FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Draperies.com/
  3. 2AHEZ-25-1140

2AHEZ-25-1140Tubular motor

Draperies.com
Tubular motor - FCC ID 2AHEZ-25-1140 - Draperies.com
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Jan 28, 2021
Application Purpose
Original Equipment
Date of Application
Jan 28, 2021
Equipment Note
Tubular motor
Frequency Range
433.92000000 - 433.92000000
Company
Draperies.com
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Caution 1. Do not expose motor to humid or extreme temperature conditions.2. Do not drill into motor.3. Do not cut the antenna and keep it clear from metal objects.4. Do not allow children to play with this device.5. If power cable or connector is damaged, do not use.6. Ensure correct crown and drive adaptor are used.7. Ensure power cable and aerial is clear and protected from moving parts.8. Cable routed through walls shall be properly isolated.9. Motor is to be mounted in horizontal position only.10. Before installation, remove unnecessary cords and disable equipment not needed for poweredoperation.11. Installation and programming to be performed by a qualified professional, use or modification outsidethe scope of this instruction may void warranty. Motor Installation Drive tube Drive tube Step 1 Cut drive tube to required length. Step 2 Ensure tube edge is clean and burr-free. Charging Instructions Micro-USB charging: 5V This motor has a built in Li-ion battery pack with integrated charge management.Max power input for recharging: 5V 2A. Before first use please charge motor for 6 hours. Using 5V charger (most phones charger is 5V ) . During operation, when the motor starts, the buzzer will beep 10 times, indicating a low-voltage alarm andneeds to be charged.During operation, the voltage was detected to be too low, the battery was about to run out, the batterystopped running and needed to be recharged. Micro-USB Port Rechargeable Battery Blinking red: Low battery alert Blinking green: Charging is processing Solid green: Battery has finished charging. Step 3 Mount correct crown & drive adapter onthe motor. Make sure drive adapter fits firmly andcrown rotates freely. Step 4 Align the notches on the crown and driveadapter with the drive tube, slide and fit the motor into drive tube. Mount idler and bracket on bothends. Drive Adapter Crown Circlip Bracket Bracket     BR-25-1140USB Instruction A-05 Attention Fields of ApplicationFeatures The motor is suitable for motorization of roller blinds. Never drop, knock, drill or submerge the motor. Keep the power cable in right position as following.Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty. Built-in ReceiverJog & TiltBuilt-in Lithium BatteryScan and ProgramStatus Feedback Switch DirectionStall ProtectionProgram ButtonReset to Factory ModeMemorized Setting Electronic LimitPreferred Stop PositionSpeed RegulationScene Control Specifications Following data for reference Working temperature: -10 ᯦ ~ +50 ᯦ Input Voltage: USB 5V 1A / USB 5V 2A Radio Frequency: 433.92MHzMaximum Running Time: 6 minutes * For reference only. Model Rated Torque (N.m) Rated Speed (rpm) Rated Power (W) DM25LEU/S-0.7/34 0.7 34 8 DM25LEU/S-1.1/28 1.1 28 10 DM25LEU/S-1.1/40 1.1 40 10 SAFETY NOTE 1. This appliance can be used by children aged from 8 years and above and persons with reduced physical,sensory or mental capabilities or lack of experienceand knowledge if they have been given supervision orinstruction concerning use of the appliance in a safeway and understand the hazards involved. 2. Children shall not play with the appliance.3. Cleaning and user maintenance shall not be made by children without supervision. 4. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifiedpersons in order to avoid a hazard. 5. WARNING: the drive shall be disconnected from its power source during cleaning, maintenance and whenreplacing parts. 6. The instructions shall state that the A-weighted emis sion sound pressure level of the drive is equal to orOHVVWKDQG% $ HJE\ZULWLQJ/S$”G% $  7. The mass and the dimension of the driven part shall be compatible with the rated torque and rated operatingtime. 8. The type of driven part the drive is intended for.9. WARNING: Important safety instructions. It is important for the safety of persons to follow these instructions.Save these instructions. 10. Do not allow children to play with fixed controls. Keep remote controls away from children.11. Frequently examine the installation for imbalance and signs of wear or damage to cables and springs. Do not use if repair or adjustment is necessary.12. Watch the moving shutter and keep people away until the shutter is completely closed.13. WARNING: Important safety instructions. Follow all instructions, since incorrect installation can lead to severe injury.14. Before installing the drive, remove any unnecessary cords and disable any equipment not needed for powered operation. Do not dispose of in general waste. Please recycle batteries and damage d electrical products appropriately. -2- -1- * After entering the limits fine tuning mode, the original preferred position will not be deleted; If there is no button operation within 2 minutes, it will arrive within 2 minutes, and the motor will turn to prompt, and automatically exitthe route adjustment mode; When fine-tuning the limit, press and P1 for more than 2S to exit the mode. * Press STOP for 2S,the motor moves to preferred position automatically. 2 Remove preferred position Press P2 (1 jog and 1 beep ), press STOP (1 jog and 1 beep ), STOP again(1 jog and make a long noise ), the preferred position is deleted. 3 Upper and Lower Limits Setting 2 Set lower limit ĺ DOWN DOWN STOP + 1 Set upper limit ĺ + UP UP STOP * If exit the limits setting status before you finish the limit setting, then the motor will take the previous limits if has; After the limits have been set successfully, the motor will enter the user mode. Press UP for 2S, operate the motor to desired upperposition, press and hold UP and STOP buttonssimultaneously for 2S (2 jogs and 3 beeps), upper limitis set. Press DOWN for 2S, operate the motor to desiredlower position, press and hold DOWN and STOPbuttons simultaneously for 2S (2 jogs and 3 beeps),lower limit is set. 1 Add A Preferred Position User mod…

Text truncated - open the document above for the full version.

Cover Letter(s)

Draperies.com 5500 N. Peck Rd. Arcadia, California, 91006, United States --------------------------------------------------------------------------------------------------------------------- Date: 2021-01-21 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AHEZ-25-1140 Confidentiality Request To whom it may concern, Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of the information accompanying this application as outlined below: ☒ Block Diagram☐ Tune-Up Information ☒ Operational Description☐ Security Information ☒ Schematics ☐ Parts List ☐ Software Defined Radio (SDR) Information The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Draperies.com ------------------------------- Kyle Choi /Manager Fylde

Cover Letter(s)

Draperies.com 5500 N. Peck Rd. Arcadia, California, 91006, United States -------------------------------------------------------------------------------- (FCC ID:2AHEZ-25-1140) POWER OF ATTORNEY DATE: 2021-01-22 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group (Shenzhen) Co., Ltd. Jandy So on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group (Shenzhen) Co., Ltd. Jandy So on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Draperies.com are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Draperies.com ------------------------------- Kyle Choi /Manager

External Photos

Reference No.: WTN21X01005018W-1 Page 2 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS EUT View 1 EUT View 2 Reference No.: WTN21X01005018W-1 Page 3 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EUT View 3 EUT View 4 Reference No.: WTN21X01005018W-1 Page 4 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EUT View 5 EUT View 6

ID Label/Location Info

Reference No.: WTN21X01005018W-1 Page 1 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn ANNEX EXHIBIT 1 - PRODUCT LABELING Proposed FCC ID Label Format Specifications: The label shall be securely affixed to a permanently attached part of the device, in a location where it is visible or easily accessible to the user, and shall not be readily detachable. The label shall be sufficiently durable to remain fully legible and intact on the device in all normal conditions of use throughout the device’s expected lifetime. Proposed Label Location on EUT FCC ID Label Location

Internal Photos

Reference No.: WTN21X01005018W-1 Page 5 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EXHIBIT 3 - EUT INTERNAL PHOTOGRAPHS EUT Housing and Board View 1 Solder Board-Component View 1 Reference No.: WTN21X01005018W-1 Page 6 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Solder Board-Component View 2 Solder Board-Component View 3 Reference No.: WTN21X01005018W-1 Page 7 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Solder Board-Component View 4 Antenna View

Test Report

Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Page 1 of 23 TEST REPORT Reference No.................... : WTN21X01005018W-1 FCC ID .............................. : 2AHEZ-25-1140 Applicant .......................... : Draperies.com Address ............................ : 5500 N. Peck Rd.Arcadia, CA 91006 Product Name .................. : Tubular motor Test Model. ....................... : BR-25-1140USB Standards ......................... : FCC Part 15.231 Date of Receipt sample .... : Jan.18, 2021 Date of Test ...................... : Jan.18, 2021 to Jan.21, 2021 Date of Issue .................... : Jan.22, 2021 Test Result ....................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Tested by: Reviewed By: Approved & Authorized By: Mike Shi / Project Engineer Lion Cai / RF Manager Silin Chen / Manager Reference No.: WTN21X01005018W-1 Page 2 of 23 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn TABLE OF CONTENTS 1. GENERAL INFORMATION ...................................................................................................................................4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................4 1.2 TEST STANDARDS...................................................................................................................................................5 1.3 TEST METHODOLOGY .............................................................................................................................................5 1.4 TEST FACILITY .......................................................................................................................................................5 1.5 EUT SETUP AND TEST MODE .................................................................................................................................6 1.6 MEASUREMENT UNCERTAINTY ..............................................................................................................................6 1.7 TEST EQUIPMENT LIST AND DETAILS .....................................................................................................................7 2. SUMMARY OF TEST RESULTS ...........................................................................................................................8 3. ANTENNA REQUIREMENT ..................................................................................................................................9 3.1 STANDARD APPLICABLE .........................................................................................................................................9 3.2 TEST RESULT..........................................................................................................................................................9 4. RADIATED EMISSIONS .......................................................................................................................................10 4.1 STANDARD APPLICABLE .......................................................................................................................................10 4.2 TEST PROCEDURE .................................................................................................................................................11 4.3 CORRECTED AMPLITUDE & MARGIN CALCULATION ............................................................................................12 4.4 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................12 5. 20DB BANDWIDTH ...............................................................................................................................................15 5.1 STANDARD APPLICABLE .......................................................................................................................................15 5.1 TEST PROCEDURE .................................................................................................................................................15 5.2 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................15 6. TRANSMISSION TIME .........................................................................................................................................16 6.1 STANDARD APPLICABLE .......................................................................................................................................16 6.2 TEST PROCEDURE .................................................................................................................................................16 6.3 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................16 7. DUTY CYCLE .........................................................................................................................................................18 7.1 STANDARD APPLICABLE .......................................................................................................................................18 7.2 TEST PROCEDURE .................................................................................................................................................18 7.3 SUMMARY OF TEST RESULTS/PLOTS ....................…

Text truncated - open the document above for the full version.

Test Setup Photos

Reference No.: WTN21X01005018W-1 Page 8 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EXHIBIT 4 - TEST SETUP PHOTOGRAPHS Conducted Emission Test Setup Radiation Emission Test Setup (Below 30MHz) Reference No.: WTN21X01005018W-1 Page 9 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Radiation Emission Test Setup (30MHz to 1GHz) Radiation Emission Test Setup (Above 1GHz) ***** END OF REPORT *****

Contact Information

Applicant

Kyle Choi
[email protected]6264719980Fax: 6263019426

Test Firm

Waltek Testing Group (Shenzhen) Co., Ltd.Jandy So
[email protected]86 755 33663308Fax: 86-755-33663309

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Draperies.com

Remote - FCC ID 2AHEZ-TR-8901 - Draperies.com
2AHEZ-TR-8901

Remote

Jan 31, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Tubular motor - FCC ID 2AHEZ-28-0228 - Draperies.com
2AHEZ-28-0228

Tubular motor

Jan 28, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Remote - FCC ID 2AHEZ-TR-8915 - Draperies.com
2AHEZ-TR-8915

Remote

Jan 27, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver