
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
DONGGUANARUNINDUSTRIALCO.,LTD CERTIFICATIONSCONCERNING“COVERED”EQUIPMENT Date:March28,2023 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,Maryland21046 FCCID:2AHCL-STORM300 ToWhomItMayConcern: Asrequiredbysection 2.911(d)(5)(i), [DONGGUANARUNINDUSTRIALCO.,LTD](“the applicant”)certifiesthattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903 oftheFCCrules. Asrequiredbysection2.911(d)(5)(ii),[DONGGUANARUNINDUSTRIALCO.,LTD](“the applicant”)certifiesthat,asofthedateofthefilingoftheapplication,theapplicantisnot identifiedontheCoveredListasanentityproducing“covered”equipment. Thankyouforyourattentiontothismatter. Sincerelyyours, Signature: PrintedName:SimonXiao JobTitle:Manager Company:DONGGUANARUNINDUSTRIALCO.,LTD Email:[email protected] Telephone:13528413249
DONGGUANARUNINDUSTRIALCO.,LTD DifferenceDescription Date : March28,2023 Productname:PowerStation FCCID:2AHCL-STORM300 Modellist: STORM300B01US,STORM300BXXYY,”YY”=blankorstandsforthealphabetfromAtoZ, ”XX”blankorstandsfortheArabicnumerals,whicharetheabbreviationofdifferentcolor,market,version,etc TheschematicdiagramandPCBofallmodelsareidentical,onlythemodelnameandappearancecoloraredifferent. Signature: PrintedName:SimonXiao JobTitle:Manager Company:DONGGUANARUNINDUSTRIALCO.,LTD Email:[email protected] Telephone:13528413249
DONGGUANARUNINDUSTRIALCO.,LTD LETTEROFAGENCY Date:March28,2023 ElementMaterialsTechnology 100FrobisherBusinessPark Malvern Worcestershire WR141BX UK FCCID:2AHCL-STORM300 ToWhomItMayConcern: Wecertifythatwearenotsubjecttodenialoffederalbenefits,thatincludesFCCbenefits, pursuanttoSection5301oftheAnti-DrugAbuseACTof1988,U.S.C.862.Further,no party,asdefinedin47CFR1.2002(b),totheapplication,issubjecttodenialoffederal benefits,thatincludesFCCbenefits. Thankyouforyourattentiontothismatter. Yoursfaithfully company Signature PrintedName:SimonXiao JobTitle:Manager Company:DONGGUANARUNINDUSTRIALCO.,LTD Email:[email protected] Telephone:13528413249
ConfidentialityLetter-FCC Date: March28,2023 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,Maryland21046 Re:Requestforconfidentiality FCCID:2AHCL-STORM300 Towhomitmayconcern, Weherebyrespectfullyrequestthatundertheprovisionof47CFR0.459and0.457(d)the documentslistedbelowandattachedwiththisapplicationforcertificationbeprovidedwith confidentialstatus. Schematics.pdf OperationalDescription.pdf FrequencyBlockDiagrams.pdf Anyexhibit/informationforwhichwehaverequestedconfidentiality,butwhichmaynotbe accordedsuchtreatmentbytheFCC,shouldbereturnedtous. Thedocumentslistedabovecontaintradesecretsthataretreatedasconfidentialbyus. Substantialcompetitiveharmtouscouldresultshouldtheybemadeavailabletothepublic. Sincerely, Signature PrintedName:SimonXiao JobTitle:Manager Company:DONGGUANARUNINDUSTRIALCO.,LTD Email:[email protected] Telephone:13528413249
FCCID:2AHCL-STORM300 Page1/5 Externalphoto FCCID:2AHCL-STORM300 Page2/5 FCCID:2AHCL-STORM300 Page3/5 FCCID:2AHCL-STORM300 Page4/5 ADAPTER1 ADAPTER1 FCCID:2AHCL-STORM300 Page5/5 ---END--- ADAPTER2 ADAPTER2
LABLELocation LABLELocation
技术要求 1、尺寸: 75x37*R5(4x)±0.5mm 2、材料: 54#珠光合成纸/表面过哑膜 3、印刷: 黑底白字 铭牌贴 初版发行 A0 A1 A0 2023/03/282023/03/30 陈财 2023/03/28 陈财 USB-A2 Output: 5V 2.4A Type-C1 PD3.0 Output: 5V-9V 3A,12V 2.5A USB-A1 QC3.0 Output: 5V 3A,9V 2A,12V 1.5A Product Name: Power Station Type-C2 PD3.0 Output: 5V-9V 3A,12V 2.5A Manufacturer: Dongguan Arun Industrial Co.,Ltd. Address: No.13,Xinfeng st.,Changlong,Huangjiang,Dongguan,Guangdong DC Input: 24V 2A, 48W Total Output Power: 400W Battery Capacity: 14.8Vdc,20Ah,296Wh AC Output: AC 110V 60Hz,Rated Power: 300W DC 5521 Output: 12V 5A Charging Temperature Of Cells: 0 °C ~ 45 °C Car Charge and DC Output: 12V 8A,96W Max. Wireless Output: 10W Max. Total DC Output: 186W Max. Model No.: STORM 300B 01US Working Environment Temperature: -10°C ~ 40°C FCC ID: 2AHCL-STORM300 XXXX Solar Input:12-28V,100W Max. R3mm 技术要求 1、尺寸: 75x37*R3(4x)±0.25mm 2、材料: 珠光合成纸 表面过哑膜 3、印刷: 黑底白字 放大图 FCC警告贴纸 初版发行 A0 A0 2023/01/042023/01/08 张烨 2022/12/30 张烨 Warning (1)Thisdevicemaynotcauseharmfulinterference,and ThisdevicecomplieswithPart15ofFCCrules.Operationissubjecttothefollowingtwoconditions: (2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause undesiredoperation. 75.00 mm 2 0 . 0 0 m m Warning (1)Thisdevicemaynotcauseharmfulinterference,and ThisdevicecomplieswithPart15ofFCCrules.Operationissubjecttothefollowingtwoconditions: (2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause undesiredoperation.
FCCID:2AHCL-STORM300 Page1/7 Internalphoto FCCID:2AHCL-STORM300 Page2/7 FCCID:2AHCL-STORM300 Page3/7 FCCID:2AHCL-STORM300 Page4/7 FCCID:2AHCL-STORM300 Page5/7 FCCID:2AHCL-STORM300 Page6/7 FCCID:2AHCL-STORM300 Page7/7 ---END---
FY-GZ001 深圳市宏图浩然科技有限公司 地址:东莞市常平镇桥沥村正昕工业园1栋5楼 电话:0755-27987626 E-mail:[email protected] 承认书 SPECIFICATIONFORAPPROVAL 客戶: CUSTOMER: 敏德 客戶料號: CUSTP/N: HT料號: HTP/N: HTHR-A11002015 産品型號: DESC: 1.双槽(中心开孔)磁片50mm、0.08*105P线长外露 15mm(不用背胶) 日期: DATE: 2019/8/8 版本: Version: A.0 制作 PREPAREDBY 审核 CHECKEDBY 批准 APPROVEDBY 客戶承认 CUSTOMERAPPROVE 李进 2019/8/8 唐荣军 2019/8/8 李自能 2019/8/8 FY-GZ001 版本变更履历 VersionChangeHistory 版本 Rev. 变更前 BeforeChange 变更后 AfterChange 更改日期 ChangeDate 批准 ApprovedBy A.0 新发行---- 制作 日期 李进2019/8/8 审核 日期 唐荣军2019/8/8 批准 日期 李自能2019/8/8 FY-GZ001 深圳市宏图浩然科技有限公司 版本 产品规格书SPECIFICATION A/0 客户CUST 敏德 产品规格Φ20.5*43*0.08*105P-16-15LC 客户料号CUSTP/N 内部料号INP/N HTHR-A11002015 一、尺寸DIMENSION:(mm) 二、原理图SCHEMATICDIAGRAM: A 43±0.5 B 20.5±0.5 C 1.2±0.2 D 15±1.5 E 2.0-3.0 F 50±0.5 G 8.0ref H 2.5Max I 5.0-5.5 说明: 2.交叉出线,中间贴6mm高温 胶带 3.贴圆形中间开孔带G槽磁 片:磁片尺寸Φ5.0*50*1.0mm 4.(不用背胶) 三、绕线参数WindingSpecification: 序号 NO. 端子 TERMINAL 线径 WIRE 圈数 Turns 绕线方向 WindingDirection 1SF 丝包钱0.08*105P 10TSCW 四、电气特性ELECTRICALCHARACTERISTIC:: 温度TEMPERATURE:25±10°C,湿度RELATIVEHUMIDITY:65±20% 序号 NO. 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TESTFREQUENCY 测试仪器 TESTEQUIPMENTS 1IND.S-F3.8uH±20%单独线圈100KHz/1.0VLCZMETER1062B 2 IND.S-F6.3uH±10%加磁片100KHz/1.0VLCZMETER1062B 3DCRS-F 140mΩMax LCZMETER502B 制作 日期 李进2019/8/8 审核 日期 唐荣军2019/8/8 批准 日期 李自能2019/8/8 FY-GZ001 深圳市宏图浩然科技有限公司 版本 产品规格书SPECIFICATION A/0 客户CUST 敏德 产品规格 Φ20.5*43*0.08*105P-16-15LC 客户料号CUSTP/N 内部料号IN P/N HTHR-A11002015 五、包装方法Packaging 1.普通发泡棉包装盒5*8格,每格6PCS,一盒共240PCS 2.中性外箱:3盒*240PCS 制作 日期 李进2019/8/8 审核 日期 唐荣军2019/8/8 批准 日期 李自能2019/8/8
Page1of12 Address:No.11,WuSongRoad,Tel:86-769-22607797 DongchengDistrict,Dongguan,Fax:86-769-22607907 GuangdongProvince,China523117http://www.cpcteam.com TESTREPORT ReportNumber.........................: 90215-23-72-23-PP002 Dateofissue.............................: 2023-4-3 Testedby(+signature)...........:DukeChen Approvedby(+signature).....: JasonGao TestingLaboratoryname......: SLG-CPCTestlaboratoryCo.,Ltd. Address......................................: No.11,WuSongRoad,DongchengDistrict,Dongguan,GuangdongProvince, China523117 Applicant’sname.....................: DONGGUANARUNINDUSTRIALCO.,LTD Address......................................: NO.13,XinfengStreet,Changlong,HuangjiangTown,DongguanCity, GuangdongProvince,P.R.China Manufacturer’sname............: DONGGUANARUNINDUSTRIALCO.,LTD Address......................................: NO.13,XinfengStreet,Changlong,HuangjiangTown,DongguanCity, GuangdongProvince,P.R.China Factory’sname.......................: DONGGUANARUNINDUSTRIALCO.,LTD Address......................................: NO.13,XinfengStreet,Changlong,HuangjiangTown,DongguanCity, GuangdongProvince,P.R.China Standard(s)................................: FCCPart1(1.1310)andPart2(2.1091) KDB680106D01RFExposureWirelessChargingAppv03r01 Testitemdescription..............: PowerStation TradeMark.................................: ARUN Model/Typereference.............: STORM300B01US,STORM300BXXYY(“YY”and“XX”arevariable) FCCID.........................................: 2AHCL-STORM300 Dateofreceiptoftestitem....: 2023-03-21 Date(s)ofperformanceof test...............................................: 2023-03-21-2023-03-27 SummaryofTestResults......:Pass TheSummaryofTestResultsbasedonatechnicalopinionbelongstothestandard(s). Generaldisclaimer: Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofSLG-CPCTestlaboratory Co.,Ltd.Thetestresultsinthereportonlyapplytothetestedsample. 90215-23-72-23-PP002Page2of12 Address:No.11,WuSongRoad,Tel:86-769-22607797 DongchengDistrict,Dongguan,Fax:86-769-22607907 GuangdongProvince,China523117http://www.cpcteam.com TABLEOFCONTENT 1.SUMMARYOFTESTRESULT......................................................................................................................3 2.GENERALINFORMATION............................................................................................................................4 2.1.DESCRIPTIONOFDEVICE(EUT).................................................................................................................4 2.2.DESCRIPTIONOFTESTMODES....................................................................................................................5 2.3.DESCRIPTIONOFSUPPORTDEVICE............................................................................................................5 2.4.DESCRIPTIONOFTESTFACILITY.................................................................................................................5 3.MEASURINGDEVICEANDTESTEQUIPMENT.........................................................................................6 3.1.FORMPEMEASUREMENT..........................................................................................................................6 4.RFEXPOSURE..............................................................................................................................................6 4.1.MEASURINGSTANDARD..............................................................................................................................7 4.2.REQUIMENTS..............................................................................................................................................7 4.3.TESTCONFIGURATION.................................................................................................................................8 4.4.BLOCKDIAGRAMOFTESTSETUP...............................................................................................................8 4.5.LIMITS........................................................................................................................................................9 4.6.MEASURINGRESULTS...............................................................................................................................10 90215-23-72-23-PP002Page3of12 Address:No.11,WuSongRoad,Tel:86-769-22607797 DongchengDistrict,Dongguan,Fax:86-769-22607907 GuangdongProvince,China523117http://www.cpcteam.com 1.SUMMARYOFTESTRESULT EMISSION DescriptionofTestItemStandard&LimitsResults MPE FCCPart1(1.1310)andPart2(2.1091) KDB680106D01RFExposureWireless ChargingAppv03r01 Pass Note:N/AisanabbreviationforNotApplicable. 90215-23-72-23-PP002Page4of12 Address:No.11,WuSongRoad,Tel:86-769-22607797 DongchengDistrict,Dongguan,Fax:86-769-22607907 GuangdongProvince,China523117http://www.cpcteam.com 2.GENERALINFORMATION 2.1.DescriptionofDevice(EUT) ProductName PowerStation TradeName ARUN ModelName STORM300B01US,STORM300BXXYY ModelDifferences STORM300B01US,STORM300BXXYY(”YY”=blankor standsforthealphabetfromAtoZ, ”XX”blankorstandsfortheArabicnumerals,whicharethe abbreviationofdifferentcolor,market,version,etc.) TheschematicdiagramandPCBofallmodelsareidentical, onlythemodelnameandappearancecoloraredifferent. TestModelSTORM300B01US Operationfrequency 110-205KHz ModulationType FSK AntennaType InductiveLoopantennawith10turns. WirelessCharging 10W Hardwareversionnumber V1.0 SoftwareversionnumberV1.0 ConnectingI/OPort(s)PleaserefertotheUser'sManual 90215-23-72-23-PP002Page5of12 Address:No.11,WuSongRoad,Tel:86-769-22607797 DongchengDistrict,Dongguan,Fax:86-769-22607907 GuangdongProvince,China523117http://www.cpcteam.com 2.2.Descriptionoftestmodes AllthetestmodeswerecarriedoutwiththeEUTinnormaloperation,thefinaltestmodeoftheEUTwasthe worsttestmodeforemissiontest,whichwasshowninthisreportanddefinedas: ModeTESTMODEDESCRIPPTION 1. Stand-bymode 2.Charging 3WirelessCharging Note: 1.Alltestmodeswerepre‐tested,butweonlyrecordedthew…
Text truncated - open the document above for the full version.
Page1of24 Address:No.11,WuSongRoad,Tel:86-769-22607797 DongchengDistrict,Dongguan,Fax:86-769-22607907 GuangdongProvince,China523117http://www.cpcteam.com TESTREPORT ReportNumber............................:90215-23-72-23-PP001 Dateofissue ................................ :2023-4-3 Testedby(+signature) .............. :DukeChen Approvedby(+signature) ........ :JasonGao TestingLaboratoryname ......... :SLG-CPCTestlaboratoryCo.,Ltd. Address.........................................: No.11,WuSongRoad,DongchengDistrict,Dongguan,GuangdongProvince, China523117 Applicant’sname........................:DONGGUANARUNINDUSTRIALCO.,LTD Address.........................................: NO.13,XinfengStreet,Changlong,HuangjiangTown,DongguanCity, GuangdongProvince,P.R.China Manufacturer’sname .............. :DONGGUANARUNINDUSTRIALCO.,LTD Address.........................................: NO.13,XinfengStreet,Changlong,HuangjiangTown,DongguanCity, GuangdongProvince,P.R.China Factory’sname.........................:DONGGUANARUNINDUSTRIALCO.,LTD Address ......................................... : NO.13,XinfengStreet,Changlong,HuangjiangTown,DongguanCity, GuangdongProvince,P.R.China Standard(s) .................................. :FCCRulesandRegulationsPart15SubpartC,Section209 Testitemdescription ................. :PowerStation TradeMark ................................... :ARUN Model/Typereference ................ :STORM300B01US,STORM300BXXYY(“YY”and“XX”arevariable) FCCID...........................................:2AHCL-STORM300 Dateofreceiptoftestitem......:2023-03-21 Date(s)ofperformanceoftest:2023-03-21-2023-03-27 SummaryofTestResults ......... :Pass TheSummaryofTestResultsbasedonatechnicalopinionbelongstothestandard(s). Generaldisclaimer: Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofSLG-CPCTestlaboratoryCo., Ltd.Thetestresultsinthereportonlyapplytothetestedsample. 90215-23-72-23-PP001Page2of24 Address:No.11,WuSongRoad,Tel:86-769-22607797 DongchengDistrict,Dongguan,Fax:86-769-22607907 GuangdongProvince,China523117http://www.cpcteam.com TABLEOFCONTENT TABLEOFCONTENT..................................................................................................................................................2 1.SUMMARYOFTESTRESULTS..............................................................................................................................3 2.GENERALINFORMATION......................................................................................................................................4 2.1.DescriptionofDevice(EUT)...............................................................................................................................4 2.2.IndependentOperationModes...........................................................................................................................4 2.3.DescriptionofTestFacility.................................................................................................................................5 2.4.DescriptionofSupportDevice............................................................................................................................6 2.5.MeasurementUncertainty..................................................................................................................................6 3.MEASURINGDEVICEANDTESTEQUIPMENT....................................................................................................7 3.1.MEASUREMENTEQUIPMENTUSED..............................................................................................................7 4.20DBBANDWIDTH..................................................................................................................................................8 4.1.TestProcedure...................................................................................................................................................8 4.2.TestResults........................................................................................................................................................8 5.POWERLINECONDUCTEDEMISSIONMEASUREMENT...................................................................................9 5.1.BlockDiagramofTestSetup..............................................................................................................................9 5.2.Limits..................................................................................................................................................................9 5.3.TestProcedure...................................................................................................................................................9 5.4.MeasuringResults............................................................................................................................................10 6.RADIATEDEMISSIONTEST.................................................................................................................................15 6.1.MeasurementProcedure..................................................................................................................................15 6.2.TestSET-UP(BlockDiagramofConfiguration)...............................................................................................15 6.3.RadiatedEmissionLimit...................................................................................................................................16 6.4.MeasurementResult........................................................................................................................................17 90215-23-72-23-PP001Page3of24 Address:No.11,WuSongRoad,Tel:86-769-22607797 DongchengDistrict,Dongguan,Fax:86-769-22607907 GuangdongProvince,China523117http://www.cpcteam.com 1.SUMMARYOFTESTRESULTS EMISSION DescriptionofTestItemStandard&LimitsResults ConductedEmission FCCPart15,SubpartC-Section15.207 ANSIC63.10-2013 Pass RadiatedEm…
Text truncated - open the document above for the full version.
FCCID:2AHCL-STORM300 Page1/2 Testphoto Conductedemission FCCID:2AHCL-STORM300 Page2/2 Radiatedemission ---END---
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |

Power Station
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Power Station
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
TWS earbuds
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz