FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. AoFrio Limited/
  3. 2AHCE-SCS2

2AHCE-SCS2Cellular Connected Controller

AoFrio Limited

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 26, 2026
Application Purpose
Original Equipment
Equipment Note
Cellular Connected Controller
Frequency Range
2402.00000000 - 2480.00000000
Company
AoFrio Limited
Country
New Zealand

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: FRN: Contact Name: Susan E Sieben Street Address: 229 Lewis Ave City/Province/Zip: Wauconda, IL 60084 Telephone No: 847-922-5098 Email: [email protected] Signature: Signed by (Printed Name/Title): Susan E Sieben acknowledges their obligation to accept service of process on behalf of AoFrio Ltd. Please note that Susan E Sieben does not do business with the Federal Communications Commission and therefore does not hold an FRN. This letter is to confirm that Susan E Sieben (“the Designated U.S. Agent) has accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: AoFrio Ltd. FRN: 0025225822 Grantee Code: 2AHCE FCC ID: 2AHCE-SCS2 Contact Name: Marc Tinsel Address: 78 Apollo Drive, Rosedale, Auckland 0632, New Zealand Telephone No: +64 27 839 5679 Email: [email protected] Signature: Date: 2026-02-17 Signed by (Printed Name/Title): Marc Tinsel, EVP Operations

Attestation Statements

Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 18 Feb 2026 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2AHCE-SCS2 [AoFrio Limited] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Marc Tinsel Title: EVP Operations Address: 78 Apollo Drive, Rosedale, Auckland, New Zealand Tel.: +64 27 839 5679 Email: [email protected]

Attestation Statements

Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 18 Feb 2026 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2AHCE-SCS2 [AoFrio Limited] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Marc Tinsel Title: EVP Operations Address: 78 Apollo Drive, Rosedale, Auckland, New Zealand Tel.: +64 27 839 5679 Email: [email protected]

Cover Letter(s)

www.aofrio.com P: + 64 9 477 4500 E: [email protected] ® is a registered Trademark of AoFrio Ltd A: 78 Apollo Drive, Rosedale, Auckland 0632, New Zealand PO Box: 302-533 North Harbour, Auckland 0751, New Zealand Authority to Act as Agent Date: 18 Feb 2026 TÜV Rheinland Group 762 Park Avenue Youngsville, NC 27596 To Whom It May Concern: I appoint TÜV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TÜV Rheinland Group, still resides with AoFrio Limited / 78 Apollo Drive, Rosedale, Auckland, New Zealand. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: _____12 months_____ By: Marc Tinsel (Signature) Title: EVP Operation Telephone: +64 27 839 5679 On behalf of: AoFrio Limited

Cover Letter(s)

Page 1 of 1 uncontrolled when printed out TCB FCC Request for Confidentiality Letter Date: 18 Feb 2026 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2AHCE-SCS2 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Construction AoFrio Limited has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: ___ _ Marc Tinsel_/ EVP Operation _ (Signature) (Print name/Title) Tel: +64 27 839 5679 Email: [email protected]

ID Label/Location Info

Label and Label Loca on SCS 800  Product Label  FCC Rule Label

RF Exposure Info

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26ZFDO 003 Auftrags-Nr.: Order no.: 168575881 Seite 1 von 11 Page 1 of 11 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-09-22 Auftraggeber: Client: AoFrio Ltd. 78 Apollo Drive, Rosedale, Auckland 0632, New Zealand Prüfgegenstand: Test item: Cellular Connected Controller Bezeichnung / Typ-Nr.: Identification / Type no.: SCS 800 (Trademark: ) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 1.1310 CFR Title 47 FCC Part 2.1091 RSS-102 Issue 6 December 2023 Wareneingangsdatum: Date of sample receipt: 2025-12-16 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004163921-001~004 Prüfzeitraum: Testing period: 2025-12-16 - 2026-01-22 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2026-01-29 Ausstellungsdatum: Issue date: 2026-01-29 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2AHCE-SCS2 IC: 21145-SCS2 HVIN: SCS 800 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 17-18F, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P. R. China Mail: [email protected] · Web: www.tuv.com V101023GCNSR Hardy Suo Lin Lin Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26ZFDO 003 Test report no.: Seite 2 von 11 Page 2 of 11 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statem…

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 23 of 52 (Reference Level) Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 24 of 52 Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 25 of 52 Bluetooth LE, 2Mbps (Reference Level) Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 26 of 52 (Reference Level) Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 27 of 52 (Reference Level) Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 28 of 52 Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 29 of 52 Appendix A.5: Test Results of Radiated Spurious Emissions Note: 1) This testing was carried out on different modulations, but only the worst case was presented in this report. 2) Testing was carried out within frequency range 9kHz to the tenth harmonics. The measurement results below 30MHz and 18GHz - 26.5GHz were greater than 20dB below the limit, so only the radiated spurious emissions from 30MHz to 18GHz were reported. 30MHz - 1GHz EUT Information EUT Name: Cellular Connected Controller Model: SCS 800 Test Mode: BLE 1M_Mid channel Order No/Sample No: 168575881/A004163921-002 Test Voltage:: AC 120V/60Hz Remark: Temp 22 Humi:55% Test Standard: FCC 15.247 Tested By: Kei Zhang Reviewed By: Terry Yin 0 10 20 30 40 50 60 30M 50 60 80 100M200300 400 500 800 1G Level in dB 礦 /m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) 41.208889 20.90 40.00 19.10 100.0 H 207.0 -19.9 77.314444 32.73 40.00 7.27 100.0 H 254.0 -23.5 136.053333 29.36 43.50 14.14 100.0 H 38.0 -22.2 214.407778 20.59 43.50 22.91 100.0 H 287.0 -18.8 272.985000 21.17 46.00 24.83 100.0 H 302.0 -16.9 742.518889 24.76 46.00 21.24 100.0 H 0.0 -7.2 936.950000 26.41 46.00 19.59 100.0 H 137.0 -4.4 Final_Result Frequency (MHz) QuasiPeak (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) --- --- --- --- --- --- --- Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 30 of 52 EUT Information EUT Name: Cellular Connected Controller Model: SCS 800 Test Mode: BLE 1M_Mid channel Order No/Sample No: 168575881/A004163921-002 Test Voltage:: AC 120V/60Hz Remark: Temp 22 Humi:55% Test Standard: FCC 15.247 Tested By: Kei Zhang Reviewed By: Terry Yin 0 10 20 30 40 50 60 30M 50 60 80 100M200300 400 500 800 1G Level in dB 礦 /m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) 30.646667 34.61 40.00 5.39 100.0 V 150.0 -22.9 38.029444 32.51 40.00 7.49 100.0 V 165.0 -20.8 80.978889 24.47 40.00 15.53 100.0 V 285.0 -23.4 274.224444 15.73 46.00 30.27 100.0 V 62.0 -16.9 502.066667 18.17 46.00 27.83 100.0 V 359.0 -11.8 805.676667 24.82 46.00 21.18 100.0 V 338.0 -6.1 936.950000 27.57 46.00 18.43 100.0 V 105.0 -4.4 Final_Result Frequency (MHz) QuasiPeak (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) --- --- --- --- --- --- --- Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 31 of 52 1GHz - 18GHz Note: The highest waveform in the figure is Bluetooth LE Fundamental. EUT Information EUT Name: Cellular Connected Controller Model: SCS 800 Test Mode: BLE 1M_Low channel Order No/Sample No: 168575881/A004163921-002 Test Voltage:: AC 120V/60Hz Remark: Temp 22 Humi:55% Test Standard: FCC 15.247 Tested By: Kei Zhang Reviewed By: Terry Yin 0 20 40 60 80 100 120 130 1G2G3G4G5G 6.2G Level in dB 礦 /m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak (dBμV/m) Average (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) 2489.500000 --- 49.06 54.00 4.94 150.0 H 102.0 9.0 2505.500000 54.51 --- 68.20 13.69 150.0 H 89.0 9.1 4811.000000 --- 41.66 54.00 12.34 150.0 H 346.0 13.3 4812.500000 52.81 --- 74.00 21.19 150.0 H 359.0 13.3 Final_Result Frequency (MHz) MaxPeak (dBμV/m) Average (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) --- --- --- --- --- --- --- --- Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 32 of 52 EUT Information EUT Name: Cellular Connected Controller Model: SCS 800 Test Mode: BLE 1M_Low channel Order No/Sample No: 168575881/A004163921-002 Test Voltage:: AC 120V/60Hz Remark: Temp 22 Humi:55% Test Standard: FCC 15.247 Tested By: Kei Zhang Reviewed By: Terry Yin 0 20 40 60 80 100 120 130 1G2G3G4G5G 6.2G Level in dB 礦 /m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak (dBμV/m) Average (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) 4801.500000 --- 41.93 54.00 12.07 150.0 V 237.0 13.3 4806.000000 52.60 --- 74.00 21.40 150.0 V 188.0 13.3 Final_Result Frequency (MHz) MaxPeak (dBμV/m) Average (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) --- --- --- --- --- --- --- --- Prüfbericht - Produkte Test Report - Products Appendix A CN26ZFDO 002 Page 33 of 52 EUT Information EUT Name: Cellular Connected Controller Model: SCS 800 Test Mode: BLE 1M_Low channel Order No/Sample No: 168575881/A004163921-002 Test Voltage:: AC 120V/60Hz Remark: Temp 22 Humi:55% Test Standard: FCC 15.247 Tested By: Kei Zhang Reviewed By: Terry Yin 0 20 40 60 80 100 6.2G 8910G18G Level in dB 礦 /m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak (dBμV/m) Average (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) 7206.441667 50.33 --- 74.00 23.67 150.0 H 241.0 8.8 7206.441667 --- 47.33 54.00 6.67 150.0 H 241.0 8.8 9606.758333 --- 38.19 54.00 15.81 150.0 H 345.0 10.4 9608.233333 44.79 --- 74.00 29.21 150.0 H 323.0 10.4 12146.216667 50.95 --- 74.00 23.05 150.0 H 0.0 16.6 12150.641667 --- 42.24 54.00 11.76 150.0 H 130.0 16.7 Final_Result Frequency (MHz) MaxPeak (dBμV/m) Average (dBμV/m) Limit (dBμV/m) Margin (dB) Height (cm) Pol Azimuth (deg) Corr. (dB/m) --- --- --- --- --- ---…

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26ZFDO 002 Auftrags-Nr.: Order no.: 168575881 Seite 1 von 23 Page 1 of 23 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-09-22 Auftraggeber: Client: AoFrio Ltd. 78 Apollo Drive, Rosedale, Auckland 0632, New Zealand Prüfgegenstand: Test item: Cellular Connected Controller Bezeichnung / Typ-Nr.: Identification / Type no.: SCS 800 (Trademark: ) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 15.247 CFR Title 47 FCC Part 22 CFR Title 47 FCC Part 24 CFR Title 47 FCC Part 27 CFR Title 47 FCC Part 90 RSS-247 Issue 4 RSS-130 Issue 2 RSS-132 Issue 3 RSS-133 Issue 6 RSS-139 Issue 3 Wareneingangsdatum: Date of sample receipt: 2025-12-16 Refer to photos documents Prüfmuster-Nr.: Test sample no: A004163921-001~004 Prüfzeitraum: Testing period: 2025-12-16 - 2026-01-22 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2026-01-29 Ausstellungsdatum: Issue date: 2026-01-29 Stellung / Position Sachverständige(r)/Expert Stellung / Position Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2AHCE-SCS2 IC: 21145-SCS2 HVIN: SCS 800 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This only relates to the a. m. test sample. Without permission of the test center this is not permitted to be duplicated in extracts. This does not entitle to carry any test mark. TÜV Rheinland (Shenzhen) Co., Ltd. 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518000, China Mail: [email protected] · Web: www.tuv.com V101023GCNSR Hardy Suo Lin Lin Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26ZFDO 002 Test report no.: Seite 2 von 23 Page 2 of 23 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request.p 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurement results, in this is based on the “Zero Guard Band Rule” and “Simple Acceptance” in accordance with ILAC G8:2019 and IEC Guide 115:2021, unless othe…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 16 ANT Gain SCS 800 AoFrio Ltd. 78 Apollo Drive, Rosedale, Auckland 0632, New Zealand Page 2 of 16  Bluetooth LE ANT (PCB ANT)  Frequency Range: 2400-2500 MHz  Max Gain: 1.56 dBi Frequency (MHz) Efficiency (dB) Efficiency (%) Peak Gain (dBi) 2400.00 -2.73 53.31 1.18 2402.00 -2.72 53.50 1.19 2405.00 -2.74 53.16 1.17 2410.00 -2.39 57.69 1.47 2415.00 -2.57 55.38 1.31 2420.00 -2.43 57.09 1.37 2425.00 -2.58 55.18 1.27 2430.00 -2.49 56.38 1.40 2435.00 -2.50 56.22 1.38 2440.00 -2.26 59.37 1.52 2441.00 -2.20 60.22 1.56 2445.00 -2.20 60.25 1.47 2450.00 -2.30 58.91 1.34 2455.00 -2.33 58.42 1.20 2460.00 -2.45 56.83 1.02 2465.00 -2.73 53.33 0.79 2470.00 -2.89 51.39 0.62 2475.00 -2.94 50.84 0.71 2480.00 -3.17 48.20 0.60 2485.00 -3.36 46.14 0.45 2490.00 -3.61 43.57 0.28 2495.00 -3.59 43.74 0.32 2500.00 -4.02 39.64 0.03 Page 3 of 16  2D Pa0ern Cuts Plot _ XY Plane -26 -22 -18 -14 -10 -6 -2 2 6 0 30 60 90 120 150 180 210 240 270 300 330 2402.000 MHz [dB]2440.000 MHz [dB]2480.000 MHz [dB] Page 4 of 16 Cuts Plot _ YZ Plane -26 -22 -18 -14 -10 -6 -2 2 6 0 30 60 90 120 150 180 210 240 270 300 330 2402.000 MHz [dB]2440.000 MHz [dB]2480.000 MHz [dB] Page 5 of 16 Cuts Plot _ XZ Plane -26 -22 -18 -14 -10 -6 -2 2 6 0 30 60 90 120 150 180 210 240 270 300 330 2402.000 MHz [dB]2440.000 MHz [dB]2480.000 MHz [dB] Page 6 of 16  3D Pa0ern Free Space_2402MHz Page 7 of 16 Free Space_2440MHz Page 8 of 16 Free Space_2480MHz Page 10 of 16  2.4G Wi-Fi ANT (FC41D PCB Antenna) Page 11 of 16 Page 12 of 16 Page 13 of 16  LTE ANT Page 14 of 16 Page 15 of 16 Page 16 of 16

Contact Information

Applicant

Marc Tinsel(Executive Vice-President Operations)
[email protected]Fax: +6494795540

Technical Contact

AoFrio Ltd.Susan E Sieben
[email protected]

229 Lewis Ave · Illinois, 60084 · United States

Test Firm

TUV Rheinland (Shenzhen) Co., Ltd.Gina Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.30 mW
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures as evaluated in this filing. End user must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from AoFrio Limited

Gateway - FCC ID 2AHCE-GW2 - AoFrio Limited
2AHCE-GW2

Gateway

Nov 28, 2025

Equipment Class

DTS - Digital Transmission System
Connect Monitor - FCC ID 2AHCE-MON1 - Wellington Drive Technologies Ltd
2AHCE-MON1

Connect Monitor

Nov 23, 2020

Equipment Class

DTS - Digital Transmission System