FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Draperies.com/
  3. 2AHEZ-28-0228

2AHEZ-28-0228Tubular motor

Draperies.com
Tubular motor - FCC ID 2AHEZ-28-0228 - Draperies.com
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Jan 28, 2021
Application Purpose
Original Equipment
Date of Application
Jan 28, 2021
Equipment Note
Tubular motor
Frequency Range
433.92000000 - 433.92000000
Company
Draperies.com
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Note: dial lithium battery switch, 0 is off switch, 1 is turn on switch. Setting button(P1) Lithium battery switch 5 V USB charging interface P2 M P2 Lithium Cell 3V Up button Setting button Stop button Down button P2 Working Temperature 1. Before the first use, please charge, to ensure full power after the use of(The motor uses a 5V USB charger to charge). Motor stop running when the supply voltage is lower than 8.0V,and it will restart again when the voltage is greater than 8.5V When the power voltage is lower than 7.0 V, the motor stops and the buzzer chirps. When the voltage is greater than 7.5v, it can be started again. When the voltage is lower than 10V, when the motor is running continuously, the alarm will be made and the buzzer will be called 10 times. When the power voltage is lower than 10.5 V, low voltage prompt, red light interval 1s frequency flash, total 10 times. ⑤During the charging process, the green light flashes between 1S and 1S, and the green light is always on after the battery voltage is greater than 12.4V, and the charging is completed. 2. Don’t operate motors when low voltage alarm 3. Operating The valid interval of the emitter button is 10s,the emitter will quit the set after 10s. The motor will run or beep for hint,please do the next step after the hint. 4. Set the limit position After the upper/lower limit setting,and the upper/lower limit position can’t at the same position. After the limit setting,with power off and memory function. Into the match-code status 2 minutes later,it will quit out the setting limits status automatically. Restore factory settings to clear all settings. 5. When the motor running without any operation, the maximum running time is 6 minutes,it will stop automatically. 6. If the emitter lost,please setting up again with the new emitter. Parameter (More models and parameters are subject to the nameplate) One motor can store maximum 20 channels; after fully stored, if pair new channels, only the last one wil l be covered circularly. Features: Driving tube must be close-fitting with crown and drive adapter. Choose crown and drive adapter based on the driving tube. Drive tube Drive tube Crown Runner Circlip  Stroke support Tail insert bracket 0 5 0 Type Rated Torque(N.m) The Input Voltage(V) Rated Speed(RPM) DM28LEU/S 0 1 0 1 0 1 2.0N.m USB 5V 2A Rated Power(W)15W 28RPM Emission Frequency(MHz) 433.92MHz Jog & Tilt Preferred Stop Position Low Power Consumption Restore Factory Setting Built-in Receiver Electronic Limit Switch Direction Stall Protection Speed Regulation Note: After the success of the reversing,retain all motor original settings. Note:After the Reset to factor mode,will delete all previous system function setting and the emitter code. 2, Paring / Pair additional emitter / Remove one emitter Enter paring status Repeat paring operation Loosen P1 Run for hint x1 4, Switch direction 5, Restore factory setting Press 2s Successful change the direction Loosen P1 Run for hint x3 Press 10s Restore factory setting successfull Loosen P1 Run for hint x4 Press 14s 1, Short press function Short press P1 Motor run upward / stoprunning / run downward ...... “Di~” x1 “Di” x3 “Di” x4 Note: This operation should be carried out under the conditions of motor has the limit. Note: in the factory mode, enter paring status; In the user mode, enter pair additional emitter or remove one emitter. Press 1s P2 The motor running speed is improved Press 1s Run for hint x2 Press 1s The motor running speed is reduced P2Up/DownUp/Down Run for hint x1 “Di” x1 Run for hint x1 “Di” x1 Press 1s Run for hint x2 Press 1s Run for hint x1 “Di” x1 Note: When the motor enters the radio lock mode, all the setting memory will be saved, only the radio receiving function has been disabled. 3, Radio lock mode The motor enters Radio Lock mode Loosen P1 Run for hint x2 Press 6s “Di” x2 Note: If the motor no response, it has already been the Max. or Min speed; The continuous motor speed has 3 grades, 20r/min, 24r/min, 28r/min, and the factory default is the fastest speed. 1 ISSUESOLUTION The motor doesn't run NUMBER a, Activate the motor afterfully charged b, Paring again; c, Contact after sales service for more details POSSIBLE CAUSES a, The battery is not activated. b, The emitter hasn't been paired; c, If press P1 button for long time, the motor no reaction, probably the board is short circuit, or the motor is broken. P2StopStop 3rd limit position is ok Press 1sPress 1s Press 1s Press 1s Press 1s P2 2.1, Set the 3rd limit position The 3rd limit position setting : If you have already set the upper and lower limit, then you can set the 3rd limit between upper and lower limit. Run for hint x1 “Di” x1 Run for hint x1 “Di” x1 Run for hint x2 “Di” x3 Up+DownStop Note: when under jog mode, press up/down button once, the motor will be jog running, if press more than 2S, the motor will be continously running. Press 5sPress 1s Run for hint x1 + Run for hint x2 “Di” x3 Run for hint x1 T<10s Loosen P1 Paring is OK Press 2s Press 2s Press 1s Press 2s + Run for hint x1 The curtain run downward Successfully switch direction Upper limit is OK Press 2s 3.1, Setting the upper limit The curtain run upward Press 2s 3.2, Setting the lower limit The curtain run downward The curtain stops running The curtain stops running UpStopUp+Stop DownStopStop+Down Run for hint x2 “Di” x3 Press 2s + Lower limit is OK Run for hint x2 “Di” x3 Press 2s + Stop UpUp+Down Note: In the user mode, power on the code can also operate;If 10s,no stay setting up emitter preess or no legal stop button code,10s to the limit,will automatically exit the setting up mode. If you need to reverse the rotateon of the motor controlled by the emitter,pls switch channel address. Note: After the success of the reversing,retain all motor original settings. Switch to jog mode Switch to running mode Run for hint x1 “Di~” x1 Run for hint x2 “Di” x3 “Di~” x1 The upper limit Run to the desired upper position Run to the desired lower positi…

Text truncated - open the document above for the full version.

Cover Letter(s)

Draperies.com 5500 N. Peck Rd. Arcadia, California, 91006, United States --------------------------------------------------------------------------------------------------------------------- Date: 2021-01-21 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AHEZ-28-0228 Confidentiality Request To whom it may concern, Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of the information accompanying this application as outlined below: ☒ Block Diagram☐ Tune-Up Information ☒ Operational Description☐ Security Information ☒ Schematics ☐ Parts List ☐ Software Defined Radio (SDR) Information The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Draperies.com ------------------------------- Kyle Choi /Manager Blah

Cover Letter(s)

Draperies.com 5500 N. Peck Rd. Arcadia, California, 91006, United States -------------------------------------------------------------------------------- (FCC ID:2AHEZ-28-0228) POWER OF ATTORNEY DATE: 2021-01-22 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group (Shenzhen) Co., Ltd. Jandy So on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group (Shenzhen) Co., Ltd. Jandy So on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Draperies.com are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Draperies.com ------------------------------- Kyle Choi /Manager

External Photos

Reference No.: WTN21X01005023W-1 Page 2 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS EUT View 1 EUT View 2 Reference No.: WTN21X01005023W-1 Page 3 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EUT View 3 EUT View 4 Reference No.: WTN21X01005023W-1 Page 4 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EUT View 5 Reference No.: WTN21X01005023W-1 Page 5 of 10 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EUT View 6

ID Label/Location Info

Reference No.: WTN21X01005023W-1 Page 1 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn ANNEX EXHIBIT 1 - PRODUCT LABELING Proposed FCC ID Label Format Specifications: The label shall be securely affixed to a permanently attached part of the device, in a location where it is visible or easily accessible to the user, and shall not be readily detachable. The label shall be sufficiently durable to remain fully legible and intact on the device in all normal conditions of use throughout the device’s expected lifetime. Proposed Label Location on EUT FCC ID Label Location

Internal Photos

Reference No.: WTN21X01005023W-1 Page 5 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EXHIBIT 3 - EUT INTERNAL PHOTOGRAPHS EUT Housing and Board View 1 Solder Board-Component View 1 Reference No.: WTN21X01005023W-1 Page 6 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Solder Board-Component View 2 Solder Board-Component View 3 Reference No.: WTN21X01005023W-1 Page 7 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Solder Board-Component View 4 Antenna View

Test Report

Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Page 1 of 23 TEST REPORT Reference No.................... : WTN21X01005023W-1 FCC ID .............................. : 2AHEZ-28-0228 Applicant .......................... : Draperies.com Address ............................ : 5500 N. Peck Rd.Arcadia, CA 91006 Product Name .................. : Tubular motor Test Model. ....................... : BR-28-0228 Standards ......................... : FCC Part 15.231 Date of Receipt sample .... : Jan.18, 2021 Date of Test ...................... : Jan.18, 2021 to Jan.21, 2021 Date of Issue .................... : Jan.22, 2021 Test Result ....................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Tested by: Reviewed By: Approved & Authorized By: Mike Shi / Project Engineer Lion Cai / RF Manager Silin Chen / Manager Reference No.: WTN21X01005023W-1 Page 2 of 23 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn TABLE OF CONTENTS 1. GENERAL INFORMATION ...................................................................................................................................4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................4 1.2 TEST STANDARDS...................................................................................................................................................5 1.3 TEST METHODOLOGY .............................................................................................................................................5 1.4 TEST FACILITY .......................................................................................................................................................5 1.5 EUT SETUP AND TEST MODE .................................................................................................................................6 1.6 MEASUREMENT UNCERTAINTY ..............................................................................................................................6 1.7 TEST EQUIPMENT LIST AND DETAILS .....................................................................................................................7 2. SUMMARY OF TEST RESULTS ...........................................................................................................................8 3. ANTENNA REQUIREMENT ..................................................................................................................................9 3.1 STANDARD APPLICABLE .........................................................................................................................................9 3.2 TEST RESULT..........................................................................................................................................................9 4. RADIATED EMISSIONS .......................................................................................................................................10 4.1 STANDARD APPLICABLE .......................................................................................................................................10 4.2 TEST PROCEDURE .................................................................................................................................................11 4.3 CORRECTED AMPLITUDE & MARGIN CALCULATION ............................................................................................12 4.4 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................12 5. 20DB BANDWIDTH ...............................................................................................................................................15 5.1 STANDARD APPLICABLE .......................................................................................................................................15 5.1 TEST PROCEDURE .................................................................................................................................................15 5.2 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................15 6. TRANSMISSION TIME .........................................................................................................................................16 6.1 STANDARD APPLICABLE .......................................................................................................................................16 6.2 TEST PROCEDURE .................................................................................................................................................16 6.3 SUMMARY OF TEST RESULTS/PLOTS ....................................................................................................................16 7. DUTY CYCLE .........................................................................................................................................................18 7.1 STANDARD APPLICABLE .......................................................................................................................................18 7.2 TEST PROCEDURE .................................................................................................................................................18 7.3 SUMMARY OF TEST RESULTS/PLOTS .......................…

Text truncated - open the document above for the full version.

Test Setup Photos

Reference No.: WTN21X01005023W-1 Page 8 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn EXHIBIT 4 - TEST SETUP PHOTOGRAPHS Conducted Emission Test Setup Radiation Emission Test Setup (Below 30MHz) Reference No.: WTN21X01005023W-1 Page 9 of 9 Waltek Testing Group (Shenzhen) Co., Ltd. http://www.semtest.com.cn Radiation Emission Test Setup (30MHz to 1GHz) Radiation Emission Test Setup (Above 1GHz) ***** END OF REPORT *****

Contact Information

Applicant

Kyle Choi
[email protected]6264719980Fax: 6263019426

Test Firm

Waltek Testing Group (Shenzhen) Co., Ltd.Jandy So
[email protected]86 755 33663308Fax: 86-755-33663309

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Draperies.com

Remote - FCC ID 2AHEZ-TR-8901 - Draperies.com
2AHEZ-TR-8901

Remote

Jan 31, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Tubular motor - FCC ID 2AHEZ-25-1140 - Draperies.com
2AHEZ-25-1140

Tubular motor

Jan 28, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Remote - FCC ID 2AHEZ-TR-8915 - Draperies.com
2AHEZ-TR-8915

Remote

Jan 27, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver