................................................................................................................................... 3 3 Contacts ............................................................................................................................................................................................. 4 4 Disclaimers ......................................................................................................................................................................................... 4 4.1 FCC Interference Statement (Part 15.105 (b)) .......................................................................................................................... 4 4.2 FCC Part 15 Clause 15.21 .......................................................................................................................................................... 4 4.3 FCC Part 15.19(a) [interference compliance statement] .......................................................................................................... 4 4.4 ISED RSS-Gen Notice ................................................................................................................................................................. 5 4.5 FCC RF Exposure Guidance Statement ..................................................................................................................................... 5 4.6 ISED RF Exposure Guidance Statement .................................................................................................................................... 5 5 Version History ................................................................................................................................................................................... 5 V2021-06-09 ATD700S USER GUIDE PG 3 OF 5 5500 TRABUCCO ROAD SUITE 150, IRVINE, CALIFORNIA 92620 P: +1 (949) 748-8895 E: [email protected] © MOBILOGIX, INC. 2 INTROD UCTION The ATD700S is a solar-powered LTE CAT-M1, IP67 rated mobile asset tracking device with onboard radar sensor for monitoring fill level tanks in agriculture. ATD700S is affixed to the top of a tank and will use radar to measure the fluid level. Tank location will be obtained using GNSS. After measuring fluid level and location the data will be sent to a cloud server using cellular air interface connection. Top: Bottom: Product Structure: V2021-06-09 ATD700S USER GUIDE PG 4 OF 5 5500 TRABUCCO ROAD SUITE 150, IRVINE, CALIFORNIA 92620 P: +1 (949) 748-8895 E: [email protected] © MOBILOGIX, INC. 3 CONTACTS • [email protected] • https://mobilogix.com/contact/ 4 D ISCL AIM ERS 4 . 1 F C C I N TE R F E R E N C E S TA TE M E N T ( P A R T 1 5 . 1 0 5 ( B ) ) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 4 . 2 F C C P A R T 1 5 C L A U S E 1 5 . 21 Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 4 . 3 F C C P A R T 1 5 . 1 9 ( A ) [I N TE R F E R E N C E C O M P L I A N C E S TA TE M E N T ] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. V2021-06-09 ATD700S USER GUIDE PG 5 OF 5 5500 TRABUCCO ROAD SUITE 150, IRVINE, CALIFORNIA 92620 P: +1 (949) 748-8895 E: [email protected] © MOBILOGIX, INC. 4 . 4 I S E D R S S-GE N N O TI C E This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage; (2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’encompromettre le fonctionnement. 4 . 5 F C C R F E X P O S U R E G U I D A N C E S T A TE M E N T In order to comply with FCC/ISED RF Exposure requirements, this device must be installed to provide at least 20 cm separation from the human body at all times. 4 . 6 I S E D R F E X P O S U R E G U I D A N C E S T A TE M E N T In order to comply with FCC/ISED RF Exposure requirements, this device must be installed to provide at least 20 cm separation from the human body at all times. Afin de se conformer aux exigences d'exposition RF FCC / ISED, cet appareil do…

Text truncated - open the document above for the full version.

Cover Letter(s)

www.mobilogix.com 5500 Trabuco Road, Suite 150, Irvine, CA 92620 Tel: (949) 748-8895 Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc. Other registered trademarks that appear on this brochure are the property of the respective owners BAND DECLARATION LETTER To Whom It May Concern: Mobilogix, Inc. declare that the following product: Product: ATD700S Brand: Mobilogix, Inc. Model Number: ATD700S integrates the Cellular module: Product Name: BG95-M3 Brand: Quectel Model Number: BG95M3LA-64-SGNS FCC ID: XMR201910BG95M3 with the following bands disabled: • GSM 850/1900 • LTE Band 12 • LTE Band 25 • LTE Band 26 • LTE Band 66 • LTE Band 85 • NB-IoT (All Bands) Please do not hesitate to contact the undersigned should you require additional information or have any questions regarding this declaration. Signed for and on behalf of: Mobilogix, Inc. Name (print): Ramy Mourad Title: VP - R&D Date: www.mobilogix.com 5500 Trabuco Road, Suite 150, Irvine, CA 92620 Tel: (949) 748-8895 Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc. Other registered trademarks that appear on this brochure are the property of the respective owners Signature:

Cover Letter(s)

5500 TRABUCCO ROAD SUITE 150, IRVINE, CALIFORNIA 92620 P: +1 (949) 748-8895 E: [email protected] © MOBILOGIX, INC. www.mobilogix.com LETTER OF AUTHORIZATION This letter certifies that Mobilogix, Inc. has engaged the services of GMA LABS LLC to assist in filing applications for regulatory approvals on our behalf for the following product: Trademark / Brand: Mobilogix, Inc. Product Name: ATD700 Model Name: ATD700 Please direct any correspondence with Mobilogix Inc. in all matters relating to the applications for regulatory approvals to GMA LABS LLC. Thank you for your assistance in obtaining the corresponding certifications. Signed for and on behalf of: MOBILOGIX, INC Name (print): Ramy Mourad Title: VP - R&D Date: June 9, 2021 Signature:

Cover Letter(s)

www.mobilogix.com 5500 Trabuco Road, Suite 150, Irvine, CA 92620 Tel: (949) 748-8895 Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc. Other registered trademarks that appear on this brochure are the property of the respective owners MODULE DECLARATION LETTER To Whom It May Concern: Mobilogix, Inc. declare that the following product: Product: ATD700S Brand: Mobilogix, Inc. Model Number: ATD700S integrates the Cellular module: Product Name: BG95-M3 Brand: Quectel Model Number: BG95M3LA-64-SGNS FCC ID: XMR201910BG95M3 And integrates the Radar module: Product Name: AD111 Brand: Acconeer Model Number: A111-001-T&R FCC ID: 2AQ6KA1001 ATD700S integrates BG95-M3 and AD111 without deviations from the modules as certified. Please do not hesitate to contact the undersigned should you require additional information or have any questions regarding this declaration. Signed for and on behalf of: Mobilogix, Inc. Name (print): Ramy Mourad Title: VP - R&D Date: www.mobilogix.com 5500 Trabuco Road, Suite 150, Irvine, CA 92620 Tel: (949) 748-8895 Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc. Other registered trademarks that appear on this brochure are the property of the respective owners Signature:

Cover Letter(s)

6/17/2021 Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (ATD700S/FCC ID: 2AH4HATD700S) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Block Diagram, Schematics, Parts List, Tune Up procedure, Operational Description ) required to be submitted with this application be permanently withheld from public review. the above documents are company proprietary information that could never get into the possession of your competition Please contact me if there is any information you may need. Sincerely, Amir Tavakoli Director of Compliance 2021-6-17

Cover Letter(s)

(18/06/2021) Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: Short Term Confidentiality Request For (ATD700S/FCC ID: 2AH4HATD700S) To Whom It May Concern: In accordance with sections 0.457 and 0.459 of CFR 47, Mobilogix, Inc requests short- term Confidentiality of following sections of this application for a period of 180 days after grant is issued. Test setup photos External photos Internal photos User’s manual These documents contain detailed system and equipment descriptions and related information about the product, which Mobilogix, Inc considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, Mobilogix, Inc feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Amir Tavakoli Director of Compliance 2021-06-18

ID Label/Location Info

106.0mm 119.5mm LEDs Button Humidity sensor vent Light sensor window USB Texture MT11005 Polished ATD700 NICK A0 2020-05-12 PROJECT: DRAWN BY: REVISE DESCRIPTION DATE Pantone 151C ****** Power Status Power Status Po wer Stat us A1 Add LED silkscreen 2020-05-19 Global Asset Tracker Contains 4000 mAh Li-po battery. Battery must be recycled or disposed of properly. ATTENTION : OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES Manufacturer: Mobilogix , Inc. Country of origin: China Date Code: 07/10/2020 VZGAT-CM1-001 IMEI : 123456789012345 S/N:A210S200100000S ICC ID : 12345678901234567890 ATD 210S HVIN:1.0 IC IC: 21385-VZGATCM1 FCC ID :2AH4HVZGATCM1 A2 Update the label view 2020-08-25 106.0mm (41.0mm) Solar panel: 80*80mm

RF Exposure Info

HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Report: WIRS113210-RF Exposure © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 1 of 5 Maryland | California | Texas www.metlabs.com DOC-WIR TEMP-18 (22H-24E) 4-28-2021 – Rev. 0 - Approved by DOC Manager RF Exposure Report Status Sheet Revision Report Date Reason for Revision Ø June 16, 2021 Initial Issue. HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Report: WIRS113210-RF Exposure © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 2 of 5 Maryland | California | Texas www.metlabs.com DOC-WIR TEMP-18 (22H-24E) 4-28-2021 – Rev. 0 - Approved by DOC Manager Electromagnetic Compatibility Emission Criteria RF Exposure Evaluation of Devices RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. RF Exposure Limits S = PG / 4R 2 or R = √(PG / 4S) where, S = Power Density (mW/cm 2 ) P = Power Input to antenna (mW) G = Antenna Gain (numeric value) R = Distance (cm) For Antenna Gain → dBi = 10log(Numeric) HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Report: WIRS113210-RF Exposure © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 3 of 5 Maryland | California | Texas www.metlabs.com DOC-WIR TEMP-18 (22H-24E) 4-28-2021 – Rev. 0 - Approved by DOC Manager Technology TX Frequency Range Peak Gain Type LTE CAT-M1 Band 2 1850 – 1910 MHz 4.3 dBi FPC Embedded Antenna LTE CAT-M1 Band 4 1710 – 1755 MHz 4.3 dBi FPC Embedded Antenna LTE CAT-M1 Band 5 814 – 849 MHz 2.9 dBi FPC Embedded Antenna LTE CAT-M1 Band 13 777 – 787 MHz 2.9 dBi FPC Embedded Antenna Table 1.. EUT Antenna Gain Specifications Technology TX Frequency Range Maximum Conducted Output Power LTE CAT-M1 Band 2 1850 – 1910 MHz 22 (-3 ~ +1dB) = 23.0 dBm LTE CAT-M1 Band 4 1710 – 1755 MHz 22 (-3 ~ +1dB) = 23.0 dBm LTE CAT-M1 Band 5 814 – 849 MHz 22 (-3 ~ +1dB) = 23.0 dBm LTE CAT-M1 Band 13 777 – 787 MHz 22 (-3 ~ +1dB) = 23.0 dBm Table 2. Tune up Power Test Results: Band Frequency (MHz) Maximum Conducted Power (dBm) Conducted Power (mW) Antenna Gain (dBi) Antenna Gain (Numeric) Power Density (mW/cm2) Limit (mW/cm2) Margin Distance (cm) Result LTE Band 2 1850 23 199.53 4.3 2.692 0.107 1 0.893 20 Pass LTE Band 4 1710 23 199.53 4.3 2.692 0.107 1 0.893 20 Pass LTE Band 5 814 23 199.53 2.9 1.950 0.077 0.543 0.465 20 Pass LTE Band 13 777 23 199.53 2.9 1.950 0.077 0.518 0.441 20 Pass Table 3. MPE Calculation for Cellular Bands The safe distance where Power Density is less than the MPE limit listed above was found to be 20 cm. FCC Frequency (MHz) 57000 71000 PG Declared Max Power (EIRP) -2.1 -2.1 dBm R Distance 20 20 cm S MPE limit for uncontrolled exposure 1 1 mW/cm2 Calculated Power Density 0.0001 0.0001 mW/cm2 Table 4. MPE Calculation for Radar The safe distance where Power Density is less than the MPE limit listed above was found to be 20 cm. HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Report: WIRS113210-RF Exposure © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 4 of 5 Maryland | California | Texas www.metlabs.com DOC-WIR TEMP-18 (22H-24E) 4-28-2021 – Rev. 0 - Approved by DOC Manager Note: Results are based on KDB 447498 D01 (Section 7.2) Transmitters used in mobile devices exposure conditions for simultaneous transmission operations. Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneously transmitting antennas incorporated in a host device is ≤ 1.0, according to calculated/estimated, numerically modeled, or measured field strengths or power density. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to the MPE limit at the test frequency. Cellular and Radar radios can transmit simultaneously. T the formula for calculating the simultaneous MPE is CPD1/LPD1 + CPD2/LPD2 + ,,,, CPDn/LPDn < 1 CPD: Calculated Power Density LPD: Limit of Power Density Simultaneous MPE = Cellular + Radar = 0.077/0.518 + 0.0001/1 = 0.148 + 0.0001 = 0.1481 Result: 0.1481 < 1 (Pass) HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Report: WIRS113210-RF Exposure © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 5 of 5 Maryland | California | Texas www.metlabs.com DOC-WIR TEMP-18 (22H-24E) 4-28-2021 – Rev. 0 - Approved by DOC Manager END OF REPORT

Test Report

HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Maryland | California | Texas www.metlabs.com July 1, 2021 Mobilogix, Inc. 5500 Trabuco Rd, Suite 150 Irvine, California 92620 Dear Ramy Mourad, Enclosed is the EMC Wireless test report for compliance testing of the Mobilogix, Inc., ATD700S as tested to the requirements of the FCC Certification rules under Title 47 of the CFR Part 22 Subpart H for Cellular Devices and FCC Part 24 Subpart E for Broadband PCS Devices and Title 47 of the CFR Part 27 Subpart L for Broadband Radio Service (BRS). Thank you for using the services of Eurofins Electrical and Electronic Testing NA, Inc. If you have any questions regarding these results or if we can be of further service to you, please contact me. Sincerely yours, Rheine Nguyen Documentation Department Eurofins Electrical and Electronic Testing NA, Inc. Reference: (\Mobilogix, Inc.\WIRS113210-FCC22_24_27) Certificates and reports shall not be reproduced except in full, without the written permission of Eurofins E&E North America. While use of the A2LA logo in this report reflects MET accreditation under these programs, the report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the Federal Government. This letter of transmittal is not a part of the attached report. Eurofins MET Laboratories Inc. (Eurofins E&E North America) is part of the Eurofins Electrical & Electronics (E&E) global compliance network. HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Report: WIRS113210-FCC22_24_27 © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page ii of viii Electromagnetic Compatibility Criteria Test Report for the Mobilogix, Inc. ATD700S Tested under FCC Certification Rules Title 47 of the CFR, Part 22 Subpart H for Cellular Devices Part 24 Subpart E for Broadband PCS Devices Part 27 Subpart L for Broadband Radio Service (BRS) Devices Report: WIRS113210-FCC22_24_27 Prepared For: Mobilogix, Inc. 5500 Trabuco Rd, Suite 150 Irvine, California 92620 Prepared By: Eurofins Electrical and Electronic Testing NA, Inc. 3162 Belick St., Santa Clara, CA 95054 Mobilogix, Inc. Electromagnetic Compatibility ATD700S CFR Title 47 Part 22 H & Part 24 E & Part 27 L Report: WIRS113210-FCC22_24_27 © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page iii of viii Electromagnetic Compatibility Criteria Test Report for the Mobilogix, Inc. ATD700S Tested Under FCC Certification Rules Title 47 of the CFR, Part 22 Subpart H for Cellular Devices Part 24 Subpart E for Broadband PCS Devices Part 27 Subpart L for Broadband Radio Service (BRS) Devices Arsalan Hasan Project Engineer, Electromagnetic Compatibility Lab Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of Part 22 Subpart H and Part 24 Subpart E and Part 27 Subpart L of the FCC Rules under normal use and maintenance. Eleazar Zuniga, Director, Wireless Laboratory Mobilogix, Inc. Electromagnetic Compatibility ATD700S CFR Title 47 Part 22 H & Part 24 E & Part 27 L Report: WIRS113210-FCC22_24_27 © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page iv of viii Report Status Sheet Revision Report Date Reason for Revision  July 1, 2021 Initial Issue. Mobilogix, Inc. Electromagnetic Compatibility ATD700S CFR Title 47 Part 22 H & Part 24 E & Part 27 L Report: WIRS113210-FCC22_24_27 © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page v of viii Table of Contents I. Executive Summary ................................................................................................................................................. 1 A. Purpose of Test ................................................................................................................................................... 2 B. Executive Summary ............................................................................................................................................ 2 II. Equipment Configuration ....................................................................................................................................... 3 A. Overview ............................................................................................................................................................. 4 B. References ........................................................................................................................................................... 5 C. Test Site .............................................................................................................................................................. 5 D. Measurement Uncertainty ................................................................................................................................... 5 E. Description of Test Sample ................................................................................................................................. 6 F. Modifications ...................................................................................................................................................... 7 Modifications to EUT .................................................................................................................................. 7 Modifications to Test Standard .................................................................................................................... 7 G. Disposition of EUT …

Text truncated - open the document above for the full version.

Test Setup Photos

HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Maryland | California | Texas www.metlabs.com Report: WIRS113210-Appendix A © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 1 of 11 APPENDIX A WIRS103210 Test Setup Photos HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Maryland | California | Texas www.metlabs.com Report: WIRS113210-Appendix A © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 2 of 11 Figure 1: Radiated Spurious Emissions, 30MHz-1GHz, Test Setup HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Maryland | California | Texas www.metlabs.com Report: WIRS113210-Appendix A © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 3 of 11 Figure 2: Radiated Spurious Emissions, 1GHz-18GHz, Test Setup HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Maryland | California | Texas www.metlabs.com Report: WIRS113210-Appendix A © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 4 of 11 Figure 3: Substitution Method, Below 1GHz, Test Setup HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Maryland | California | Texas www.metlabs.com Report: WIRS113210-Appendix A © 2021, Eurofins Electrical and Electronic Testing NA, Inc. Page 5 of 11 Figure 4: Substitution Method, Above 1GHz, Test Setup

Test Setup Photos

Mobilogix, Inc. Setup Photos ATD700S CFR Title 47 Part 1 Report: WIRS113210‐FCC Setup Photos © 2021, Eurofins Electrical and Electronics Testing NA, Inc. Page 1 of 5 Setup Photos Revision Report Date Reason for Revision  July 1, 2021 Initial Issue. Mobilogix, Inc. Setup Photos ATD700S CFR Title 47 Part 1 Report: WIRS113210‐FCC Setup Photos © 2021, Eurofins Electrical and Electronics Testing NA, Inc. Page 2 of 5 Radiated Spurious Emissions, 1GHz – 18GHz, Test Setup Mobilogix, Inc. Setup Photos ATD700S CFR Title 47 Part 1 Report: WIRS113210‐FCC Setup Photos © 2021, Eurofins Electrical and Electronics Testing NA, Inc. Page 3 of 5 Substitution Method, Test Setup Mobilogix, Inc. Setup Photos ATD700S CFR Title 47 Part 1 Report: WIRS113210‐FCC Setup Photos © 2021, Eurofins Electrical and Electronics Testing NA, Inc. Page 4 of 5 30MHz – 1GHz, Part15B Test Setup Mobilogix, Inc. Setup Photos ATD700S CFR Title 47 Part 1 Report: WIRS113210‐FCC Setup Photos © 2021, Eurofins Electrical and Electronics Testing NA, Inc. Page 5 of 5 Conducted Power Measurement Test Setup

Contact Information

Applicant

Ramy Mourad(VP IoT Solutions R&D)
[email protected]9499103095Fax: 949-396-2133

Technical Contact

Mobilogix, Inc.Ramy Mourad
[email protected]949-748-8895

5500 Trabuco Rd · Irvine, California · United States

Non-Technical Contact

GMA LABSAmir Tavakoli
[email protected]949-356-0700

Test Firm

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INCGreg Kovolenko
[email protected]4108444071Fax: 4439299462

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
827779.5 MHz - 784.5 MHz113.00 mW963KW7D0.00887 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.

Other Applications from Mobilogix, Inc.

LTE Cat-M1 Tracker - FCC ID 2AH4HATD521 - Mobilogix, Inc.
2AH4HATD521

LTE Cat-M1 Tracker

Nov 23, 2022

Equipment Class

PCB - PCS Licensed Transmitter
The ATD500Y is an asset tracker equipped with LTE CatM1, quad-band 2G, Bluetooth, GNSS, environmental, and IMU sensors. The BAT-X may be in one of three operating modes - FCC ID 2AH4HATD500Y - Mobilogix, Inc.
2AH4HATD500Y

The ATD500Y is an asset tracker equipped with LTE CatM1, quad-band 2G, Bluetooth, GNSS, environmental, and IMU sensors. The BAT-X may be in one of three operating modes

Jul 25, 2021

Equipment Class

DTS - Digital Transmission System
ATD310B is a Wireless Headlight Controller (WHC) multi-functional device with Cellular, Bluetooth, and NFC communications interfaces - FCC ID 2AH4HATD310B - Mobilogix, Inc.
2AH4HATD310B

ATD310B is a Wireless Headlight Controller (WHC) multi-functional device with Cellular, Bluetooth, and NFC communications interfaces

Nov 16, 2020

Equipment Class

DTS - Digital Transmission System
GLOBAL ASSET TRACKER - FCC ID 2AH4HVZGATCM1 - Mobilogix, Inc.
2AH4HVZGATCM1

GLOBAL ASSET TRACKER

Jul 14, 2020

Equipment Class

PCB - PCS Licensed Transmitter
LTE Asset Tracker with GSM WLAN RX and BLE - FCC ID 2AH4HATD500X - Mobilogix, Inc.
2AH4HATD500X

LTE Asset Tracker with GSM WLAN RX and BLE

Jul 07, 2020

Equipment Class

DTS - Digital Transmission System